• Title/Summary/Keyword: Outdoor experiments

Search Result 266, Processing Time 0.02 seconds

Experimental Outdoor Visible Light Data Communication Systems with Optical Filter (광필터를 이용한 실험적 실외 가시광 통신 시스템)

  • Kim, Yong-Hyeon;Chung, Yeon-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.1840-1846
    • /
    • 2014
  • An experimental outdoor optical wireless data communication system with an optical filter in the presence of sunlight or artificial light is presented. For the efficient blocking of light noise outdoors, we employ an optical filter made of microlouver film on the top of the photo diode. This filter is designed to block any light noise incident from an angle higher than $30^{\circ}$ on the assumption that light noise does not face the photo diode horizontally. Outdoor experiments daytime with the optical filtering have been conducted. The experimental results demonstrate that the optical filter effectively blocks nearly all light noise incident from the specified angle or higher and more than 90% of the transmitted data packets are successfully received. The proposed outdoor visible light data communication can thus facilitate a practical free space outdoor optical wireless data transmission.

A Study on Experiments the Environmental Conditions and the Adaptation of the Human Body in the Vinyl House (Vinyl House 내의 환경조건과 인체적응에 관한 실험연구)

  • Shim, Bu-Ja
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.1 s.45
    • /
    • pp.59-73
    • /
    • 1994
  • The purpose of this study is to experiments the environmental conditions and the adaption of the human body in the vinyl house. The study was done in spring and winter and experimental clothes were used working clothes in the vinyl house. The results are as follows. 1. Environmental Conditions In the spring season, the indoor air temperature was $27.4{\pm}3.7^{\circ}C$ and the outdoor air temperature was $14.4{\pm}2.7^{\circ}C$. In the winter season, the indoor air temperature was $18.3{\pm}4.8^{\circ}C$ and the outdoor air temperature was $7.6{\pm}2.5^{\circ}C$ on the average. 2. Skin Temperature In the spring season, the mean skin temperatures indoor and outdoor were $33.81{\pm}0.7^{\circ}C\;and\;31.57{\pm}0.8^{\circ}C$ respectively, a difference of $2.24^{\circ}C$. In the winter season, they were $31.95{\pm}1.93^{\circ}C\;and\;29.86{\pm}0.55^{\circ}C$ respectively, a difference of $2.09^{\circ}C$. 3. Clothing Climate In the spring season, the temperature and humidity in the inner layer of clothing were $34.77{\pm}0.80^{\circ}C\;and\;70.75{\pm}1.65%$ indoor, $31.9{\pm}0.52^{\circ}C\;and\;51.9{\pm}3.70%$ outdoor respectively. In the winter season, those were $32.52{\pm}1.04^{\circ}C\;and\;64.65{\pm}3.68%$ indoor, $30.27{\pm}0.96^{\circ}C\;and\;45.07{\pm}2.68%$ outdoor respectively. 4. Physiological Factors Body temperature increased slightly and the pulse rate also rises, but blood pressure decreased a little with the rise of environmental temperature both in the spring and winter seasons. 5. Psychological Factors Thermal sensation in the spring season was expressed as 'slightly warm' or 'warm' indoor and as 'neutral' in the open air, while in the winter it was expressed as 'neutral' or 'slightly warm' outdoor the house and as 'cold' in the open air. Comfort sensation was characterized as 'uncomfortable' or 'slightly uncomfortable' indoor both in the spring and winter seasons, but in the open air it was characterized as 'comfortable' in the spring and as 'slightly uncomfortable' in the winter.

  • PDF

Development of Magnet Position Device for Outdoor Magnet Guidance Vehicle (실외 자기유도 무인운반차를 위한 자기 위치측정 장치 개발)

  • Cho, Hyunhak;Kim, Sungshin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.3
    • /
    • pp.259-264
    • /
    • 2014
  • This paper is research paper on the MPD(Magnet Position Device) for the outdoor MGV(Magnet /Magnet Gyro Guidance Vehicle). Usually, MGV is used in indoor environment because of a measurement height of the magnet position device. CMPD(Commercial magnet position device) has 30 mm measurement height, so this is suitable structure in indoor environment like to a flat surface. Outdoor environment is an uneven and irregular, So Outdoor MGV must has a suspension. But CMPD is unsuitable for outdoor environment because of a collision with a surface caused by suspension. Thus, measurement height of the outdoor MPD is positively necessary more than 100 mm. So, we suggest the outdoor MPD using analog magnet hall sensor, moving average filter and Characteristic(rate of the magnet hall sensor) function of the localization. Result of the experiments, the proposed Magnet Position Device for the outdoor MGV has localization accuracy 4.31 mm, measurement height 150 mm and width 150 mm and is efficient more than CMPD.

A Study on the Distribution of the Peak Wind Pressure for Rooftop Signboards (건물 옥상에 설치되는 옥상 간판의 피크풍압 분포에 대한 연구)

  • Nam, Byung-Hee;You, Jang-Youl;Lee, Nam-Hun;You, Ki-Pyo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.2
    • /
    • pp.79-86
    • /
    • 2018
  • Unlike other types of outdoor advertisements, rooftop signboards are installed on the roofs of buildings, rather than on their outer walls. This means that the area of a rooftop signboard is commonly larger than that of a general outdoor signboard. Moreover, as such signboards are greatly influenced by the wind, they can suffer a lot of damage from typhoons and strong winds every year. However, there is no wind load specification for rooftop signboards. In this study, wind pressure experiments were conducted to investigate the peak wind pressure on each side of rooftop signboards installed on the roofs of 5-15 story buildings in a city center. The minimum peak wind pressure coefficient was -3.0 at the bottom edges of the front and back of the rooftop signboards and -2.0 along the entire length of the sides. As the height of the rooftop signboard increased with the increasing height of the buildings, the peak value was found to be larger than the absolute peak value for the minimum peak wind pressure coefficient. The maximum and minimum peak wind pressure distributions of the rooftop outdoor signboards were influenced by the position of the signboard and the wind angle.

Cooling Performance Evaluation study of Dual-Source Heat Pump System (2중열원 히트펌프시스템의 냉방성능예측에 관한 연구)

  • Noh, Kwan-Jong;Kim, Ji-Young;Kang, Eun-Chul;Park, Hye-Moon;Lee, Euy-Joon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • A steady-state simulation model for Dual-Source Heat Pump(DSHP) of 8RT was presented. A Dual-Source Heat Pump(DSHP) has been designed to make up for the conventional air source heat pumps. The performance evaluation has been conducted under internal standard test conditions such as ISO-13256-1 and KS C 9306. However, as test conditions such as entering water, indoor and outdoor air conditions could not be controlled to satisfy the standard test conditions in outdoor tests, a series of experiments have been conducted with the actual test conditions. Then, computer models for DSHP could be used for the standard condition have developed using EES program. The model was developed from basic thermodynamic principles and heat transfer relations. Most of the parameters were obtained with EES from the actual catalog data. The simulation results were in good agreement with the experiments.

  • PDF

Real-Time Prediction of Optimal Control Parameters for Mobile Robots based on Estimated Strength of Ground Surface (노면의 강도 추정을 통한 자율 주행 로봇의 실시간 최적 주행 파라미터 예측)

  • Kim, Jayoung;Lee, Jihong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.1
    • /
    • pp.58-69
    • /
    • 2014
  • This paper proposes a method for predicting maximum friction coefficients and optimal slip ratios as optimal control parameters for traction control or slip control of autonomous mobile robots on rough terrain. This paper focuses on strength of ground surface which indicates different characteristics depending on material types on surface. Strength of various material types can be estimated by Willoughby sinkage model and by a developed testbed which can measure forces, velocities, and displacements generated by wheel-terrain interaction. Estimated strength is collaborated on building improved Brixius model with friction-slip data from experiments with the testbed over sand and grass material. Improved Brixius model covers widespread material types in outdoor environments on predicting friction-slip characteristics depending on strength of ground surface. Thus, a prediction model for obtaining optimal control parameters is derived by partial differentiation of the improved Brixius model with respect to slip. This prediction model can be applied to autonomous mobile robots and finally gives secure maneuverability on rough terrain. Proposed method is verified by various experiments under similar conditions with the ones for real outdoor robots.

A Study on Combustion Experiments of Multi Type Air-Conditioner Outdoor Units by Large Scale Calorimeter (라지스케일 칼로리미터에 의한 멀티시스템형 에어컨실외기의 연소실험에 관한 연구)

  • Min, Se-Hong;Bae, Yeon-Jun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.168-177
    • /
    • 2011
  • The combustion test for real box of AC outdoor unit has been performed in this study in order to estimate the fire hazard in multi-system type of AC outdoor unit which is currently used for commercial use. The result showed that in test, there was explosion inside of AC outdoor unit, and flame erupted and fire spread through upper side grill. And then this fire burnt the combustibles such as wires, electronic control board, heat exchange copper plate and plastics etc inside the unit, refrigerant gas pipe was burst due to fire, and accelerated the explosion and flame eruption to outside while the refrigerant was erupting. It is found in this test that the maximum heat release rate of AC outdoor unit is 5,830 kW, the maximum internal temperature measured with infrared camera and thermocouple is $1,201^{\circ}C$, maximum ambient temperature is $881^{\circ}C$, and flame rose higher than about 5 m. It is concluded that the fire in AC outdoor unit cause fire to combustibles around the unit, and may give big damage by generating the secondary fire. It is expected that the result obtained from the test on the real object may be applied to fire realization of AC outdoor unit and estimation of fire spreading to the combustibles around in the future computer simulation.

Human Solar Heat Load and Thermal Comfort in an Outdoor Environment (건축외부공간에 있어서 인체의 일사열부하(日射熱負荷) 및 열적(熱的) 쾌적성(快適性)에 관한 실험적 연구)

  • Jeong, Chang-Won;Yoon, In
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.1 no.2
    • /
    • pp.65-74
    • /
    • 1998
  • The purpose of this paper is to investigate the mount of relief of human solar heat load and thermal comfort in outdoor environment in summer, Six different types of sites, T garden and its neighboring area in Japan, were selected as the experiment sites. The experiments were conducted from 22 to 29 August, 1994 to find the relationship between climatic conditions and human responses, Climatic conditions, subjects's thermal sensation and skin temperature were measured. Radiant heat exchange on the human body was estimated on the basis of the measured air and surface temperature and solar radiation. Thermal index Operative Temperature and New Effective Temperature was modified with the effect of the radiant heat exchange. Human thermal comfort and skin temperature is affected by the solar radiation and the sky factor in an outdoor environment. The effect of tree shade was verified on thermal comfort, The mount of relief of human solar heat load is relation to the existence of shade a solar radiation and the sky factor. The urban garden is one of the effective design element in an urban environmental planning.

  • PDF

A Study of the Photo-Electric Efficiency of Dye-Sensitized Solar Cells Under Lower Light Intensity

  • Kim, Hee-Je;Kim, Yong-Chul;Hong, Ji-Tae;Kim, Mi-Jeong;Seo, Hyun-Woong;Park, Je-Wook;Choi, Jin-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.513-517
    • /
    • 2007
  • To elucidate possible challenges for outdoor practical use of dye-sensitized solar cells (DSCs), we compared conventional Si solar cells with DSCs. DSC modules still require a larger area than conventional Si solar modules to attain the same rated output because of lower photoelectron-chemical conversion efficiency. However, in backup systems by using batteries, the measured data shows that DSCs generated 15% more electricity than Si solar cells of the same rated output power in the same interval of cloudy daylight. Moreover, the battery charging time of DSCs is about 1 hour faster than the same rate of Si solar cells under outdoor cloudy daylight. This result also indicates that conversion efficiency obtained by the certified condition less than AM 1.5 condition does not always coincide with the electricity generated outdoors daily, and it is not a crucial measure to evaluate the performance of solar cells.

Robust Positioning-Sensing for n Ubiquitous Mobile Robot (유비쿼터스 모바일 로봇의 강인한 위치 추정 기법)

  • Choi, Hyo-Sik;Hwang, Jin-Ah;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.11
    • /
    • pp.1139-1145
    • /
    • 2008
  • A robust position sensing system is proposed in this paper for a ubiquitous mobile robot which moves indoors as well as outdoors. The Differential GPS (DGPS) which has a position estimation error of less than 5 m is a general solution when the mobile robot is moving outdoor, while an active beacon system (ABS) with embedded ultrasonic sensors is reliable as an indoor positioning system. The switching from the outdoor to indoor or vice versa causes unstable measurements on account of the reference coordinates and algorithm changes. To minimize the switching time in the position estimation and to stabilize the measurement, a robust position sensing system is proposed. In the system, to minimize the switching delay, the door positions are stored and updated in a database. Using the database, the approaching status of the mobile robot from indoor to outdoor or vice versa has been checked and the switching conditions are prepared before the mobile robot actually moves out or moves into the door. The reliability and accuracy of the robust positioning system based on DGPS and ABS are verified and demonstrated through the real experiments using a mobile robot prepared for this research.