• Title/Summary/Keyword: Overcast Sky

Search Result 29, Processing Time 0.023 seconds

Application of the Daylight Factor Formula with the Modified Split Flux (Modified Split Flux를 이용한 주광률 계산식 적용에 관한 연구)

  • Yun, Su-In;Yun, Gyeong;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.39-47
    • /
    • 2014
  • Daylighting has a great effect on people inside the room. It is also closely related to the lighting energy consumption. Daylight factor(DF) is a very important index for evaluation of the daylighting in overcast sky. The objective of this study is to verify the suitability of the Tregenza's Modified Split Flux formula for the calculation of the daylight factor. We compared the daylight factors calculated by two methods; one by a measurement with 1/5 scale model and the other by the Daysim program. We used variables for verification as window wall ratios(WWR) and angles of the sky visible. As a result, daylight factor calculated by Modified Split Flux is similar to the measurement when more daylight enters the inside. And error is significantly increased when the angle of the sky visible is $50^{\circ}$.

Design of Daylighting Aperture Using Daylight Factor Method and its Evaluation by Distribution of Sky Component (Daylight Factor Method를 이용한 채광창의 설계)

  • 지철근;권영혜
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.3 no.1
    • /
    • pp.58-63
    • /
    • 1989
  • 이등분한 실의 주광율(Daylight Factor)의 비를 규제도의 지수로서 Lumen Method와 같이 정하고, 이를 만족하는 실의 깊이를 검토한 후, 설계 평균 주광율을 만족하는 창의 면적을 구하였다. 본 논문에서 제안한 창의 면적 자체가 다른 벽면의 면적 변화에 영향을 주고 있음을 고려하지 않은 종래의 방법을 개선하였다. 이후 주광율 요소 중 가장 지배적인 양인 운천공으로부터 입사하는 성분(SCo: Sky Component from overcast Sky)의 분포를 창의 위치와 형태를 변화시켜 조사, 평가하였다.

  • PDF

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.

Visual Performance Evaluation Study of a Scaled Light-Shelf Model (축소모형을 이용한 광선반의 시환경 특성 평가 연구)

  • Cho, Yil-Sik;Kim, Byoung-Soo;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.63-71
    • /
    • 2003
  • According to the recent report, the lighting energy consumption of commercial buildings reaches to $30%\sim40%$ of the total energy consumption. It is more than that of cooling & heating energy consumption and it is the major target of energy-saving policy. It is obvious that they are interested in natural lighting device such as Light-shelf for the purpose of raising the lighting energy-saving efficiency. In most of highly developed countries, a thorough study on Light-shelf makes it possible to propose a practical plan while at home there leaves much to be desired to study a guiding principle of optimum plan in spite of its efficiency based on experiments using scale4 model and analysis of simulation. Aiming at making an optimum plan of Light-shelf suitable for the domestic situation, this study is worked by experiments using light-shelf and analysis of variables using illumination program. The experiments is to analyse the efficiency of Light-shelf on condition of the sky and the analysis is to make the simulation using illumination program. This study is composed of 1) the analysis of light with some variables such as presence of light-shelf and degree of angle using 1/2 scaled model 2) making the simulation using Lightscape, illumination program, In brief, concerning presence of light-shelf, it causes little difference in its efficiency in the overcast sky, whereas it decreases an illuminance of window side and provides inner side with the light, which decreases the ratio of the maximum to the minimum inner illuminance and makes the inner of illuminance to range evenly in the clear sky. On degree of angle, as the daylight increases in proportion of degree of angle, the ratio of the maximum to the minimum inner illuminance decreases, which makes it possible to increase the proportion of inner daylight.

Daylighting Performance of Lightpipe under Different Sky Conditions (천공상태에 따른 수직형 광파이프 시스템의 채광성능 평가)

  • Kong, Hyo Joo;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.3
    • /
    • pp.101-106
    • /
    • 2008
  • The use of daylighting has been increased recently due to energy and visual comfort. The aims of interior daylighting are to adequately illuminate visual tasks, to create an attractive visual environment, and to save electrical energy. Lightpipe can improve the distribution of light to interior spaces. This study aims to evaluate the comparative daylighting performance of lightpipe under different sky conditions with mock-up model, sized $6m{\times}6m{\times}4m$ ($w{\times}d{\times}h$). For the purpose, perpendicular lightpipe system was designed as 650 diameter, with an aspect ratio of 2. Totally 49 measuring points of and two of outdoor illuminance on the horizontal plane were monitored from 09:00 to 18:30 on April 29 and May 15 2008. Agilent data logger and photometric sensor were used. Light factor were used to analyse daylight performance under different sky condition. Under overcast sky condition and clear sky condition, the lightpipe system is suitable for KS recommendation level of illuminance.

Canopy Microclimate of Water-Seeding Rice during Internode Elongation Period (담수직파 벼의 신장기 군락내 미기후 특성)

  • Yun, Jin-Il;Shin, Jin-Chul;Yun, Yong-Dae;Park, Eun-Woo;Cho, Seong-In;Hwang, Heon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.42 no.4
    • /
    • pp.473-482
    • /
    • 1997
  • Temperature, humidity and wetness duration were monitored for fully developed paddy rice canopies with 3 different structures induced by the seeding method(puddled-soil drill seeding, DS ; hand broadcasting, HB ; machine broadcasting, MB). Within-canopy air temperature averaged over "clear sky" hours during the study period(maximum tillering through heading) was lower than the screen temperature at a nearby standard weather station, especially in the night. The same trend was true for "overcast sky" hours except the diurnal distinction. Vapor pressure within the canopy was high during the daytime and low in the night, making the daytime deviation from outside the canopy more significant on clear days. Under the overcast sky, the canopy maintained a steady 5 to 10% higher vapor pressure than the outside regardless of day or night. Daily maximum temperature was observed to be higher within the canopies with more leaf mass, making MB the highest, HB the lowest, and DS in between. Relative humidity was over 90% in the night and dropped to 70% in the mid-afternoon, but vapor pressure within the canopy was highest at around 13:00 LST. Dew point depression was lowest and, combined with the temperature, the relative humidity was highest in HB. Mean period of wetting duration was in the order of DS>HB>MB, while the dew point depression was greatest in DS.

  • PDF

The Influence of Photosensor Configurations on Control Performance of Daylight Dimming Systems in a Small Private Office (소규모 개인 사무실 공간에서 포토센서 적용조건에 따른 디밍 제어효과 분석)

  • Kim, Soo-Young;Lee, Ji-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.3
    • /
    • pp.231-242
    • /
    • 2011
  • This study examines influences of a daylight dimming control system on the variation of indoor illuminance and lighting energy savings in a small office space. Field measurements and a series of computation were performed for typical types of sky conditions in summer. Results indicate that the daylight illuminance under clear and partly-cloudy sky were close to the target illuminance during a majority of time due to a higher ratio of window to wall. However, the target illuminance was not kept successfully due to the variation of photosensor signals which were strongly influenced by desktop illuminance. The system with partially-shielded conditions succeeded to keep target illuminance under clear sky conditions. The system failed under overcast sky conditions since the electric light output from fixtures caused excessive signals to photosensors due to insufficient daylight on a desktop. Unshielded and fully-shielded conditions were not recommended for effective controls of the systems. The influence of lighting fixtures on photosensors should be minimized to achieve successful lighting controls by daylight dimming systems.

A Study on the Evaluation of Lighting Energy Consumption by Control Strategy of the Electric Lighting (전기조명 제어 전략에 따른 조명에너지 소비량 평가에 관한 연구)

  • Yun, Gyeong;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.119-125
    • /
    • 2012
  • The objective of this study is to evaluate the electric lighting energy consumption carried out by Daysim program. A comparison between the measurement and simulated exterior global horizontal illuminance shows differences about 10% and it is very similar to the measurement. The interior illuminance simulated by Daysim are 18.9% lower than the measurement and simulated lighting energy consumption is 10% lower than the measurement. Corrected annual lighting energy simulation results show that the best case is the combination of occupancy switch-off and dimming system with automatic controlled blinds (E-3). In case of no blinds, it occasionally derives the minimum lighting energy consumption but it causes the glare, so we need to be careful for choosing the control strategy. For the overcast sky, the lighting energy consumption is not changed significantly by control strategy while the lighting energy in the clear sky is changed noticeably. So we must know the right strategy for each case to control the electric lights and blinds.

The Evaluation of Daylighting Performances in Museum Exhibition Spaces Using Computer Program RADIANCE (RADIANCE 프로그램을 이용한 미술관 전시공간의 주광 환경 디자인 평가)

  • Kim, Chang-Sung;Chung, Seung-Jin
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.6
    • /
    • pp.77-84
    • /
    • 2009
  • Daylighting is one of the major elements in architectural design. It also plays an important role in the museums focused on displaying artistic works. Many architects have tried to predict daylighting performances in exhibition spaces during the design process of museums. The aims of this study are to present the design methods using the computer program RADIANCE that is available for the evaluations of daylighting performances in indoor space and to help architects design daylighting systems for better exhibition spaces of museums. For this study, Seoul Museum of Art was chosen and it was evaluated the recommended illuminance and the impacts of direct sunlight under the conditions of overcast sky and clear sky with sun. According to simulation results, they indicated that the alternative toplight system(sawtooth shape) was more effective for daylighting of exhibition spaces than the existing toplight system(pyramid shape) and this study showed a method to evaluate daylighting effects in exhibition spaces with various shapes of toplight systems.

Performance Assessment of Light Pipe System for the Advanced Luminous Environment of the Underground Parking Lot (지하주차장 빛환경 개선을 위한 광파이프 시스템의 채광성능 평가에 관한 연구)

  • Shin, Ju-Young;Hwang, Tae-Yon;Kim, Jeong-Tai
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.1
    • /
    • pp.25-33
    • /
    • 2010
  • Use of daylight in underground space interacts with physiological need for human beings and provides relief from feeling secluded. Light pipe system can deliver natural light into the space where it is needed and can be used as primary or a secondary light source with benefits of energy, productivity and health. To use light pipe system effectively under various conditions, it is important to investigate the effectiveness of light pipe system with reliable monitoring protocol. This paper presents the results of light pipe system performance used in underground parking lot under different sky conditions. Comparisons were made between the illuminance standards of underground parking lot and the monitored data. The results indicated that adequate illuminance level was shown until 4.5m distance from the light pipe under clear sky condition. However, additional lighting device showed be used under overcast sky to meet the proper illuminance level.