• 제목/요약/키워드: Output index

검색결과 671건 처리시간 0.032초

The Algorithms for Controlling AC Output Voltage of Z-Source Inverter Using Modified SVPWM

  • Tran Quang-Vinh;Chun Tae-Won;Son Jang-Kyung;Hee Lee-Hong;Ahn Jung-Ryol
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 추계학술대회 논문집
    • /
    • pp.64-69
    • /
    • 2004
  • This paper deals with an algorithm for controlling ac output voltage of Z-source inverter using Modified SVPWM (abbreviated as MSVPWM). Unlike the conventional space vector pulse width modulation, MSVPWM has one extra shoot-through zero time $T_{sh}$. During shoot-through zero time, both switches in a leg are conducted simultaneously in order to boost inverter output voltage to any desirable value regardless the line voltage. The algorithm to control linearly the capacitor voltage is suggested to improve the performance of Z-source inverter system. The performance of Z-source inverter using above algorithms is demonstrated in simulation results using PSIM. Index terms-Z-source inverter (ZSI), shoot-through time, three-phase carrier-based PWM, space vector PWM (SVPWM), modified space vector PWM (MSVPWM).

  • PDF

Feasibility study of bonding state detection of explosive composite structure based on nonlinear output frequency response functions

  • Si, Yue;Zhang, Zhou-Suo;Wang, Hong-fang;Yuan, Fei-Chen
    • Steel and Composite Structures
    • /
    • 제24권4호
    • /
    • pp.391-397
    • /
    • 2017
  • With the increasing application of explosive composite structure in many engineering fields, its interface bonding state detection is more and more significant to avoid catastrophic accidents. However, this task still faces challenges due to the complexity of the bonding interface. In this paper, the concept of nonlinear output frequency response functions (NOFRFs) is introduced to detect the bonding state of explosive composite structure. The NOFRFs can describe the nonlinear characteristics of nonlinear vibrating system. Because of the presence of the bonding interface, explosive composite structure itself is a nonlinear system; when bonding interface of the structure is damaged, its dynamic characteristics show enhanced nonlinear characteristic. Therefore, the NOFRFs-based detection index is proposed as indicator to detect the bonding state of explosive composite pipes. The experimental results verify the effectiveness of the detection approach.

신안풍력발전소 풍력터빈의 성능저하 분석 (Analysis on Wind Turbine Degradation of the Shinan Wind Power Plant)

  • 김현구
    • 한국태양에너지학회 논문집
    • /
    • 제33권4호
    • /
    • pp.46-50
    • /
    • 2013
  • This paper investigated wind turbine degradation quantitatively by analyzing the short-term operation records of the Shinan Wind Power Plant. Instead of a capacity factor which is needed to be normalized its variability due to monthly wind speed change, this study suggests an analysis method by taking the difference between the theoretical power output calculated from the nacelle wind speed and actual power output as the quantitative index of performance degradation. For three-year SCADA data analysis of the Shinan Wind Power Plant, it was confirmed that power output degradation rate of 0.54% per year. This value is within the average reduction rate 0.4%/year~0.9%/year of normalized capacity factor of the onshore wind power plants in U.K. and Denmark; however, lower than the rate 2%/year of Canadian wind power plants.

CIPP 모형을 적용한 창의·인성교육 평가준거 및 지표의 탐색 (Exploration of the Evaluation Criteria and Index by Applied CIPP Model in Creativity·Character Education)

  • 원효헌;전은순
    • 수산해양교육연구
    • /
    • 제26권5호
    • /
    • pp.1108-1118
    • /
    • 2014
  • The purpose of this study was to spread the education of human creativity program and its possibility of consistency, and its application to school system by exploring the evaluation system that determines the valuable and useful decisions. This study was based on the evaluation system according to CIPP model regarding the program's general ideas and its role. The interest of the education of human creativity was increasing as well as its progress of program, and we searched 13 figures and 55 evaluation index according to increase the program's effectiveness and nation-wise situation of evaluation model. The conclusion of this study was that the human creativity program's evaluation was composed of six compartments. And the context evaluation was composed of three evaluation models and eleven index, and input evaluation was composed of three evaluation model and 15 index, while process evaluation is composed of three evaluation models and thirteen evaluation index. Lastly, output evaluation had four evaluation model and sixteen index.

Are Trades Related to Technology? Evidences From The Baltic States: Estonia, Latvia and Lithuania

  • MUCHDIE, Muchdie;NARMADITYA, Bagus Shandy
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제6권2호
    • /
    • pp.83-93
    • /
    • 2019
  • This paper provides empirical evidences from the Baltic States on the relationship between technology and trades. In this study, regression and correlation analysis were employed an attempt to reveal the relationship between technology index and net-export coefficient, as well as the relationship between technology index and import coefficient. In this research, technology level was measured by technology index, while trades included of domestic and foreign trades; export and import. The data used for this study were collected from world input-output databases of Estonia, Latvia and Lithuania for the period 2000, 2005, 2010, and 2014. The findings remarked that the relationship between technology and domestic trade was positive and statistically significant. The result of the study implies that the higher was the technology index leads to the higher domestic transaction. Furthermore, relationship between technology and net-export was unpredictable. In year 2000, data from Estonia and Latvia showed that the relationship between variables was negative and in other years of the study, the relationship was positive. However, the relationship between variables was not statistically significant. Lastly, the relationship between technology and import was negative and statistically significant. It implies that the higher was technology index, will have a consequence the smaller was import.

전기자동차용 유도전동기를 위한 유한제어요소 모델예측 토크제어 (Finite Control Set Model Predictive Control with Pulse Width Modulation for Torque Control of EV Induction Motors)

  • 박효성;고병권;이영일
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2189-2196
    • /
    • 2016
  • This paper proposes a new finite control set-model predictive control (FCS-MPC) method for induction motors. In the method, the reference state that satisfies the given torque and rotor flux requirements is derived. Cost indices for the FCS-MPC are defined using the state tracking error, and a linear matrix inequality is formulated to obtain a proper weighting matrix for the state tracking error. The on-line procedure of the proposed FCS-MPC comprises of two steps: select the output voltage vector of the two level inverter minimizing the cost index and compute the optimal modulation factor of the minimizing output voltage vector in order to reduce the state tracking error and torque ripple. The steady state tracking error is removed by using an integrator to adjust the reference state. The simulation and experimental results demonstrated that the proposed FCS-MPC shows good torque, rotor flux control performances at different rotating speeds.

평면형 병렬 메카니즘의 국소적 제어 특성에 관한 연구 (A study on the control-in-the-small characteristics of a planar parallel mechanism)

  • 김희국;조황;김재섭
    • 제어로봇시스템학회논문지
    • /
    • 제4권3호
    • /
    • pp.360-371
    • /
    • 1998
  • In this paper, output precision characteristics of a planar 6 degree-of-freedom parallel mechanisms are investigated, where the 6 degree-of-freedom mechanism is formed by adding an additional link along with an actuated joint in each serial subchain of the planar 3 degree-of-freedom parallel mechanism. Kinematic analysis for the parallel mechanism is performed, and its first-order kinematic characteristics are examined via kinematic isotropic index, maximum and minimum input-output velocity transmission ratios of the mechanisms. Based on this analysis, two types of planar 6 degrees-of-freedom parallel manipulators are selected. Then, dynamic characteristics of the two selected planar 6 degree-of-freedom parallel mechanisms, via Frobenius norms of inertia matrix and power modeling array, are investigated to compare the magnitudes of required control efforts of both three large actuators and three small actuators when the link lengths of three additional links are changed. It can be concluded from the analysis results that each of these two planar 6 degrees-of-freedom parallel mechanisms has an excellent control-in-the-small characteristics and therefore, it can be very effectively employed as a high-precision macro-micro manipulator when both its link lengths and locations of small and large actuators are properly chosen.

  • PDF

공공부문의 서비스효율성 측정 및 지수개발에 관한 연구 (A Study on the Development of PSEI and Measurement of Service Efficiency in Public Sector)

  • 송광석;백필기;유한주
    • 품질경영학회지
    • /
    • 제37권4호
    • /
    • pp.100-110
    • /
    • 2009
  • The customer-driven efficiency evaluation has been in the mainstream of public administration research, since the 1980s. However, there have been relatively fewer efficiency evaluation research in public administration compared to those of public institutions. This paper is to analyze the service efficiency of public sector using Data Envelopment Analysis(DEA). We suggested two stage DEA model to accomplish efficiency evaluation that an operation and performance characteristic of the public institution were reflected and then the number of the government employee and tax expenditure per residents were used as the input elements at the 1st stage and four integrated service dimensions were used as the output elements. At 2nd stage, four integrated service dimensions and citizen's satisfaction were used as the input and output elements respectively. In addition, we suggested PSEI(Public Service Efficiency Index) which showed the efficiency of the public sector using the two stages efficiency result. According to the results for '07, there were no efficient institutions among 15 DMUs and the most efficient public institution was K(0.9150). In case for '08 analysis, there was only one efficient DMU.

개심술을 받은 환자의 체위에 따른 심박출량 및 불편감에 관한 연구 (Effects of changing position on cardiac output & on patient's discomforts after cardiac surgery)

  • 유미;권은옥;최윤경;강현주;오세은
    • 기본간호학회지
    • /
    • 제7권2호
    • /
    • pp.256-270
    • /
    • 2000
  • Invasive hemodynamic monitoring has become a valuable assessment parameters in critical care nursing in patients undergoing open heart surgery patients. During cardiac surgery, the Swan Ganz catheter is placed in the pulmonary artery. Critical care nurses routinely obtain cardiac output, cardiac index, and pulmonary arterial pressure in these patients. Traditionally, patients are positioned flat and supine for cardiac output measurement. Numerous studies have dealt with the effects of changing position on the hemodynamic variables. However, there are a few studies dealing with patients who undergo cardiac surgery in Korea. Thus, the purpose of this study was to determine the effects of changing position on cardiac output, PAP, CVP, BP, HR and discomfort in patients after cardiac surgery. A sample of 21 adults who had CABG and/or valve replacement with Swan Ganz catheters in place was studied. The data were collected in the cardiac ICU of a university hospital in Seoul during the period from July 28, 1999 to August 30. 1999. In this study, the independent variable is patient position in the supine, 30 degree, and 45 degree angles. Dependent variables are C.O., C.I., CVP, PAP, MAP, HR and patients' perceived discomforts. Subject discomfort was measured subjectively by visual analogue scale. Other hemodynamic data where collected by the thermodilution method and by direct measurement. The data were analyzed by percentile, t-test, ANOVA, Linear regression analysis using SPSS-/WIN program. The results are as follows : 1) Changes in cardiac output were absent in different angle positions, 0, 30. 45 degrees(F=.070, P=.932). Changes in cardiac index were absent in different angle positions, 0. 30, 45 degrees(P>.05). 2) Changes in central venous pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 3) PAP had no change in different angle 0, 30, 45 degree positions; systolic PAP(P>.05), diastolic PAP(P>.05). 4) Changes in systolic blood pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 5) Changes in heart rates were absent in different angle positions, 0, 30, 45 degree(P>.05). 6) Patients' perceived discomfort was absent in different angle positions, 0, 30, 45 degree(p<.05). In conclusion, critical care nurses can measure C.O., C.I., PAP, BP, & CVP in cardiac surgery patients at 30 degree or 45 degree positions. This can improve the patients' comfort.

  • PDF

교류측 전압 및 전류 센서가 없는 3상 Z-소스 PWM 정류기의 퍼지-PI 제어 (A Fuzzy-PI Control Scheme of the Three-Phase Z-Source PWM Rectifier without AC-Side Voltage and Current Sensors)

  • 한근우;정영국;임영철
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.767-781
    • /
    • 2013
  • In this paper, we proposes the AC input voltage and current sensorless control scheme to control the input power factor and DC output voltage of the three-phase Z-source PWM rectifier. For DC-link voltage control which is sensitive to the system parameters of the PWM rectifier, fuzzy-PI controller is used. Because the AC input voltage and current are estimated using only the DC-link voltage and current, AC input voltage and current sensors are not required. In addition, the unity input power factor and DC output voltage can be controlled. The phase-angle of the detected AC input voltage and estimated voltage, the response characteristics of the DC output voltage according to the DC voltage references, the FFT results of the estimated voltage and current, efficiency, and the response characteristics of the conventional PI controller and fuzzy-PI controller are verified by PSIM simulation.