• Title/Summary/Keyword: Outlet location

Search Result 116, Processing Time 0.023 seconds

Effects of Shopping Orientation on Brand Loyalty and Shopping Satisfaction of Fashion Outlet Consumers (패션 아울렛 소비자의 쇼핑성향이 브랜드 충성도 및 쇼핑만족도에 미치는 영향)

  • Lee, A-Ram;Yoo, Tai-Soon
    • Journal of the Korean Society of Costume
    • /
    • v.60 no.2
    • /
    • pp.114-129
    • /
    • 2010
  • The purpose of this study were to identify shopping orientation for fashion outlet consumers and its significance in influencing brand loyalty and shopping satisfaction. This study will propose results which help to better understand shopping orientation of fashion outlet consumers. A questionnaire was administered to 326 20s male and female living in Daegu Gyeongbuk during October of 2008. Data were analyzed by using Factor analysis, Reliability analysis, t-test and Regression analysis. The results of the research are as follows: First, The shopping orientation could be into 5 dimensions: pleasure tendency, fashion tendency, name brand tendency, prudence buying tendency, economic tendency. Brand loyalty were factor analyzed resulting three factors such as brand loyalty, brand care and brand knowledge. Brand loyalty factors of brand loyalty and brand knowledge had a positive effect on fashion tendency, name brand tendency. Brand care has a positive effect on name brand tendency and economic tendency. Second, Shopping satisfaction were factor analyzed resulting five factors such as product, store atmosphere, service store reputation, location convenience and price. Outlet product had a positive effect on fashion tendency, name brand tendency, prudence buying tendency and while all other factors showed a positive effect on preferences to follow trends. However, outlet price had a positive effect on only those consumers possessing a economic tendency.

On the Planning of Drainage Structures in Irrigation Channels. -Special Emphasis on the Drainage Inverted Siphon- (용수로상의 배수구조물계획에 대하여 -배수잠관을 중심으로-)

  • 김철기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.12 no.4
    • /
    • pp.2078-2083
    • /
    • 1970
  • The purpose of this study is to give the data neccesary for improving the planning of drainage structures, specially inverted siphons, in irrigation channels. With the samples of 15 drainage inlets, one drainage flume, 16 drainage inverted siphons and 6 drainage culverts in the 3 lines of irrigation channel under Chong-Won Irrigation Association, author abtained the following results. 1. It is presumed that design drainage discharge should be determined with some additional reserves, on the basis of the maximum rainfall intensity in local area and the size of drainage area on the topographical map, avoiding the way of eye measure. 2. Location of drainage inlet should be kept away from the place where topography can make lots of wash load, but when unavoidably allowing the inflow into irrigation channel, wash load outlet with even the purpose of drainage, or drainage flume in stead of drainage inlet should be taken account of. 3. It is presumed that drainage flume may be the structure which can perform its function from a structural point of view as far as topography permits. 4. Drainage inverted siphon should be avoided at any place as much as possible; a) In case that location of the siphon would be permitted only at paddy field, drainage area hauing the amount of discharge which requires more than 90cm in diameter could only be allowed. b) In this case, crest elevation of the tank of both inlet and outlet, at least, should not be lower than the surface level of paddy field. c) As far as topography and stratum permit, ratio of depth of outlet tank to head drop should be decreased as much as possible so that discharging efficiency of wash load could increase. d) In case of avoiding the setting of the siphon, irrigation aqueduct, irrigation inverted siphon, or drainage flume should be recommended in accordance with topography. 5. Discharging capability of wash load by drainage culvert appeared to depend hardly upon the diameter of the culvert, but greatly upon the location, specially near village, for there stones and dirts dumped may considerably be piled up. So, a counter plan for that is required.

  • PDF

GIUH Variation by Estimating Locations (단위도 산정지점에 따른 GIUH 형상 변화에 관한 연구)

  • Joo, Jin-Gul;Yang, Jae-Mo;Kim, Joong-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.85-91
    • /
    • 2011
  • RV-GIUH must be applied at an outlet or a junction of highest order stream of a subbasin because the model was derived for basins following Horton's ordering system. However hydrograph is calculated at various locations which does not fit to the desirable points. Therefore, some guideline is required for RV-GIUH application in practice. This study would like to suggest the outlet location criteria for appling RV-GIUH at un-gauged basin. Locations were selected by moving to upstream from outlet of Sanganmi basin and unit hydrograph using derived and simple RV-GIUH were estimated at each location. As the results, the peaks of RV-GIUH in upstream were exaggerated because of distortion of length ratio and total stream length. To avoid this error, the location must be selected at 60% downstream of highest stream length. To apply RV-GIUH at various places, equations correcting distortion of total stream length were suggested. With the correcting equations, it can be possible that RV-GIUH is applied at 20% downstream of highest stream length. Application and precision of RV-GIUH will be improved through this research.

A Study on Ventilation Effectiveness Characteristics in a Apartment Housing (공동주택에서 환기효율 특성에 관한 수치적 연구)

  • Cha, Kwang-Suk;Lee, Dae-Woo;Yeom, Dong-Suk;Park, Myung-Sig
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.39-44
    • /
    • 2005
  • Recently according to the fashion of well-being, it is increasing that heat recovery ventilator is applied to the apartment housing, But the uniform locations of inlet and outlet in each room may provide better indoor air quality than ununiform locations of inlet and outlet. Proper design of air supply system requires information concerning the gas concentration difference between the ventilation effectiveness at the breathing line. This paper presents models to predict the gas concentration difference and the ventilation effectiveness, based on the two cases with proper number of outlets. As one of the results it is desirable to set the outlet location near the furniture which produce the contamination gas so much.

  • PDF

Analysis of Space Cognition and Use Characteristics on Premium Outlet Shopping Mall -Focused on Exploratory Factor Analysis on Visitor's Behavior- (프리미엄 아웃렛 쇼핑몰의 공간지각 및 이용 특성분석 -방문자의 탐색적 요인분석을 중심으로-)

  • Park, Tae-Won;Lee, Deok-Jo;Park, Seung-Kyoo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.486-496
    • /
    • 2012
  • In recent years, the retail industry has been undergoing major shifts. Outlet malls are an important part of the new retail landscape. This paper seeks to increase the understanding of the shopping experiences of visitors to a Premium outlet shopping mall in Shinsagae Chelsea Premium Outlet at Paju City, Gyeongi-do. This paper analyze the Element of the premium outlet across demographics. It explores seven critical factors which significantly influence customers' perceptions of premium outlet. Findings are base on a mall intercept survey with 292 respondents across a range of demographics. The summary of 7 factor is classified as the visual, location, Shopping support, human traces, mood, transit expedience, and tenant. The main implication of these findings is that factory outlet stores are perceived favourably and that they need to build more positive marketing strategies accordingly.

A Study on the Smoke Movement by the Opening and Heat Generator Position (개구부와 열원의 위치에 따른 연기이동에 관한 연구)

  • 조성우;이재윤
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.7-14
    • /
    • 2002
  • The diffusion characteristics of the smoke by effect of an ascending air movement in a local part of the room where heat generated was studied. How the smoke move in the limited parts of the room at which heat generated was studied through 3 cases altering locations of inlet and outlet of ventilated air and heat generated by CFD(Computational Fluids Dynamics) method. It was found that 1. Similar distribution of air velocity, air temperature and smoke concentration appeared in the case of upper left inlet and lower right outlet and the case of lower inlet and upper right outlet. 2. Distribution of temperature and smoke concentration was 0∼0.3, 0.06∼0.14 in the case of lower left inlet and upper right outlet. 3. the location of heat generation did not influence on the temperature distribution, but influence on the distribution of smoke concentration.

Study on the Internal Flow of an Electric Oven with Variation of Steam Outlet Position (전기오븐의 스팀 출구위치에 따른 내부유동에 대한 연구)

  • Park, Young Hun;Kim, Yu Jin;Jung, Young Man;Park, Warn-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.450-456
    • /
    • 2013
  • The composite electric oven is one of the fixing utensil, various functions are required. Steam generating function, which is one of its functions, and allows various food cooking. The location of the outlet of the steam generator is designed around ease of installation, consideration of internal fluid is not. Distribution of the steam can not be non-uniformly. Accordingly, cooking time becomes longer, the energy consumption increases. As a result of the analysis, it was confirmed stagnation phenomenon of the internal flow through the interpretation of the calculations for the position of the outlet of the steam generator existing. Further, by computing the analysis of various locations of the outlet of the steam generator, we investigated the distribution and characteristics of the internal flow.

Experimental Investigation on the Efficiency of Reducing Air Bubble Formation by Installing Horizontal Porous Plate in the Submerged Outlet Structure of Power Plant (발전소 수중방류구조 내 수평유공판 설치에 따른 거품발생 저감효과에 관한 실험적 연구)

  • Oh, Sang-Ho;Oh, Young-Min;Kang, Keum-Seok;Kim, Ji-Young
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.5
    • /
    • pp.472-481
    • /
    • 2008
  • In this study hydraulic experiment was carried out to investigate the flow characteristics in the submerged outlet structure of Boryeong power plant and the efficiency of bubble reduction by installing horizontal porous plate in the outlet structure. The cross-sectional mean velocity in the submerged outlet structure was smaller than 1 m/s, the target value at the design stage to prevent bubble outflow to the open sea area. In addition, it was found that the maximum depth of bubble penetration is reduced 30 to 50% by installing the horizontal porous plate at the second falling location in the submerged outlet structure. It is expected that the total bubble amount entrained in the water will be most efficiently reduced by installing square-hole-shape porous plate of 20 cm hole size and making its central section as non-porous structure to dissipate the energy of falling water.

Optimum Design of an Automotive A/C Duct using by CFD (CFD를 이용한 승용차 에어컨 덕트의 최적설계)

  • Kim, T.H.;Jeong, S.J.
    • Journal of ILASS-Korea
    • /
    • v.1 no.3
    • /
    • pp.37-50
    • /
    • 1996
  • Computational fluid dynamics was used to optimize an A/C duct. Three dimensional flow analysis in an automotive A/C duct was performed computationally using various turbulence models and compared numerical predictions such as outlet flow split, surface pressure distribution along the duct to experimental data. Additionally, we studied the effect of location variation of 2nd branch on exit flow ratio and could find optimal location of 2nd branch. The design of an A/C duct was modeled and calculated to enhance the airflow distribution in each outlet using the STAR-CD computational fluid dynamics software. In results, modified $k-\varepsilon$ turbulence model allows a successful prediction of static pressure distribution particulary at around strong curvature but little improvement flow split. In the future, adoption of CFD to design an A/C duct with modified $k-\varepsilon$ model will bring benefits of producing more accurate prediction, and also give designers more detail information much more than now.

  • PDF

Dynamic Response of Hydraulic Transmission Lines with an Accumulator (축압기를 갖는 유압관로의 동특성에 관한 연구)

  • Lee, Ill-Yeong;Hong, Bong-Ki
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.29-34
    • /
    • 1981
  • More recently, unsteady flow in small-diameter pipes plays a major role in liquid propellantrocket systems, hydraulic and pneumatic control system, and elsewhere. And it has shown that line dynamics can have a marked effect on the hydraulic system characteristics. In this paper, transfer function of hydraulic lines with an accumulator and an outlet orifice is' developed and compared with experimental data from frequency response tests at various airvolume(V.) and the location of accumulator(ld1t), so that their performance may be correctly and easily predicted and the design of the systems incorporating them improved. The obtained results are as follows: 1. The dynamic response of hydraulic lines may be analyzed more accurately by use of the viscous term(22) in unsteady laminar flow. 2. There was good agreement between the theoretical and experimental results of this investigation, and hydraulic systems with liines included an accumulator can be analyzed more accurately by use of the pressure transfer function given by eq. (16). 3. For the mitigation of surge in hydraulic lines, it is more effective that the location ofaccumulator is close to the pipe outlet side. 4. According to the gas volume of accumulator is increased(the sealing pressure is close tomean line pressure), the damping effect of pressure wave is improved.

  • PDF