• Title/Summary/Keyword: Output voltage control

Search Result 1,958, Processing Time 0.042 seconds

Comparison of Voltage Oriented Control and Direct Power Control under Command Mode Transition for PMSG Wind Turbines

  • Kwon, Gookmin;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.173-174
    • /
    • 2016
  • This paper proposes a comparison of Voltage Oriented Control (VOC) and Direct Power Control (DPC) under command mode transition for PMSG Wind Turbines (WT). Based on a neutral point clamped three level back to back type Voltage Source Converter (VSC), proposed control scheme automatically control the generated output power to satisfy a grid requirement from the hierarchical wind farm controller. Automatic command mode transition based on the dc-link voltage error provides a command mode changing between grid command and MPPT mode. It is confirmed through PLECS simulations in Matlab. Simulation result shows that proposed control scheme of VOC and DPC achieves a much shorter transient time of generated output power than the conventional control scheme of MPPT with optimal torque control and VOC under a step response. The proposed control scheme makes it possible to provide a good dynamic performance for PMSG wind turbines in order to generate a high quality output power.

  • PDF

LLC Resonant Converter Operating over a Wide Output Voltage Range by Varying the Input Voltage and Changing Operating Modes (입력전압 가변 및 동작 모드 변화를 통해 넓은 출력전압 범위에서 동작하는 LLC 공진컨버터)

  • Lee, Ji-Cheol;Joo, Jong-Seong;Heo, Ye-Chang;Marius, Takongmo;Kim, Eun-Soo;Jeon, Yong-Seog;Kook, Yoon-Sang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.517-526
    • /
    • 2017
  • In this paper, we propose an LLC resonant converter that operates over a wide controllable output voltage ($50V_{DC}$ to $800V_{DC}$) and shows high efficiency characteristics under all load conditions and output voltages. Two 3.3kW prototypes are designed for an experimental comparison between the variable frequency control (control scheme 1) and the variable input voltage($V_{IN}$) control (control scheme 2) mechanisms. The experimental results show that the variable input control mechanism demonstrates high efficiency under all loads and output voltages.

A Novel Topology Structure and Control Method of High-Voltage Converter for High-Input-Voltage Applications

  • Song, Chun-Wei;Zhao, Rong-Xiang;Zhang, Hao
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.79-84
    • /
    • 2012
  • In this paper, a three-phase high-voltage converter (HVC), in which the main structure of each phase is composed of a cascaded PWM rectifier (CPR) and cascaded inverter (CI), is studied. A high-voltage grid is the input of the HVC. In order to ensure proper operation of the HVC, the control method should achieve output voltage sharing (OVS) among the rectifiers in the CPR, OVS among the inverters in the CI, and high power factor. Master-slave direct-current control (MDCC) is used to control the CPR. The ability of the control system to prevent interference is strong when using MDCC. The CI is controlled by three-loop control, which is composed of an outer common-output-voltage loop, inner current loops and voltage sharing loops. Simulation results show low total harmonic distortion (THD) in the HVC input currents and good OVS in both the CPR and CI.

THE EFFECTIVE VOLTAGE CONTROL SCHEME OF THE INVERTER FOR A STATIC POWER SUPPLY

  • Kim, Byoungjin;Song, Youngsin;Ji, Myoungku;Lee, Jongha;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.336-340
    • /
    • 1998
  • In this paper, an effective control scheme of a single phase UPS inverter is proposed to have no steady state error of the output voltage and the fast response for the load request. The cosine wave tranfer function is proposed to control the output voltage. This controller clearly removes errors of magnitude and phase both in the steady state. On the other hand, a current controller is proposed to reduce the transient time of the voltage control and to improve the bad distorted factor of the output voltage waveform by the load fluctuation and the presences of nonlinear parameters in the plant. The current controller is designed parallel to the voltage controller and performs separately from it.

  • PDF

Voltage Distortion Suppression for Off-grid Inverters with an Improved Load Current Feedforward Control

  • Geng, Yiwen;Zhang, Xue;Li, Xiaoqiang;Wang, Kai;Yuan, Xibo
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.716-724
    • /
    • 2017
  • The output voltage of an off-grid inverter is influenced by load current, and the voltage harmonics especially the 5th and 7th are increased with nonlinear loads. In this paper, to attenuate the output voltage harmonics of off-grid inverters with nonlinear loads nearby, a load current feedforward is proposed. It is introduced to a voltage control loop based on the Positive and Negative Sequence Harmonic Regulator (PNSHR) compensation to modify the output impedance at selective frequencies. The parameters of the PNSHR are revised with the output impedance of the off-grid inverter, which minimizes the output impedance of the off-grid inverter. Experimental results verify the proposed method, showing that the output voltage harmonics caused by nonlinear loads can be effectively suppressed.

Three-Phase Z-Source PWM Rectifier Based on the DC Voltage Fuzzy Control (직류전압 퍼지 제어 기반의 3상 Z-소스 PWM 정류기)

  • Qiu, Xiao-Dong;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.466-476
    • /
    • 2013
  • This paper describes a fuzzy control method to control the output voltage of the three-phase Z-source PWM rectifier. A fuzzy control system is a control system based on fuzzy logic, and the fuzzy controller uses a single input fuzzy theory with its fuzzification. Analytical structure of the simplest fuzzy controller is derived through the triangular membership functions with its fuzzification. By setting the membership functions of the fuzzy rules, fuzzy control is achieved. The PI portion of the output DC voltage controller is controlled by fuzzy method. To confirm the validity of the proposed method, the simulation and experiment were performed, The simulation is performed with PSIM and MATLAB/SIMULINK. For the experiment, we used a DSP(TMS320F28335) controller to compute the reference value and generate the PWM pulses. For the transient state performance of the output DC voltage control of Z-source PWM rectifier, the PI controller and fuzzy controller were compared, also the conventional PWM rectifier and Z-source PWM rectifier were compared. From the results, the Z-source rectifier could allow to buck or boost of the output DC voltage. Through the analysis of the transient state, we could observe that the fuzzy controller has better performance than the conventional PI controller.

A Study on the Affected of DC-Link Voltage Balance Control of the Vienna Rectifier Linked With the Input Series Output Parallel LLC Converter (직렬 입력 병렬 출력 연결된 LLC 컨버터를 갖는 비엔나 정류기의 DC 링크 전압 평형 제어에 관한 연구)

  • Baek, Seung-Woo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.205-213
    • /
    • 2021
  • Due to the advantage of reducing the voltage applied to the switch semiconductor, the input series and output parallel combination is widely used in systems with high input voltage and large output current. On the other hand, the LLC converter is widely used as a high-efficiency power converter, and when connected by ISOP combination, there is a possibility that input voltage imbalance may occur due to a mismatch of passive devices. To avoid damaging the switching device, this study analyzed the DC-link voltage imbalance of a high-capacity supply using an ISOP LLC converter. In addition, the case where DC-link unbalance control was applied and the case not applied was analyzed respectively. Based on this analysis, an initial start-up algorithm was proposed to prevent input power semiconductor device damage due to DC-link over-voltage. The effectiveness of the proposed algorithm has been verified through simulations and experiments.

A Quasi Z-Source AC-AC Converter with a Low DC Voltage Distribution Capability Operating as a Power Electronic Transformer (전력전자 변압기로 동작하는 저전압 직류배전 기능을 갖는 Quasi Z-소스 AC-AC 컨버터)

  • Yoo, Dae-Hyun;Oum, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.358-366
    • /
    • 2014
  • This paper proposes a quasi Z-source AC-AC converter with the low DC voltage distribution capability operating as a power electronic transformer. The proposed system has configuration that the input terminals of two quasi Z-source AC-AC converters are connected in parallel, also their output terminal are connected in series. Simple control method of duty ratio was proposed for the in phase buck-boost AC voltage mode and the DC output voltage control. DSP based experiment and PSIM simulation were performed. As a result, the PSIM simulation results were same with the measured results. By controlling the duty ratio under the condition of 100 [${\Omega}$] load, quasi Z-source AC-AC converter could buck and boost the AC output voltage in phase with the AC input voltage, and the same time, the constant DC voltage could be output without affecting the AC output characteristics. And, the DC output voltage 48[V] was constantly controlled in dynamic state in case while the load is suddenly changed ($50[\Omega]{\rightarrow}100[\Omega]$). From the above result, we could know that the quasi Z-source AC-AC converter can act as a power electronic transformer with a low DC voltage distribution capability.

Fabrication of the SVR with the Improved Voltage Regulating Characteristics by the Structural Modification of the Output Wire Moving Shaft (출력선가동자의 구조변경에 의해 향상된 전압제어 특성을 갖는 SVR의 제작)

  • 홍성훈;강문성
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.10
    • /
    • pp.867-873
    • /
    • 2002
  • We have designed and fabricated the slidacs type automatic voltage regulator(SVR) that is able to control the output voltage continuously according to load variation. Especially, the frictions between the surface of contact of the slidacs coils and the output wire moving shaft arc reduced by modifying the mechanical configuration of surface of contact of slidacs from the conventional sliding one into the proposed rotary one composed of cylindrical bearing. Thus, SVR using cylindrical bearing proposed in this study has less noise than the conventional one owing to the reduction of friction, and its breakdown ratio caused by the abrasion of contact materials is reduced as well. We have designed U motor driving circuit for controlling the output wire moving shaft, and introduced the digital control method using the pulse width modulation(PWM) output for controlling DC motor.

Characteristic Comparison between PI and Hysteresis Voltage Control of High Voltage Unidirectional Inverter for Piezoelectric Load using FPGA (FPGA를 이용한 피에조 부하 구동용 고전압 단방향 인버터의 PI 및 히스테리시스 전압 제어 특성 비교)

  • Kim, Ki-Seok;Cho, Yong-Ho;Kim, Hyeong-Seop;Kang, Tae-Sam;Hong, Sun-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.48-54
    • /
    • 2017
  • In this paper, hysteresis voltage control method is proposed to an unidirectional inverter control for piezoelectric load. Piezoelectric load has electrically RC characteristic, and is driven by the inverter to control the output voltage waveform. When controling the output waveform by PI control, appropriate gains need to be selected. However, hysteresis control may minimize the output distortion because it has maximum proportional gain. In addition, Hysteresis control algorithm has simple structure to realize and the response is fast. Although the switching frequency of the inverter by hysteresis control varies, the switching frequency for the piezoelectric load is lower than that by PI control for equivalent performance. In particular, on implementing the algorithm using FPGA, the algorithm can be implemented in fewer pabrics and the processing time can be reduced. The superiority of the proposed hysteresis voltage control was proved for piezoelectric load through simulation and experiment.