• Title/Summary/Keyword: Over-coring

Search Result 17, Processing Time 0.021 seconds

Fertilization Effects on Fine Root Biomass, Production, and Turnover Rate in a Pinus rigida Plantation

  • Hwang, Jaehong;Son, Yowhan
    • The Korean Journal of Ecology
    • /
    • v.26 no.2
    • /
    • pp.59-64
    • /
    • 2003
  • We examined the effects of fertilization [control (C), 200 kg N ha^{-1} + 25 kg P ha^{-1}$ (LNP), and 400 kg N $ha^{-1} + 50 kg P ha^{-1}$ (HNP)] on fine root (< 2 mm diameter) dynamics using monthly soil coring method in a 39-year-old Pinus rigida plantation of central Korea. The average fine root biomass (live + dead) (kg $ha^{-1}$ $\pm$ SE) during the first growing season for C, LNP, and HNP was 1301 $\pm$ 54, 1084 $\pm$ 47, and 1328 $\pm$ 22, respectively. The fine root production (kg $ha^{-1}$ $\pm$ SE) was 2394 $\pm$ 128 for C, 2048 $\pm$ 101 for LNP, and 2768 $\pm$ 150 for HNP, respectively. Over the same period, fertilization treatments had impact on N and P concentrations of live fine root. Nitrogen and P inputs (kg $ha^{-1}$ $yr^{-1}$) into the soil through fine root turnover for C, LNP, and HNP were 16.6 and 0.9, 17.2 and 0.9, and 24.1 and 1.6, respectively. There were no significant differences in fine root biomass and production during the first growing season after fertilization. However, fertilization increased fine root N and P concentrations, and in consequence resulted in increased N and P inputs into soil through fine root turnover.

Evaluation of Service Life in RC Column under Chloride Attack through Field Investigation: Deterministic and Probabilistic Approaches (염해 실태조사를 통한 철근 콘크리트 교각의 내구수명 평가 - 결정론적 및 확률론적 해석방법)

  • Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.67-74
    • /
    • 2015
  • RC (Reinforced Concrete) structures are considered as cost-benefit and durable however performances of structural safety and durability are degraded due to steel corrosion. Service life in RC structure is differently evaluated due to different local environmental conditions even if it is exposed to the same chloride attack. In the paper, 25 concrete cores from field investigation are obtained from 4 RC columns with duration of 3.5~4.5 years exposed to sea water. Through total chloride content measurement, surface chloride contents and apparent diffusion coefficients are evaluated. Service life of the target structure is estimated through deterministic method based on Fick's $2^{nd}$ Law and probabilistic method based on durability failure probability, respectively. Probability method is evaluated to be more conservative and relatively decreased service life is evaluated in tidal zone and splash zone over 40.0 m. Chloride penetration behavior with coring location from sea level and the present limitations of durability design method are investigated in the paper.

Global Environmental Changes and the Antarctic (지구환경변화와 남극)

  • Lee, Bang-Yong;Chung, Ho-Sung;Kang, Sung-Ho;Chang, Soon-Keun
    • Journal of the Korean earth science society
    • /
    • v.24 no.3
    • /
    • pp.216-233
    • /
    • 2003
  • This study delineates the phenomena related with global environmental changes such as global warming, ozone depletion, and El Ni${\tilde{n}}$o/Southern Oscillation (ENSO) noted in the Antarctic. Retreat of ice cliffs, glaciers, and calving of ice shelves indicate the effects of recently aggravated global warming. The ice cliff located at Marian Cove, King George Island, South Shetland Islands off the Antarctic Peninsula has been observed to be retreating faster in the last 7 years than in the previous 38 years since 1956. There are some indications of temperature and precipitation changes associated with ENSO around King Sejong Station. The regression analyses indicate significant trends such as a decrease in the total amount of ozone and an increase in ultraviolet radiation which was seen by a satellite (TOMS-EUV) in September and October which correspond to ozone-hole season over King Sejong Station. Increase of UV radiation due to the ozone depletion in the Antarctic has changed the growth rate of marine organisms. It may also result in changes to the productivity, biomass, and species composition of marine organisms which can affect the whole marine ecosystem. The recent ice-core drilling over Lake Vostok has been reviewed with emphasis on the four cycles of glacial stages over the past 420,000 years. It is time to show more interest in mainland Antarctica through investigations of the coring and vast ice sheet, terrestrial geology, and upper atmospheric sciences in order to understand the past environmental changes and to predict possible changes to the environment in the future.

Assessment of Microbial Decomposition in Soil Organic Matter Accumulation with Depth in Golf Greens (골프장 그린에서 토심별 토양 유기물 집적에 대한 미생물 분해성 평가)

  • Huh, Keun-Young;Kim, In-Hea;Deurer, Markus
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.4
    • /
    • pp.64-71
    • /
    • 2009
  • Excessive soil organic matter (SOM) is detrimental to turfgrass quality when used intensively in sand-based root zones, thereby affecting the sustainability of turfgrass systems. As part of a major project examining the sustainable management of SOM on golf greens, microbial decomposition on soil organic matter accumulation with depth was assessed and the effect of soil air-condition improvement and Ca fertilization was investigated by soil microbial respiration (SMR). Three soil samples from three depths(0~5, 5~10, and 10~15cm) of 5 year and 30 year old green were analyzed for SOM content. In 30 year old green, SMR and dehydrogenase activity(DHA) were analyzed to assess the soil microbial decomposition with depth. It was then divided into 4 plots: untreated as a control, dolomite-treated, 0~5cm deep section-removed, and 0~5 cm deep section-removed+dolomite-treated. After treatment, three soil samples were taken at 1, 2 and 4 weeks by the above-mentioned method, and analyzed for SMR to better understand SOM decomposition. SOM accumulation in the 0~5cm depth of golf greens can be controlled by intensive cultivation such as coring, but below 5cm is more difficult as the results showed that SOM content below 5cm increased over time. Soil microbial decomposition of organic matter will be necessary to reduce SOM accumulation, but SMR below 5cm was low and wasn't significantly altered by increasing exposure to air and fertilizing with Ca. As a result, aeration treatments such as coring and Ca fertilization might not be effective at improving soil microbial decomposition below 5cm depth in aged greens.

Derivation and verification of electrical resistivity theory for surrounding ground condition prediction of TBM (TBM 주변 지반상태예측을 위한 전기비저항 이론식 유도 및 검증)

  • Hong, Chang-Ho;Lee, Minhyeong;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.1
    • /
    • pp.135-144
    • /
    • 2020
  • Since the depth of tunneling with tunnel boring machine (TBM) becomes deeper and deeper, the expense for site investigation for coring and geophysical survey increases to obtain the sufficient accuracy. The tunnel ahead prediction methods have been introduced to overcome this limitation in the stage of site investigation. Probe drilling can obtain the core and borehole images from a borehole. However, the space in TBM for the probe drilling equipment is restricted and the core from probe drilling cannot reflect the whole tunnel face. Seismic methods such as tunnel seismic prediction (TSP) can forecast over 100 m ahead from the tunnel face though the signal is usually generated using the explosive which can affect the stability of segments and backfill grout. Electromagnetic methods such as tunnel electrical resistivity prospecting system (TEPS) offer the exact prediction for a conductive zone such as water-bearing zone. However, the number of electrodes installed for exploration is limited in small diameter TBM and finally the reduction of prediction ranges. In this study, the theoretical equations for the electrical resistivity survey whose electrodes are installed in the face and side of TBM to minimize the installed electrodes on face. The experimental tests were conducted to verify the derived equations.

Behavior Evaluation of Thin Bonded Continuously Reinforced Concrete Overlay on Aged Jointed Concrete Pavement(2) (노후 줄눈 콘크리트 포장 보수를 위한 얇은 연속 철근 콘크리트 덧씌우기 포장의 거동 평가(2))

  • Ryu, Sung-Woo;Cho, Yoon-Ho
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.101-110
    • /
    • 2010
  • In this paper, it has been studied about the CRCO to maintain or rehabilitate the aged JCP. The CRCO and JCO was constructed at useless section of Seo-Hae-Ahn express highway in South Korea. The performance evaluation was conducted. Especially, it was focused on the roll of longitudinal reinforced steels inserted into the CRCO. On crack survey results from field construction section, the reflection cracks at joint of the existing pavement occurred in CRCO. However, due to the constraints of longitudinal reinforced steels, crack width was small. Total crack length and quantity in the CRCO more than that in the JCO. And crack spacing in the CRCO was narrower than it in the CRCP. Through the bonding strength test results, if the cold milling and cleaning as well as surface treatment is applied, there will be no debonding problem at interlayer in the early age. From analysis of the horizontal behavior at the joint, the longitudinal reinforced steels constrained crack width which became wider than initial state over time. Also, that steel in the CRCO reduced the horizontal movement due to temperature variation(4 times than that in the JCO). But, if interface is debonded, the roll decreased. Vertical VWG data showed that CRCO did not occur debonding problem at steel location, but there was some problem in JCO. It was confirmed by field coring. The tensile strain appeared in the CRCO, But the compressive strain occurred in the JCO in early age. Through the FWD test result, deflection in the CRCO was less than that in the JCO. And K value in the CRCO was greater than it in the JCO.

Comparison of Thatch Accumulation in Warm-Season and Cool-Season Turfgrasses under USGA and Mono-layer Soil Systems (USGA 지반 및 약식지반에서 난지형과 한지형 잔디의 대취축적 비교)

  • Kim, Kyoung-Nam;Kim, Byoung-Jun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.1
    • /
    • pp.129-136
    • /
    • 2010
  • This study was initiated to investigate thatch accumulation in several turfgrasses grown under two soil systems. The 45 centimeter deep USGA system was constructed with rootzone, intermediate and drainage layers. The mono-layer system, however, was made with only a 30cm rootzone layer. Turfgrasses used in the study were comprised of 3 varieties from Korean lawngrass of Warm-Season Grass(WSG) and 3 blends and 3 mixtures from Cool-Season Grass(CSG). A total of 9 turfgrass treatments were replicated three times in RCBD in both systems. Cultural practices for the research plot followed a typical maintenance program for highly managed turf. Treatment differences for thatch accumulation were observed among the turfgrasses in both soil systems. Thatch under the USGA system was 9% greater than under the mono-layer system due to its more favorable conditions for turf growth. Higher thatch depth was found with Korean lawngrass, 34~87% in the USGA system and 16~75% in the mono-layer system when compared with CSG. Among WSG, the Joongji variety was the highest in thatch layer under both the USGA and mono-layer systems. Kentucky bluegrass(KB) was the greatest among CSG, since it is a rhizomatous-type in growth habit, resulting in faster production of organic matter over bunch-type of tall fescue and perennial ryegrass. Proper depth in the thatch layer was known to be beneficial by enhancing the resiliency and wear tolerance of the turf in athletic fields. Thus, KB was considered to be a very excellent turfgrass in terms of turf quality, environmental performance, physical properties and soccer player safety. However, disadvantages such as poor water-holding properties, more inclined to injury from environmental stresses and severe diseases and insect injury were also expected where thatch was excessively accumulated. Therefore, these results demonstrate that more frequent measures for controlling thatch such as vertical mowing, topdressing or coring should be employed for soccer fields with Korean lawngrass and KB over other turfgrasses.