• 제목/요약/키워드: Outlet

검색결과 2,623건 처리시간 0.024초

극저습 공조실의 환기성능에 대한 수치적 모사 (Numerical Simulation of Ventilation Performance in a Dry Room)

  • 최석호;이관수
    • 대한기계학회논문집B
    • /
    • 제26권4호
    • /
    • pp.594-603
    • /
    • 2002
  • The characteristics of moisture ventilation in a dry room were studied numerically The effect of three important parameters: position of outlets, aspect ratio($\beta$) of horizontal plane and air exchange rate(N), was analyzed by using the scales of ventilation efficiency. The ventilation performance was evaluated by varying the aspect ratio and air exchange rate in the four types of outlet position. It was shown that the ventilation performance was improved by decreasing the aspect ratio in the longitudinal arrangement of outlet. The highest ventilation performance was determined when $\beta$ was 4 in the transverse arrangement of outlet. Regardless of the aspect ratio, the ceiling arrangement of outlet played more dominant effect on the ventilation efficiency than the floor arrangement. In every type and aspect ratio, the increase of air exchange rate to improve ventilation performance was appropriate up to N=60 /h.

소형엔진 기화기 내의 흡기 맥동 특성 (Characteristics of Pressure wave Pulsation at Carburetor on Small SI Engine)

  • 오진우;최영하;김병국;이동근;김동선;윤석주
    • 한국분무공학회지
    • /
    • 제14권1호
    • /
    • pp.34-38
    • /
    • 2009
  • This paper presents the pulsation of carburetor inlet and outlet pressure of a small SI gasoline engine. The engine used in this paper is a 23cc, single cylinder, diaphragm carburetor, two-stroke, air-cooled for brush cutter. The rpm and pressure wave pulsation at the inlet and the outlet of carburetor were measured and analysed for the understand of the internal air flow into the barrel on the diaphragm carburetor. These data should be used for the development of the duel fuel injection system for gasoline and LPG. The results showed that the carburetor inlet pressure variations were very steady, but the pressure variations at carburetor outlet were very sensitive to the pressure variation into the crank case and were to similar independently to the engine speed on partial opened throttle conditions. According to increasing engine speed, the pressure waves started to come out and be developed after closing the intake port of the engine at carburetor outlet. Reverse flow occurred on the WOT (wide open throttle) condition.

  • PDF

진통소염제에 의한 위 십이지장 궤양에 합병된 위 출구 폐쇄 1예 (A Case of Gastric Outlet Obstruction Complicated by Peptic Ulcer Secondary to Non-Steroidal Anti-Inflammatory Drug (NSAID))

  • 최창환;변성환;장수희;백소야
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제8권2호
    • /
    • pp.226-232
    • /
    • 2005
  • 저자들은 11개월 영아의 고열을 조절하기 위해 진통소염제 근주와 경구 해열제 병용투여 후 발생한 다발성 식도 위 십이지장 궤양 치료 과정 중 조기에 위 출구 폐쇄가 합병된 1예를 경험하였기에 보고하는 바이다.

  • PDF

평행류 열교환기 내부의 열유동 해석 (Heat and Flow Analysis Inside a Parallel-Flow Heat Exchanger)

  • 오석진;정길완;이관수
    • 대한기계학회논문집B
    • /
    • 제27권6호
    • /
    • pp.781-788
    • /
    • 2003
  • In the present study, the heat and flow characteristics of a parallel-flow heat exchanger are numerically analyzed by using three-dimensional turbulent modeling. Heat transfer rate and pressure drop are evaluated using the concept of the efficiency index by varying the locations, the shapes and angles of inlet/outlet, and the protrusion height of flat tube. It is found that negative angle of the inlet improves the heat transfer rate and pressure drop. Results show that the locations of the inlet and outlet should be toward the right side and the left side to the reference model, respectively, in order to enhance the heat transfer rate and pressure drop. Increasing the height of the lower header causes pressure drop to decrease and yields the good flow characteristics. The lower protrusion height of flat tube shows the improvement of the heat transfer rate and pressure drop. The heat transfer rate is greatly affected by the parameters of outlet side such as the location and angle of the outlet. However, the pressure drop is influenced by the parameters of inlet side such as the location and angle of inlet and the height of the header.

주화성에 의한 활동성 정자 분리용 마이크로 바이오칩에 관한 연구 (A Study About Microbiochip for Separation of Motile Sperm by Using Chemotaxis)

  • 고용준;맹준호;안유민;황승용
    • 대한기계학회논문집A
    • /
    • 제32권12호
    • /
    • pp.1115-1122
    • /
    • 2008
  • This paper presents a new microchip which can separate motile sperm by chemotaxis. The microchip was developed to create longitudinal concentration gradient in the microchannel due to diffusion. Linearly good concentration gradient of chemoattractant was generated without any fluid control devices. In sperm separation experiment with the developed microchip, mouse sperm was used as sample and acetylcholine was selected as chemoattractant. Human tubal fluid (HTF), buffer solution, was introduced into the microchannel of the microchip and attractants diluted in ratio of 1, 1/2, 1/4, 1/8, 1/16, 1/32 and 1/64 including control (DI water) were dropped in each outlet by $2\;{\mu}l$ volume with micropippet. After 5min, $1\;{\mu}l$ sperm solution was dropped into inlet of the chip. After 10 min, when sperms reached to the outlet by chemotaxis, we counted sperms in each outlet by using microscopy. Consequently, we could separate progressive motile sperm with the new microchip. In the experiment, the most sperms were isolated at the outlet dropped with 1/16 diluted solution. The optimal concentration gradient to induce chemotaxis was about 0.625 mg/ml/mm.

상설할인매장애고자의 구매행동 (Purchasing Behavior of Outlet Store Patronage Consumers)

  • 구양숙
    • 복식
    • /
    • 제33권
    • /
    • pp.201-215
    • /
    • 1997
  • The purpose of this study was to investigate the actual state and problems of outlet stores. And examine store attributes shopping orientations information sources according to demographic characteristics for outlet store patronage group. The questionnaires were administered to 400 women living in Taegu. The data were analyzed by using Frequency Percentage Factor Analysis MANOVA. The results of the study were as follows; 1) Outlet stores in Taegu area were run as the type of agency and dealt in most brands of their own companies, There were plenty of as-sortment and merchandise. The discount rate was 50-60% Stores' locations were scattered which made shopping environment incon-venient. 2) The store attributes were composed of five factors such as fashion & products diver-sity service store reputation convenience and price. Shopping orientation were com-posed of six factors such as self-confidence for shopping brand oriented store loyalty & near-store oriented economical self-assumed shopping and difficulty of choice. Information sources were composed of four factors such as print media & display personal information advertising and store visit. 3) There were significant differences be-tween patronage group and non-patronage group in store reputation service fashion & products diversity. Patronage group is more satisfied with these three factors. There were significant differences between patronage group and non-patronage group in brand oriented and economical Non-patronage group was more brand oriented and patronage group was more economical. There were significant difference between patronage group and non-patronage group in print dedia & display factos. Non-patronage group made more use of print media& display than patronage group as information sources. There were significant differences between patronage group non-patrpnage group in age marital status and levle of education.

  • PDF

Fluidic 유량계의 기하학적 변수가 유동률에 미치는 영향 (Effects of geometric parameters of fluidic flow meter on flow rate)

  • 박경암;윤기영;유성연
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1608-1614
    • /
    • 1997
  • The fluidic flow meter detects the gas flow rate based on the principle of fluidic oscillation instead of the conventional displacement method. It has many merits: wide rangeability, no moving mechanical parts and calibration insensitive to physical properties of fluids. The width of nozzle, size of oscillation chamber, size of target, width of outlet are tested to obtain the effects of jet oscillation on the fluidic flow meter. As the width of nozzle is too wide compared with the size of target, jet oscillation is unstable. The oscillation frequency decreases as the distance between the nozzle and target increases and also as the distance between target and outlet contraction increases. Two different vortexes exist in the front and the rear regions of the target, and they affect the oscillation frequency. The outlet contraction is very important, because the feedback flow is generated by the blocking of the flow. As the width of outlet increases, the jet oscillation frequency decreases. The linearity of this tested flow meter is quite good.

개구부와 열원의 위치에 따른 연기이동에 관한 연구 (A Study on the Smoke Movement by the Opening and Heat Generator Position)

  • 조성우;이재윤
    • 한국화재소방학회논문지
    • /
    • 제16권4호
    • /
    • pp.7-14
    • /
    • 2002
  • 열원의 발열이 있는 작은 공간에서 상승기류에 의한 연기 확산의 특징에 대하여 조사하였다. 유입구와 유출구의 위치와 연기의 발생위치의 변화에 대한 3가지의 경우에 대하여 수치시뮬레이션을 이용하여 연기가 어떻게 확산되는가를 알아보았다. 좌측 상부에 유입구와 우측 하부에 유출구가 설치된 경우와 좌측 하부에 유입구, 우측 상부에 유출구가 설치된 경우는 기류속도, 공기온도 및 연기농도는 비슷한 분포를 나타냈다. 또한, 좌측 하부의 유입구와 우측 상부의 유출구인 경우 온도분포는 0∼0.3이고, 연기의 농도분포는 0.06∼0.14로 나타났다. 특히, 열원의 발열의 위치는 작은 실에 있어서 온도분포에는 영향을 미치지 않으나, 농도분포에는 영향을 미치는 것을 나타났다.

냉방과 난방 부하 감소를 위한 지하피트의 이용 가능성 (The Possibility on Utilization of Underground Pit for Reduction of Cooling and Heating Load)

  • 조성우
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.144-150
    • /
    • 2006
  • The purpose of this study is to predict outlet temperature and humidity through underground pit for the reduction of cooling load and heating load. Commonly, the underground temperature is lower than outdoor in summer but the reverse happens in winter. When the outdoor average air temperature is $25.7^{\circ}C$ during cooling periods, the average outlet air temperature through underground pit is $23.6^{\circ}C$ with 3 m-depth and 60m-length and is $22.2^{\circ}C$ with 3 m-depth and 150 m-length. When the outdoor average air temperature is $4.9^{\circ}C$ during heating periods, the average outlet air temperature through underground pit is $7.7^{\circ}C$ with 3m-depth and 60 m-length and is $10.8^{\circ}C$ with 3 m-depth and 150 m-length. The outlet air temperature is affected by more length than depth of underground pit. The diffusion ratio of outdoor humidity is $-7.7\times10^{-8}kg/s$ in cooling periods and $9.29\times10^{-7}kg/s$ in heating periods.

패션 유통업태간 소비자가 요구하는 판매원의 서비스 차원 비교(I) - 백화점, 할인점, 아울렛몰을 중심으로 - (Comparison of the Salesperson's Service on Fashion Retailing Formats - Focused on Department Store, Discount Store, and Outlet Store -)

  • 이진화;허아현
    • 한국의류산업학회지
    • /
    • 제10권3호
    • /
    • pp.289-297
    • /
    • 2008
  • This paper was to examine the salesperson's service that the consumer demands in different types of fashion retailing formats including department store, discount store and outlet store. Data has been collected from June to August in 2005 in Pusan and Seoul on subject of 1000 adult over18 years old and 979 pieces were used to analyze. Data analysis was conducted by factor analysis, regression using the SPSS statistics package program. Services in common in 3 fashion retailing formats were "individual concerning", "kindness, courtesy/customer respect", "quick correspondence/convenience", and "product knowledge". Unique services that consumer demanded for the department store were professional and polite attitude; for the discount store, honesty and convenience for refund and exchange; for the outlet store, wide range of product selection. The results has shown that the part of salesperson's service dimensions influenced the consumer's purchase, repurchasing intention and the level of satisfaction. Therefore fashion marketers need to carefully implicate operation and service management depending on the retailing formats.