• Title/Summary/Keyword: Outlet location

Search Result 116, Processing Time 0.027 seconds

Optimum Design for Inlet and Outlet Locations of Rectangular Expansion Chamber for Improving Acoustic Performance (사각형 단순 확장소음기의 성능향상을 위한 입$\cdot$출구 위치의 최적설계)

  • 김봉준;정의봉;황상문
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.738-746
    • /
    • 1999
  • The performance of muffler can be improved for a frequency range of interest by moving inlet and outlet locations. And optimal location of inlet and outlet can be determined to improve the acoustic performance. The optimum design using FEM, however, may take a very long time and be very hard to take inlet and outlet locations as design variables. In this paper, the acoustic performance of reactive type single expansion chamber muffler is predicted using higher order mode theory. The sensitivity analysis of transmission loss with respect to the location of inlet and outlet is suggested. And the acoustic power transmission coefficient for a frequency of interest is used as cost function. Optimum location of inlet and outlet is determined to minimize cost function by using SUMT algorithm.

  • PDF

A Study on Pursuing Benefits and Satisfaction at Fashion Outlet Store (패션 아울렛 점포에 대한 추구혜택과 만족도 연구)

  • 박혜원;박주형;임숙자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.7
    • /
    • pp.950-961
    • /
    • 2004
  • This study was attempted to examine consumers' pursuing benefits and satisfaction at outlet store, to analyze the differences of pursuing benefits and satisfaction at outlet store among the consumer groups segmented by the pursuing benefits, and to provide useful information for establishment of marketing strategies. The subjects were 500 female consumers experienced in purchasing clothes at outlet non. For analysis of questionnaires, $\chi$$^2$-test, ANOVA, cluster analysis, factor analysis, and Duncan's multiple range test were performed. The results were as follows: 1. Pursuing benefits at outlet store were composed of 6 factors: store's atmosphere, variety of products and brands, service and reputation of store, product quality, location's convenience, and price. Consumers were segmented into three groups by above 6 factors: product pursuing group, store convenience pursuing group, and price pursuing group. 2. Satisfaction at outlet store was composed of 5 factors: product, atmosphere, service and reputation of store, location convenience, and price. Satisfaction at outlet store such as service and reputation of store, location's convenience, and price were significantly different among the segmented groups. Product pursuing group was most satisfied with service and reputation of store, store convenience pursuing group was most satisfied with location's convenience and price, and price pursuing group was most satisfied with price. 3. The demographic variables such as an age, marriage, occupation, academic background, and total income were significantly different among the segmented groups.

Optimum Design for Inlet and Outlet Locations of Circular Expansion Chamber for Improving Acoustic Performance (원형 단순 확장소음기의 성능향상을 위한 입.출구 위치의 최적설계)

  • An, Se-Jin;Kim, Bong-Jun;Jeong, Ui-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2487-2495
    • /
    • 2000
  • The acoustic characteristics of expansion chamber will be changed with the variation of inlet/outlet location due to the higher order acoustic mode in a high frequency in which the plane wave theory is not available. In this paper, the acoustic performance of reactive type expansion chamber with circular cross-section is analyzed by using the modified mode matching theory. The sensitivity analysis of four-pole parameters with respect to the location of inlet and outlet is also suggested to increase the acoustic performance. The acoustic power transmission coefficient is used as cost function, and the location of inlet and outlet is used as design variables. The steepest descent method and SUMT algorithm are used for optimization technique. Several results showed that the expansion chamber with optimally located inlet/outlet had better acoustic performance than concentric expansion chamber.

Chaff-outlet Grain Loss of Head-feed Combine -Changes in chaff-outlet gram loss on the variety, location of chaff-outlet loss control plate and traveling speed- (자탈형(自脱型) 콤바인의 배진손실(排塵損失)에 관(關)한 연구(硏究)(II) -품종(品種), 배진조절판(排塵調節板)의 위치, 작업속도(作業速度)가 배진손실량(排塵損失量)에 미치는 영향-)

  • Chung, C.J.;Choe, J.S.;Choi, Y.S.;Chung, S.I.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.4
    • /
    • pp.310-318
    • /
    • 1990
  • The amount of grain loss incurred during harvesting operation through the chaff-outlet of combine may not be negligible. To minimize this grain loss and optimize condition of combining, it may be necessary that the amout of chaff-outlet loss dependent on varying crop condition is to be estimated as exactly as possible. This study was thus intended to develop the monitor that could indicate the amount of grain lost through the chaff-outlet of combine during haravesting operation, and to find out driving and operating method of combine that could reduce chaff-outlet loss. In the study(1), the frequency distributions of each sound generated by the impact of kernels and chaff, the sound generated by the impact of the mixture of kernels and chaff, and vibration or noise created by the combine engine and other moving parts were investigated experimentally. Based on the results of frequency analyses, the loss monitor was developed which could measure the impact sound of paddy kernels that could be distinguished from those of other threshing products through chaff-outlet, and from vibration or noise created by the combine engine and other moving parts. Also in this study, detecting capability of monitor was tested by comparing the amount of grain lost through chaff-outlet with the amount of grain detected by the loss monitor, and changes in chaff-outlet grain loss on the increase of traveling speed, location of chaff-outlet loss control plate and variety of paddy rice were measured using the loss monitor. The monitor developed in this study efficiently measured the amount of grain lost through the chaff-outlet of combine. It was found that the chaff-outlet grain loss ratio was affected greatly by the variety of paddy rice, the location of chaff-outlet loss control plate and traveling speed of combine.

  • PDF

A Numerical Study of the 3-D Flow in the Primary Calcinator of Porcelain (도자기 1차 소성로의 3차원 유동장 수치해석에 관한 연구)

  • 김성수;홍성선;박지영;오창섭
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.50-55
    • /
    • 1996
  • A numerical simulation on a primary calcinator of porcelain was performed with using Fluent to calculate the heat efficiency by studying velocity vector and temperature profile according to variables such as the location of outlet and porcelain. Control-Volume based Finite Difference Method and Up-wind scheme are used for discretization of differential equation. SIMPLEC Algorithm and standard k-$\varepsilon$ turbulent model are selected to resolve the pressure-velocity coupling and the turbulent. The result of simulation showed that the whole velocity vector field in a calcinator was varied greatly according to the location of outlet. But the whole temperature profile at each zone was still high regardless of the location of outlet because of the radiation. But the temperature of a case with a outlet at sidepart of preheating or cooling zone was little high compared to the case with a outlet on the top of preheating zone. The velocity vector field and temperature profile in a calcinator were almost not affected by the location of porcelain, but the temperature inside a porcelain was much affected according to the place where it was located. The heat efficiency in a calcinator was 44.6% and the gas temperature in the outlet was about 1000 K.

  • PDF

Modified Mode Matching Technique for Analyzing Simple Expansion Chamber with Arbitrary Inlet/Outlet Location (임의의 입ㆍ출구 위치를 가지는 소음기 해석을 위한 개선된 모드일치법)

  • Kim, Bong-Jun;Jeong, Ui-Bong;Lee, Jeong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.5 s.176
    • /
    • pp.1314-1322
    • /
    • 2000
  • The acoustic property of reactive type single expansion chamber can be analyzed by traditional plane wave theory. This theory can be applied in low frequency range and has good performance. But this theory can't include higher order modes, therefore another method is essential to analyze acoustic filter in high frequency range. Many researcher suggested the method that can concern higher order modes, and their methods are using mode matching technique. But there is no method that can be applied to the analysis of single expansion chamber with arbitrary inlet/outlet duct position and numbers of higher order modes of inlet/outlet duct and middle chamber. In this paper, the method which can analyze single expansion chamber with arbitrary inlet/outlet duct position and numbers of higher order modes of inlet/outlet duct and middle chamber using fundamental mode matching technique, was suggested and the predictions by this method was compared with those by the finite element method, and the influence of inlet/outlet location to acoustic performance of single expansion chamber is investigated and explained by higher order mode effects.

Leakage Effect on the Exit Pressure in a Gas Pipeline (가스 파이프라인 내의 누출 현상이 출구 압력에 미치는 영향에 대한 연구)

  • Chang Seung-Yong
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.27-33
    • /
    • 2006
  • This paper investigates leak effect on the outlet pressure at pipeline exit. A modified Weymouth equation(including inclination effect) was used for this study. To investigate leak effect, outlet pressure and ratio of outlet to inlet pressure were compared between no leak and leak conditions for horizontal, upward and downward flows, respectively. Then, effects of leak location as well as leak rate on the outlet pressure were also investigated for all pipeline inclinations.

  • PDF

Acoustic Analysis of Circular Simple Expansion Chamber with Arbitrary Location and Cross-Section Area of Inlet/Outlet (원형단순확장관의 입$\cdot$출구 위치와 단면 크기를 고려한 음향해석법)

  • 김봉준;정의봉;황상문
    • Journal of KSNVE
    • /
    • v.9 no.5
    • /
    • pp.914-921
    • /
    • 1999
  • There are many theoretical investigations to analyze higher order mode of reactive type single expansion chambers with offset inlet/outlet locations. But the conventional method has the restriction that the ratio between the area of inlet(or outlet) pipe and that of chamber must be natural number. In the paper, a new method was suggested to apply the Kim's method to silencer with circular cross-section. Not only the offset location but also the magnitude of cross-section area of inlet/outlet pipe can be considered by the suggested method. The predictions by this new method also compared with those by the finite element method and Munjal's method in order to verify the accuracy of the suggested method presented here.

  • PDF

Characteristics of Uni-directional Diverter for Gravimetric Calibration Facility (액체용 중량식 유량계 교정장치의 일방향 Diverter 특성연구)

  • Nam, Ki Han;Park, Jong Ho;Kim, Hong Jip
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.59-64
    • /
    • 2017
  • Diverter is an essential element in gravimetric calibration method of flowmeter. Error of diverter are influenced by flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location. That's why, time detection position of diverter is tuned through repetitive test for minimizing error of diverter. Further the diverter must be compared with the other institutions test since the influence on the accuracy of the flow meter used in the test. In this paper, errors (flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location) of diverter are decreased by produced uni-direction diverter and error of gravimetric calibration system is decreased. Uni-direction diverter is calibrated by gravimetric calibration system with precision flowmeter, the flowmeter is calibrated by pipe prover and other institutions and uni-direction diverter is evaluated. Uni-direction diverter is not influenced by flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location. As a result, Uni-direction diverter can calibrate in wider scope since increasing ratio of maximum and minimum flow rate of uni-direction diverter.

Numerical Analysis of Flow Phenomena in Cylindrical Shell with Baffle according to the Position of Inlet and Outlet (출.입구 위치에 따른 배플을 갖는 원통내 유동특성에 대한 수치해석)

  • Shin, Y.H.;Sayeed, S.M.;Jean, Y.C.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.15 no.6
    • /
    • pp.22-26
    • /
    • 2011
  • A numerical simulation on the flow field was carried out on the cylindrical shell with baffles. The steady incompressible 3-D Navier-Stokes solution is obtained with the actual operational condition and geometry of the heat exchanger. The effect of the location of inlet and outlet on the cylindrical shell with baffle is investigated by varying flow rate. The angle between the location of In/Outlet and baffle cutting part is $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$, $120^{\circ}$, $150^{\circ}$ and $180^{\circ}$. The present results show that the pressure drop is dependent on Reynolds number in the inlet area and position of inlet and outlet; i.e., the pressure drop increases with increasing Reynolds number and the pressure drop decreases with increasing angle between baffle cutting part and position of inlet and outlet.