• Title/Summary/Keyword: Oxygen Control

Search Result 1,959, Processing Time 0.038 seconds

Numerical study of oxygen transport characteristics in lead-bismuth eutectic for gas-phase oxygen control

  • Wang, Chenglong;Zhang, Yan;Zhang, Dalin;Lan, Zhike;Tian, Wenxi;Su, Guanghui;Qiu, Suizheng
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2221-2228
    • /
    • 2021
  • One-dimensional oxygen transport relation is indispensable to study the oxygen distribution in the LBE-cooled system with an oxygen control device. In this paper, a numerical research is carried out to study the oxygen transport characteristics in a gas-phase oxygen control device, including the static case and dynamic case. The model of static oxygen control is based on the two-phase VOF model and the results agree well with the theoretical expectation. The model of dynamic oxygen control is simplified and the gas-liquid interface is treated as a free surface boundary with a constant oxygen concentration. The influences of the inlet and interface oxygen concentration, mass flow rate, temperature, and the inlet pipe location on the mass transfer characteristics are discussed. Based on the results, an oxygen mass transport relation considering the temperature dependence and velocity dependence separately is obtained. The relation can be used in a one-dimensional system analysis code to predict the oxygen provided by the oxygen control device, which is an important part of the integral oxygen mass transfer models.

Automatic Control of Fraction of Inspired Oxygen in Neonatal Oxygen Therapy using Fuzzy Logic Control

  • Chanyagorn, Pornchai;Kiratiwudhikul, Phattaradanai
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.2
    • /
    • pp.107-116
    • /
    • 2016
  • Premature babies of less than 37 weeks gestation might require oxygen therapy as an integral part of treatment and respiratory support. Because of their under-developed lungs, these so-called "preemies" might contract respiratory distress syndrome (RDS). To treat RDS, neonatal oxygen therapy is administered, where controlled oxygen gas is measured as a fraction of inspired oxygen ($FiO_2$). However, exposure to high oxygen content during long treatment could cause oxygen intoxication, which might cause permanent blindness due to retinopathy of prematurity (ROP), whereas insufficient oxygen exposure could cause severe hypoxia. A doctor would use oxygen saturation ($SpO_2$) data and prescribe a dose of $FiO_2$ to maintain $SpO_2$ within a suitable range. One objective is to maintain $SpO_2$ within the acceptable range using $FiO_2$ that is as low as possible. Adjustment of $FiO_2$ would normally be done by nurses every 15 to 30 minutes, which might not be safe in many situations. An error in $FiO_2$ adjustment during a manual procedure could be as large as +/- 2.5%. This paper presents a system that can determine an $FiO_2$ value suitable to the current $SpO_2$ and that automatically adjusts $FiO_2$ with an error clearance of +/- 0.25%.

3 Types of Set Point Controllers for Biological Wastewater Treatment Process

  • Kim, D.;Lee, I.B.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.97.1-97
    • /
    • 2001
  • One of the main problems to constitute control method on biologically oriented wastewater purification processes, e.g. activated sludge process, sequential batch reactor, rotating bio-disk contactor, etc. is that it is hard to control the target component directly. For instance, while biochemical oxygen demand, suspended solids, and chemical oxygen demand are the key components to check the process performance, one may not control them directly since they are the results of microbial activities related to numerous physiochemical factors. Therefore controllers for bioprocess should be designed to make favorable condition for microorganisms´ living, e.g. dissolved oxygen level favorable, mixed liquor suspended solids concentration suitable ...

  • PDF

Visuospatial Cognitive Performance, Hyperoxia and Heart Rate due to Oxygen Administration (산소 공급으로 유발된 공간 인지 능력, 혈중 산소 농도, 심박동율의 변화)

  • Chung Soon Cheol;Shon Jin Hun;Lee Bongsoo;Lee Soo Yeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.1
    • /
    • pp.193-198
    • /
    • 2005
  • Changes in visuospatial cognitive performance, blood oxygen saturation and heart rate due to the highly concentrated oxygen administration were observed in this study. Six male ($25.8 \pm$1.0) and six female (($23.8 \pm$ 1.9) adults were asked to perform 20 visuospatial tasks with the same level of difficulties by supplying two different oxygen levels (21%, 30%). Experiment consisted of Rest1 (1 min.), Control (1 min.), Task (4 min.), and Rest2 (4 min.) and physiological signals such as blood oxygen saturation and heart rate were measured through each stage. The result showed the accuracy of task performance increased significantly at 30% oxygen concentration compared with 21%, which means oxygen supply has positive effects on visuospatial cognitive performance. When 30% oxygen was supplied, blood oxygen saturation during control and task phases was increased and heart rate was decreased compared with 21%. It means that 30% oxygen can stimulate brain activities by directly increasing the actual level of blood oxygen concentration during cognitive performance, and enough oxygen supply during cognitive performance make heart rate decrease.

Effects of Oxygen Scavenging Package on the Quality Changes of Processed Meatball Product

  • Shin, Yang-Jai;Shin, Joong-Min;Lee, Youn-Suk
    • Food Science and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.73-78
    • /
    • 2009
  • Processed meatball products were packaged in a passive package without oxygen scavenger as 1 control and 3 active packages of which have PP-based oxygen scavenger master batch materials (OSMB) of 40, 80, and 100%(w/w) in the middle layer and stored at 23 and $30^{\circ}C$ up to 9 months. Quality changes of packaged products were evaluated by measuring the oxygen concentration of the headspace in containers, thiobarbituric acid (TBA), color, and flavor. The oxygen concentration of the package having 100% OSMB was lower than those of 40 and 80%. The color changes and TBA values of the meat ball in the package containing 100% OSMB were the least among the treatments. Using principal component analysis (PCA), the control showed more flavor change than the packages containing oxygen scavenger. As a result, all active packages could extend the shelf life of the meatball products compared with that of the passive package.

Corrosion Characteristics of HT-9 in 500℃ and 650℃ Pb-Bi Liquid Metal

  • Song, T.Y.;Cho, C.H.
    • Corrosion Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.94-98
    • /
    • 2006
  • The next generation nuclear power reactor will use Pb-Bi as the cooling material. The steel structure materials such as HT-9 used in the reactor suffer from corrosion when they are exposed to high temperature Pb-Bi. Therefore corrosion should be prevented to use Pb-Bi as the coolant material without any safety problem. One method is to control the oxygen content in Pb-Bi. An appropriate amount of oxygen in Pb-Bi can produce a thin oxide layer on steel, and this layer protects the steel from corrosion attack. Since the required oxygen content in Pb-Bi is in the range of $10^{-5}$ to $10^{-7}$ wt%, this small oxygen content can be controlled by flowing a mixture of hydrogen gas and water vapor. The stagnant corrosion test of HT-9 samples was performed by controlling the oxygen content up to 2,000 hours. The corrosion behavior of HT-9 was analyzed at the temperatures of $500^{\circ}C$ and $650^{\circ}C$ with a reduced condition and a oxygen content of $10^{-6}$ wt%.

Development and Evaluation of a Teensy Microcontroller-based O2 Mass Flow Controller (Teensy 마이크로 컨트롤러 기반 산소 유량 제어기 개발 및 성능평가)

  • Yu, Min Sang;Jang, Yeonsook;Kim, Muhwan;Cho, Sungbo
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.193-200
    • /
    • 2021
  • Flowmeter and oxygen sensors are listed in COVID-19 essential medical devices. This article reports a Teensy microcontroller-based Oxygen mass flow controller (MFC), core part of the oxygen respirator or extracorporeal membrane oxygenation (ECMO). The developed MFC consisting of the microcontroller, MEMS flow sensor, and solenoid valve was able to accurately control 0 to 100 sccm of oxygen flow rate. The pressure of vacuum chamber increased proportionally to the flow rate (0.998 of Pearson correlation coefficient). The experimental results proved that the developed MFC exhibits comparable performance to a commercial MFC in accuracy, settling time, linearity with pressure, and repeatability of oxygen mass flow control. It is expected that this simple and cheap MFC is utilized for oxygen therapy against the severe acute respiratory syndrome coronavirus 2.

Assessment of Conscious Coginition Degree and Survey on Oxyen Generators using the Indoor Environment (실내환경중의 산소발생기 사용에 대한 인식도 평가)

  • 손종렬;조윤수;이규현;황상용
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.4
    • /
    • pp.64-69
    • /
    • 2003
  • Recently, Indoor air quality(IAQ) in workplace, residential environments and office has been concern of people, scientists and related the public. The oxygen in air was very important and essential element in every aspect of life. This study was performed on a questionnaire survey of 400 people about their awareness of indoor air quality, oxygen generators and measured of oxygen concentration in indoor environment. The results obtained were as follows; As respondents are having their 90% of daytime indoors a day, and 80% of them can feel indoor air pollutions degrees directly by particle matters. The control of most important problems of IAQ was the poor ventilation. We know that 22% of the respondents was recognized the oxgen generator. And for the installation of indoor pollution control equipment, 20% of all respondents installed oxygen generators because almost respondents was not satified the trust of ability purified indoor air pollutants. In the experimental results, it was found that the oxygen concentration of sampling sites were in the range of 20~23.5%. Therefore, it was recommended that the government related IAQ was suggested the guideline and control of oxygen generators. Finally, it appeared that the oxygen generators using indoor environment can be applied to new technology for cleaning of indoor air.

An air-fuel ratio control for fuel-injected automotive engines by neural network (신경회로망을 이용한 연료 분사식 자동차 엔진의 공연비 제어)

  • 최종호;원영준;고상근;노승탁
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.1006-1011
    • /
    • 1991
  • In this paper, a neural network estimator which estimates the output of the wide range oxygen sensor is proposed, The neural network estimator is constructed to give the output of the wide range oxygen sensor from rpm, fuel injection time, throttle position, and output voltage of the exhaust gas oxygen sensor. And, using this estimator, PI controller for air-fuel ratio control is designed. Experiment results show that the proposed method gives good results for SONATA engine under light load and constant rpms.

  • PDF

The Effect of Dissolved Oxygen on Microbial Transglutaminase production by Streptoverticillium morbaraense (용존산소 농도 조절이 미생물유래 Transglutaminase 생산에 미치는 영향)

  • 유재수;전계택;정용섭
    • KSBB Journal
    • /
    • v.18 no.2
    • /
    • pp.155-160
    • /
    • 2003
  • The effect of dissolved oxygen(DO) on microbial transglutaminase(mTG) production by Streptoverticillium morbaraense was studied in on-line computer controlled fermentation system. In order to control dissolved oxygen during fermentation, the agitation speed and aeration rate of 2.5 L fermenter ranged from 260 to 360 rpm and 0.3 to 3.9 L/min, respectively. The maximum microbial transglutaminase production was obtained at controlled 20% of dissolved oxygen among the various dissolved oxygen controlled batch cultures tested. The production of microbial transglutaminase at controlled 20% of dissolved oxygen was about 2.12 U/mL which was 1.1 times higher than that obtained in batch culture without control of dissolved oxygen. Also, the highest microbial transglutaminase production was obtained in fed-batch cultures in which dissolved oxygen was controlled at 20%, and it was improved almost 1.3 times in comparison with that without control of dissolved oxygen. Maximal dry cell weight and microbial transglutaminase production were 13.2 g/L and 2.6 U/mL, respectively. Finally, it was also found that fed-batch fermentation at controlled 20% of dissolved oxygen showed a good performance for the microbial transglutaminase production by on-line computer controlled fermentation system which may be generally applicable to other microbial cultures.