Therapeutic Proton Beam Range Measurement with EBT3 Film and Comparison with Tool for Particle Simulation

  • Lee, Nuri;Kim, Chankyu;Song, Mi Hee;Lee, Se Byeong
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.112-119
    • /
    • 2019
  • Purpose: The advantages of ocular proton therapy are that it spares the optic nerve and delivers the minimal dose to normal surrounding tissues. In this study, it developed a solid eye phantom that enabled us to perform quality assurance (QA) to verify the dose and beam range for passive single scattering proton therapy using a single phantom. For this purpose, a new solid eye phantom with a polymethyl-methacrylate (PMMA) wedge was developed using film dosimetry and an ionization chamber. Methods: The typical beam shape used for eye treatment is approximately 3 cm in diameter and the beam range is below 5 cm. Since proton therapy has a problem with beam range uncertainty due to differences in the stopping power of normal tissue, bone, air, etc, the beam range should be confirmed before treatment. A film can be placed on the slope of the phantom to evaluate the Spread-out Bragg Peak based on the water equivalent thickness value of PMMA on the film. In addition, an ionization chamber (Pin-point, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The eye phantom was used for independent patient-specific QA. The differences in the output and beam range between the measurement and the planned treatment were less than 1.5% and 0.1 cm, respectively. Conclusions: An eye phantom was developed and the performance was successfully validated. The phantom can be employed to verify the output and beam range for ocular proton therapy.

산란선 증폭시 차폐체 유무에 따른 선량 분석 (Analyze dosimetry with and without shielding when amplifying scattered rays)

  • 조창호;김정래
    • 문화기술의 융합
    • /
    • 제10권3호
    • /
    • pp.819-825
    • /
    • 2024
  • 진단용방사선발생장치를 사용함에 있어서 선량데이터를 기록하는 이유는 의료진 및 환자의 피폭선량을 기록하고 관리하기 위함이다. 진단용방사선발생장치를 사용함에 있어서 방사선량의 차이를 검증하고 위험성과 차폐체 착용의 유무의 상황에서 피폭선량에 대한 측정과 분석을 통해 사용자의 피폭선량 경감에 대한 인식을 알리고자 하였다. 에스레이튜브와 II튜브에 따라 구분하여 장비를 한국 C-arm 2대, 독일 C-arm 2대장비를 대상으로 각 장비별 선량분석결과 한국 FPD type C-arm 이 가장 높은 선량값이 측정되었고, 독일 I.I type C-arm, 독일 FPD type C-arm, 한국, I.I type C-arm 순서로 피폭선량값이 측정되었다. 차폐체 유무에 따른 피폭선량 분석결과 일반적인 대기상태에 인체팬텀을 놓고 측정결과 산란선에 의해 피폭선량이 약 2배 증가하였으나 차폐체(0.5mm/납앞치마)를 착용하니 약 5배의 피폭선량 감소하는 결과가 나타났다. 피폭선량과 차폐체를 통해 피폭선량의 관리가 중요한 역할을 하며 방사선 피폭을 줄이는 방법을 유추할 수 있다. 또한, 장비마다 출력되는 피폭선량이 다른 특성을 갖고 있음으로 차폐체를 유무를 선별하는데 선량정보로 제공을 할 것으로 기대 한다.

PBG 구조를 이용한 Dual Band 전력증폭기 연구 (Research Dual Band Power Amplifier using PBG Structure)

  • 전익태;서철헌
    • 한국전자파학회논문지
    • /
    • 제15권8호
    • /
    • pp.788-793
    • /
    • 2004
  • 본 논문은 각각 1 W 출력의 5.8 GHz 대역의 무선 랜과 이동통신 서비스 주파수 대역인 1.8 GHz 대역에서 동작하는 이중대역 전력증폭기를 설계 및 제작하였다. 전력증폭기의 입력으로 다중대역 신호가 선택적으로 입력되지 않고 동시에 입력되어질 경우 효과적인 구조로 설계하였다. 입력 단에서 두 신호를 분리하기 위하여 PBG를 이용하여 광대역의 저지 특성을 가지는 Diplexer를 사용하였으며, 전력증폭기의 정합에는 Load-pull 이론을 적용하여 최대 출력을 얻도록 하였다. 전력증폭기의 선형성을 증가시키기 위하여 PBG 구조를 적용하였다. 본 논문은 Load-pull정합부 내에 PBG구조를 삽입하여 전력증폭기가 최대 출력 상태에서 선형성을 개선시켰다. 또한 출력 정합부내에서 PBG 구조의 위치에 따른 선형성 개선의 변화 시뮬레이션을 통해서 검증하였다.

Gafchromic EBT2필름과 다양한 검출기를 이용하여 $3cm^2$ 이하의 소조사면에서 출력비율의 선량검증 (Dosimetric Verifications of the Output Factors in the Small Field Less Than $3cm^2$ Using the Gafchromic EBT2 Films and the Various Detectors)

  • 오세안;예지원;이레나;박헌보;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제25권4호
    • /
    • pp.218-224
    • /
    • 2014
  • 소조사면의 선량검증은 고선량을 1회에 치료하는 정위적방사선수술(Stereotactic radiosurgery, SRS)과 고선량을 소분할 하여 치료하는 소분할방사선치료(hypo-fractionated radiotherapy)에서 작은 크기의 종양을 치료하기 위해서 자주 사용되기 때문에 현대의 방사선치료에서 있어서 매우 중요하다. 그러나, $3cm^2$ 이하의 소조사면에 대한 선량검증은 방사선치료에서 있어서 대단한 도전이다. 소조사면의 선량검증은 (a) 측방전자균형(lateral electronic equilibrium)의 부족, (b) 급격한 선량 기울기(steep dose gradient), (c) 선원의 부분적 차폐 때문에 어렵다. 이 연구의 목적은 6 MV 광자선의 $3cm^2$ 이하의 소조사면에서 출력비율을 다양한 검출기로 측정하고 검증하는 것이다. 출력비율은 CC13 이온함, CC01 이온함, EDGE 검출기, 열발광선량계(thermoluminescence dosimeters, TLD), Gafchromic EBT2 필름을 이용하여 $0.5{\times}0.5cm^2$, $1{\times}1cm^2$, $2{\times}2cm^2$, $3{\times}3cm^2$, $5{\times}5cm^2$, $10{\times}10cm^2$의 다양한 조사면에서 측정하였다. 출력비율의 차이는 조사면의 크기가 작아질수록 검출기간의 차이는 증가하였다. 본 연구의 결과는 $3cm^2$ 이하의 소조사면의 선량측정은 CC01 이온함, EDGE 검출기와 같은 작은 크기의 방사부부피(active volume)를 가지는 검출기를 사용해야 한다는 것을 입증하였다. 또한, $3cm^2$ 이하의 소조사면에서 EDGE 검출기의 출력비율은 Gafchromic EBT2 필름의 결과와 잘 일치하였다.

에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가 (Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device)

  • 주은빈;안소현;조삼주;금기창;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제27권1호
    • /
    • pp.31-36
    • /
    • 2016
  • 본 연구에서는 이중에너지 영상을 획득하는 방법으로, 구리판을 이용한 에너지 변조 필터를 사용하였을 때의 선량을 계산 및 측정하였고, 기존의 다른 방법들과 선량을 비교하였다. 몬테칼로 전산모사를 이용하여 에너지 변조 필터에 의한 선량 변화를 평가하기 위하여 MCNPX를 사용하였다. 두경부, 흉부, 복부 촬영에 주로 사용되는 관전압인 80, 120 kVp에 대한 스펙트럼을 SPEC78 프로그램으로 생성하여 선원을 모사하였고, 구리 물질로 이루어진 에너지 변조 필터(밀도: $8.96g/cm^3$)는 두께를 0.5 mm부터 2.0 mm까지 0.5 mm 간격으로 변화시켜가면서 선원으로부터 20.0 cm 거리에 X-선 창을 절반만 가리도록 모델링 하였다. 몬테칼로 전산모사 값과 실제 선량 값을 비교하기 위해서는 교정 상수가 필요하므로, Gafchromic EBT3 필름에 알고 있는 선량을 조사한 후 판독하여 선량 교정 곡선을 획득하였다. 실험과 동일한 조건으로 MCNPX의 f6 tally로 획득한 결과값과 측정값 간의 선량 환산 인자는 $7.2*10^4cGy/output$으로 구해졌으며, 관전압 80 kVp과 관전류 6 mA의 조건으로 콘빔 CT 촬영 시, 평균 10.1 cGy (표준편차 2.7 cGy) 조사됨을 알 수 있었다. 에너지 변조 필터에 기반한 이중 에너지 영상 획득 기술을 적용한 본 연구에서는 이중 에너지 콘빔 CT 시스템의 선량이 단일 에너지 CT 시스템의 선량보다 33~40% 감소함을 알 수 있다. 또한, 에너지 변조 필터에서 발생한 산란선에 의한 선량 증가 효과는 거의 없었다. 따라서, 인체 내 물질 분별력이 우수하여 임상에 널리 응용되었던 기존 이중 에너지 CT 시스템의 상대적으로 피폭선량이 높다는 단점을 효과적으로 개선할 수 있다.

중재적 시술에 사용하는 조영제의 요오드(53I) 함유량 차이에 따른 피폭선량 평가 (Dose assessment according to Differences in the Content of Iodine in Contrast Media used in Interventional Procedure)

  • 박혁;전주섭;김용완;장성주
    • 한국콘텐츠학회논문지
    • /
    • 제14권3호
    • /
    • pp.337-345
    • /
    • 2014
  • 중재적 시술 및 혈관조영검사에 사용되는 조영제의 요오드 함유량 차이에 따른 흡수도와 피폭선량을 알아보았다. 실험에 사용된 조영제는 요오드 함유량(I $mg/m{\ell}$)에 따라 240, 270, 300, 320, 350, 370, 400의 7종류를 사용하였으며, 그 결과 요오드 함유량이 많을수록 흡수도 및 피폭선량이 높아짐을 알 수 있었으며, TACE 검사에서도 조영제의 농도 270 I $mg/m{\ell}$에 비해 350 I $mg/m{\ell}$의 출력 선량이 8.5% 정도 증가하였다. 본 연구를 통해 조영제가 환자의 피폭선량에 영향을 주며 요오드 함유량이 많은 조영제일수록 환자의 피폭선량이 증가함을 알 수 있었다.

Antigastritic and Antiulcerative Activities of Water Extracts Derived from Scutellaria baicalensis

  • Cho, So-Yean;Lim, Duk-Yun;Kang, Min-Hee;Yoon, Hye-Ran;Kim, Gun-Hee;Lee, Yong-Soo;Jeong, Choon-Sik
    • Biomolecules & Therapeutics
    • /
    • 제14권3호
    • /
    • pp.171-177
    • /
    • 2006
  • Gastritis and gastric ulcer were known to be induced by gastic acid, stress, ethanol, Helicobacter pylori and free radical, etc. This study was performed for the development of a new drug or nutraceutical from medicinal plants or natural products with anti-gastritis, anti-ulcerative and gastroprotective activities. The water extract of Scutellaria baicalensis was exhibited potent inhibition in HCl ethanol-induced gastric lesion, acetic acid-induced and Shay ulcers, indicating the effects on gastric lesion and ulcer in rats. The water extract of Scutellaria baicalensis significantly inhibited HCl ethanol-induced gastric lesions at the oral dose of 300, 500 mg/kg. In pylorus ligated rats, the treatments of the water extract from Scutellaria baicalensis showed decrease in the volume of gastric secretion and acid output and increase pH at oral dose of 300, 500 mg/kg. And significantly reduced acetic acid-induced ulcer at the oral dose of 500 mg/kg for 12 days. In this study, we have found that the water extract from Scutellaria baicalensis had significant improvement in acute gastritis and ulcer at the dose of 300, 500 mg/kg and in chronic gastritis and ulcer at the dose of 500 mg/kg. Also we evaluated the antibacterial activity against Helicobacter pylori treated with Scutellaria baicalensis. Scutellaria baicalensis had a equivalent antibacterial activity with ampicilin against H. pylori at the dose of $100\;{\mu}/ml$. In histological examination, the water extract of Scutellaria baicalensis drastically restored gastric damages induced by HCl ethanol solution, pylorus- ligature and acetic acid. Therefore, we may use the water extract from Scutellaria baicalensis as antigastritic and antiulcerative agent for the purpose of the improvement or treatment of gastritis and gastric ulcer.

Radiation Safety Exploration Using Radio-photoluminescence Dosimeter for Crookes Tubes in Junior and Senior High School in Japan

  • Akiyoshi, Masafumi;Do, Duy Khiem;Yamaguchi, Ichiro;Kakefu, Tomohisa;Miyakawa, Toshiharu
    • Journal of Radiation Protection and Research
    • /
    • 제46권3호
    • /
    • pp.106-111
    • /
    • 2021
  • Background: Crookes tube is utilized in junior high and high schools in Japan to study the character of electrons and current, and not for radiological education. There is no official guideline or regulation for these radiation source to the public. Therefore, most teachers have no information about the leakage of X-rays from Crookes tube. The peak energy of X-rays is approximately 20 keV, and it is impossible to measure using conventional survey meters. Materials and Methods: Each leakage dose of low energy X-rays from 38 Crookes tube in the education field, such as junior and senior high schools in Japan, was explored by the teachers in the school using radio-photoluminescence (RPL) dosimeters. Before and after the measurements, the dosimeters were sent by postal mails. Results and Discussion: At the exploration in this study, it was estimated that the 70 ㎛ dose equivalent, Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes, at the distance of 1 m, where the Crookes tube was usually observed. However, the highest dose was estimated as 0.69 mSv by an equipment with the full power. Furthermore, one Crookes tube exhibited 0.62 mSv with minimum output power of the induction coil. This relatively large dose was reduced by the shorter distance of discharge electrodes of the induction coil. Conclusion: The leakage dose of low energy X-rays from 38 Crookes tube was explored using RPL dosimeters. It was estimated that the Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes at the distance of 1 m, while some equipment radiated a higher dose. With this study, the provisional guideline for the safety operation of Crookes tube is established.

핵의학검사의 방사성의약품 소아투여량 공식 별 투여량 및 유효선량 비교 (Comparing of the Administered Activities and the Effective Dose of the Various Pediatric Dose Formulas of Nuclear Medicine)

  • 길종원
    • 한국융합학회논문지
    • /
    • 제8권8호
    • /
    • pp.147-154
    • /
    • 2017
  • 본 연구는 소아핵의학검사에 사용하는 다양한 소아투여량 공식의 투여량(MBq)과 유효선량(mSv)을 산출 비교하여 적정투여량의 기준을 위한 기초자료를 제공하고자 한다. 연구는 2가지 방사성의약품($^{99m}Tc$-MDP와 $^{99m}Tc$-Pertechnetate)의 성인투여량을 기준으로 5가지 소아투여량공식(Clark법, Area법, Webster법, Young법, Solomon(Fried)법) 간 투여량과 유효선량을 비교하였다. 소아투여량 산출에 기준이 되는 성인투여량은 정준기, 이명철 '핵의학'에 수록된 값을 사용하였으며, 유효선량 산출을 위한 방사성의약품의 방사능당 유효선량(mSv/MBq)은 ICRP 80과 UNSCEAR 2008 보고서에 수록된 값을 사용하였다. 연구결과 Young법이 산출량이 가장 적으며 다른 공식과의 차이는 최소 1.7배-최대 3.4배였다. $^{99m}Tc$-MDP의 공식 간 투여량 차이는 최대 309.9MBq, 유효선량은 3.76mSv, $^{99m}Tc$-Pertechnetate는 최대 154.9MBq, 유효선량은 5.50mSv였다. 소아투여량 공식 간 투여량뿐만 아니라 유효선량도 차이가 크기 때문에 의료방사선의 최적화를 위한 적정투여량 소아산출법이 개발되어야 한다.

SiPM을 통한 휴대용 검출기의 최적 선량 제어에 대한 구현 및 평가 (Implementation and Evaluation of Optimal Dose Control for Portable Detectors with SiPM)

  • 강병욱;유선국
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1139-1147
    • /
    • 2023
  • 본 논문에서는 소형 크기인 SiPM Sensor를 휴대용 검출기 내부에 적용하여 환자 피폭을 최소화하면서도 최적의 이미지 획득을 위한 선량을 제어하기 위한 방법을 제시하고 이에 대한 성능을 평가하는 것을 목적으로 한다. 휴대용 검출기는 환자의 위치에 빠르게 접근하여 신속한 진단을 가능하게 하는 장점이 있지만 이러한 이동성은 선량 관리의 어려움을 동반한다. X-ray imaging devices 국제 표준인 IEC62220-1-1 기준의 이미지 평가를 통해 검출기의 DQE와 최적 화질을 갖을 수 있는 선량을 확인하고 영상의 ADU와 SiPM Sensor의 출력을 매칭 하여 최적 선량을 확인하는 방법을 제시하였다. 검출기 제조사 기준 선량과 최적 선량 구현으로 획득된 Skull AP 이미지는 제조사 기준 342.8 µGy, 최적 제어 선량은 148.3 µGy로 조사되어 제조사 기준 선량 대비 57 %, Chest AP는 제조사 기준 81.9 µGy, 제어된 최적 선량은 27.9 µGy로 66 %의 높은 선량 감소 효과가 확인되었다. 또한 촬영된 두 영상은 방사선사 5명의 분석을 통해 해부학적 구조물을 판별하기에 임상적으로 유의미한 차이가 없는 것으로 확인되었다.