• 제목/요약/키워드: Output dose

검색결과 289건 처리시간 0.027초

Using Nanosecond Electron Beam to Produce Silver Nanopowder

  • Balezin, M.E.;Timoshenkova, O.R.;Sokovnin, S.Yu.;Lee, Hi-Min;Rhee, C.K.
    • 한국분말재료학회지
    • /
    • 제15권6호
    • /
    • pp.466-470
    • /
    • 2008
  • Experiments with a URT-0.5 accelerator (0.5 MeV, 50 ns, 1 kW) generating a nanosecond electron beam for irradiation of silver nitrate in various liquid solutions (water and toluene) were performed with the aim of producing silver nanopowders. A radiochemical reaction allows making weakly agglomerated pure Ag powders with particles of 10-15 nm and 30-50 nm in size by irradiation in toluene and water respectively. The injection of the nanosecond electron beam energy to the solution is optimal. As the absorbed dose increases, the output of the radiochemical reaction does not grow, but more agglomerated powders are synthesized.

두릅나무 근피 추출물의 약물학적 연구 -흰쥐의 위염 및 웨궤양에 대한 효과- (Pharmacological Studies on Root Bark Extract of Aralia elata - Antigastritic and Antiulcerative Effects in Rats -)

  • 이은방;정춘식
    • 약학회지
    • /
    • 제37권6호
    • /
    • pp.581-590
    • /
    • 1993
  • In a preliminary screening of the plant extracts for the antigastritic action in rats, the extract of Aralia elata(Araliaceae) showed positive activity in HCI plus ethanol induced gastric lesion. Systematic fractions with hexane, chloroform, ethyl acetate and butanol resulted in the most patent activity with the butanol fraction: This butanol fraction at the oral dose of 200 mg/kg exhibited significant inhibition of absolute alcohol induced gastric lesion which was more potent than 100 mg/kg of cimetidine and had significant stimulation of mucus secretion. The butanol fraction showed significant decreases in the ulcer indices of Shay ulcers and inhibition of gastric juice secretion with acid output in pylorus-ligated stomachs of rats. It also suppressed the acetic acid induced gastric ulcer. These results might suggest that the butanol fraction had inhibitory action in gastric lesion and ulceration through inhibition of gastric acid secretion and stimulation of mucin secretion in the stomachs of rats.

  • PDF

X선영상증배관의 상대변환계수 측정에 관한 검토 (The Study on Measurement of Relative Conversion Factor in X-ray Image Intensifier)

  • 김성철;신성일;이선숙;허준;김성수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.28-33
    • /
    • 1997
  • For the Evaluation of X-ray image intensifier, we measured radiation dose at input of I. I., brightness and fluorescence at output of I. I. by using X-ray exposure meter, optometer and fluorescence meter for the relative conversion factor. Especially, by using fluorescence meter, we could easily get relative conversion factor without having regulated machine by JIS. Since using, the quality of image intensifier is going down. Consequently, it needs continuous quality maintenance.

  • PDF

Clonidine Patch에 피부자극성 시험 (Skin Irritation Test of Clonidine Patch)

  • 이영순;박우일;고광호
    • Biomolecules & Therapeutics
    • /
    • 제4권2호
    • /
    • pp.202-204
    • /
    • 1996
  • Clonidine, an antihypertensive drug, stimulates postsynaptic $\alpha_2$adrenergic receptors in the CNS and lowers arterial pressure by erects on both cardiac output and peripheral resistance. However, many patients experience that sedation and xerostomia occured upon oral administration of clonidine. These side effects are due to high plasma peak concentration and can be avoided when clonidine is given transdermally. In this study, we performed the skin irritation test for transdermal administration of clonidine patch on New Zealand white rabbits. Twelve New Zealand white rabbits were divided into two groups according to the dose levels, respectively. After transdermal administration of clonidine patch with two doses, clinical manifestations, body weight loss and postmortem findings were observed. We could not find any significant evidence of skin irritation by transdermal administration of clonidine patch.

  • PDF

방사성핵종을 이용한 치료에서 흡수선량의 평가 (Internal Radiation Dosimetry in Radionuclide Therapy)

  • 김경민;임상무
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제40권2호
    • /
    • pp.120-126
    • /
    • 2006
  • Radionuclide therapy has been continued for treatment of incurable diseases for past decades. Relevant evaluation of absorbed dose in radionuclide therapy is important to predict treatment output and essential for making treatment planning to prevent unexpected radiation toxicity. Many scientists in the field related with nuclear medicine have made effort to evolve concept and technique for internal radiation dosimetry in this review, basic concept of internal radiation dosimetry is described and recent progress in method for dosimetry is introduced.

Effective Low-Level Laser Therapy Including Laser Acupuncture Treatment Conditions for Non-Specific Chronic Low Back Pain: Systematic Review and Meta-Analysis

  • Yeum, Hyewon;Hong, Yejin;Nam, Dongwoo
    • Journal of Acupuncture Research
    • /
    • 제38권2호
    • /
    • pp.85-95
    • /
    • 2021
  • Low-level laser therapy including laser acupuncture has been widely used for non-specific chronic low back pain in primary Korean medical clinics. However, there is no critically appraised data regarding which treatment conditions are most effective. A systematic review and meta-analysis was conducted to determine effective treatment conditions using 12 databases (PubMed, Ovid, CENTRAL, KoreaMed, KMBASE, KISS, NDSL, KISTI, OASIS, CNKI, CiNII, and J-STAGE). There were 1,019 studies retrieved and 13 studies included in this review. It was determined that when the power output was ≥ 50 mW, the beam size was increased to ≥ cm2, the energy dose was increased to ≥ 4 J per point, the treatment interval was increased to ≥ 3 times a week, and the number of treatment sessions was increased to ≥ 10 treatments, these conditions appeared to increased treatment effectiveness.

Effect of Doxorubicin on Catecholamine Release in the Isolated Perfused Rat Adrenal Gland

  • Lim, Dong-Yoon;Oh, Song-Hoon;Seoh, Yoo-Seung;Lee, Eun-Sook;Kim, Il-Hwan;Jo, Seong-Ho;Hong, Soon-Pyo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제6권4호
    • /
    • pp.215-223
    • /
    • 2002
  • The present study was undertaken to investigate the effect of doxorubicin (DX) on secretion of catecholamines (CA) evoked by ACh, high $K^+,$ DMPP and McN-A-343 from the isolated perfused rat adrenal gland and to establish the mechanism of its action. DX $(10^{-7}{\sim}10^{-6}\;M)$ perfused into an adrenal vein for 60 min produced relatively dose- and time-dependent inhibition of CA secretory responses evoked by ACh $(5.32{\times}10^{-3}\;M),$ DMPP $(10^{-4}\;M)$ and McN-A-343 $(10^{-4}\;M).$ However, lower dose of DX did not affect CA secretion by high $K^+\;(5.6{\times}10^{-2}\;M),$ but its higher doses depressed time-dependently CA secretion evoked by high $K^+.$ DX itself did also fail to affect basal CA output. In adrenal glands loaded with DX $(3{\times}10^{-7}\;M),$ CA secretory responses evoked by Bay-K-8644, an activator of L-type $Ca^{2+}$ channels and cyclopiazonic acid, an inhibitor of cytoplasmic $Ca^{2+}-ATPase$ were time-dependently inhibited. Furthermore, daunorubicin $(3{\times}10^{-7}\;M),$ given into the adrenal gland for 60 min, attenuated CA secretory responses evoked by ACh, high $K^+,$ DMPP and McN-A-343. Taken together, these results suggest that DX causes relatively dose- and time-dependent inhibition of CA secretory responses evoked by stimulation of cholinergic (both nicotinic and muscarinic) receptors from the isolated perfused rat adrenal gland. However, lower dose of DX did not affect CA secretion by high $K^+,$ and higher doses of DX reduced time-dependently CA secretion of high $K^+.$ It is thought that these effects of DX may be mediated by inhibiting both influx of extracellular calcium into the rat adrenomedullary chromaffin cells and intracelluar calcium release from the cytoplasmic store. Also, there was no difference in the mode of action between DX and daunorubicin in rat adrenomedullary CA secretion.

6-MV선형가속기를 이용한 입체방사선수술의 선량측정 및 3차원적 치료계획 (Dosimetry and Three Dimensional Planning for Stereotactic Radiosurgery with SIEMENS 6-MV LINAC)

  • 최동락;조병철;서태석;정수미;최일봉;신경섭
    • Radiation Oncology Journal
    • /
    • 제11권1호
    • /
    • pp.175-181
    • /
    • 1993
  • 방사선수술을 시행하기 위해서는 종양의 위치결정, 흡수선량 계산, 그리고 치료를 위한 특수제작된 기구와 컴퓨터 프로그램이 요구된다. 본 연구의 목적은 선형가속기의 전반적인 기계적 정밀도를 확인하고 선형가속기를 이용한 방사선수술에 있어서의 선량계산 알고리즘을 개발하는 것이다. 치료기계의 정렬과 전반적인 치료체계의 성과에 대한 점검을 행하였고 백분율 심부선량, 중심축외 선량비, 그리고 출력인자와 같은 기본 계산자료를 측정하였다. 또한, 입체방사선수술을 위한 3차원적 치료계획 체계를 개발하였다. 선량분포를 계산하기 위하여 C-언어를 이용한 컴퓨터 프로그램을 작성하였고 하드웨어로는 IBM PS/2 (Intel 80386 SX, 24 MHz)를 사용하였다. 그 결과, 주 병원이 보유한 선형가속기의 겐트리와 테이블 회전에 따른 중심점에 대한 오차는 2 mm 이내로 방사선수술을 시행하기에 충분하였다. 팬톰실험에 따르면, 컴퓨터 단층촬영을 이용한 위치결정을 포함한 표적에의 빔의 일치도는 역시 2mm 이내였다. 끝으로, 본원에서 개발한 3차원적 치료계획의 정확도는 필름을 이용한 선량측정을 통하여 입증되었다.

  • PDF

고에너지 광자선을 이용한 방사선 치료 시 소조사면에서의 흡수선량평가에 관한 연구 (Study on the Small Fields Dosimetry for High Energy Photon-based Radiation Therapy)

  • 정해선;한영이;금오연;김찬형
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.290-297
    • /
    • 2009
  • 고에너지 광자선 기반의 소조사면을 이용한 방사선 치료 시, 조사면의 가장자리에서의 급격한 선량 변화, 전자의 비평형상태, 검출기의 체적 효과 및 검출기와 팬텀 물질과의 불균질성 등으로 인하여 정확한 선량 측정이 어렵다. 따라서 본 연구에서는 선량 측정을 위해 널리 사용되는 전리함, 다이오드 검출기 및 물과 등가인 재질로 이루어져 측정 시 오차 유발 요인이 적은 것으로 알려진 $GAFCHROMIC^{(R)}$ EBT 필름을 이용하여 팬텀 내 소조사면에서의 흡수선량을 측정하고, 각 검출기들의 특성 및 EBT 필름의 유용성을 평가하였다. 각 검출기는 팬텀 표면으로부터 10 cm 깊이에 장착, 선원과의 거리(SAD)를 100 cm로 하였으며, 6 MV X-선 빔을 6개 조사면($5{\times}5\;cm^2$, $2{\times}2\;cm^2$, $1.5{\times}1.5\;cm^2$, $1{\times}1\;cm^2$, $0.7{\times}0.7\;cm^2$$0.5{\times}0.5\;cm^2$)으로 팬텀에 조사하였다. $5{\times}5\;cm^2{\sim}1.5{\times}1.5\;cm^2$ 조사면의 경우, 모든 검출기들의 선량값이 1% 이내로 정확하게 일치하였으나, $1{\times}1\;cm^2$ 이하 조사면에서는 전리함을 이용한 측정결과가 타 검출기들에 비해 선량값을 매우 낮게 평가하는 것으로 확인되었다. 이는 검출기 체적효과가 매우 큰 오차요인으로 작용한 것으로 예측되어, 이를 제거하기 위해 제적 효과를 보정하는 컨볼루션 이론을 적용하여 측정된 선량값을 보정하였다. 그 결과, 다이오드 검출기의 경우 $1{\times}1\;cm^2$의 조사면에서는 EBT 필름의 흡수선량보다 약 3%가 높게, 전리함은 약 1% 낮게 측정되었다. $0.5{\times}0.5\;cm^2$ 조사면에서 다이오드 검출기는 약 1% 높은 값을, 전리함은 7% 낮은 선량값을 나타내었다. 결론적으로 $GAFCHROMIC^{(R)}$ EBT 필름의 소조사면 선량측정기로서의 유용성을 확인하였으며, 몬테카를로 전산모사를 이용한 추가 검증이 수행될 예정이다.

  • PDF

방사선 강내치료를 위한 소조사면 전자선cone의 선량분포 특성 (Fabrication and Dosimetry Characteristics of Intracavitary Cones for Radiotherapy)

  • 나수경;권수일
    • 한국의학물리학회지:의학물리
    • /
    • 제12권1호
    • /
    • pp.95-102
    • /
    • 2001
  • 방사선치료용 고 에너지 전자선의 조직내 선량분포는 매우 다양하게 나타나고 있으며 조직내에서 일정 깊이까지만 선량이 집중적으로 부여되고 그 이후에는 선량이 급감하는 특징으로 인하여 피부 및 피부에서 깊지않은 종양과 구강, 질강 등 강내조사에 존재하는 종양치료에 널리 이용되고 있다. 하지만 의료용 선형가속기에는 강내조사용 조사통(cone)이 제공되지 않고 있다. 본 실험은 2.5, 3.0, 3.5 cm ø 크기의 강내조사용 소조사면 조사통을 수직형과 30$^{\circ}$ 경사형으로 6가지를 직접 제작하여 에너지별, 조사통 크기별로 조직내 선량분포 특성을 실험하여 임상적 선량계획에 필요한 자료를 제공하는데 목적을 두고 실험하였다. 심부선량은 조사통 크기, 에너지 크기, 조사통 각도에 따라 다르게 나타나고 있으며 유효선량 깊이는 전자선 에너지 및 조사통이 커질수록 약간 증가하였고, X선 오염정도는 1.2% 이하로 나타났으며, 출력흡수선량율은 약 15-86 %로 나타났다. 고 에너지 전자선은 강내치료에 매우 유용하게 이용될 수 있으며, 조직내 선량분포 특성이 매우 다양한 양상을 나타내고 있음을 확인하였고 이러한 결과를 자료화하여 임상적 치료와 새로운 선량분포 모형 연구에 필요한 자료를 제공할 수 있으리라 생각한다.

  • PDF