• Title/Summary/Keyword: Overvoltage

Search Result 359, Processing Time 0.031 seconds

A Study on the Harmonic Resonance during Restoration of Primary Restorative Transmission System (부하투입이 고조파 공진에 미치는 영향에 대한 고찰)

  • Lee, H.J.;Lee, K.S.;Park, S.M.;Yu, W.K
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.249-251
    • /
    • 2004
  • Harmonic resonant overvoltage during restoration of primary restorative transmission system originates in switching operations and nonlinear characteristics of equipments. Actually it is difficult to predict the occurrence of harmonic overvoltage, since they result from nonlinear characteristics of transformers and other equipments. This paper describes the analysis of domestic primary restorative transmission system using PSCAD/EMTDC. The harmonic resonance is verified and showed the relation with equipments which have nonlinear characteristics such as generator and transformer in this paper. And the solution to prevent harmonic resonance is proposed too. As a result, the PSCAD/EMTDC simulation showed slightly conflictive results that had been presented by IEEE Power System Restoration Working Group report.

  • PDF

Effect of current density, temperature and electrolyte concentration on Composition of Zn-Ni Electrodeposits (Zn-Ni도금의 합금화에 미치는 전류밀도, 온도와 전해액농도의 영향)

  • Kang, Soo Young
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.11
    • /
    • pp.307-312
    • /
    • 2017
  • In the industry, galvanizing using the principle of sacrificial anode is used Zn-Ni alloy plating was developed as one of the measures to increase the corrosion resistance rather than pure zinc plating. The alloy plating layer has a corrosion resistance of 4-5 times that of the pure zinc plating layer, so that it is applied to automotive parts requiring high corrosion resistance even though the plating cost is high. The amount of Zn-Ni alloy plating solution is a sulfuric acid bath, a chlorinated bath, an alkali bath, and an ammonia bath. Here, the influence of the electrolytic conditions on the composition of the alloy plating in the chloride bath was investigated. The results are explained by the cathode overvoltage and the diffusion coefficient. In general, as the overvoltage of the cathode increases, the concentration polarization becomes more important than the activation polarization. The concentration polarization is determined by element diffusion in the diffusion layer. That is, as the overvoltage of the cathode increases, the Zn content having a large diffusion coefficient increases.

Analysis on the Effect of Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter using EMTP (EMTP를 이용한 멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감필터의 효과분석)

  • Kwon, Young-Mok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.82-93
    • /
    • 2006
  • In this paper, filters are designed to reduce transients overvoltage in inverter fed high-voltage large-capacity induction motor drive system. Design issues for a LCR filter at the inverter output terminals to reduce the dv/dt of the inverter output pulse and a RC filter at the induction motor input terminals to match the characteristic impedance between cable and induction motor are examined in detail. These filters are modeled to be suitable to high-voltage large-capacity induction motor. The performance of the filter is evaluated through simulation using EMTP(ElectroMagnetic Transients Program). We presented filters that used high voltage large-capacity induction Motor on the basis of this. Effect of the filter is analyzed for variation of the cable length. Characteristics of filters are analyzed to reduce harmonic in voltage waveform of induction motor input terminal. The switching surge voltage became the major cause to occur the insulation failure by serious voltage stress in the stator winding of induction motor. Filter for to mitigate transients overvoltage presents a required component in drive system of high-voltage large-capacity induction motor. Also, proposed filters are proved through simulation using EMTP.

A Study on the Improvement of Technical Regulation for Overvoltage Performance of Telecommunication Protector in Customer Premises (구내 통신용 보호기의 과전압 제한 성능 기준 개선 연구)

  • Ko, Hong-nam;Choi, Mun-Hwan;Cho, Pyung-Dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.823-826
    • /
    • 2013
  • Subscriber Protector is installed in a point of connection between main wire and in-plant cable to protect telecommunication facilities and service users from overvoltage or overcurrent due to the lightning or induction. In Korea, there are regulations for obligation of installation and performance criteria of protectors, but these regulations in force can not cope with diversification of services because it stands on the basis of PSTN service only. In earlier paper, we suggested the improvement way of technical regulation for subscriber protector in customer premises. and in this paper, we propose revised criteria for overvoltage performance of protector in customer premises, and make feasibility of revised criteria through inspection tests.

  • PDF

Improvement of Initial Operating Characteristics of SCALDO Regulator by Pre-charger (사전충전모드를 통한 SCALDO 레귤레이터의 초기 동작특성 개선)

  • Kwon, O-Soon;Son, Joon-Bae;Song, Jong-Gyu
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.265-272
    • /
    • 2016
  • A SCALDO(Supercapacitor Assisted LDO) regulator is a newly studied regulator to improve the efficiency of a LDO regulator. Commonly a LDO regulator has very low efficiency and a SCALDO regulator can improve it considerably because this regulator can reuse meaninglessly wasted energy at the LDO regulator by a supercapacitor witch is attached between input and a LDO regulator. However this regulator has several challenges because it is a being studied regulator. One of them is an overvoltage issue. At initial operating of this regulator, a supercapacior is totally discharged and input is connected with a supercapacitor and a LDO regulator in series. Thus, input voltage is enabled to a LDO regulator and this input voltage is a significant value to a LDO regulator because commonly input voltage is bigger than twice output voltage. In this paper, to solve this overvoltage issue, we proposed a new SCALDO regulator that has a pre-charger for charging a supercapacitor before starting operation. And we found that a proposed SCALDO regulator can properly reduce overvoltage of a LDO regulator through experiments.

Analysis of Lightning Surge in the Underground Distribution Systems (지중배전계통에서 뇌서지특성 해석)

  • Lim, Kwang-Sik;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2219-2220
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF

Analysis of Lightning Surge in the Underground Distribution Systems (지중배전계통에서 뇌서지특성 해석)

  • Lim, Kwang-Sik;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.587-588
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF

Analysis of Lightning Surge in the Underground Distribution Systems (지중배전계통에서 뇌서지특성 해석)

  • Lim, Kwang-Sik;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1253-1254
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.

  • PDF

Analysis of Lightning Surge In the Underground Dlstrlbutlon Systems (지중배전계통에서 뇌서지특성 해석)

  • Lim, Kwang-Sik;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1713-1714
    • /
    • 2006
  • This paper aims to analyze the overvoltage in underground distribution systems when lightning surge strikes to overhead line. The model is established by EMTP/ATPDraw for actual distribution systems. Simulation is carried out considering variation of parameters such as length and lightning current.