• Title/Summary/Keyword: Outdoor insulator

Search Result 102, Processing Time 0.027 seconds

Effect of Filler and Additive on Performance of Cycloaliphatic Epoxy used for Outdoor Insulators (싸이클로알리파틱 에폭시 절연재료의 옥외 성능에 미치는 층전재 및 첨가물의 영향)

  • 허창수;연복희;서유진;이기택;김남렬;황명근;김완태
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.431-434
    • /
    • 2002
  • This paper reports on the evaluation of weathering resistance, tracking test and salt-fog of various kinds of cycloaliphatic epoxy systems. It was found that UV irradiation induced the loss of hydrophobic level due to the chain scission attack at the surface. It could be seen that samples containing an UV absorbent/antioxidant and a silicone oil additive knave a good performance in weathering ageing, whereas ATH filled ones have high resistance against tracking failure than others. Under salt-fog test, specimens mixed with silicone oil could suppress leakage current development. It was thought that silicone oil mixed into cycloaliphatic epoxy system could lead to lower the surface energy and to retain hydrophobic properties for a long time, which are desirable for outdoor performances.

  • PDF

Study on UV degradation in Polymeric Insulating Materials for Use in Outdoor Insulators by Corona-Charging (코로나 대전을 통한 옥외용 고분자 절연재료의 자외선 열화특성 연구)

  • Youn, Bok-Hee;An, Jong-Sik;Lee, Sang-Yong;Huh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.106-109
    • /
    • 2001
  • In this paper, we have investigated the degradation of shed materials of outdoor insulators by UV-radiation by using corona-charging and XPS analysis. The accumulated charges on polymeric surface having intrinsic hydrophobic property have a negative impact on retaining its hydrophobicity. Therefore, shorter decay times of surface charges are preferred. The surface voltage decay on UV-treated silicone rubber and EPDM show a different decay trend with UV treated time. From the XPS analysis, the oxidized groups of silica-like structure in silicone rubber increase with UV treatment time. For EPDM, the oxidized carbon groups of C=O, O=C-O increase as elapse of UV radiation time. These oxidized surface for each material have different electrostatic characteristics, so deposited charges may be expected to have different impacts on their surface hydrophobicity. The degradation mechanism based on our results is discussed.

  • PDF

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Lee, Un-Yong;Han, Dong-Hee;Kang, Sung-Hwa;Choi, In-Hyuk;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.1
    • /
    • pp.62-67
    • /
    • 2005
  • Recently, polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. Polymer material is also investigated it's tracking resistance by adding surface active agent in IEC 587. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination, STRI guide and thermal image camera.

A Study on Countermeasures and Tracking Phenomena of Polymer (절연용(絶緣用) 고분자재료(高分子材料)의 Tracking현상(現象)과 방지대책(防止對策)에 관한 연구(硏究))

  • Jeon, Young -Jun;Seo, Dong-Chul;Yoo, Jae-Il;Kim, Jin-Woo;Jung, Woo-Kyo;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1235-1238
    • /
    • 1995
  • Electrical property of polymeric insulating plays a key role in the trend of making power apparatus high voltage, and reliability and safety of apparatus in the long term depend on it. There is a recent trend of applying polymeric material to insulating material for outdoor, and particularly it is expected that it may be used partly as a pin insulator. Using as an alternate of insulating material for outdoor, however, it has still many problems to be solved in the field of material such as resistances of environment and tracking. It has been given attention to that the silicon rubbers and the epoxy have recently been used. but the the reliability in the viewpoint of material property becomes an issue. The polymeric materials such as EPDM, Epoxy and PVC have also been used as an insulating materials for outdoor. In this point of view, we studied each tracking phenomenon with test material such as rubber for pin, PVC for powercable used as an insulating material for outdoor, and Epoxy etc. The characteristics of anti tracking shows EPDM>Epoxy>PVC in order in the results. We also know that there is an close relationship between properties of tracking and thermegravimetry.

  • PDF

Analysis of Surface Degradation on Accelerated UV-treated Polymeric Housing Materials for Outdoor Insulator (자외선 가속열화에 따른 옥외용 폴리머 절연재료의 표면열화 분석)

  • Yeon, Bok-Hui;Lee, Sang-Yong;Heo, Chang-Su;Sim, Dae-Seop;Jo, Han-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.10
    • /
    • pp.479-488
    • /
    • 2001
  • The effects of accelerated Ultraviolet (UV) radiation on High temperature vulcanized (HTV), Room temperature vulcanized (RTV) silicone rubber and two types of ethylene propylene diene terpolymer (EPDM) used for composite insulator were inverstigated by hydrophobicity class (HC), surface voltage decay after corona charging, SEM-EDS, FTIR and XPS. The contact angle in two kinds of silicone rubber was scarcely change, but EPDM occurred to the loss of hydrophobicity followed by surface cracking and chalking. The surface voltage decay on UV-treated silicone rubber and EPDM showed a different decay trend with UV treatment. EDS and XPS analysis indicated that the oxygen content increased with UV treatment time in all samples. For silicone rubber, the oxidized groups of inorganic silica-like structure increased with UV treatment time. The oxidized carbon of C=0, O=C-O in EPDM increased. These oxidized surface for each material had different electrostatic characteristics, so deposited charges were expected to have different impacts on their surface hydrophobicity. The degradation mechanism based on our results was discussed.

  • PDF

S-Transform Based Time-Frequency Analysis of Leakage Current Signals of Transmission Line Insulators under Polluted Conditions

  • Natarajan, A.;Narayanan, Suthanthiravanitha
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.616-624
    • /
    • 2015
  • Flashover of power transmission line insulators due to contamination is a major threat to the reliable operation of power system. This paper deals with the analysis of leakage current characteristics of polymeric insulator using S-Transform technique in order to develop a better diagnostic tool to identify the surface condition of outdoor polymeric insulators. In this work, experiments were carried out on 11 kV silicone rubber insulator under AC voltage at different pollution levels. Moving average technique was adopted to find the trend followed by LC peak at different relative humidity conditions. S-Transform was used to find the relationship between energy and frequency content of the leakage current signal with respect to increase in pollution level over a period of time. From the S-Transform time-frequency contour analysis, point of transition to severe arcing due to increase in pollution and its thershold limit were evaluated. Reported results show that the surface condition of insulators could be easily identified from the S-Transform time-frequency analysis of leakage current signals.

A Study on Anti-Pollutions Characteristics of RTV Silicone Rubber (RTV 실리콘 고무의 내오손 특성에 관한 연구)

  • Huh, Chang-Su;Lee, Sang-Youb;Youn, Bok-Hee;Hwang, Myung-Kun;Lee, Jong-Han
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1651-1653
    • /
    • 1999
  • Room Temperature Vulcanizing (RTV) Silicone Rubber has been widely used to coat porcelain insulator to prevent formation water filming on insulator surface. and RTV silicone rubber has water repellency to suppress leakage current and consequent flashover. RTV silicone rubber's surface has been degradated by outdoor condition such as dust, salt, and water. etc. ESDD(Equivalent Salt Deposit Density) and leakage currents are increased by polymer surface toughness and degradation. In this paper, we investigated relations of surface toughness, ESDD, and leakage currents.

  • PDF

Investigations of Accelerated Aged Polymeric Insulators Using Partial Discharge Signal Measurement and Analysis

  • Mekala, K.;Chandrasekar, S.;Ravindran, R. Samson
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.299-307
    • /
    • 2015
  • Reduction in pollution performance of polymeric insulators, aged due to water absorption stress and thermal stress, is a major threat to the reliable operation of power transmission and distribution system. Formation of partial discharges on the surface of wet polluted insulator plays a major role in determining the life time and pollution performance of outdoor polymeric insulators. However, reports on partial discharge characteristics of water absorption stress aged and thermal aged polymeric insulators are scanty. This paper discusses the pollution performance characteristics of accelerated aged polymeric insulators using the advanced ultra wide band PD signal measurement and analysis. Laboratory experiments on accelerated aged polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. PRPD pattern and Time-Frequency map analysis of PD signals were carried out. From the results, it can be speculated that PD analysis is a well suited technique to understand the pollution performance of aged polymeric insulators.

Wavelet-Based Flashover Prediction Using High-Frequency Components (고주파 성분을 사용한 웨이블렛 기반 섬락 예측)

  • Song, Young-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.759-761
    • /
    • 2010
  • In order to monitor operating performance of contaminated outdoor insulators, a wavelet-based flashover prediction method is proposed. In most cases, the low-frequency components, namely, fundamental, $3^{rd}$, and $5^{th}$ harmonic components have been mainly used for the sake of the spectral analysis of the leakage current. However, in this paper, the detail coefficients of wavelet transform representing high-frequency components are used as important information to predict a flashover in the contaminated insulator. Experimental results verify that the proposed method has a superior capability for flashover prediction.

A Study Performance and Design Compositor Insulator for 170kV D/S (170kV급 단로기용 Composite Insulator 설계 및 특성 연구)

  • Cho, H.G.;Park, K.H.;Han, D.H.;Yoon, M.S.;Jin, S.Y.;Song, H.S.;Lee, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.252-254
    • /
    • 2003
  • Recently composite insulators are being used for outdoor high voltage applications. Composite insulators for transmission line have significant advantages over porcelain insulators, especially for ultra-high voltage. Their advantages are light weight, vandalism resistance, and hydrophobicity. We developed a 170kV high reliable vertical break disconnector with good long term electrical and mechanical performance which was achieved by the improvement of electrical performance and light weight. We discuss the outline of the development and the product.

  • PDF