• Title/Summary/Keyword: Overhead transmission lines

Search Result 179, Processing Time 0.027 seconds

An Efficient Method for Transmission of Contour Information in Mobile GIS Environments (모바일 GIS 환경에서 등고선 정보의 효율적인 전송 기법)

  • Choi, Jin-Oh
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1111-1116
    • /
    • 2009
  • For expression of contour lines in mobile GIS environments, the client needs to receive the numerical data with the topographical map from a server. At this point, a client can't get the entire raw data because of the mobile characteristics. The approach to get representative points and to make isogram by interpolation methods, has some problems. The approach requires huge computing overhead at the client and doesn't guarantee the correctness of the isogram. In this paper, a data structure, algorithm and implementation results for efficient transmission of contour information to a client which is constructed from elevation information at a server, are proposed.

An Application of Solenoid Eddy Current Sensor for Nondestructively Inspecting Deterioration of Overhead Transmission Lines due to Forest Fires (산불에 의한 가공송전선의 열화특성을 비파괴적으로 검출하기 위한 솔레노이드 와류센서의 응용)

  • Kim, Sung-Duck;Kim, Young-Dal;Jeong, Dong-Hwa
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.404-415
    • /
    • 2000
  • This paper describes several performances and nondestructive inspection for deterioration due to forest fires in overhead transmission lines. After discussing corrosion mechanism such as atmospheric and galvanic corrosion for aged ACSR conductors and its detection for them are presented. Through impedance analysis of a solenoid coil, it is shown that the eddy current sensor may be available to inspect severe fault or local corrosion. As the solenoid coil changes its impedance when the test conductor is inserted into the coil, it can be possible to measure deterioration degree caused by forest fires. Tensile strength, extension rate and sensor impedance are tested for some samples degraded by artificial fire. As increasing blazed period to some extent, the strength of aluminum strand begins to be reduced remarkably, while galvanized steel strand holds the similar strength to the initial value, despite of appearing a little loss of zinc layer. In general, it is shown that the sensor impedance would be increased while the tension load of conductor is reduced and the extension rate is contrarily increased. Therefore, the sensor output could exhibit the changes of mechanical performances, and would be used to detect such deterioration caused by forest fire in ACSR conductors built on the ridge of mountains. Finally, it was verified that the solenoid coil could be applicable to obtain any crucial inform for serious deterioration due to forest fires.

  • PDF

Live Lines Tracing Method in Power Distribution System with 3-phase-4 wires (삼상 다중 접지 배전계통에서 활선로 추적 방법)

  • Zheng, Yan-peng;Byun, Hee-Jung;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.559-562
    • /
    • 2017
  • In city, tracing of power transmission lines is difficult due to compound installation of overhead and underground lines, transposition, bad view caused by trees or big buildings. It is hard problem for electrical technician on site to trace power transformers or power lines to serve customers in 3 phase -4 wires power distribution systems. It is necessary that the correct and fast tracing method is required for load balancing among distribution lines. Old technology use to trace off-lines with high power impulse injection. Our proposed method use to trace live lines with very small power high frequency signal injection. Typical power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the power transformer to serve customers. Two end communication terminals are required to be synchronized between them for determination on electrically same phases. Challenging issue is to achieve synchronization without GPS providing synchronizing time. A novel power transformer and wire identification system is designed and implemented. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts in a big commercial building. Also some simulations are done to help and understand the concepts by using MATLAB Simulink simulator.

  • PDF

Aerodynamic Characteristics and Galloping Possibility of Ice Accreted Transmission Conductors by Wind Tunnel Tests (풍동실험을 통한 착빙 가공송전선의 공력 특성 측정 및 갤러핑 발생 분석)

  • Lee, Dooyoung;Goo, Jaeryang;Park, Sooman;Kim, Donghwan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.79-88
    • /
    • 2017
  • In this paper, the wind tunnel test for the measurement of aerodynamic characteristics of transmission conductors with asymmetric sections is described. A single conductor model and bundled conductor models with ice accreted shapes are tested both in steady and turbulent flow, and the aerodynamic coefficients are acquired. Transmission conductor galloping is a kind of wind-induced vibration which is characterized by primarily vertical oscillation with a very low frequency and a high amplitude. It is well known that transmission conductor galloping is generally caused by moderately strong, steady winds when a transmission conductor has an asymmetric cross-section shaped by accreted ice. Galloping should be considered from the design stage of overhead lines because it can cause severe wear and fatigue damage to attachments as well as transmission conductors. It is reported that there have been normally 20 events of galloping per year in Korea, which may be followed by serious consequences in the electric power system. Therefore, this research is performed to measure aerodynamic characteristics of ice accreted transmission conductors to understand and control transmission conductor galloping so that it would help to prevent unexpected failures and reduce the maintenance costs caused by galloping.

Analysis and Measurement of Lightning Parameters on Subscriber Telecommunication Lines (가입자 통신 선로에서의 뇌격 파라미터 분석과 측정)

  • Oh, Ho-Seok;Park, Dong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.11
    • /
    • pp.1309-1317
    • /
    • 2007
  • In this paper, the Induced voltage on transmission line by lightning was calculated using FDTD method and the lightning parameters such as peak voltage, rise time, and decay time for the lightning location and line length were analyzed. To verify the results, lightning induced voltage was measured in the field using real telecommunication line. Results from the collected data were compared with the calculated results. It was found that the rise time and the decay time were increased as the line length and the distance between the line and lightning location were increased. Also, the peak voltage was affected more by the overhead line length than by the total line length, while the rise time and the decay time were more affected by the total line length.

Development of a Diagnostic Module Based Maintenance Support Device for Fiber Optic Telecommunication Cable in Overhead Region (고소지역 작업현장에서 공중선 상태 진단 모듈 기반 정비 지원 장치 개발)

  • Kim, Hee-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.4
    • /
    • pp.469-474
    • /
    • 2014
  • Installed on telephone poles laid scrambling to monitor the status of the communication lines, and cost information can provid eadditional information tools to develop systems to support on-site monitoring. Aerial support for a maintenance monitoring module to apply an embedded system, and information processing applications manufactured. In this study, a comprehensive plan in accordance with the government's aerial maintenance work to prevent accidents spread support for the device to immediately take advantage of big cities and aerial maintenance business, Construction worker accused of bias and aims to improve efficiency of maintenance puts.

Spacer Damper Maintenance Method by Using the Spacer Jig in Overhead Transmission Lines (송전선로에서 스페이서지그(Spacer Jig)를 이용한 스페이서댐퍼 유지보수공법)

  • Kim, J.S.;Kwon, S.W.;Park, Y.B.;Kwon, S.W.;Mun, S.W.;Cho, S.M.;Kim, D.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.22-24
    • /
    • 2008
  • 다도체 송전선로에서 전선 간격 유지 및 진동을 완화시켜주는 역할을 하는 스페이서댐퍼가 손상 받게 되면 즉시 유지보수 및 교체 작업을 하여야 한다. 그러나 이러한 작업은 송전선로 위에서 이루어지므로 전선의 장력과 작업자의 하중으로 인해 유지보수 및 교체작업이 매우 어렵고, 작업시간이 많이 소요되며, 전선표면손상, 스페이서댐퍼의 위치 변동 및 무리한 작업으로 인한 작업안전성 저하 등의 문제점이 있다. 따라서, 상기한 문제점을 해소하고 작업 효율의 상승을 위하여 작업시 각 전선의 간격을 쉽게 벌리고 좁힐 수 있는 작업용 공구인 스페이서지그(Spacer Jig)와 이를 이용한 송전선로의 스페이서댐퍼 유지보수 및 교체공법을 개발하여 교체작업시간 단축 및 작업안전성을 향상시킨 우수한 기술을 개발하였다.

  • PDF

A Review of the Flashover Performance of High Voltage Insulators Constructed with Modern Insulating Materials

  • Khatoon, Shabana;Khan, Asfar Ali;Singh, Sakshi
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.5
    • /
    • pp.246-249
    • /
    • 2017
  • Pollution flashover of outdoor insulators is a common risk, which affects the safe operation of overhead transmission networks. Early electrical power systems, which feature insulators made from ceramic materials have been used all over the world with good performance. At present, non-ceramic insulators are in common use, as a result of their good electrical as well as mechanical properties. The aim of this paper is to discuss and compare the flashover performance of insulators typically used in power lines, such as, porcelain, ethylene-propylene-diene-monomer (EPDM) rubber, room temperature vulcanized (RTV) and high temperature vulcanized (HTV) coated silicone rubber. The effect of various parameters, including the severity of pollution, ice accumulation, and shade profile, are considered.. From the studies reviewed it was concluded that there is a distinct difference in the flashover voltages of different types of insulators, and the silicone provides the best flashover performance of all insulating materials.

Measurements of the Ground Resistance using the Test Current Transition Method in Powered Grounding Systems (측정전류전이법을 이용한 운전중인 접지시스템의 접지저항 측정)

  • Lee, Bok-Hui;Eom, Ju-Hong;Kim, Seong-Won
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.347-353
    • /
    • 2002
  • This paper presents an accurate method for measuring the ground resistance in powered grounding system. Most of substations and electric power equipments are interconnected to an extensive grounding network of overhead ground wires, neutral conductors of transmission lines, cable shields, and etc. The parasitic effects due to circulating ground currents and ground potential rise make a significant error in measuring the ground resistance. The test current transition method was proposed to reduce the effects of stray ground currents, ground potential rise and harmonic components in measurements of the ground resistance for powered grounding systems. The instrumental error of the test current transition method is decreased as the ratio of the test current signal to noise(S/N) increases. It was found from the test results that the proposed measuring method of the ground resistance is more accurate than the conventional fall-of-potential method or low-pass filter method, and the measuring error was less than 3[%]when S/N is 10.

Characterization and Field Measurements of NB-PLC for LV Network

  • Masood, Bilal;Ellahi, Manzoor;Khan, Waheed Aftab;Akram, Waqar;Usman, Muhamad;Gul, Muhammad Talha
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.521-531
    • /
    • 2018
  • This paper presents a procedure for field measurements which provides a generalized Narrowband Power Line Communications (NB-PLC) channel model for low voltage (LV) access network in order to deploy advanced metering infrastructure (AMI) within Lahore, Pakistan. The measurements of allocated sites were performed in the residential (urban and rural), industrial and commercial electricity consumers for the NB-PLC channel modeling of overhead transmission lines (TLs). On the basis of extensive field measurement results, the average attenuation profile and transfer functions are presented. The results obtained from field measurements are validated by comparing them with a proposed Simulink model. A close agreement in the measured and simulated transfer function (TF) results is observed. The proposed Simulink model is an effort to model the NB-PLC channels in an effective way, especially in South Asian countries.