• 제목/요약/키워드: Outdoor experiments

검색결과 266건 처리시간 0.021초

멀티존 네트워크 모델을 이용한 주거용 건물의 환기량 분석 (Analysis of Ventilation Rates in Residential Buildings using a Multizone Network Model)

  • 차지형;박철훈;김영하;백창인;한화택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.45-50
    • /
    • 2005
  • The supply outdoor airflow rates are calculated and analyzed using a multizone network model in a high-rise residential apartment. The system parameters include parameters related to weather conditions, building conditions, operation conditions, and facility conditions. Simulations are conducted according to the method of design of experiments and analysis of variance is conducted to investigate the effects of parameters on ventilation rate. A correlation equation is derived to predict ventilation rates of the building depending on the various parameters.

  • PDF

공랭식 열펌프의 습표면 핀-관 증발기의 현장 성능 시험 (In-Situ Performance Test of a Wet Surface Finned-Tube Evaporator of an Air Source Heat Pump)

  • 백영진;장영수;김영일
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.818-826
    • /
    • 2001
  • In this study, in-situ performance test of a wet surface finned-tube evaporator of an air source heat pump which has a rating capacity of 20RT is carried out. Since test conditions, such as indoor and outdoor air conditions cannot be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist, From the experimental data, air side heat and mass transfer coefficients were calculated by the well known heat and mass transfer analogy and tube-by-tube method. since current procedure underpredicted the experimental sensible heat factor(SHF), a proper empirical parameter was introduced to predict the experimental data with satisfactory results. This study provides the method of evaluating the heat and mass transfer coefficients of a wet surface finned-tube evaporator of which in-situ performance test in necessary.

  • PDF

바닥복사 난방시스템의 제어방식에 관한 실험적 연구 (An Experimental Study on the Control Methods of Radiant Floor Heating Systems)

  • 김오봉;이진영;여명석;석호태;김광우
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1297-1305
    • /
    • 2001
  • In this study, existing control methods that are suggested or applied until now are classified by control parameters, and stability of in the room and floor surface temperatures of each control method is compared through experiments. Then, the control performance of these control methods are analyzed to evaluate the applicability to Korean apartment housing. From the result of the applicability analysis, the outdoor reset with on/off PWM control is found to be desirable for district heating systems and flux modulation is found to be applicable for decentralized heating systems. In the case of independent control systems for each room, on/off PWM control is desirable.

  • PDF

Analysis of a Wet Surface Finned-tube Evaporator of an Air Source Heat Pump

  • Baik, Young-Jin;Chang, Young-Soo;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권4호
    • /
    • pp.211-219
    • /
    • 2002
  • In this study, in-situ performance test of a wet surface finned-tube evaporator of an air source heat pump which has a rating capacity of 20 RT is carried out. Since test conditions, such as indoor and outdoor air conditions cannot be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. From the experimental data, air side heat and mass transfer coefficients were calculated by the well known heat and mass transfer analogy and tube-by-tube method. Since current procedure underpredicted the experimental sensible heat factor (SHF), a proper empirical parameter was introduced to predict the experimental data with satisfactory results. This study provides the method of evaluating the heat and mass transfer coefficients of a wet surface finned-tube evaporator of which in-situ performance test is necessary.

멀티모달 정보변환을 통한 시각장애우 보행 보조 시스템 (Walking Assistance System for Sight Impaired People Based on a Multimodal Information Transformation Technique)

  • 유재형;한영준;한헌수
    • 제어로봇시스템학회논문지
    • /
    • 제15권5호
    • /
    • pp.465-472
    • /
    • 2009
  • This paper proposes a multimodal information transformation system that converts the image information to the voice information to provide the sight impaired people with walking area and obstacles, which are extracted by an acquired image from a single CCD camera. Using a chain-code line detection algorithm, the walking area is found from the vanishing point and boundary of a sidewalk on the edge image. And obstacles are detected by Gabor filter of extracting vertical lines on the walking area. The proposed system expresses the voice information of pre-defined sentences, consisting of template words which mean walking area and obstacles. The multi-modal information transformation system serves the useful voice information to the sight impaired that intend to reach their destination. The experiments of the proposed algorithm has been implemented on the indoor and outdoor environments, and verified its superiority to exactly provide walking parameters sentences.

온돌을 이용한 바닥복사냉방의 제습시스템 적용에 관한 연구 (A Study on the Application of the Dehumidification System for Radiant Floor Cooling Using Ondol)

  • 임재한;여명석;양인호;김광우
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.607-616
    • /
    • 2002
  • This study has been conducted to evaluate the applicability of the control method in the dehumidification-integrated radiant floor cooling system in terms of stability of the room air temperature and the control variables through experiments. To do this, the relationship between the control variables in preventing floor surface condensation is first analyzed and the control method is predetermined through simulations. The results are as follows. First, it is necessary to determine the operation status of the dehumidification system according to the relationship between floor surface temperature and dew point temperature in the conditioned space. Second, outdoor reset with indoor temperature feedback control is better than on/off bang-bang control with respect to temperature stability in controlling the room air temperature and the possibility of energy savings. Finally, the humidity sensor can be located with the current thermostat in that there are small differences in absolute humidity in vertical distribution.

On-site Performance Test and Simulation of a 10 RT Air Source Heat Pump

  • Baik, Young-Jin;Chang, Young-Soo;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.61-69
    • /
    • 2004
  • In this study, on-site performance test of an air source heat pump which has a rated capacity of 10 RT is carried out. Since indoor and outdoor air conditions can not be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. To estimate the performance of the heat pump for other conditions, the heat pump is modeled with a small number of characteristic parameters. The values of the parameters are determined from the few measurements measured on-site during steady operation. A simulation program is developed to calculate cooling capacity and power consumption at any other arbitrary operating conditions. The simulation results are in good agreement with the experiment. This study provides a method of an on-site performance diagnosis of an air source heat pump.

SIFT 기반의 귀 영역을 이용한 개인 식별 (Individual Identification Using Ear Region Based on SIFT)

  • 김민기
    • 한국멀티미디어학회논문지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2015
  • In recent years, ear has emerged as a new biometric trait, because it has advantage of higher user acceptance than fingerprint and can be captured at remote distance in an indoor or outdoor environment. This paper proposes an individual identification method using ear region based on SIFT(shift invariant feature transform). Unlike most of the previous studies using rectangle shape for extracting a region of interest(ROI), this study sets an ROI as a flexible expanded region including ear. It also presents an effective extraction and matching method for SIFT keypoints. Experiments for evaluating the performance of the proposed method were performed on IITD public database. It showed correct identification rate of 98.89%, and it showed 98.44% with a deformed dataset of 20% occlusion. These results show that the proposed method is effective in ear recognition and robust to occlusion.

멀티에어컨의 성능해석 프로그램 개발 (Development of Simulation Program for Multi-Air conditioner)

  • 정백영;고재윤;박병덕;임장순
    • 태양에너지
    • /
    • 제20권1호
    • /
    • pp.63-72
    • /
    • 2000
  • In this study, theoretical simulation method for the steady state characteristics of a refrigeration cycle which consists of one condenser and multi-evaporator (Multi-air conditioner) is presented. The simulation was performed for a typical multi-air conditioning system consisted one outdoor unit with air-cooled condenser, compressor, linear electric expansion valve and bypass circuit and connected three-evaporators (three indoor units). The simulation results are good agreement with those of experiments within 5 $\sim$ 10% at the given system operation conditions which are condensing pressure, evaporating pressure, sub-cooled degree of condenser, superheated degree, discharge temperature of compressor and pulse of linear electric expansion valve.

  • PDF

격리병실내 급배기구 위치에 따른 오염물 제거효율 비교 (Comparison of pollutant removal efficiency according to the locations of the supply and exhaust)

  • 원안나
    • 도시과학
    • /
    • 제9권2호
    • /
    • pp.13-20
    • /
    • 2020
  • The Recently, several countries have been affected by respiratory diseases, resulting in renewed research interest in their prevention and control. One such example was the 2015 outbreak of Middle East Respiratory Syndrome (MERS) in South Korea and COVID-19. In this study, we performed experiments and simulations based on concentration decay using CO2 as the tracer gas to elucidate the pollutant-removal efficiency for different inlet and exhaust locations and outdoor air-supply ratios. The wall inlet exhibited a higher pollutant-removal efficiency, owing to the upward movement of the air from the lower zone to the upper one. In conclusion, it is recommended that a total air-conditioning plan for isolation rooms be established as well as efficient system operation for pollutant removal and air-flow control to prevent the transmission of infections from the patients to others.