• 제목/요약/키워드: Output sound pressure

Search Result 59, Processing Time 0.025 seconds

ITE Hearing Aid Specification Testing Devise Development using Probe Microphones (프로브 마이크로폰을 사용한 귓속형 보청기 성능 검사장치 개발)

  • 장순석;권유정
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1044-1047
    • /
    • 2003
  • An acoustic testing device composed of 2 probe microphones was developed for the electro-acoustic specification testing of the ITE (In-The-Ear) hearing aid (HA). The amplitude ratio and the phase difference between the incident pressure onto the HA microphone and the outward pressure of the HA receiver were measured by the present acoustic system. The microphones were particularly used because of small acoustic cavities where input and output pressures were present. The acoustic wall composed of clay completely blocks the propagation of the sound pressure between the small acoustic cavities. The system has an advantage of structural flexibility for the acoustic testing of different sizes and shapes of ITE-type HAs.

  • PDF

Output Improvement of Two-dimensional Audio Actuators by Corona Surface Treatments to Increase Adhesive Properties of Piezoelectric Materials (코로나 표면 처리의 접착력 향상에 의한 이차원 오디오 시스템의 출력 개선)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.91-97
    • /
    • 2012
  • Recently, the performances of electrical and electronic devices are improving while the sizes are becoming smaller. As sound-generating systems, the two-dimensional speakers have been developed in place of conventional three-dimensional ones. Piezoelectric materials show the mechanical vibrations due to the voltage applied from outside the materials. The early film speakers had a limitations of output power in that it was not easy to make the conducting macromolecular films on the surfaces of the materials due to the internal chemical properties of materials. We have adopted the corona surface treatment in order to improve the output characteristics by increasing the adhesion of the coating material on to the surface of the center material of piezo film. The results showed the improvement of output power in the wider range of operating frequencies.

A Physical Ear Model for Evaluating Hybrid-acoustic Sensor Characteristics of Fully Implantable Middle-ear Hearing Aid (완전 이식형 인공중이의 하이브리드 음향센서 특성 평가를 위한 귀 물리모델)

  • Shin, Dong Ho;Moon, Ha Jun;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.8
    • /
    • pp.923-929
    • /
    • 2019
  • In this paper, biomimetic based physical ear model proposed for measuring the characteristics of a hybrid-acoustic sensor for fully implantable middle-ear hearing aid. The proposed physical ear model consists of the external ear, middle-ear, and cochlea. The physical ear model was implemented based on the anatomical structure and CT images of the human ear. To confirm the characteristics of the ear model, the vibrational characteristics of the stapes was measured after applying sound pressure to the tympanic membrane. The measured results were compared with the vibrational characteristics of the human temporal bone specified by ASTM F2504-05. Through the comparison results, the feasibility of the proposed ear model was confirmed. Then, after attaching the hybrid-acoustic sensor to the ear model, the output characteristics of the ECM and acceleration sensor were measured according to the sound pressure. The measured results were compared with previous studies using human temporal bone, and the usefulness of the proposed physical ear model was verified through the analysis results.

Design of a Multimode Type Ring Vector Sensor (다중 모드형 링 벡터 센서의 설계)

  • Lim, Youngsub;Joh, Cheeyoung;Seo, Heeseon;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.484-493
    • /
    • 2013
  • Typical underwater acoustic sensors can measure the scalar quantity of sound-pressure-magnitude with the limitation of being unable to identify the direction of an incoming wave. This paper proposes a method to detect the direction of the sound wave with a ring sensor. The sensor of the proposed structure has a piezoceramic ring divided into eight elements, and distinguishes the direction of the sound wave by properly combining the output voltages of the piezoceramic elements. Further, through the analysis of the effects of the structural parameters like the ring radius and length, and piezoceramic thickness, we have suggested the way to improve the sensitivity of the vector sensor.

Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation (기준음원의 교정 절차 개발 및 불확도 평가 사례)

  • Jae-Gap Suh;Wan-Ho Cho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.344-350
    • /
    • 2024
  • A Reference Sound Source (RSS) is an important standard device employed in measuring sound power. The specifications of RSS is specified in international standards, and it is classified as a major calibration item in the field of acoustic metrology. Since the output power of RSS is affected by the supply voltage, each country needs to secure its own calibration service system. In this study, a procedure for calibrating a RSS is established based on the reverberant room conditions and uncertainty evaluation is conducted. Basically, the calibration procedure can apply a precision measurement process of acoustic power, and here, the measurement method using the reverberation chamber of ISO 3741 is applied. For this purpose, a measurement system is constructed, measurements are conducted with two types of RSS, and measurement uncertainty is evaluated. Through measurement examples, it is confirmed that the non-uniformity of the sound pressure distribution in the reverberation room and the volume measurement uncertainty contributed significantly to the overall uncertainty. Additionally, the influence of input voltage is experimentally examined to examine the uncertainty contribution that can be reflected in acoustic power measurements.

Analysis of Frequency Response Characteristics in Optical Microphone (광 마이크로폰의 주파수 응답특성 분석)

  • Yeom, Keong-Tae;Kim, Kwan-Kyu;Heh, Do-Geun;Kim, Yong-Kab
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.6
    • /
    • pp.8-15
    • /
    • 2008
  • In this paper, in order to analyze property of frequency response in optical microphone, system was implemented. The capacitance microphone and fiber-optic transmission path type fiber-optic microphone (FOM) have weaknesses in directivity, size, weight, and price. However suggested optical microphone can be constituted by cheap devices, so it has many benefits like small size, light weight, high directivity, etc. Head part of optical microphone which is suggested in this paper is movable back and forth by sound pressure with the attached reflection plate. Operating point is determined by measuring the respond characteristics and choosing the point on which has maximum linearity and sensitivity while changing the distance between optical head and vibrating plate. We measured the output of the O/E transformed signal of the optical microphone while frequency of sound signal is changed using sound measurement/analysis program, Smaart Live and USBPre, which are based on PC, and compared the result from an existing capacitance microphone. The measured Optical microphone showed almost similar output characteristics as those of the compared condenser microphone, and its bandwidth performance was about 300[Hz]-3[kHz] at up to 3 [dB].

Study of Optimum Operating Conditions of Thermal Acoustic Generator (열음향파 발생장치의 최적 작동 조건에 대한 실험적 연구)

  • Shin, Sang Woong;Oh, Seung Jin;Lee, Yoon Joon;Kim, Nam Jin;Chun, Wongee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.131-137
    • /
    • 2013
  • This study deals with the effects of major geometric parameters on the sound wave output of a thermal acoustic system. The output power of the acoustic wave was dependent on the stack position, stack length, resonator tube length, and input power. In experiments, the maximum SPL was generated when the stack was placed between one-fourth to half, resonator and stack length were longer, and input power was increased. The frequency was recorded to be 437 and 885 Hz when the resonator tube length was 200 and 100 mm, respectively. Therefore, when the resonator tube length was shorter, a higher frequency was recorded.

미세 압전 캔틸러버를 이용한 마이크로 폰 및 마이크로 스피커

  • 이승섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.347-351
    • /
    • 1997
  • A micromachined piezoelectic cantilever transducer,which works both as a microphone and as a microspeaker,has been fabricated and tested. The 2000*2000*3.mu.m .sap2. cantilever has oxide(ZnO)piezoelectric thin film on a supporting layer of low-pressure chemical-vapor-deposited(LPCVD)low-stress siliconnitride. A highlight of the fabrication process which may also be relevant for other micromachined stuctures is the technique for producing a flat,multilayer cantilever. The measured microphone sensitivity is fairly constant at 2 mV/.mu.bar in the low frequency range and rise to 20 mV/.mu.bar at the lowest resonant frequency of 890 Hz. The 2 mV/.mu.bar sensitivity is the highest report to data for a microphone with a micromachined diaphragm. When measured into a 2 cm/sap3 coupler with 4V (zero-park)drive,the microspeaker output sound pressure level(SPL) is 75 dB at 890 Hz. It increases to approximately 100dB SPL at 4.8kHz with 6V(zero-park)drive. The measured microphone frequency response agrees well with the results of an ABAQUS simulation.

Acoustic Characteristic of Emergency Broadcasting Speakers (비상방송용 스피커의 음향 특성 비교)

  • Jeong, Jeong-Ho;Seo, Bo-Youl;Park, Kye-Won;Shin, Yi-Chul;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.130-137
    • /
    • 2019
  • In this study, the acoustic characteristics of 13 types of emergency broadcasting speakers were tested under the test set-up of UL 2043 and compared. When the sound pressure level of 1 W speakers was compared with speakers with a 15 W output, the SPL of the 15 W speakers was approximately 20 dB higher in some frequency bands. Loudness analysis showed that people can recognize emergency sound from a 15 W speaker twice as loud as the emergency sound from 1 W speakers. The analysis results on the articulation index (room) had an opposite tendency with loudness results, meaning that small speakers can generate clearer sound. Therefore, it is necessary to improve emergency broadcasting speakers to generate louder and clearer sound. Moreover, a performance evaluation standard is needed based on the reasonable and quantitative measurements and evaluations of the acoustic characteristics of the emergency-broadcasting speakers so that a sufficient and clear sound can be generated in various spaces. In addition, it is necessary to establish standards for the clarity of emergency broadcasting in various spaces.

Design of a Multimode Piezoelectric Spherical Vector Sensor for a Cardioid Beam Pattern (심장형 빔 패턴을 위한 다중모드 압전 구형 벡터센서 설계)

  • Lim, Youngsub;Lee, Jaeyoung;Joh, Cheeyoung;Seo, Heeseon;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.32-42
    • /
    • 2013
  • Typical underwater piezoelectric spherical sensors are omni-directional, thus can measure the scalar quantity sound-pressure-magnitude only with the limitation not being able to measure the direction of the incoming wave. This paper proposes a method to simultaneously measure both the magnitude and direction of the sound wave with the spherical sensor. The method divides the piezoceramic sphere of the sensor into eight elements, and distinguishes the magnitude and direction of the sound pressure by combining the output voltage of the elements in a particular manner. Further, through the analysis of the sensitivity variation in relation to the structural parameters like radius and thickness of the piezoceramic sphere, we have suggested the way to improve the sensitivity of the vector sensor.