• 제목/요약/키워드: Outlet

검색결과 2,623건 처리시간 0.03초

임의의 입ㆍ출구 위치를 가지는 소음기 해석을 위한 개선된 모드일치법 (Modified Mode Matching Technique for Analyzing Simple Expansion Chamber with Arbitrary Inlet/Outlet Location)

  • 김봉준;정의봉;이정환
    • 대한기계학회논문집A
    • /
    • 제24권5호
    • /
    • pp.1314-1322
    • /
    • 2000
  • The acoustic property of reactive type single expansion chamber can be analyzed by traditional plane wave theory. This theory can be applied in low frequency range and has good performance. But this theory can't include higher order modes, therefore another method is essential to analyze acoustic filter in high frequency range. Many researcher suggested the method that can concern higher order modes, and their methods are using mode matching technique. But there is no method that can be applied to the analysis of single expansion chamber with arbitrary inlet/outlet duct position and numbers of higher order modes of inlet/outlet duct and middle chamber. In this paper, the method which can analyze single expansion chamber with arbitrary inlet/outlet duct position and numbers of higher order modes of inlet/outlet duct and middle chamber using fundamental mode matching technique, was suggested and the predictions by this method was compared with those by the finite element method, and the influence of inlet/outlet location to acoustic performance of single expansion chamber is investigated and explained by higher order mode effects.

원형 단순 확장소음기의 성능향상을 위한 입.출구 위치의 최적설계 (Optimum Design for Inlet and Outlet Locations of Circular Expansion Chamber for Improving Acoustic Performance)

  • 안세진;김봉준;정의봉
    • 대한기계학회논문집A
    • /
    • 제24권10호
    • /
    • pp.2487-2495
    • /
    • 2000
  • The acoustic characteristics of expansion chamber will be changed with the variation of inlet/outlet location due to the higher order acoustic mode in a high frequency in which the plane wave theory is not available. In this paper, the acoustic performance of reactive type expansion chamber with circular cross-section is analyzed by using the modified mode matching theory. The sensitivity analysis of four-pole parameters with respect to the location of inlet and outlet is also suggested to increase the acoustic performance. The acoustic power transmission coefficient is used as cost function, and the location of inlet and outlet is used as design variables. The steepest descent method and SUMT algorithm are used for optimization technique. Several results showed that the expansion chamber with optimally located inlet/outlet had better acoustic performance than concentric expansion chamber.

The Efficacy of Scalene Injection in Thoracic Outlet Syndrome

  • Lee, Gun-Woo;Kwon, Young-Ho;Jeong, Ju-Ho;Kim, Jung-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권1호
    • /
    • pp.36-39
    • /
    • 2011
  • Objective : To evaluate the efficacy of scalene injection in patients with thoracic outlet syndrome. Methods : We selected 142 patients diagnosed with thoracic outlet syndrome between January 2005 and October 2009. We performed a series of scalene injection with conservative treatment in all cases. Patients rated their pain degrees using a visual analogue scale. We also evaluated the time to return to everyday life and work, and patients' functional capacity. Results : There were no complications or instances of inadvertent somatic or sympathetic ganglionic blockade after scalene injection. Overall, 111 patients (76.5%) experienced improved symptoms after the first set of scalene injection and 128 patients (88.2%) improved after scalene injection followed by conservative treatment. Of the 68 patients who returned to work during the study period, 54 returned within 1 week, and 62 within 2 weeks. Of those who returned to work, 61 reported nearly full functional capacity. We found that scalene injection was more effective in cases of thoracic outlet syndrome related to trauma than in those related to work-related repetitive stress. Conclusion : In patients with thoracic outlet syndrome, scalene injection effectively reduces pain. We recommend scalene injection as an adjunct to conservative treatment.

오수/합병정화조의 배출물 제어시스템 연구 (The control system of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank)

  • 박주식;김건호;오지영;임총규;강경식
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2001년도 추계학술대회
    • /
    • pp.193-202
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which ate the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxygen demanding amount has to control. Each mom must be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

능동형 케이싱 트리트먼트의 형상 변화가 원심압축기의 공력성능에 미치는 영향 (Geometrical Effects of an Active Casing Treatment on Aerodynamic Performance of a Centrifugal Compressor)

  • 마상범;김광용
    • 한국유체기계학회 논문집
    • /
    • 제19권4호
    • /
    • pp.5-12
    • /
    • 2016
  • In this study, a parametric study on a cavity as casing treatment of a centrifugal compressor has been conducted using three-dimensional Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model. Two kinds of cavity were applied at choke and surge conditions, respectively, in this work. Inlet and outlet port widths, angle of outlet port, and length of cavity were chosen as the geometric parameters and investigated to find their effects on the aerodynamic performances such as adiabatic efficiency at design mass flow rate and stall margin of the centrifugal compressor. It was found that the aerodynamic performances of the centrifugal compressor were affected considerably by the four geometric parameters. The adiabatic efficiency was hardly changed by the geometric parameters, excepts for the angle of outlet port. With an increase in the angle of outlet port, the adiabatic efficiency and the stall margin decreased. The stall margin was more sensitive to the outlet port width than to the other geometric parameters. And, with a decrease in the outlet port width, the stall margin increased by 2% compared to that of the reference.

퍼지제어를 통한 오수-합병정화조의 오니 측정 및 제어시스템에 관한 연구 (The Development using Fuzzy Control of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank)

  • 박주식;박윤규;강경식
    • 대한안전경영과학회지
    • /
    • 제3권4호
    • /
    • pp.53-63
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which are the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxyzen demanding amount has to control. Each room mus be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF

PIV와 LDV를 이용한 냉각수 토출구 주위의 와류 가시화 연구 (Visualization of Vortex Flow around Coolant Outlets Using PIV and LDV)

  • 홍지우;신수용;안병권
    • 한국가시화정보학회지
    • /
    • 제19권3호
    • /
    • pp.136-142
    • /
    • 2021
  • Submerged and semi-submerged vehicles expel cooling water through an outlet. In this process, induced noise and vibration by the flow around the outlet have been reported, and it may cause problems directly related to survivability of the navy vessels. The coolant outlet has a net-type structure and circular columns are mostly used. In this study, flow measurements using PIV and LDV were performed for different type outlets; conventional (flat plate with round bar) and improved (flat and flat plate) configurations. Experiments were conducted at a cavitation tunnel where pressure and steady flow rate conditions are ensured for sufficient time to measure the flow. The average velocity field of the outlets were measured and compared through LDV measurements, and instantaneous vorticities were evaluated through PIV measurements. The results show that the improved type of the outlet is advantageous in terms of flow stability compared to the conventional type of the outlet.

FCEV 충전 시스템 체크밸브의 수소 유입 극한 온도 조건에 따른 유동 성능 인자 분석 (Analysis of Flow Performance Factors According to Extreme Temperature Conditions of Hydrogen Inflow of FCEV Charging System Check Valve)

  • 오승훈;서현규
    • 한국수소및신에너지학회논문집
    • /
    • 제34권5호
    • /
    • pp.514-525
    • /
    • 2023
  • This study conducted numerical simulations with the purpose of analyzing the impact of variations in outlet pressure conditions under extreme temperature conditions on the fluid dynamics and performance of a check valve utilized in hydrogen refueling systems. Under the extreme temperature conditions, changes in outlet pressure conditions of the check valve were investigated to analyze velocity distributions, pressure distributions, and temperature distributions in the operational and connection regions. The analysis results indicated that changes in outlet pressure had a significant influence on the internal temperature variation of the check valve. Furthermore, due to density variations in the connection region caused by the cooling effect of excessively cooled hydrogen, a bias in the primary flow direction towards the lower part of the valve outlet was observed in the outlet area. Through a comparison of the results of the valve's inherent flow performance, represented by the flow coefficient, it was observed that when the pressure difference between the inlet and outlet was below 0.37 MPa, sufficient flow was not ensured.

아울렛 쇼핑센터의 이용의도에서 아이덴티티 현저성의 요인과 경제성의 역할 (The Roles of Economic Benefits and Identity Salience: Inducing Factors in the Behavioral Intent to Use Outlet Shopping Centers)

  • 최낙환;임아영;안려나
    • 유통과학연구
    • /
    • 제11권6호
    • /
    • pp.41-50
    • /
    • 2013
  • Purpose - Inducing consumers' behavioral intent to use an outlet shopping center is a critical issue for managers since it can be used as a guide for developing marketing strategies. Low prices could lead to a growth in retail purchases, but there might also be a positive relationship between prices and customer perceptions of product quality. The extent to which consumers use price as a predictor of quality may differ according to the availability of important alternative cues such as brand, store name, and identity salience triggered by the store. Consumers can obtain non-economic benefits from marketing exchanges that go beyond basic economic achievement. We argue that identity salience can play a crucial mediating role when consumers, acting as exchange partners, seek to obtain social benefits. This study shows that identity salience could mediate the relationship between identity salience-inducing factors such as multi-finality, prestige and role performance, and consumers' behavioral intent to use an outlet shopping center. Research design, data and methodology - The survey was conducted on college students enrolled in marketing classes. A total of 200 questionnaires were distributed, of which only 194 were returned. After five incomplete questionnaires were excluded, a final sample of 189 was used for empirical analysis. Using a covariance structural analysis in Amos17, we confirmed the fit of the research model and estimated its parameters by using the maximum likelihood method. Results - The results of the hypotheses testing are as follows. First, both identity salience and economic benefits have positive effects on the behavioral intent to use an outlet shopping center. Second, role performance, prestige, and multi-finality have positive effects on identity salience. Finally, the additive analysis of the direct effects of identity salience-inducing factors shows that the role performance, prestige, and multi-finality factors have no direct effects on the behavioral intent to use an outlet shopping center, suggesting that identity salience plays a positive mediating role. Conclusions - This study informs marketers that not only price but shoppers' identity salience directly affects their intent to visit an outlet shopping center. To strengthen shoppers' identity salience, marketers should find ways to help shoppers fulfill their multiple social roles, realize their multiple goals, and achieve prestige. In other words, outlet shopping centers must improve their personal service environment in order to enhance their employees' service quality and assist the execution of multi-finality by minimizing the perceived costs (e.g., travel time, effort) associated with shopping trips, thus making it easier for consumers to combine visits to multiple stores in outlet shopping centers and buy the items required for their consumption goals. Outlet shopping centers must also offer assortments with both breadth and depth in order to help consumers play the social roles their social networks have given them.

흉곽 출구 증후군의 치료 (The Treatment of Thoracic Outlet Syndrome)

  • 이윤민;송석환;최기범;이승구
    • Archives of Reconstructive Microsurgery
    • /
    • 제20권2호
    • /
    • pp.102-107
    • /
    • 2011
  • Purpose: As clinical manifestations of thoracic outlet syndrome are vague pain or symptoms in upper extremity, the diagnosis of the disease is delayed or misdiagnosed as cervical HNP, shoulder pathologies, or peripheral neuropathies. In that reason, many patients spend time for unnecessary or ineffective treatments. We report the results of our thoracic outlet syndrome cases, which were treated by conservative care or surgical treatment. Materials & Methods: Twenty five cases, diagnosed as thoracic outlet syndrome since 1999, were reviewed retrospectively. Physical examinations including Adson's and reverse Adson's test, hyperabduction test, costoclavicular maneuver, and Roo's test, plain radiography of shoulder and cervical spine, MRI of neck or brachial plexus, and EMG were checked. If subjective symptoms were not improved after conservative treatments over three months, surgical treatment were performed. Nine patients were performed operative treatment and the others had conservative treatment in outpatient clinic. Postoperative improvement of symptoms and the follow up period, and the results of conservative care were reviewed. Results: Among five physical examinations, mean 1.75 tests were positive, and EMG has little diagnostic value. MRI were performed in twenty cases and compression of brachial plexus were found in 6 cases (30%). Ten patients out of 16 conservative treatment group had excellent improvement of symptoms, and 5 had good results. Eight patients out of 9 operative treatment group had excellent improvement with mean 5.1 months of follow-up period. Conclusion: Diagnosis of thoracic outlet syndrome is difficult due to bizarre and vague symptoms. However if the diagnosis is suspected by careful physical examinations, radiologic studies, or nerve conduction studies, conservative care should be done as initial treatment and at least after three months, reassess the patient's condition. If the results of conservative treatment is not satisfactory and still the thoracic outlet syndrome is suspected, surgical treatment should be considered. Conservative treatment and operative technique are the valuable for the treatment of this disease.

  • PDF