• Title/Summary/Keyword: Oxygen Flow Rate

Search Result 689, Processing Time 0.026 seconds

Effect of Light-Induced ROS Generation Unit on Inactivation of Foodborne Pathogenic Bacteria in Water (광유도 ROS 발생장치의 세척용수 중 식중독 세균에 대한 불활성화 효과)

  • Choi, Jaehyuk;Kim, Dawoon;Jung, Kyu-Seok;Roh, Eunjung;Ryu, Kyoung-Yul;Ryu, Jae-Gee
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.583-590
    • /
    • 2019
  • As the consumption of fresh fruits and vegetables increases, food poisoning caused by foodborne pathogen contamination is not decreasing. To prevent the contamination of produce, a quick and easy, low-cost, environmentally-safe disinfection method that does not affect produce freshness or quality is needed. This study demonstrates a new-concept, circulating-water disinfection system that purifies water by using newly developed 'LED-PS (photosensitizer)-induced ROS generation unit'. Using various types of LED-PS induced ROS generation units, we investigated the conditions for reducing the density of various pathogenic bacteria by more than 3 log CFU / mL in 1 hour. The major operational factors affecting the density reduction of the LED-PS-induced ROS generation unit were analyzed. Depending on bacteria species, the density reduction rate was varied. The effect of the units on reducing the density of Bacillus cereus and Pectobacterium carotovorum subsp. carotovorum was high, but the effect on foodborne bacteria such as Escherichia coli was relatively low. In this circulating water disinfection system, the density reduction effect tended to increase as the flow rate increased and the initial bacterial density decreased. As the amount of PS absorbed beads increased, the density reduction effect increased exponentially in some bacteria. Model 3280, a double cylindrical unit connecting two single cylindrical units, could completely sterilize more than 3 log CFU/mL of B. cereus and P. carotovorum subsp. carotovorum in 30 minutes of LED irradiation.

Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff (Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong;Hong, Sung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone is widely used in industry, because of its simplicity in design, high capacity, low maintenance and operational cost. The separation action of a hydrocyclone treating particulate slurry is a consequence of the swirling flow that produces a centrifugal force on the fluid and suspended particles. In spite of hydrocyclone have many advantage, the application for treatment of urban stormwater case study were rare. We conducted a laboratory scale study on treatable potential of micro particles using hydrocyclone filter (HCF) that was a combined modified hydrocyclone with perlite filter cartridge. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particles sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin, road sediment, commercial area manhole sediment, and silica gel particles. Experimental studies have been carried out about the particle separation performance of HCF-open system and HCF-closed system. The principal structural differences of these HCFs are underflow zone structure and vortex finder. HCF was made of acryl resin with 120 mm of diameter hydrocyclone and 250 mm of diameter filter chamber and overall height of 800 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The operated maximum of surface loading rate was about 700 $m^3/m^2$/day for HCF-open system, and 1,200 $m^3/m^2$/day for HCF-closed system. It was found that particle removal efficiency for the HCF-closed system is better than the HCF-open system under same surface loading rate. Results showed that SS removal efficiency with the HCF-closed system improved by about 8~20% compared with HCF-open system. The average removal efficiency difference for HCF-closed system between measurement and CFD particle tracking simulation was about 4%.

Comparison of Single-Breath and Intra-Breath Method in Measuring Diffusing Capacity for Carbon Monoxide of the Lung (일산화탄소 폐확산능검사에서 단회호흡법과 호흡내검사법의 비교)

  • Lee, Jae-Ho;Chung, Hee-Soon;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.555-568
    • /
    • 1995
  • Background: It is most physiologic to measure the diffusing capacity of the lung by using oxygen, but it is so difficult to measure partial pressure of oxygen in the capillary blood of the lung that in clinical practice it is measured by using carbon monoxide, and single-breath diffusing capacity method is used most widely. However, since the process of withholding the breath for 10 seconds after inspiration to the total lung capacity is very hard to practice for patients who suffer from cough, dyspnea, etc, the intra-breath lung diffusing capacity method which requires a single exhalation of low-flow rate without such process was devised. In this study, we want to know whether or not there is any significant difference in the diffusing capacity of the lung measured by the single-breath and intra-breath methods, and if any, which factors have any influence. Methods: We chose randomly 73 persons without regarding specific disease, and after conducting 3 times the flow-volume curve test, we selected forced vital capacity(FVC), percent of predicted forced vital capacity, forced expiratory volume within 1 second($FEV_1$), percent of forced expiratory volume within 1 second, the ratio of forced expiratory volume within 1 second against forced vital capacity($FEV_1$/FVC) in test which the sum of FVC and $FEV_1$ is biggest. We measured the diffusing capacity of the lung 3 times in each of the single-breath and intra-breath methods at intervals of 5 minutes, and we evaluated which factors have any influence on the difference of the diffusing capacity of the lung between two methods[the mean values(ml/min/mmHg) of difference between two diffusing capacity measured by two methods] by means of the linear regression method, and obtained the following results: Results: 1) Intra-test reproducibility in the single-breath and intra-breath methods was excellent. 2) There was in general a good correlation between the diffusing capacity of the lung measured by a single-breath method and that measured by the intra-breath method, but there was a significant difference between values measured by both methods($1.01{\pm}0.35ml/min/mmHg$, p<0.01) 3) The difference between the diffusing capacity of the lung measured by both methods was not correlated to FVC, but was correlated to $FEV_1$, percent of $FEV_1$, $FEV_1$/FVC and the gradient of methane concentration which is an indicator of distribution of ventilation, and it was found as a result of the multiple regression test, that the effect of $FEV_1$/FVC was most strong(r=-0.4725, p<0.01) 4) In a graphic view of the difference of diffusing capacity measured by single-breath and intra-breath method and $FEV_1$/FVC, it was found that the former was divided into two groups in section where $FEV_1$/FVC is 50~60%, and that there was no significant difference between two methods in the section where $FEV_1$/FVC is equal or more than 60% ($0.05{\pm}0.24ml/min/mmHg$, p>0.1), but there was significant difference in the section, less than 60%($-4.5{\pm}0.34ml/min/mmHg$, p<0.01). 5. The diffusing capacity of the lung measured by the single-breath and intra-breath method was the same in value($24.3{\pm}0.68ml/min/mmHg$) within the normal range(2%/L) of the methane gas gradient, and there was no difference depending on the measuring method, but if the methane concentration gradients exceed 2%/L, the diffusing capacity of the lung measured by single-breath method became $15.0{\pm}0.44ml/min/mmHg$, and that measured by intra-breath method, $11.9{\pm}0.51ml/min/mmHg$, and there was a significant difference between them(p<0.01). Conclusion: Therefore, in case where $FEV_1$/FVC was less than 60%, the diffusing capacity of the lung measured by intra-breath method represented significantly lower value than that by single-breath method, and it was presumed to be caused largely by a defect of ventilation-distribution, but the possibility could not be excluded that the diffusing capacity of the lung might be overestimated in the single-breath method, or the actual reduction of the diffusing capacity of the lung appeared more sensitively in the intra-breath method.

  • PDF

Effects of Various Proteins on the Autoxidation of L-Ascorbic Acid (비타민 C 산화반응에 대한 단백질의 공존효과)

  • Kim Mi-Ok;Jang Sang-Moon
    • The Korean Journal of Food And Nutrition
    • /
    • v.17 no.3
    • /
    • pp.294-301
    • /
    • 2004
  • Effects of superoxide dismutase(SOD), catalase(CAT), and such other proteins as bovine serum albumin(BSA), ovalbumin, lysozyme, and v-globulin on the autoxidation rates of L-ascorbic acid(AsA) in the absence of heavy metal ions and in the presence of Fe(III) or Cu(II) ions in water were examined. AsA was dissolved in a ultra-refined water at a concentration of 50 ${\mu}$M and 5 ${\mu}$M Fe(III) or 0.1 ${\mu}$M Cu(II) were added, and a oxygen gas was bubbled through the solution at a flow rate of 200 ml/min at 35$^{\circ}C$. The amount of remaining AsA in the reaction mixture was determined by using a UV spectrophotometer(at 265 nm). It was found that the Cu(II) at a concentration of 0.1 ${\mu}$M had a more accelerated for the autoxidation of AsA than Fe(III) at 5 ${\mu}$M. Moreover, it was confirmed that the ratio of remaining AsA was significantly larger in the presence of SOD, CAT, BSA, ovalbumin, lysozyme, and v-globulin than in the absence of proteins. The stabilization of AsA by various proteins were confirmed during the autoxidation of AsA in the presence of Fe(III) or Cu(II) in water. It was suggested that the non-enzymatic effects of SOD, CAT and some other proteins might be involves in the stabilization of AsA.

Biological treatment process for Food wastewater Using ER-1 bioreactor (다단 수직형 호기성반응기(ER-1)를 이용한 음식물 폐수의 생물학적 처리기술)

  • Lee, Jae-ki;Choi, Hong-Bok;Shin, Eung-Bai;Park, Ju-Hyoung;Choi, Eun-Ju;Kim, Jung-Rae;Park, Young-Sook
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.4
    • /
    • pp.113-120
    • /
    • 2006
  • Wastewater generated through the food waste recycling process have known high concentration, BOD 20,000~150,000 mg/L, which has to treat to the proper level because of a ban on reclamation. But it is impossible to treat less than 10 days by existing water treatment plant. Ecodays Ltd. is to treat this wastewater during 2~4 days by ER-1, which can simultaneously induce the modified PFR(Plug Flow Reactor) of the oxygen transfer rate, MLVSS concentration, and influent concentration to top from bottom of reactor. We tested the pilot test about low concentration food wastewater(BOD 16,500 mg/L) and high concentration food wastewater(64,431 mg/L) at the food waste recycling plant of H-Gun(20t/d). Hydraulic retention time(HRT) of ER-1 for low concentration food wastewater is 2.5day. In low concentration conditions, ER-1 treatment efficiency is to appear BOD 99%, COD 98%, TN 97%, and TP 96%. While ER-1 process for high concentration food wastewater treatment is composed 2 stages, which are to be HRT 2.5day for law wastewater and HRT 1.5 day for secondary treatment. In high concentration conditions, ER-1 treatment efficiency is to appear BOD 97%, COD 84%, TN 66%, and TP 95%. It is treated without temperature control about high temperature($50^{\circ}C$) to appear low treatment efficiency in high concentration conditions.

  • PDF

Blood Gas Management of a Membrane Oxygenator During Cardiac Surgery with Deep Hypothermic Circulatory Arrest (막형산화기에 의한 저체온 순환정지 심장수술시 혈액가스 조절)

  • Kim, W. G.;Lim, C.;Baek, Y. H.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.279-284
    • /
    • 1998
  • Deep hypothermic circulatory arrest(DHCA), in which systemic temperatures of 2$0^{\circ}C$ or less are used to allow temporary cessation of the circulation, is an useful adjunct in cardiac surgery. Because man in natural circumstances is never exposed to the extreme hypothermic condition, however, one of the controversial aspects is appropriate blood gas management($\alpha$STAT versus PH-STAT) during DHCA. This study aims to compare $\alpha$STAT with PH-STAT management for control of blood gases in experimental cardiopulmonary bypass(CPB) circuits with a membrane oxygenator. Fourteen young pigs were assigned to one of two strategies of gas manipulation. After a median sternotomy, CPB was established. Core cooling was initiated and continued until nasopharyngeal temperature fell below 2$0^{\circ}C$. The flow rate was set at 2,500 ml/min. Once their temperatures were below 2$0^{\circ}C$, the animals were subjected to circulatory arrest for 40mins. During cooling, blood gas was maintained according to either $\alpha$$\alpha$STAT or pH-STAT strategies. After DHCA, the body was rewarmed to normal body temperature. Arterial blood gases were measured before the onset of CPB, before cooling, before DHCA, at the point of 27$^{\circ}C$ during re-warming, on completion of re-warming. Cooling time was significantly shorter in $\alpha$-STAT than PH-STAT strategy, while there was no significant differences in rewarming time between two groups. Carbon dioxide was added between 5.5 and 3.0% in PH-STAT, while no carbon dioxide was added in $\alpha$STAT management. Amounts of oxygen administration were gradually lowered as temperature decreased. In this way, criteria of PH, PaCO, and PaO adjustments were satisfied in both $\alpha$STAT and PH-STAT management groups.

  • PDF

Estimation of Total Allowable Pollutant Loads Using Eco-hydrodynamic Modeling for Water Quality Management on the Southern Coast of Korea (생태계 모델에 의한 총허용 오염부하량 산정을 통한 연안해역의 수질관리)

  • Lee, Dae-In;Kim, Jong-Kyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.1
    • /
    • pp.29-43
    • /
    • 2007
  • For effective management of water quality on the southern coast of korea, a three-dimensional eco-hydrodynamic model is used to predict water quality in summer and to estimate the reduction rate in pollutant loads that would be required to restore water quality. Under the current environmental conditions, in particular, pollutant loadings to the study area were very high, chemical oxygen demand (COD) exceeded seawater quality criteria to comply with current legislation, and water quality was in a eutrophic condition. Therefore, we estimated reduction rates of current pollutant loads by modeling. The model reproduced reasonably the flow field and water quality of the study area. If the terrestrial COD, inorganic nitrogen and phosphorus loads were reduced by 90%, the water quality criteria of Region A were still not satisfied. However, when the nutrient loads from polluted sediment and land were each reduced by 70% simultaneously, COD and $Chl-{\alpha}$ were restored. When we reduced the input COD and nutrient loads from the Nakdong River by 80%, $Chl-{\alpha}$ and COD of Region B decreased below $10\;{\mu}g\;1^{-1}$ and $2\;mg\;1^{-1}$, respectively. The water quality criteria of Region C were satisfied when we reduced the terrestrial COD and nutrient loads by 70%. Total allowable loadings of COD and inorganic nutrients in each region were determined by multiplying the reduction rates by current pollutant loads. Estimated high reduction rates, although difficult to achieve at the present time under the prevailing environmental conditions, suggest that water pollution is very severe in this study area, and pollutant loads must be reduced within total allowable loads by continuous and long-term management. To achieve the reduction in pollutant loads, sustainable countermeasures are necessary, including the expansion of sewage and wastewater facilities, polluted sediment control and limited land use.

  • PDF

Effect of Nicotinic Acid on Sperm Characteristic and Oocyte Development after In Vitro Fertilization using Cryopreserved Boar Semen

  • Kim, Yu-Jin;Lee, Sang-Hee;Lee, Yeon-Ju;Oh, Hae-In;Cheong, Hee-Tae;Yang, Boo-Keun;Lee, Seunghyung;Park, Choon-Keun
    • Journal of Embryo Transfer
    • /
    • v.30 no.1
    • /
    • pp.7-15
    • /
    • 2015
  • The objective of this study was to investigate the efficiency of nicotinic acid on sperm cryosurvival and fertilization ability in frozen-thawed boar semen. Boar semen was collected by glove-hand method and was frozen using freezing solution treated to 0, 5, 10 and 20 mM of nicotinic acid. The frozen sperm for sperm characteristic analysis was thawed such as viability, acrosome reaction, and mitochondrial integrity. The frozen-thawed sperm was estimated by SYBR14/PI double staining for viability, FITC-PNA/PI double staining for acrosome reaction and Rhodamine123/PI double staining for mitochondrial integrity using a flow cytometry. The embryo was estimated in vitro development and DCFDA staining for reactive oxygen species assessment. As results, frozen-thawed sperm viability was significantly higher in 5 and 10 mM ($61.1{\pm}1.5%$,$64.7{\pm}2.0%$) of nicotinic acid than other groups (0 mM, $52.1{\pm}2.3%$; 20 mM, $47.8{\pm}5.1%$, P<0.05). The live sperm with acrosome reaction was significantly higher in 5 and 10 mM of nicotinic acid ($26.1{\pm}1.8%$, $24.9{\pm}1.5%$) than other groups (0 mM, $35.3{\pm}0.8%$; 20 mM, $36.5{\pm}1.9%$, P<0.05). The live sperm with mitochondrial integrity was significantly higher in 5 and 10 mM ($84.2{\pm}3.6%$, $88.4{\pm}2.3%$) of nicotinic acid than other groups (0 mM, $77.3{\pm}4.4%$; 20 mM, $73.3{\pm}3.6%$, P<0.05). Blastocyst rate of in vitro development was significantly higher in 10 mM ($17.0{\pm}1.3%$) of nicotinic acid than other groups (0 mM, $9.4{\pm}0.5%$; 5mM, $12.6{\pm}0.8%$; 20 mM, $5.0{\pm}1.0%$, P<0.05). Moreover, total cell number was higher in 5 and 10 mM ($53.6{\pm}2.9%$, $57.9{\pm}2.8%$) of nicotinic acid than other groups (0 mM, $41.0{\pm}1.4%$; 20 mM, $23.2{\pm}2.8%$, P<0.05). Hydrogen peroxide in embryos was lower in 5 mM nicotinic acid ($0.7{\pm}0.1%$) than other groups (0 mM, $1.0{\pm}0.1%$; 10mM, $0.9{\pm}0.0%$; 20 mM, $1.4{\pm}1.0%$, P<0.05). In conclusion, nicotinic acid-treated semen improves cryosurvival and quality of spermatozoa. Also, the fertilized oocytes with nicotinic acid improve quality of embryo and blastocyst formation.

Analyze of I-V Characteristics and Amorphous Sturcture by XRD Patterns (XRD 패턴에 의한 비정질구조와 I-V 특성분석)

  • Oh, Teresa
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.16-19
    • /
    • 2019
  • A thinner film has superior electrical properties and a better amorphous structure. Amorphous structures can be effective in improving conductivity through a depletion effect. Research is needed on the Schottky contact, where potential barriers are formed, as a way to identify these characteristics. $SiO_2/SnO_2$ thin films were prepared to examine the amorphous structure and Schottky contact, $SiO_2$ thin films were prepared using Ar = 20 sccm. $SnO_2$ thin films were deposited using mixed gas with a flow rate of argon and oxygen at 20 sccm, and $SnO_2$ thin films were added by magnetron sputtering and treated at $100^{\circ}C$ and $150^{\circ}C$. To identify the conditions under which the amorphous structure was constructed, the XRD patterns were investigated and C-V and I-V measurements were taken to make Al electrodes and perform electrical analysis. The depletion layer was formed by the recombination of electrons and holes through the heat treatment process. $SiO_2/SnO_2$ thin films confirmed that the pores were well formed when heat treated at $100^{\circ}C$ and an electric current was applied over the micro area. An amorphous $SiO_2/SnO_2$ thin film with heat treatment at $100^{\circ}C$ showed no reflection at $33^{\circ}\;2{\theta}$ in the XRD pattern, and a reflection at $44^{\circ}2\;{\theta}$. The macroscopic view (-30 V