• 제목/요약/키워드: Outflow rate

검색결과 275건 처리시간 0.026초

ERotating Bondi Accretion Flow with and without outflow

  • Han, Du-Hwan;Park, Myeong-Gu
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.52.4-53
    • /
    • 2020
  • It is less well known that the properties, especially the mass accretion rate, of accretion flow are affected by the angular momentum of accreting gas. Park (2009) found that the mass accretion rate \dot{m}, mass accretion rate in units of Bondi accretion rate, is inversely proportional to the angular momentum of gas λ, at the Bondi radius where gas sound speed is equal to the free-fall velocity and proportional to the viscosity parameter α, and also Narayan & Fabian (2011) found a similar relation, but the dependence of the mass accretion rate of the gas angular momentum is much weaker. In this work, we investigate the global solutions for the rotating Bondi flow, i.e., polytropic flow accreting via viscosity, for various accretion parameters and the dependence of the mass accretion rate on the physical characteristics of gas. We set the outer boundary at various radius r_{out}=10^3~10^5 r_{Sch}, where r_{Sch} is the Schwarzschild radius of the black hole. For a small Bondi radius, the mass accretion rate changes steeply, as the angular momentum changes, and for a large Bondi radius, the mass accretion rate changes gradually. When the accreting gas has a near or super Keplerian rotation, we confirm that the relation between the mass accretion rate and angular momentum is roughly independent of Bondi radius as shown in Park (2009). We find that \dot{m} is determined by the gas angular momentum at the Bondi radius in units of r_{Sch}c. We also investigate the solution for the rotating Bondi flow with the outflow. The outflow affects the determination of the mass accretion rate at the outer boundary. We find that the relation between the mass accretion and the gas angular momentum becomes shallower as the outflow strengthens.

  • PDF

용담댐 운영 시나리오에 따른 대청댐 저수량 변화에 관한 연구 (A Study on Daily Water Storage Simulation of the Daecheong Dam by Operation Scenario of the Yongdam Dam)

  • 노재경;김현호
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1403-1407
    • /
    • 2005
  • In order to analyze the water storage of the Daecheong dam after constructing the Yongdam dam situated in upstream, a daily cascaded simulation model for analyzing water storages in the Yongdam-Daecheong dams was developed. Operation scenarios of the Yongdam dam were selected to 8 cases with the combinations of downstream outflows and water supplies to the Jeonju region. Daily water storages in the Daecheong dam was analyzed daily by simulating from 1983 to 2004. The results are summarized as follows. Firstly, water supplies from the Daecheong dam were analyzed to amount $1,964.2Mm^3$ on a yearly average in case without the Yongdam dam. In case with the Yongdam dam, water supplies from the Daecheong dam were analyzed to amount $1,858.7\~1,927.3Mm^3$ in case with downstream outflow of $5\;m^3$ is, and were analyzed to amount $1,994.9\~2,017.8Mm^3$ in case with downstream outflow of $10\;m^3/s $. These values are compared to $1,649Mm^3$ applied in design. Secondly, reservoir use rate which was defined rate of water supply to effective water storage reached $241.3\% in case without the Yongdam dam. In case with the Yongdam dam, reservoir use rate reached $228.3\~236.8\% In case with downstream outflow of $5\;m^3/s$, and reached $245.1\~247.9\% in case with downstream outflow of $10\;m^3/s$. Thirdly, runoff rate which is defined rate of dam inflow to areal rainfall reached $57.3\% in case without the Yongdam dam. In case with the Yongdam dam, reservoir use rate reached $62.0\~68.4\% in case with downstream outflow of $5\;m^3/s$, and reached $64.1\~68.5\% in case with downstream outflow of $10\;m^3/s$. Fourth, in case with downstream outflow of $10\;m^3/s$ is from the Yongdam dam, appropriate water supply amounts to the Jeonju region were analyzed to only $0.50Mm^3/day$ from the daily simulation of water storages in the Yongdam dam. Comprehensively, water supply capacity of the Daecheong dam was analyzed to affect in small amounts in spite of the construction of the Yonsdam dam. It is effected to achieve the effective water management of the Yongdam dam and the Daecheong dam by using the developed cascaded model.

  • PDF

공연장 무대부 화재에 대한 전산해석 연구: 자연 배연구 면적과 화원 위치 영향 (Numerical Investigation on Fire of Stage in Theater: Effects of Natural Smoke Vent Area and Fire Source Location)

  • 박민영;이치영
    • 한국안전학회지
    • /
    • 제37권1호
    • /
    • pp.1-11
    • /
    • 2022
  • This numerical study investigates the effects of the size of the natural smoke vent area (10% and 1% of the floor area) and the location of the fire source (i.e., at the side and center of the stage) on the temperature distribution in the compartment and velocity distribution and mass flow rate of flow through a natural smoke vent for a reduced-scale model of a theater stage. Then, the mass flow rate of outflow through the natural smoke vent in the event of a fire for a real-scale theater stage was examined. The case with the larger natural smoke vent area and central fire source location showed lower temperature distributions and higher mass flow rates of outflow and inflow than the case with the smaller natural smoke vent area and side fire source location. The trends of the temperature distributions were closely related to those of the mass flow rates for the outflow and inflow. Additionally, the case with the larger natural smoke vent area and central fire source location exhibited the most non-uniform flow velocity distribution in all cases tested. A bidirectional flow, in which the outflow and inflow occur simultaneously, was observed through the natural smoke vent. In the event of a fire situation in a real-scale theater stage, it was predicted that the case with the larger natural smoke vent area and central fire source location would have a mass flow rate of outflow that is 43.53 times higher than that of the case with the smaller natural smoke vent area and side fire source location. The present results indicate that the natural smoke vent location should be determined by considering the location in a theater stage where a fire can occur.

도시홍수방재를 위한 수문모니터링시스템의 적용 (Application of Hydrological Monitoring System for Urban Flood Disaster Prevention)

  • 서규우;나현우;김남길
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1209-1213
    • /
    • 2005
  • It reflects well feature of slope that is characteristic of city river basin of Pusan local. Process various hydrological datas and basin details datas which is collected through basin basis data. weather satellite equipment(EMS-DEU) and automatic water level equipment(AWS-DEU) and use as basin input data of ILLUDAS model, SWMM model and HEC-HMS model In order to examine outflow feature of experiment basin and then use in reservoir design of experiment basin through calibration and verification about HEC-HMS model. Inserted design rainfall for 30 years that is design criteria of creek into HEC-HMS model and then calculated design floods according to change aspect of the impermeable rate. Capacity of reservoir was determined on the outflow mass curve. Designed imagination reservoir(volume $54,000m^3$) at last outlet upper stream of experiment basin, after designing reservoir. It could be confirmed that the peak flow was reduced resulting from examining outflow aspect. Designing reservoir must decrease outflow of urban areas.

  • PDF

도시고속도로 램프미터링을 위한 진입극대화방안과 진출극대화방안의 비교 연구 (A Comparative Analysis between Inflow rate Maximizing and Outflow rate Maximizing for the Urban Expressway Ramp Metering)

  • 이인원;김대호
    • 대한교통학회지
    • /
    • 제14권4호
    • /
    • pp.7-29
    • /
    • 1996
  • The optimal solution obtained by a linear programming model is to maximize the ramp inflow rate. It is argued in this paper that the maximization of inflow rate is different from the maximization of outflow rate under congested conditions. Therefore, this paper proposes a systematic searching procedure from a linear programing formulation to a integer programming : first obtain the optimal solution by a linear programming and then adding weight to linear programming then. solve the optimal solution again by integer programming i.e. The proposed method is an interactive approach. Measure of effectiveness by simulation models regards the real time data(O/D, queue, delay, etc), can be utilized in the proposed interactive process.

  • PDF

하천수정화 근자연형 인공습지의 초기 인 제거 (Preliminary Phosphorous Removal Rate in a Natural-type Constructed Wetland for Stream Water Treatment)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제5권6호
    • /
    • pp.30-36
    • /
    • 2002
  • A 0.19 hectare natural-type wetland for stream water treatment demonstration was constructed and planted with cattails from April 2001 to May 2001. Part of its bottom surfaces adjacent to levees have a variety of slope of 1 : 4~1 : 15. Two small open water areas were installed, in which emergent plants could not grow. Removal of nutrients from stream waters was a major objective of the wetland. Waters of Sinyang Stream flowing into Kohung Estuarine Lake were pumped and funneled into the wetland. The lake had been formed by a salt marsh reclamation project and was located southern coastal region of Korean Peninsula. Volumes and water quality of inflow and outflow were analyzed from July 2001 through December 2001. Inflow and outflow averaged $120.4m^3/day$ and $112.1m^3/day$, respectively. Hydraulic retention time was about 3.1 days. Average total phosphorous concentration of influent and effluent was $0.19mg/{\ell}$ and $0.075mg/{\ell}$, respectively. Total phosphorous loading rate of inflow and outflow averaged $12.05mg\;m^{-2}\;day^{-1}$ and $4.44mg\;m^{-2}\;day^{-1}$, respectively. Average total phosphorous removal rate in the wetland was $7.61mg\;m^{-2}\;day^{-1}$. Seasonal changes of phosphorous retention rates were observed. The wetland acted as effective phosphorous sinks in the initial stage of the constructed wetland.

Microglial activation induced by LPS mediates excitation of neurons in the hypothalamic paraventricular nucleus projecting to the rostral ventrolateral medulla

  • Han, Tae Hee;Lee, Heow Won;Kang, Eun A;Song, Min Seok;Lee, So Yeong;Ryu, Pan Dong
    • BMB Reports
    • /
    • 제54권12호
    • /
    • pp.620-625
    • /
    • 2021
  • Microglia are known to be activated in the hypothalamic paraventricular nucleus (PVN) of rats with cardiovascular diseases. However, the exact role of microglial activation in the plasticity of presympathetic PVN neurons associated with the modulation of sympathetic outflow remains poorly investigated. In this study, we analyzed the direct link between microglial activation and spontaneous firing rate along with the underlying synaptic mechanisms in PVN neurons projecting to the rostral ventrolateral medulla (RVLM). Systemic injection of LPS induced microglial activation in the PVN, increased the frequency of spontaneous firing activity of PVN-RVLM neurons, reduced GABAergic inputs into these neurons, and increased plasma NE levels and heart rate. Systemic minocycline injection blocked all the observed LPS-induced effects. Our results indicate that LPS increases the firing rate and decreases GABAergic transmission in PVN-RVLM neurons associated with sympathetic outflow and the alteration is largely attributed to the activation of microglia. Our findings provide some insights into the role of microglial activation in regulating the activity of PVN-RVLM neurons associated with modulation of sympathetic outflow in cardiovascular diseases.

교량세굴심 산정을 위한 만곡부하천에서의 산정식 적용성 평가 (Applicability Evaluation on the Analytical Formulas of the Scour Depth Estimation in the Bight River)

  • 박수진;박제완
    • 한국산학기술학회논문지
    • /
    • 제13권10호
    • /
    • pp.4845-4852
    • /
    • 2012
  • 본 논문은 교각의 세굴심 산정공식과 교대의 세굴심 산정공식을 적용하여 하천의 홍수량 및 만곡의 유 출입 각 변화에 따른 교량의 세굴심을 산정하고 이를 비교 검토하여 세굴심 산정식의 적용성을 평가하였다. 전체적으로 홍수량 및 유 출입 각이 증가할수록 만곡부의 세굴심 편차가 증가하였으며, 특히 유 출입 각 $105^{\circ}$에서 58%의 편차를 보여 이 지형에서의 교량계획시 신중한 검토가 필요할 것으로 판단된다. 다음으로 만곡부 산정공식별 만곡부의 세굴심 편차를 산정한 결과, 교각의 경우 Andru식이 58%를 Laursen식이 26%의 편차율을 보였으며, 다음으로 CSU. 식이 17%의 편차율을 보였다. 교대는 Froehlich 공식이 44%의 편차율을 보이고 있어 위 식의 세굴심 산정식 적용시 만곡부의 수리특성을 고려한 세굴심 산정이 필요한 것을 알 수 있다. 끝으로 세굴심의 편차를 크게 보인 유 출입 각 $45^{\circ}{\sim}135^{\circ}$에 대하여 홍수량에 따른 세굴심의 편차율을 회귀분석 하여 회귀식을 제안하였다.

Stereoscopic PIV 속도장 측정기법을 이용한 원통내의 회전 유동장 측정 (Visualization of rotational flow using SPIV in cylindrical tank)

  • 최종하;양근수;;손창현
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.44-47
    • /
    • 2004
  • Vortexing might occur during draining from tanks which reduces the rate of outflow. This phenomenon has practical relevance in the fuel feed system in space vehicles and rockets. Due to environmental disturbances rotational motion can be generated in the liquid-propellant tank, which in turn can affect the rate of outflow to the engines. The phenomenon is initialized by rotating the fluid In the experimental tank. The dip quickly develops into a vortex with an air core, which extends to the bottom port, reducing the effective cross-sectional area of the drain outlet and consequently the flow rate. Flow characteristics are investigated using SPIV(Stereoscopic Particle Image Velocimetry) method.

  • PDF

소유역의 지하수함양율 추정기법 (Estimation Methods of Groundwater Recharge Rate in Small Basin)

  • 박재성;김경호;전민우;김지수
    • 대한지하수환경학회지
    • /
    • 제6권2호
    • /
    • pp.76-86
    • /
    • 1999
  • 지하수 수요예측과 개발계획을 수립하기 위해서 지하수 함양율을 적절히 산정할 필요가 있다. 본 연구에서는 초정리 일원의 소유역을 선정하고 이 유역에 대해서 지하수 함양량 추정기법중 물수지분석법. SCS-CN 방법. 지하수위 강하곡선법 및 유출수문곡선법으로 함양율을 추정하였다. 물수지분석법과 SCS-CN 방법에서는 청주기상대의 10년 강우자료가 이용되었다. 지하수강하곡선법을 위해서는 1997년 한해 동안 3개의 관측정으로부터 얻은 지하수위자료를 이용하였고, 유출수문곡선법 적용시에는 3개년도의 수위.유량곡선자료가 이용되었다. 각 방법에 의한 함양율은 물수지분석법이 19%. SCS-CN 방법이 12.95%, 지하수강하곡선법이 16.5%. 그리고 유출수문곡선법이 10.9% 정도의 결과값을 보였다. 상기 방법들에 의해 계산된 이 유역의 지하수 평균함양율은 14.84%이었다.

  • PDF