• 제목/요약/키워드: Overheat

검색결과 73건 처리시간 0.028초

발전용 보일러 주증기 튜브 과열방지용 오리피스 설계기법 (The design method of overheat protection orifice for power plant boiler super heated tube)

  • 김범신;유성연;하정수;김의현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.373-378
    • /
    • 2003
  • It is important that overheat protection of super heated tube in boiler operation and maintenance. The overheat of super heat tube can make damage and rupture of tube material, which causes accidental shutdown of boiler. The super heated tube overheat is almost due to the lack of uniformity of gas temperature distribution. There are two ways to protect overheat of super heated tube. The one is to control hot gas operation pattern which is temperature or flow distribution. the other is to control super heated steam flow distribution. The former is difficult than the later, because of control device design. In this paper steam flow control method which uses orifices is proposed to protect overheat of super heat tube.

  • PDF

분전함에서 이상발열 감지를 위한 광온도센서의 동작특성 분석 (Operating Characteristic Analysis of Optic Temperature Sensor for Overheat Detection in Panel Board)

  • 문현욱;김동우;길형준;김동욱;이기연;김향곤
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.100-106
    • /
    • 2009
  • 본 논문에서는 전기설비의 전기적 접속부 또는 전기배선 등에서 발생하는 이상발열을 감지하는 방법에 대해 알아보고, 분전함에서의 발열상태를 실시간으로 모니터링하는 전력설비 진단시스템에 사용되고 있는 광온도센서에 대하여 동작특성을 실험, 분석하였다. 광온도센서의 동작특성 실험을 위한 열원으로는 Black Body와 Hot Plate를 사용하였으며 각각에서의 열원의 온도변화에 따른 광온도센서 출력전압값을 측정, 분석하였다. 그리고 분전함내 차단기 단자에서의 체결불량으로 인한 이상발열 감지 실험을 기존의 발열 감지방법인 열전대와 적외선 열화상장치를 이용하여 실시하였고, 광온도센서를 이용해 실시하여 결과를 비교 분석하였다. 실험결과, 광온도센서의 이상발열 감지능력이 유사함을 확인할 수 있었다. 이러한 분석 결과는 향후 RFID형 광온도센서를 이용한 전력설비 진단시스템의 현장 적용에 있어 기본 자료가 될 것으로 기대된다.

유속에 따른 열선의 과열비 조정을 통한 열선유속계의 감도향상에 관한 연구 (Sensitivity Enhancement of a Hot-Wire Anemometer by Changing Overheat Ratio with Velocity)

  • 이신표;고상근
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2678-2689
    • /
    • 1995
  • In this study, a new hot-wire anemometer which has greater sensitivity than that of a constant temperature anemometer (CTA) was proposed. In contrast to CTA, the wire working resistance of the new anemometer increases with flow velocity, that is, the operating mode of the wire becomes variable temperature. The variable temperature anemometer(VTA) was made by substituting a voltage controlled variable resistor such as photoconductive cell or transistor for one of the resistors in the bridge. By positively feeding back the bridge top signal to the input side of these electronic components, the wire overheat ratio could be increased with velocity automatically. Static response analyses of the VTA, constant voltage anemometer (CVA) and CTA were made in detail and calibration experiments were performed to validate the proposed operating principle. The wire operating resistance of the CVA decreases with velocity and this leads to lower sensitivity than that of a CTA. But the sensitivity of the newly proposed VTA is superior to that of a CTA, since the wire overheat ratio increases with velocity. Consequently, it is found that the major factor that is responsible for large sensitivity of a VTA is not the working resistance itself but the change of the wire working resistance with velocity.

모발건조기의 전기화재 위험요소에 따른 화재 감정기법 연구 (Study of Fire Appraisal Method According to Electrical Fire Hazards of Hair Dryer)

  • 문현욱;이기연;김동우;길형준;김향곤
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.113-118
    • /
    • 2011
  • In this study, investigation and appraisal method for the scene of a fire according to electrical fire hazards of hair dryer which is usually used at living space are presented. Hair dryer is briefly composed of heating part, wind part and control part. Electrical fire hazards of hair dryer are insulation destruction of power cord, ignition by overheat of heating coil, scattering spark on inside dust, overheat of motor by fan shackle, ignition by carelessness of user, and so on. Fire cause by hair dryer can be perceived through investigation about half-disconnection of power cord, contact badness of power plug, verification of heating coil, fan and switch. These results are expected to be utilized effectively in a countermeasure to prevent an electrical fire by hair dryer.

원형공간내 열분해 연료의 공간배치가 연소현상에 미치는 영향 (Influence of Pyrolyzing Fuel Disposition on Combustion Phenomena in a Cylindrical Enclosure)

  • 한조영;김정수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.680-685
    • /
    • 2000
  • Investigation on ignition and flame propagation of pyrolyzing fuel in a cylindrical enclosure is accomplished. The pyrolyzing fuel of cylindrical shape is located in an outer cylinder sustained at high-temperature. Due to gravity, the buoyancy motion is inevitably incurred in the enclosure and this affects the flame initiation and propagation behavior. The radiative heat transfer plays an important role since a high temperature difference is involved in the problem. Numerical studies have been performed over overheat ratio, and vertical fuel eccentricity. The location of flame onset is affected by the vertical eccentricity of inner pyrolyzing fuel as well as thermal conditions applied.

  • PDF

과열비에 따른 유체밀도 변화를 고려한 복사유체 유동 해석 (Plow Analysis for Radiating Fluid with Density Variation affected by Overheat Ratio)

  • 한조영;채종원;박응식;남문경
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.75-78
    • /
    • 2005
  • A numerical investigation has been performed to discuss the radiation-affected steady-laminar natural convection in an enclosure under a large temperature difference. Due to inherent nature of this study, the Boussinesq approximation is no longer valid. Therefore the radiating fluid in an enclosure is treated as a ideal gas. To examine the effects of thermal radiation on thermo-fluid dynamic behaviors in complex geometries, two incomplete partitions are introduced. Based on the results of this study, the dispositions of incomplete partitions with radiatively participating medium are found to incur a distinct difference in fluid-dynamic as well as thermal behavior.

  • PDF

전기화재 (ELECTRICAL FIRE)

  • 박헌식
    • 방재기술
    • /
    • 통권11호
    • /
    • pp.13-22
    • /
    • 1991
  • To understand electrical fire, the cause of it is classified into overcurrent, short circuit, leak, joint, overheat, accumulation of heat, spark, deterioration of insulation, static electricity, and lightning etc. and explained. And then by the precautions to it, proposed to the improvement of electric products, the completeness of safecty management and the use of alarm systems.

  • PDF

원형공간내 열분해 연료의 위치변화에 따른 점화 및 화염전파 영향 (Effect of Pyrolyzing Fuel Position on Ignition and Flame Propagation in a Cylindrical Enclosure)

  • 한조영;김정수
    • 대한기계학회논문집B
    • /
    • 제25권1호
    • /
    • pp.133-142
    • /
    • 2001
  • Investigation on ignition and flame propagation of pyrolyzing fuel in a cylindrical enclosure is accomplished. The pyrolyzing fuel of cylindrical shape is located in an outer cylinder sustained at high-temperature. Due to gravity, the buoyancy motion is inevitably incurred in the enclosure and this affects the flame initiation and propagation behavior. The radiative heat transfer plays an important role since a high temperature difference is involved in the problem. Therefore in all cases presented here, the intrinsic radiation effects are considered. Numerical studies have been performed over various governing parameters, such as Grashof number, overheat ratio, and vertical fuel eccentricity. Depending on the Grashof number, the flame behavior is found to be totally different: a separated visible flame appears as the Grashof number reaches 10(sup)7. The location of flame onset is also affected by the vertical eccentricity of inner pyrolyzing fuel as well as thermal conditions applied.

저압배선 선로의 단선사고 발생시 전기화재예방 제어장치(EFPCD)의 동작 특성에 관한 연구 (A Study on Dynamic Characteristics of EFPCD for Conductor Breaks in Low Voltage Wiring)

  • 이상호;신미영;이경호
    • 한국화재소방학회논문지
    • /
    • 제18권3호
    • /
    • pp.103-107
    • /
    • 2004
  • 현재 저압 배선 선로에 있어서 단선 사고로 인해 발생하는 스파크와 열은 전기화재의 주요 원인이 되고 있다. 또한 단선사고 시 발생하는 전류는 일종의 써지(Surge) 전류가 되어 통신, 가전제품, 컴퓨터 그리고 각종 측정기기의 소손 및 고장을 일으키며, 특히 단선사고는 다양한 안전점검 시 발견이 매우 어려운 실정이다. 따라서, 본 논문에서는 누전차단기(Earth Leakage Breaker)의 보조 제어장치, 즉 전기화재예방 제어장치(Electrical Fire Prevention Control Device)를 개발하여, 상기 단선사고 시 누전차단기의 동작신뢰성을 제고시켜, 스파크 및 열에 의한 전기화재를 예방하고자 한다.

전기적 열선의 발화 및 화재 위험성에 관한 연구 (A Study on Ignition and Fire Risks of Electric Heat Wire)

  • 민세홍;송병준
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.113-121
    • /
    • 2015
  • This study aims to examine the risk of electrical fire in places where electric heat wires are used. In general, the use of electric heating wires is becoming more common and prevalent in a bid to prevent increasing damage caused by freezing and bursting in residential water pipes, factory pipes and irrigation pipes in vinyl greenhouse and a variety of heat wire products are available in market with legal safety requirements imposed on them. However, the widespread use of anti-freezing burst heat wire products has caused increasing incidents of fire, which often fail to be incorporated into statistics due to quick onsite extinguishing and insignificant damage although damage is gradually on the rise. Against this backdrop, this study aims to look into the possibility of ignition caused by electric heat wires and the mechanism of how it turns into catching fire through overheat and short circuit tests for anti-freezing burst electrical heat wires (hereinafter called the 'heat wire') and expects to serve as the basis for further observations and analyses on the cause of fire and the process of ignition in a scientific manner.