• 제목/요약/키워드: Over discharge

검색결과 939건 처리시간 0.028초

Discharge Dynamics of AC Plasma Display Panel

  • Whang, Ki-Woong;Seo, Jeong-Hyun;Yoon, Cha-Keun;Chung, Woo-Joon;Kim, Joong-Kyun
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.53-57
    • /
    • 1999
  • To investigate the discharge dynamics of alternating current plasma display panel (ACPDP), we measured the spatio-temporally resolved VUV and IR emission by an intensified charge coupled device (CCD). The breakdown beings around the anode inner edge and moves towards the cathode surface. As the ionization intensifies in front of the cathode surface, another emission region appears on the anode surface. While the anode side emission does not move but grows, the cathode side emission moves out and spreads over the entire cathode surface. The discharge dynamics emission by a 2 dimensional numerical simulation suggests that a cathode-directed streamer formation play an important role.

  • PDF

Fabrication of Graphene Supercapacitors for Flexible Energy Storage

  • Habashi, M. Namdar;Asl, Shahab Khameneh
    • 한국재료학회지
    • /
    • 제27권5호
    • /
    • pp.248-254
    • /
    • 2017
  • In the present work, graphene powder was synthesized by laser scribing method. The resultant flexible light-scribed graphene is very appropriate for use in micro-supercapacitors. The effect of the laser scribing process in reducing graphene oxide (GO) was investigated. GO was synthesized using a chemical mixture of GO solution; then, it was coated onto a LightScribe DVD disk and laser scribed to reduce GO and create laser-scribed graphene (LSG). The CV curves of pristine rGO at various scan rates showed that the ultimate product possesses the ability to store energy at the supercapacitor level. Charge-discharge curves of pristine rGO at two different current densities indicated that the specific capacitance ($C_m$) increases due to the reduction of the discharge current density. Finally, the long-term charge-discharge stability of the LSG was plotted and indicates that the specific capacitance decreases very slightly from its primary capacitance of ${\sim}10F\;cm^{-3}$ and that the cyclic stability is favorable over 1000 cycles.

XLPE 특고압 전력케이블의 절연 진단 (Diagnostic Test of XLPE Ultra High Voltage Electric Power Cable)

  • 변두균;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.122-126
    • /
    • 2002
  • A diagnostic test of 15.4kV cross-linked polyethylene(XLPE) ultra high voltage power cables from generator in the Soyanggang hydro electric power plant was conducted over 3 months, beginning April 2001. According to the results, in the case of the power cables from generator 1, there was little possibility of proceeding rapid1y to failure or defect because the data from diagnosis doesn't indicate any failure, deterioration or partial discharge. However, in the case of the power cables from generator 2, the. polarization index show a slight abnormal condition of the insulator that is not severe, and the deterioration was also identified as not severe. However, the partial discharge had an abnormal condition which was severe.

  • PDF

Electro-optical Characteristics of the Degraded Functional Layer in an Alternating- Current Plasma Display Panel

  • Lee, Kyung Ae;Min, Booki;Son, Chang Gil;Byeon, Yong S.;Yoon, Sang Ho;Choi, Eun Ha
    • Applied Science and Convergence Technology
    • /
    • 제24권6호
    • /
    • pp.232-236
    • /
    • 2015
  • The electro-optical characteristics of several functional layers over the MgO protective layer were studied during the continuous discharge of an AC-PDP. In order to observe the degradation of each functional layer on the MgO protection layer, we measured the surface morphology, cathodoluminescence (CL) spectrum, the secondary electron emission coefficient (${\gamma}$) and the discharge characteristics after 500 hours of discharge during the operation of the AC-PDP.

AC-PDP의 제작결함과 전기적 특성의 상관관계에 관한 연구 (Discharge Characteristics of Surface Discharge AC PDP : Cross-talk and other geometric effect)

  • 김석기;이성현;박정태;박정후;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2019-2021
    • /
    • 1999
  • In this paper, the AC-PDP's structural defects with a gap between front and rear glass are investigated. Breakdown voltage, sustain voltage, current and brightness have been measured for various gaps between two plates under various gas pressures. The experimental results show that the firing voltage, sustain voltage and brightness were decreased whereas the discharge current was increased as the gap increased. When the gap is over $40{\mu}m$, it was impossible to drive cells separately.

  • PDF

AC PDP에서 고속 어드레싱을 위한 ADR(Address During Reset) 구동 방식 (The ADR(Address During Reset) Driving Method for High-Speed Addressing in an AC-PDP)

  • 송근영;김근수;이석현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권6호
    • /
    • pp.269-273
    • /
    • 2005
  • In order to achieve high efficiency and low cost, new high-speed addressing method is suggested. This can be implemented by reducing the address discharge time lag through the priming effect. This paper suggests a new ADR(Address During Reset) driving method which provides priming particles by a separated driving method without adding auxiliary electrode or auxiliary discharge. The experimental results show an approximately 100ns reduction in the formative delay time of address discharge and a reduction in jitter of over 200ns. Also, due to enough time being available for reset, there was a reduction of about 29$\%$ in linht emitted during the reset period considerably.

R134a 로타리 베인 압축기 급유 계통 해석 (Analysis of Oil Supply System of a R134a Rotary Vane Compressor)

  • 김호영;김현진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.113-118
    • /
    • 2008
  • For a R134a rotary vane compressor used for car air conditioners, characteristics of gas compression and oil supply have been studied. The compressor model under investigation has the low volume ratio of suction to discharge volumes so that there occur flow reversal from discharge port to compression chamber as the leading vane passes over the discharge port. As a result, the volumetric and adiabatic efficiencies turn out to be relatively low compared to other types of displacement compressors. Oil supply mechanism has been comprehended for mathematical modeling and oil flow rate has been calculated for the individual oil passages. This study on the gas compression and oil supply of a rotary vane compressor can be applied to a future design practice on a similar type of compressor.

  • PDF

FLUID-GRANULE MIXED FLOIW DOWNSTREAM OF SCOUR HOLE AT OUTLET OF HYDRAULIC STRUCTURE

  • Kim, Jin-Hong;Shim, Myung-Pil;Kim, Kyung-Sub
    • Water Engineering Research
    • /
    • 제3권3호
    • /
    • pp.155-162
    • /
    • 2002
  • This study presents the theoretical approach for volume concentration, velocity profile, and granular discharge on the fluid-granule mixed flow downstream of the scour hole at the outlet of the hydraulic structure. Concept of dilatant model was applied for the stress-strain relationships of fluid-granule mixed flow since the flow downstream of the scour hole corresponds to debris flow, where momentum transfers through particle collisions. Mathematical formulations were derived using momentum equation and stress-strain relation of the fluid-granule mixture. Velocity profile under the assumption of uniform concentration over flowing layer showed the downward convex type. Deposition angle of downstream hump was found to be a function of an upstream slope angle, a dynamic friction angle and a volume concentration irrespective of flow itself, Granular discharge and the overflow depth were obtained with given values of inflow rates. Experimental results showed relatively good agreements with theoretical ones.

  • PDF

다중 펄스 방식에 의한 고성능 오존발생 제어장치 개발 (Development of High Performance Ozone Generating Controller)

  • 이홍희;김형준
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권5호
    • /
    • pp.226-226
    • /
    • 2003
  • When an excessive voltage is applied to the discharge gap in ozone generator, the discharge room temperature becomes higher. As is well own, the efficiency of the ozone generation is deteriorated by the excessively hot temperature because of the decomposition reaction. In this paper, the simple small capacity ozone generating controller has been introduced, which provides effective and stable silent discharge characteristics over wide range input power. The proposed power controller has two important advantages, which imply that the production rate of ozone can be controlled linearly according to the delivered power and the surplus energy is recovered to the source. The experimental results are given to verify the performance of the pre proposed controller.

다중 펄스 방식에 의한 고성능 오존발생 제어장치 개발 (Development of High Performance Ozone Generating Controller)

  • 이홍희;김형준
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권5호
    • /
    • pp.226-230
    • /
    • 2003
  • When an excessive voltage is applied to the discharge gap in ozone generator, the discharge room temperature becomes higher. As is well own, the efficiency of the ozone generation is deteriorated by the excessively hot temperature because of the decomposition reaction. In this paper, the simple small capacity ozone generating controller has been introduced, which provides effective and stable silent discharge characteristics over wide range input power. The proposed power controller has two important advantages, which imply that the production rate of ozone can be controlled linearly according to the delivered power and the surplus energy is recovered to the source. The experimental results are given to verify the performance of the pre proposed controller.