• 제목/요약/키워드: Overcurrent

검색결과 184건 처리시간 0.025초

비상발전기 보호용 원판형 지락과전류계전기의 고조파영향에 관한 연구 (A Study on the Harmonics Effect of Disc-Type Over Current Ground Relay for Emergency Generator Protection)

  • 김경철;고훈
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.58-62
    • /
    • 2015
  • When an emergency generator is running, it supplies the power for critical loads. Generator protection requires the consideration of many abnormal conditions that may occur with generators include overvoltages and ground faults. Modern day power systems create harmonics within the electrical network that can have an impact upon the associated protective system. This paper focuses on the analysing of the cause and development of a solution for the malfunction of induction disc type overcurrent ground relay by generation of harmonics during emergency generator operation.

웨이브렛 변환을 이용한 철도 고압배전선로의 고장검출기법 (Fault Detection Technique in Railway High Voltage Distribution Lines using Wavelet Transform)

  • 정호성;한문섭;이장무;김주락;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.1274-1279
    • /
    • 2004
  • This paper proposes technique to detect ground fault in railway high voltage distribution lines. Overcurrent relay technique is widely used for detecting one line ground fault that occurs most frequently in railway high voltage distribution lines. However, ground fault in distribution line is usually high impedance fault with arc. Because the fault current magnitude measured in substation is very small, the conventional overcurrent relay can't detect the high impedance ground fault. Therefore this paper proposes the advanced technique using wavelet transform. It extracts D1 component from fault signals and detects fault comparing magnitude of D1 component in each phase. To evaluate this proposed technique, we model distribution system using PSCAD/EMTDC and extract various fault data. In conclusion this technique can detect ground fault including high impedance fault regardless of fault distance, fault impedance etc.

  • PDF

광전자식 과전류 보호계전기의 구현 및 성능 평가 (Implementation and Performance Evaluation of Opto-Electronic OverCurrent Relay)

  • 박병석;안성준;장문종;우희곤
    • 제어로봇시스템학회논문지
    • /
    • 제6권3호
    • /
    • pp.284-290
    • /
    • 2000
  • The measurement of electric current using optical techniques provides a number of important practical advantages including effective isolation from high line potentials and freedom from the saturation effects observed in conventional current transformers. In this work the optical current sensor which uses thin YIG(Yittrium Ion Garnet) film as a Faraday element has been developed. We have characterized this optical current sensor and implemented it to the OOCR(Opto-electronic OverCurrent Realy) Performance of the OOCR shows the possibility of replacing the present overcurrent relays with OOCR.

  • PDF

환상형 분산전원 단지 보호를 위한 전압제어 과전류 계전기 (Voltage-controlled Over-current Relay for Loop-connected Distributed Generators)

  • 김태희;강상희
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.1979-1985
    • /
    • 2016
  • A protection algorithm using a voltage-controlled overcurrent element for a looped collection circuit in a wind farm is suggested in this paper. Because the proposed algorithm uses voltage relaying signals as well as current relaying signals, any fault in the looped collection circuit can be cleared by voltage-controlled overcurrent relays located at the two adjacent relaying points, the nearest place in each direction from the fault point. The algorithm can also distinguish the external faults which occur at the outside of a wind farm from the internal faults. It means that the proposed algorithm can provide the proper ability of protection coordination to the relays in the looped collection circuits of a large wind farm. The performance of the proposed algorithm is verified under various fault conditions using PSCAD/EMTDC simulations.

유원시설 전기설비 설치에 대한 국내외 규정 비교 분석 (Comparison and Analysis of Domestic and Foreign Standard for electrical equipment installation of amusement park and ride)

  • 김기현;김종민;김한상
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.378-382
    • /
    • 2004
  • This paper gives information which is applied to install the electrical equipment of amusement park and ride. For analyzing the standard of electrical equipment installation, we research the related regulation of National Electrical Code(2002), IEC 60364-series and Technical standards for Electrical facilities of internal standard. Among electrical equipments of amusement park and ride, especially we study the transformer vaults, overcurrent protection and ground protection of electrical equipment. So we the furnished the installation information of transformer vaults, overcurrent and ground protection at amusement park and ride.

  • PDF

멀티 에이전트 시스템 (Multi-Agent System)을 이용한 배전계통의 적응 과전류보호 (Multi-Agent System having Adaptive Over Current Protection Function for Power Distribution Systems)

  • 장중구;이승재;임동진
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권8호
    • /
    • pp.365-372
    • /
    • 2001
  • This paper presents a new protection concept to achieve the adaptive optimal function by introducing the multi-agent system technology. Making each relay an agent which consists of relay agent module and coordinator module, each agent works autonomously to improve protection capability by cooperating with other agents. It is applied to the overcurrent protection system of the industrial power system in order to show the feasibility of the proposed methodology.

  • PDF

A Sensorless PMDC Motor Speed Controller with a Logical Overcurrent Protection

  • Guerreiro, M.G.;Foito, D.;Cordeiro, A.
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.381-389
    • /
    • 2013
  • A method to control the speed or the torque of a permanent-magnet direct current motor is presented. The rotor speed and the external torque estimation are simultaneously provided by appropriate observers. The sensorless control scheme is based on current measurement and switching states of power devices. The observers performances are dependent on the accurate machine parameters knowledge. Sliding mode control approach was adopted for drive control, providing the suitable switching states to the chopper power devices. Despite the predictable chattering, a convenient first order switching function was considered enough to define the sliding surface and to correspond with the desired control specifications and drive performance. The experimental implementation was supported on a single dsPIC and the controller includes a logic overcurrent protection.

설정치 변경에 의한 영상과전류계전기의 성능개선 (Developed Ability of Zero-phase Overcurrent Relay by Changed setting point value)

  • 김남호;윤달순;장성일;최정환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.220-222
    • /
    • 1998
  • This paper presents a method, which develops an ability of Zero-phase Overcurrent Relay. Zero-phase current is very useful factor of Fault decision in Protect Relaying system. Actually, the setting-point value of Designed Relay, using Zero-phase current, is fixed. So in the case of deciding fault, Fixed setting-point value is not suitable for changing Load. and cause errors in Distributions system. For solving this problem, This paper proposes the Changed setting point value Algorithm, which can be adaptive for changing Distributions system using Zero-phase current r.m.s. indexes. The results of simulation under Load changing and High impedance fault show that proposed algorithm is useful for changing Distributions system and decreasing errors.

  • PDF

단상 유도전동기의 구속운전조건에서 화재 위험성에 관한 연구 (Study on the Fire Risk in Locked-Rotor Condition of Single-Phase Induction Motor)

  • 지홍근;송재용
    • 한국화재소방학회논문지
    • /
    • 제34권2호
    • /
    • pp.64-71
    • /
    • 2020
  • 본 논문에서는 단상 유도전동기의 구속운전조건에서 화재 위험성에 관하여 기술하였다. 일반적으로 전동기의 고장 발생은 회전자의 회전 불량 등으로 인한 구속운전조건의 형태로 나타난다. 전동기의 기동 시에는 정격전류의 약 2~15배에 달하는 큰 돌입전류가 흐르게 되는데 단상 유도전동기에서 구속운전조건이 발생하게 되면 돌입전류에 준하는 전류가 지속적으로 고정자권선을 통해 흐르게 된다. 구속운전조건에서 고정자권선을 통해 흐르는 과전류에 의해 고정자 권선 내부의 온도가 상승하고, 최종적으로 절연물을 매개로 화재로 이어지는 특징이 나타난다. 본 논문에서는 임의로 구속운전조건을 만들고, 이때 고정자권선에 흐르는 과전류의 크기 및 온도 상승을 측정하였다. 실험결과로부터 구속운전조건에서는 정격전류에 비해 약 7배의 과전류가 발생하였으며, 고정자권선 내부의 온도가 약 300 ℃ 정도에서 화재로 진전되는 것을 확인하였다.

전기배선에서 과전류와 포화시간을 입력변수로 갖는 퍼지기반 전기화재가능성 분석 (Analysis for Electrical Fire Possibility Using Fuzzy Logic with Input Variables of Overcurrent and Saturation Time in the Indoor Wiring)

  • 김은진;김두현;김성철
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.34-39
    • /
    • 2015
  • The study is aimed to develop fuzzy logic system that has overcurrent and saturation time as input variable and possibility of electrical fire as output variable by making bad conductor area with physical damage to indoor wiring. Most previous studies focused on thermal characteristics depending on the current size and no study considered the current size and saturation time at the same time. Therefore, the paper made into account current value and saturation time together. To this end, it created bad conductor area half the size of IV conductor (1.6 mm) on purpose and transmit electrical current from 10A to 60A by unit of 2A to find out the thermal characteristics and saturation time for current. Based on the data that came out, the study applied fuzzy logic and established the current and saturation time as input variable and chance of fire as output variable. As a result, the center of area of the system that depended only on the existing current value was 75 while the system that applied both current and saturation time presented the chance of fire at 92. It is found that the chance of bad conductor area and deteriorated insulation of electrical wire had current and saturation time as important variables. The data can be used as basic data like deteriorated wire insulation or operation features of circuit breaker in investigating the cause of electrical fire.