• Title/Summary/Keyword: Outlet Pressure

Search Result 844, Processing Time 0.027 seconds

Evaluation of removal performance of a novel two-stage cylinder type cyclone against water and oil droplets (2단 실린더형 싸이클론의 물 및 오일 액적 제거 성능 분석 연구)

  • Kim, Sumin;Kim, Hak-Joon;Kim, Myungjoon;Han, Bangwoo;Woo, Chang Gyu;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.3
    • /
    • pp.119-125
    • /
    • 2017
  • A novel two stage cylindrical cyclone was developed for a 3 phase separator in shale oil production industry. The cyclone performance was compared with a cone type cyclone and multi cyclone at the same experimental condition using water and oil mists generated by a humidifier and atomizer at the flow rate 1 to $2m^3/min$. The removal efficiency of total suspended water droplets by the novel cyclone, calculated using inlet and outlet concentrations measured by an optical particle counter, was 99% which is higher than 90% of oil droplet removal efficiency at $2m^3/min$. It might be due to the evaporation of small water droplets during the tests. The water and oil droplet removal performance of the novel cyclone based on the quality factor which is a function of pressure drop and removal efficiency was the highest among three cyclones. The results indicate that the cyclone could be an economical device to remove water and oil mists from shale gas generation processes where a huge three phase separator is commonly used.

A Numerical Method & Experiments for the Aerodynamic Design of High Performance 2-Stage Axial Flow Fans (고성능 2단 축류송풍기의 공력설계를 위한 수치해석 및 실험에 관한 연구)

  • Cho, Jinsoo;Han, Cheolhui;Cho, Leesang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.8
    • /
    • pp.1048-1062
    • /
    • 1999
  • A numerical method and experiments for the aerodynamic design of high performance two-stage axial flow fans was carried out. A vortex ring element method used for the aerodynamic analysis of the propellers was extended to the fan-duct system. Fan Performance and velocity profiles at the fan inlet and outlet are compared with experimental data for the validations of numerical method. Performance test was done based on KS B 6311(testing methods for turbo-fans and blowers). The velocity profile was obtained using a 5-hole pitot tube by the non-nulling method. The two stage axial flow fan configurations for the optimal operation conditions were set by using the experimental results for the single rotating axial flow fan and the single stage axial flow fan. The single rotating axial flow fan showed relatively low efficiency due to the swirl velocities behind rotor exit which produced pressure losses. In contrast, the single stage and the two-stage axial flow fans showed performance improvements due to the swirl velocity reduction by the stator. The peak efficiency of the two stage axial flow fan was improved by 21% and 6%, compared to the single rotating axial flow fan and the single stage axial flow fan, respectively.

Design and Analysis of a Radial Turbine for Ocean Thermal Energy Conversion (해양온도차발전용 반경류 터빈의 설계 및 해석)

  • Nguyen, Van Hap;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • The preliminary design of a radial inflow turbine using R134a as the working fluid at 5 kW of power for application to ocean thermal energy conversion (OTEC) is performed to obtain the trends for the efficiency and geometrical dimensions of the turbine. Using input conditions that included a turbine inlet temperature of $25^{\circ}C$, an outlet static pressure of 4.9 bar, and a mass flow rate of 1.16 kg/s, the results of a mean flow analysis show the major dimensions of the turbine, along with an angular velocity of 12,820 rpm. Based on these results, a three-dimensional turbine model is constructed for a computational fluid dynamics (CFD) analysis. The flow characteristics inside the turbine, including the volute and nozzle, are investigated using the CFD software ANSYS CFX. For a pertinent number of nozzle guide vanes, ranging from 10 to 15, the turbine efficiency was higher than 80%, with the highest efficiency shown by a nozzle with 15 guide vanes.

Manufacture of Control and Data Acquisition System of Centrifugal Thin Film Evaporator(Centri-Therm, CT-1B) by Computer (컴퓨터를 이용한 원심식 박막증발기의 제어 및 자료 수집 시스템의 제작)

  • Park, Noh-Hyun;Kim, Byeong-Sam;Park, Moo-Hyun;Han, Bong-Ho;Bae, Tae-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.479-485
    • /
    • 1990
  • For the automation of a evaporation process, computer based evaporation system was built and applied to acquisition of the process variables with an centrifugal thin film evaporator(Centri-Therm, CT-1B). Controls of the process conditions were performed by computer system for pressure, feeding rate, steam, evaporation temperature and flow rate of cooling water. The data acquisitions were also performed by computer system for the changes in the concentration and temperature readings for steam, evaporation and cooling water at the both inlet and outlet. The control and the acquisition variables were collected through the interface device and analyzed by programs using the PASCAL language. To control the feeding rate during the concentration process, inverter was used. The cooling water for the vapor condensation was controlled by the valve controller and should be supplied with the flow rate of 125 kg/h. The maximum vapor condensation rate was 41.7kg/h at the feeding rate of 125 kg/h.

  • PDF

Design of Multi-Phase Shift Controller for Valveless PZT Pump (밸브리스 압전펌프 연동구동 제어기 설계)

  • 조정대;박경민;노종호;함영복;유진산
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1282-1285
    • /
    • 2004
  • The high voltage driving system with multi-phase shifter including piezoelectric actuators comprised a driving power unit for outputting the driving power by converting input alternate current into direct current, a frequency shifting unit for supplying the direct current power and shifting or generating a frequency, a high-voltage amplification unit for amplifying the input signal outputted from the driving power unit and the frequency shifting unit into a high-voltage signal, and a phase shifting unit for shifting the phase difference of the amplified signal applied to the high-voltage amplification unit and driving plural piezoelectric actuators sequentially. The results that the operating voltage was stable, the voltage loss ratio was low and the response velocity was fast could be obtained. An experiment on performance of the high voltage driving system with multi-phase shifter designed and manufactured as above described was conducted by using a piezoelectric pump having 3 sheets of round unimorph piezoelectric actuators laminated respectively in a rectangular case. It sucks any fluid by causing the first piezoelectric actuator to shift from the inlet porter side, the phase delay of 60$^{\circ}$ causes the second piezoelectric actuator to begin to shift, and the phase delay of 120$^{\circ}$ causes the third piezoelectric actuator to begin to shift. As a result of measuring each change in the outlet flow rate of the piezoelectric pump, it was shown that the frequency-flow rate characteristic, the voltage-flow characteristic, and the load pressure-flow rate characteristic were improved.

  • PDF

Study on Characteristics of Fog in the Coastal Area of Mokpo (목포연안지역의 안개특성에 관한 연구)

  • Kim Do-Yong;Lee Sang-Deug;Kim Ji-Young;Woo Jong-Taek;Oh Jai-Ho
    • Journal of Environmental Science International
    • /
    • v.15 no.7
    • /
    • pp.623-634
    • /
    • 2006
  • In this study, characteristics of fog at Mokpo as the west coastal area of Jeonnam were investigated, using statistical analysis of observed fog and meteorological data. Higher frequency of the fog occurrence at Mokpo was showed in spring(32%) and summer(34%) due to the seasonal high atmospheric pressure. Regional characteristics as radiation cooling, advection of fog and water vapor from surrounding sea and Yeongsan lake, and frontal fog had major effect on the coastal fog at Mokpo on the meteorological conditions of north-west/south wind and calm($0{\sim}2m/s$). Also, as the results of analyzing data of before and after the construction of Yeongsan dam, the frequency of annual mean fog days increased 41 %, specially increased 178% in autumn. The increase of fog days mainly resulted from evaporation during colder seasons and from temperature inversion during warmer seasons over the water surface of Yeongsan lake. The construction of Yeongsan dam had a little effect on the meteorological conditions concerning fog occurrence, because Yeongsan dam which only supplies the water for use do not always carry out outlet of the cold water. In addition, the sea fog at Heuksando located in offshore had not effect on the occurrence of fog at Mokpo.

Numerical Study on the Sealing Safety of a Valve Packing in a LPG Cylinder (LPG 용기용 밸브패킹의 누설안전에 관한 수치적 연구)

  • Kim, Chung-Kyun;Kim, Tae-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.34-39
    • /
    • 2007
  • In this paper, the FEM result has been presented for a sealing safety between a valve packing and a valve seat during a open and close operation in a LPG cylinder. The sealing operation of a LPG valve is completed when the valve packing in which is made by a nylon-66 polymer is to stop a LP gas flow, which flows out from the outlet of a brass pipe in a LPG cylinder. The contact sealing mechanism of the valve may be classified by a flat contact of an unused valve packing and a circular groove contact of an used valve packing in a current LPG valve. Based on the FEM and experimental investigations the sealing force, 4.9 MPa for a flat contact mode of the unused valve packing is a little high compared to that of the used valve packing, which shows a circular groove contact geometry against a valve seat. But these sealing pressures for two contact modes are very low compared to the ultimate strenath 83 MPa of the nylon-66 and this may be designed with a excess strength of the valve.

  • PDF

Design and Evaluation of a High Concentration, High Penetration Unipolar Corona Ionizer for Electrostatic Discharge and Aerosol Charging

  • Intra, Panich;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1175-1181
    • /
    • 2013
  • The aim of this paper is to design and evaluate a high concentration, high penetration unipolar corona ionizer. The electrostatic characteristics in terms of voltage-current relationships of the present ionizer in the discharge zones for positive and negative coronas were discussed. Using ion current measurement, the concentration and penetration of ions were evaluated at corona voltages across the needle electrodes between 1 and 4 kV, flow rates between 1 and 5 L/min, and an operating pressure of 1 atm. In the discharge zone of the ionizer, the highest ion concentrations were found to be about $1.71{\times}10^{14}$ and $5.09{\times}10^{14}\;ions/m^3$ for positive and negative coronas, respectively. At the outlet of the ionizer, it was found that the highest ion concentration was about $1.95{\times}10^{13}$ and $1.91{\times}10^{13}\;ions/m^3$ for positive and negative coronas, respectively. The highest ion penetration for positive and negative coronas through the ionizer was found to be about 98 % and 33 %, respectively. The $N_it$ product for positive and negative coronas was also found to $1.28{\times}10^{13}$ and $7.43{\times}10^{13}\;ions/m^3s$, respectively. From the findings, this ionizer proved to be particularly useful as an aerosol charger for positive and negative charge before the detector in an electrical aerosol detector.

A Study on Performance of Solid Oxide Fuel Cell System for Ship Applications (선박 전원용 고체산화물형 연료전지(SOFC) 시스템 성능에 관한 연구)

  • Park, Sang-Kyun;Roh, Gill-Tae;Kim, Mann-Eung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.582-589
    • /
    • 2011
  • The fuel cell technology has been considered as a technology to reduce greenhouse gases emission from a ship. In this research, internal reforming 500kW solid oxide fuel cell system fueled by methane for a ship were developed. Characteristics of gas temperature, stack power and system efficiency depending on the air flow rate, $CH_4$ flow rate, $H_2O$ flow rate, and system operation pressure are evaluated. As a result, air and $CH_4$ flow rate directly affect the temperature of inlet and outlet gas in the fuel cell stack. When the air and $H_2O$ flow rate increase, the stack power and system efficiency increases. However, the case of $CH_4$ flow rate increase, the efficiency decreases.

A Study on Accalerated Vocous Condition in Siphon Spillway (싸이폰식 여수토의 진공촉진에 대한 연구)

  • 김시원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.6 no.2
    • /
    • pp.816-825
    • /
    • 1964
  • 1. Outline: The flow of the siphon spillway is very intricate and affected by vacuous condition. It is an intresting problem to make vacuum rapidly in_siphon, i.e, to provoke the perfect siphonaoge with the lowest water-level of overflow. The hydraulic experiments of siphon spillway have practiced at the Masan Lake, Haenam, the province of Junnam and gained rational and economical results which cannot be odtained by calculation. 2. Experiment: The model scale was a half of that of the prototype. 3. Results and discussion: In the experiments of 14 runs, washing, overflow water level, outlet, water level of cushion, phenomenon of water flying and water pressure of every part, etc. were studied. a) The relation of overflow water-level at siphon inlet and deflector When the elevation of the deflector is 10. 65m and the form of deflector O.4m long is the hypotenuse of an $45^{\circ}$ isosceles triangle, the over flow water-level is the minimum, i. e. the siphonage was excellent. There is no effect by the rising of overflow water-Ievel between 11.95m to 1O.65m of deflector elevation (in the first plan, it is 11.05m). But the overflow water-level rises remarkably in the outside region of the above limits. b) The relation of overflow water-level, the length of cushion and standard height of the base. The reduction of the length of cushion brings the rising of overflow waterlevel, and the rising of the standard height of the base brings the rising of overflow water level. For the long cushion length and low standard height of the base, it cannot be expeted to have the falling of overflow water-level. The most satisfactory data were obtained at 5.20m of the base standard height and 6.1m of the length of cushion. The first vah,le planned was 5.70 m and 4.30m.

  • PDF