• 제목/요약/키워드: Outside heat exchanger

검색결과 69건 처리시간 0.025초

액체흡수제 이용 태양열 공조시스템의 하계 능력에 관한 연구 (Research on the Performance of a Solar Air Conditioning System using a Liquid Desiccant in Summer)

  • 최광환;윤정인;김보철
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.33-38
    • /
    • 2002
  • In order to find out whether solar air conditioning system could be applied to building or not, the performance and evaluation on thermal environment of the system suggested was done during summer. A solar model house was constructed to find out the performance and thermal environment evaluation when it actually operated outside. As a result, regeneration rate increased rapidly when LiCl solution temperature was over $50^{\circ}C$ and the regeneration rate was $13\sim15kg$ during 9 hours operation. Furthermore the dehumidification rate was 12kg at maximum during 10 hours operating of a dehumidifier and indoor temperature and relative humidity was $28.4^{\circ}C$ and 39.1% in average respectively. On evaluation of thermal environment during summer, PMV value was slightly high, but thermal sensation vote was 71% within the comfort zone.

바닥복사 난방공간의 효율적인 난방제어방법 (The Effective Heating Control Method of the Radiant Floor Heating System)

  • 조성환;태춘섭
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.317-329
    • /
    • 1996
  • By describing the floor slab of a radiant heating system as a one dimensional transient heat exchanger problem, a dynamic analysis model to incorperate with TRNSYS program was developed and their results were compared with experimental results. Results showed that the both of TPOC(Two Parameter On-off Control) and TPSC(Two Parameter Switching Control) method using room air temperature and floor surface temperature as the control parameters does not maintain room air and floor surface temperature exactly at the setting temperatures. But TPSC method is a better candidate for the temperature regulations of room air and floor surface temperature than TPOC method which can keep on the upper and lower limit temperature according to outside temeperature and wall structure etc. And better thermal circumstance can be given by TPSC method than On-off and TPOC method and the overheating which can be occured at the radiant floor heating system with on-off heating control will be reduced.

  • PDF

DEVELOPMENT OF NIGHT COOLING SYSTEM FOR GREENHOUSE USING COOL AIR AND WATER FROM AN ABANDONED COAL MINE

  • Whoa S. Kang;Wie S. Kang;Lee, Gwi H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.1136-1145
    • /
    • 1996
  • This study was to develop the most effective cooling system which is needed to cool greenhouse during summer night to get early blooming of strawberries. Various cooling systems were designed and constructed to utilize the cool air and water from tan abandoned coal mine. Cooling systems built for this study were an evaporative cooling system with pad, cooling system using a small or large radiator , and duct cooling system using cool are drawn from coal mine. These systems were individual tested to investigate their effects on cooling greenhouse during summer night. Also, a combined cooling system was tested with operating an evaporative cooling system, small radiator, and duct cooling system simultaneously. The results in this study showed that individual cooling systems such as evaporative cooling system, small radiator, and cooling duct had about the same effect on cooling greenhouse. The combined system had little better cooling effect than that of individual cooling syst m except the large radiator . The most effective system for cooling of greenhouse was obtained with using a large a large radiator as the heat exchanger. With operating a large radiator, temperature inside the greenhouse was dropped to about 15-16$^{\circ}C$ while outside temperature was 23-24$^{\circ}C$ during summer night.

  • PDF

원주방향 균열 존재 증기발생기 전열관에 미치는 지지판의 굽힘제한 영향 (Restrained Bending Effect by the Support Plate on the Steam Generator Tube with Circumferential Cracks)

  • 김현수;진태은;김홍덕;정한섭;장윤석;김영진
    • 대한기계학회논문집A
    • /
    • 제31권2호
    • /
    • pp.277-284
    • /
    • 2007
  • The steam generator in a nuclear power plant is a large heat exchanger that uses heat from a reactor to generate steam to drive the turbine generator. Rupture of a steam generator tube can result in release of fission products to environment outside. Therefore, an accurate integrity assessment of the steam generator tubes with cracks is of great importance for maintaining the safety of a nuclear power plant. The steam generator tubes are supported at regular intervals by support plates and rotations of the tubes are restrained. Although it has been reported that the limit load for a circumferential crack is significantly affected by boundary condition of the tube, existing limit load solutions do not consider the restraining effect of support plate correctly. In addition, there are no limit load solutions for circumferential cracks in U-bend region with the effect of the support plate. This paper provides detailed limit load solutions for circumferential cracks in top of tube sheet and the U-bend regions of the steam generator tube with the actual boundary conditions to simulate the restraining effect of the support plate. Such solutions are developed based on three dimensional finite element analyses. The resulting limit load solutions are given in a polynomial form, and thus can be simply used in practical integrity assessment of the steam generator tubes.

폐광의 냉기 및 냉수를 이용한 온실의 야냉 시스템 개발 (Development of Night Cooling System for Greenhouse Using Cool Air and Water from an Abandoned Coal Mine)

  • 강화석;강위수;이귀현;오재헌;김일섭;류근창
    • 한국환경농학회지
    • /
    • 제15권2호
    • /
    • pp.223-231
    • /
    • 1996
  • 폐광으로부터 유출되는 냉기 또는 냉수를 이용하여 여름 동안 야간에 온실을 냉방시키는데 있어 가장 효율적인 냉각방법을 결정하기 위해 여러 종류의 냉각 장치가 제작 및 냉각 실험되어졌다. 온실을 냉방시키는데 있어 여러 냉각장치의 효율을 비교할 때 독립적으로 소형 radiator, 냉각 pad 및 냉기를 사용한 냉각방법은 거의 비슷한 결과를 나타냈다. 또한 대형 radiator를 제외한 여러 냉각장치를 동시에 가동하였을 때는 독립적으로 이러한 냉각장치를 각각 가동하였을 때 보다 약간 향상된 냉각 효율을 나타냈다. 그러나 대형 radiator를 독립적으로 사용했을 때 온실의 냉각 효율은 다른 냉각 방법에 비하여 상당히 좋았으며, 야간의 외기 온도가 $23-24^{\circ}C$ 범위에 있을 때 온실내의 공기 온도는 약 $15^{\circ}C$로 냉각되었다.

  • PDF

원격장 와전류 배관 탐상 시스템 개발 (Development of Remote Field Eddy Current Pipeline Inspection System)

  • 정진오;이재경;김형진
    • 비파괴검사학회지
    • /
    • 제21권5호
    • /
    • pp.556-560
    • /
    • 2001
  • 배관의 관벽투과 특성을 지닌 원격장 와전류 비파괴 검사법은 열교환기 세관 검사에서부터 천연가스 수송관에 이르기까지 다양한 형태의 배관과 결함을 대상으로 적용 연구가 진행되고 있다. 공칭 외경 100mm의 주철관은 주로 상수도 관로의 배수관으로 활용되고 있는데, 차량 진동과 부식에 의한 결함의 생성으로 정수의 누수 문제를 일으킨다. 그러나, 탐상 경제성 및 효용성 문제로 관내 검사장치 투입과 같은 직접적인 검사 방법의 수행이 제한되어 왔다. 원격장 와전류 방법은 시스템 구성이 용이하고 내 외부 부식 결함에 대한 정량적인 평가가 가능하기 때문에 경제성 있는 장치 개발이 가능하다. 본 연구에서는 원격장 와전류 기술을 이용하여 상수도 관망의 특성을 고려한 매설 배관 검사시스템 개발을 수행하였다. 세부적으로는 관내 투입 원격장 와전류 검사의 기구부 설계 및 제작, 원격장 와전류 신호의 획득 및 처리 프로그램 개발, 그리고 개발 장치의 운용 방법 및 절차 검토 등으로 되어 있다.

  • PDF

자기포화 와전류기법에 의한 자성 튜브 비파괴검사 (Nondestructive Examination of Ferromagnetic Tube Using Magnetic Saturation Eddy Current Technique)

  • 이희종;조찬희;송석윤;지동현;정지홍
    • 비파괴검사학회지
    • /
    • 제28권5호
    • /
    • pp.407-415
    • /
    • 2008
  • 원전 발전소 터빈계통을 구성하는 열교환기 튜브는 일반적으로 구리합금, 스테인리스강, 탄소강, 티타늄합금 등의 재질로 제작된다. 이들 재질중에서 페라이트계 type-439 스테인리스강은 자성 재질로서 오스테나이트계보다 더 높은 열전달율 가지며, 부식에 의해 유발되는 결함에 대해 더 높은 저항성을 가진다. 페라이트계 스테인리스강은 보통 발전소 열교환기의 저압급수가열기와 습분분리재열기에 사용된다. 저압급수가열기는 일반적으로 두께가 얇은 type-439 스테인리스강을 이용하는 반면에 습분분리재열기는 더 두꺼운 핀튜브를 사용한다. 이와 같이 터빈 습분분리재열기 튜브로 사용되는 type-439 스테인리스강 핀튜브는 터빈계통의 운전으로 인하여 손상이 발생할 수 있다. 손상에 의한 가장 대표적인 결함은 진동에 의해 발생할 수 있는 마모, 피로균열 등이며 마모성 결함은 일반적으로 튜브-튜브지지판에서 발생되는 것으로 보고되고 있다. 본 연구에서는 type-439 스테인리스강 자성체 튜브에 발생할 수 있는 결함을 검출하고 크기를 측정할 수 있는 자기포화 와전류탐상검사 기법의 능력을 평가하였다.

CA저장고의 작동 환경에 따른 감모율 예측 (Weight Loss Prediction by Operating Conditions of CA Storage)

  • 박천완;박석호;김진세;최동수;김용훈;이수장
    • 산업식품공학
    • /
    • 제21권4호
    • /
    • pp.312-317
    • /
    • 2017
  • 감모율에 영향을 주는 인자를 파악하고 온습도 변화, 제상수, VPD방법을 이용해 감모율을 예측하였으며 실제 감모율과 비교분석을 진행하였다. 저장고 내부의 습도변화를 이용하여 예측한 결과 질소주입과정보다 유닛쿨러의 운전과정에서 발생하는 응축 결상 수분배출 과정이 지배적인 영향을준다. 또한 온습도를 이용한 감모율 예측방법이 실제 감모율과 가장 근사값을 나타냈다. 제상수를 이용해 예측한 결과 감모량은 유닛쿨러의 운전율이 높아질수록 많아졌으며 온습도를 이용한 예측방법보다 운전특성에 따른 감모율 변화가 더 뚜렷하게 나타났다. 이때 유닛쿨러의 운전율은 외기온도와 비례하였으며, 저장고 내부에서 응축된 수분량의 계측이 어렵기 때문에 실제 감모율과 오차가 발생한 것으로 보인다. VPD를 이용한 감모율 예측은 증산계수(K-value)의 영향이 지배적이며, 보고되어진 본 연구에서 이용한 후지사과의 증산계수값(42)에 대한 검증이 필요하다. 본 연구에서 후지사과의 K-value를 30으로 수정하였을 때 가장 근사한 예측값을 계산할 수 있었다.

싸이클론 재순환, 냉각공정을 이용한 공정가스 정제 연구 (Process gas purification using cyclone recirculation and cooling process)

  • 김주회;조우진;최영태;조영민;김상범
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.25-33
    • /
    • 2018
  • 화석 연료의 고갈과 온난화 현상으로 인해 새로운 에너지원에 대한 관심이 급증하고 있다. 그 중에서 바이오가스는 유기성 폐기물 및 바이오매스를 혐기성 소화과정인 가수분해(hydrolysis), 산발효(acidogenesis), 유기산발효(acetogenesis), 메탄발효(methanogenesis)의 단계를 거쳐 발생되기 때문에 친환경적인 에너지자원으로 각광받고 있다. 그러나 바이오가스는 기존의 정제설비로는 제거할 수 없는 높은 미세분진 및 수분 함량으로 인해, 직접연소, 도시가스, 자동차용 연료 등 효율적인 이용을 위해서 정제시스템이 필요하다. 따라서 본 연구는 미세분진과 수분을 동시에 제거할 수 있는 정제과정의 전처리 방법으로써 원심력을 이용하는 냉각공정을 설계하였다. 원심력을 이용하여 분진을 제거하는 Cyclone 내 외부에 열교환기와 ID fan을 구성하여 주입되는 가스를 어는점 이하로 냉각시킴으로써 물안개를 형성시켜 분진입자를 제거하고, 일부 가스를 ID fan을 이용하여 재순환시켜 제거하는 고효율 냉각제어공정을 개발하였다. 수분제거는 유량(25~150L/min) 및 상대습도(60~95%)의 조건에서 시험하였다. 수분제거율은 상대습도 $95{\pm}5%$일 때 평균 80.8%, 입자제거율은 입자크기 $2.5{\mu}m$에서 평균 99.78%의 제거효율을 보였고, 수분과 입자의 동시제거효율은 수분 70.86%, 입자 99.67%의 평균값을 보여주었다.