• 제목/요약/키워드: Oxidation Rate Constant

검색결과 171건 처리시간 0.034초

펜톤과 오존산화공정을 이용한 디젤오염토양의 복원 (Remediation of Diesel-Contaminated Soil by Fenton and Ozone Oxidation Process)

  • 최희철;이관용;최상일;이태진
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권2호
    • /
    • pp.34-39
    • /
    • 2010
  • In this study, the remediation of diesel contaminated soil was attempted with ozone treatment and Fenton reaction. About 10% of initial diesel concentration was removed by the ozone saturated solution. The pseudo-first order decomposition constant of diesel contaminated soil in the presence of 5% of hydrogen peroxide with 1.82, 2.82, 4.82, 6.82, and 11.82% of iron contents was 0.0228, 0.0308, 0.0482, 0.0471, and 0.0592 $min^{-1}$ respectively. The decomposition constant of the diesel was 0.0064 $min^{-1}$ with the addition of ozone saturated solution only. On the addition of ozone saturated solution in the presence of 5% hydrogen peroxide and 5% iron, the decomposition constant of the diesel was 0.0850 $min^{-1}$. These results indicated that the decomposition rate was 190% faster than without the addition of ozone saturated solution. Thus, the application of both ozone and the fenton reaction is promising for the remediation of the diesel contaminated soil.

석회석을 이용한 지하수 철분 산화 (Iron Oxidation using Limestone in Groundwater)

  • 심상준;강창덕;이지훤;조영상
    • 대한환경공학회지
    • /
    • 제22권1호
    • /
    • pp.73-81
    • /
    • 2000
  • 지하수 내의 철분 제거를 위해 일반적으로 포기법과 화학적 산화제를 이용한 산화법이 이용된다. 특히 오염수 포기에 이은 고-액 여과 분리 공정은 가장 널리 이용되는 물리 화학적 처리법이다. 이 방법은 주로 pH 6.5 이상의 경우 산화 제1철의 불용화에 매우 효과적인 것으로 알려져 있다. 본 연구에서는 석회석을 일정한 포기 하에 오염수와 접촉시켜 pH를 6.5 이상으로 유지하였다. 회분식 실험에서 석회석 입도 크기, 초기 철분 농도, pH, 온도 및 이온 세기 등에 의한 산화 제1철의 산화속도 변화를 고찰하였다. 석회석의 입도가 감소할수록 pH의 증가가 두드러지며 철분 산화 또한 급격히 증가함을 알 수 있었다. 산화 제1철의 산화속도는 초기 철분 농도, 온도 및 이온세기에 비례하는 것으로 나타났다.

  • PDF

제조조건에 따른 TbFeCo 박막의 산화 (The oxidation of TaFeCo thin films according to the depositio conditions)

  • 문정탁;김명한;이동철
    • 한국재료학회지
    • /
    • 제4권7호
    • /
    • pp.767-774
    • /
    • 1994
  • The TbFeCo thin films were prepared by the magnetron sputtering system to investigate the effect of the base pressure, film thickness and pre sputtering on the oxidation of the films by analyzing the change of matneto optical properties and by AES depth profile. The films prepared by the facing targets sputtering system represented almost constant magneto optical properties independent of the base pressure resulting from the short flight distance of the sputtered particles. Also, the thin TbFeCo films represented better perpendicular anisotropy as the films thickness increased with pre sputtering. However, it was still needed a deposition rate higher than a certain critical deposition rate to obtain a perfect perpendicular anisotropy even at a very high film thickness.

  • PDF

알루미늄 표면의 정반사율 향상에 미치는 양극산화의 영향 (Influences of anodizing on improvement in reflection rate of aluminum surface)

  • 최광근;김동현;김훈;남인탁
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.207-211
    • /
    • 2002
  • Anodizing film was prepared by anodic oxidation of pure aluminum(purity > 99.50) using DC power supply for constant current mode in an electrolytic solution of surface of sulfuric acid. Effects of pre-treatment process such as chemical polishing, acid cleaning, alkali etching before anodic oxidation, were studied to microstructures and surface morphologies. A roughness on surface of anodizing film had to be decreased for amorphous phase by anodic oxidation. A roughness on surface of anodizing film decrease as annealing temperature increased in chemical polishing.

  • PDF

KINETICS OF ATRAZINE OXIDATION BY UV RADIATION AND OXALATE ASSISTED H2O2/UV PROCESSES

  • Choi, Hyun-Jin;Choi, Jong-Duck;Kim, Hyun-Kab;Lee, Tae-Jin
    • Environmental Engineering Research
    • /
    • 제11권1호
    • /
    • pp.28-32
    • /
    • 2006
  • The degradation of atrazine was explored using UV alone, $H_2O_2/UV$, oxalate/UV and oxalate-assisted $H_2O_2/UV$. The addition of oxalate to the $H_2O_2/UV$ (oxalate-assisted $H_2O_2/UV$) process was the most effective method for the degradation of atrazine. The overall kinetic rate constant was split into the direct oxidation due to photolysis and that by the radicals from hydrogen peroxide or oxalate. In semi-empirical terms, the initial concentration of hydrogen peroxide had a greater contribution than that of oxalate for atrazine oxidation.

Degradation of Phenol with Fenton-like Treatment by Using Heterogeneous Catalyst (Modified Iron Oxide) and Hydrogen Peroxide

  • Lee, Si-hoon;Oh, Joo-yub;Park, Yoon-chang
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권4호
    • /
    • pp.489-494
    • /
    • 2006
  • Goethite, hematite, magnetite and synthesized iron oxide are used as catalysts for Fenton-type oxidation of phenol. The synthesized iron oxides were characterized by X-ray diffraction (XRD), BET, X-ray photoelectron spectroscopy (XPS), and electron paramagnetic resonance (EPR). The catalytic activity of these materials is classified according to the observed rate of phenol oxidation. The effectiveness of the catalysts followed the sequence: ferrous ion > synthesized iron oxide >> magnetite hematite > goethite. According to these results, the most effective iron oxide catalyst had the structure similar to natural hematite. The surface oxidation state of the catalyst was between magnetite and hematite (+2.5 ~ +3.0). Phenol degraded completely in 40 min at neutral pH (pH = 7). Soluble ferric and ferrous ions were not detected in the filtrate from Fenton reaction solution by AAS. The formation of hydroxyl radicals was confirmed by EPR.

알루미늄 양극산화피막의 반사율 특성연구 (Study of reflection rate character of anodized aluminum thin film)

  • 김승겸;김동현;주인중;남인탁;김훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.227-232
    • /
    • 2003
  • Anodizing film was prepared by anodic oxidation of pure aluminum(purity > 99.50) using DC power supply for constant current mode in an electrolytic solution of surface of sulfuric acid. Effects of pre-treatment process such as chemical polishing, acid cleaning, alkali etching before anodic oxidation, were studied to microstructures and surface morphologies. A roughness on surface of anodizing film had to be decreased for amorphous phase by anodic oxidation. A roughness on surface of anodizing film decrease as annealing temperature increased in chemical polishing.

  • PDF

In-situ Monitoring of Anodic Oxidation of p-type Si(100) by Electrochemical Impedance Techniques in Nonaqueous and Aqueous Solutions

  • 김민수;김경구;김상열;김영태;원영희;최연익;모선일
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권9호
    • /
    • pp.1049-1055
    • /
    • 1999
  • Electrochemical oxidation of silicon (p-type Si(100)) at room temperature in ethylene glycol and in aqueous solutions has been performed by applying constant low current densities for the preparation of thin SiO2 layers. In-situ ac impedance spectroscopic methods have been employed to characterize the interfaces of electrolyte/oxide/semiconductor and to estimate the thickness of the oxide layer. The thicknesses of SiO2 layers calculated from the capacitive impedance were in the range of 25-100Å depending on the experimental conditions. The anodic polarization resistance parallel with the oxide layer capacitance increased continuously to a very large value in ethylene glycol solution. However, it decreased above 4 V in aqueous solutions, where oxygen evolved through the oxidation of water. Interstitially dissolved oxygen molecules in SiO2 layer at above the oxygen evolution potential were expected to facilitate the formation of SiO2 at the interfaces. Thin SiO2 films grew efficiently at a controlled rate during the application of low anodization currents in aqueous solutions.

과황산염과 나노영가철을 이용한 페놀의 전기화학적 산화 (Electrochemical Oxidation of Phenol using Persulfate and Nanosized Zero-valent Iron)

  • 김철용;안준영;김태유;황인성
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권2호
    • /
    • pp.17-25
    • /
    • 2017
  • The efficiency and mechanism of electrochemical phenol oxidation using persulfate (PS) and nanosized zero-valent iron (NZVI) were investigated. The pseudo-first-order rate constant for phenol removal by the electrochemical/PS/NZVI ($1mA^*cm^{-2}/12$ mM/6 mM) process was $0.81h^{-1}$, which was higher than those of the electrochemical/PS and PS/NZVI processes. The electrochemical/PS/NZVI system removed 1.5 mM phenol while consuming 6.6 mM PS, giving the highest stoichiometric efficiency (0.23) among the tested systems. The enhanced phenol removal rates and efficiencies observed for the electrochemical/PS/NZVI process were attributed to the interactions involving the three components, in which the electric current stimulated PS activation, NZVI depassivation, phenol oxidation, and PS regeneration by anodic or cathodic reactions. The electrochemical/PS/NZVI process effectively removed phenol oxidation products such as hydroquinone and 1,4-benzoquinone. Since the electric current enhances the reactivities of PS and NZVI, process performance can be optimized by effectively manipulating the current.

Characterization of Methane Oxidation by a Methanotroph Isolated from a Landfill Cover Soil, South Korea

  • Lee, Eun-Hee;Yi, Tae-Woo;Moon, Kyung-Eun;Park, Hyun-Jung;Ryu, Hee-Wook;Cho, Kyung-Suk
    • Journal of Microbiology and Biotechnology
    • /
    • 제21권7호
    • /
    • pp.753-756
    • /
    • 2011
  • A methane-oxidizing bacterium was isolated from the enriched culture of a landfill cover soil. The closest relative of the isolate, designated M6, is Methylocystis sp. Based on a kinetic analysis, the maximum specific methane oxidation rate and saturation constant were 4.93 mmol gdry cell $weight^{-1}{\cdot}h^{-1}$ and 23${\mu}M$, respectively. This was the first time a kinetic analysis was performed using pure methanotrophic culture. The methane oxidation by M6 was investigated in the presence of aromatic (m- and pxylene and ethylbenzene) or sulfur (hydrogen sulfide, dimethyl sulfide, methanthiol) compounds. The methane oxidation was inhibited by the presence of aromatic or sulfur compounds.