• Title/Summary/Keyword: Outdoor air conditioning system

Search Result 212, Processing Time 0.024 seconds

Analysis on the Ventilation Rate of Express Bus according to the Geometry of Vent (고속버스의 환기구 형태에 따른 환기량 분석)

  • Shin, In-Hwaw;Yoo, Ho-Chun
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.174-178
    • /
    • 2011
  • This paper deals with the free cooling system of express bus using natural energy source in order to improve the room air quality and save cooling energy. In an express bus, there are may passengers in unit area, requiring the improvement of air quality and giving higher energy saving efficiency. Particularly, the express buses running fast make it easy to take in outdoor air at a flow rate controllable with a damper mechanism. This paper proposes the analysis on the air flow achieved by a damper controlled vertically and horizontally in order not to deteriorate the ride comfort of the passengers.

  • PDF

Thermal Environment Analysis by the Diffusion Direction with Ceiling Type Air Conditioner of the Classroom (학교 교실의 천장형 에어컨 토출각도에 따른 온열환경 해석)

  • AHN, Chul-Lin;KIM, Dong-Gyue;KUM, Jong-Soo;PARK, Hee-Ouk;CHUNG, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.17 no.2
    • /
    • pp.145-154
    • /
    • 2005
  • It is necessary to develop new air-conditioning method which can be satisfied individual separated space and request of occupants. The indoor thermal environment and flow field are investigated both experimentally and numerically. This study concentrated on analysis of indoor thermal environment by diffusion direction of ceiling type air conditioner of the classroom. The velocity and temperature distribution of air in the room calculated by 3-dimensional method, which include the effect of insulation of the building and outdoor state. This analysis shows that optimum diffusion direction is $30^{\circ}$ to increase thermal comfort in winter and optimum diffusion direction is $15^{\circ}$ to increase thermal comfort in summer.

Improvement of Indoor Air Environment in a Large Welding Factory by Displacement Ventilation (변위환기를 이용한 대형 용접작업장의 공기환경 개선에 관한 연구)

  • Cho, Dong-Hwan;Kang, Seok-Youn;Choi, Choong-Hyun;Im, Yun-Chul;Lee, Jae-Heon;Moon, Jung-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.69-74
    • /
    • 2005
  • In this paper, the indoor air environment in a large welding factory applied to displacement ventilation was investigated with experiment and numerical analysis for previous and new ventilation system. Concentration of fumes was analyzed for three cases with wind direction of outdoor. For experimental results, the dust concentration with new ventilation system decreased about 42-60% and the visibility increased about 11-18%. For numerical analysis, the exhaust efficiency of fumes was low when the wind and exhaust flow direction was inverse. It was found that the fumes in the factory decreased about 77% in case of the northern wind.

  • PDF

Analysis of the Top Loss Coefficient for Flat Plate Collector in a Solar Air-Conditioning System during Winter (태양열 이용 냉난방 공조시스템중 평판형 집열기의 동계 상부 열손실 해석)

  • Kim, B.C.;Choi, K.H.;Kum, J.S.;Kim, J.R.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.15-24
    • /
    • 1998
  • There are mainly 3 heat losses from solar collector; top, bottom, and edge heat loss. Usually edge heat loss is small so that could be neglected. Of the total thermal losses occurring in a flat plate solar collector, top loss heat losses are dominant. Therefore it is necessary to calculate the top loss coefficient accurately in order to find out performance of solar collector. The flat plate solar collector(regenerator in summer) used in this study was made for year-round all conditioning. In order to find out collector efficiency for heating in winter without a system change, outdoor experiment was done. The top loss coefficient of this collector was about 3 to $4.5W/m^2^{\circ}C$. Futhermore use of selective coating in trickling surface can improve a performance of flat plate solar collector.

  • PDF

Simulation Study on the Performance Improvement of a $CO_2$ System Applying a Two-stage Phase-separate Cycle (2단압축 상분리 사이클을 적용한 이산화탄소 시스템의 성능향상에 관한 해석적 연구)

  • Ryu Chang-Gi;Lee Ho-Seong;Kim Yong-Chan;Cho Hong-Hyun;Cho Sung-Wook
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.641-648
    • /
    • 2006
  • In this study, a two-stage phase-separate cycle was investigated analytically to improve the performance of the $CO_2$ system in the cooling mode. The simulation results were verified with the measured data. The predictions using the simulation model were consistent with the measured data within ${\pm}20%$ deviations. The performance of the modified $CO_2$ system with the two-stage phase-separated cycle was analyzed with the variations of outdoor temperature and EEV opening. The cooling COP decreased with the increase of compressor frequency. The highest COP was 2.7 at compressor frequencies of 30 Hz and 30 Hz for the first and second compressors, respectively. In addition, the cooling COP increased by 9.3% with an application of optimum control of the first and second-stage EEV openings.

An Analysis of Heating and Cooling Loads by Insulated Shades and Control Method in an Energy Saving Apartment (에너지절약형 주택에서의 단열차양 적용과 제어방법에 따른 냉난방부하 분석)

  • Park, Sun-Hyo;Kwon, Kyung-Woo;Sohn, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.392-397
    • /
    • 2010
  • Energy loss from windows accounts for large scores of heating and cooling loads also in energy saving apartments that is reduced over 30% of total energy consumption. Movable reflective insulations, insulation shutters, blinds, insulated shades are used to reduce energy loads from windows. In this study, energy saving performance of insulated shades was simulated by control methods. According to installation of insulated shades, heating loads were decreased about 10.5~11.3%, and cooling loads are decreased about 29.1~38.3% on an energy saving apartment. The heating peak load was reduced about 9.5% by insulated shades and the cooling peak load was reduced about 25.7~31.5%. In the case of insulated shades with automatic control system, simple time schedule control system would be more efficient than outdoor detection control system that should use several sensors.

Optical Analysis and Experimental Method for Design of Radiative Thermal Reflector (복사열 반사판의 설계를 위한 광학적 해석 및 실험기법)

  • Jung, Hae-Yong;Song, Tae-Ho;Yoo, Seung-Yeol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.8
    • /
    • pp.563-569
    • /
    • 2008
  • Radiative, heating is suitable for outdoor heating system in windy and cold seasons. Optimal design of the reflector is very important to maximize heat transfer to a specific target area in the open space. The geometrical optical theory can be applied to analyze efficiency of the reflector. Commercial ray tracing computer programs are available only for limited geometries of the reflector. Alternatively, it may be designed and analyzed through an approximated simple lens theory. Two types of reflectors are analyzed using either of these methods. The key issue in this paper is to propose a new illumination experimental method for determination of the radiative efficiency. Optical light source and illuminometer are employed. The calculated efficiency of the reflector is compared with experimental one for checking the reliability. The relative errors between the experimental and analytical results are less than 5%, which proves the validity of this method. Based on these methodologies, a practical reflector and heating lamp unit is developed.

Analysis of the Energy Saving Effect for the External Insulation Construction by Building Load Calculation Method (건물 부하계산 프로그램을 이용한 외단열 시공의 에너지 절감 효과 분석)

  • Park, Jaejoong;Myeong, Jemin;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.97-104
    • /
    • 2017
  • Reinforcement of insulation in apartment buildings reduces the heating and cooling energy consumption by lowering the heat transfer in the building envelope. There are differences between internal and external insulation methods in heat transmission properties. However, some building load calculation programs cannot analysis the differences between the two. This is because these programs do no account for the timelag or thermal storage effect of the wall according to the location of insulation. In this study, the heat transmission characteristics of internal and external insulation were analyzed by EnergyPlus, and heating and cooling energy demand was compared. The results showed that external insulation system had lower heating and cooling loads than internal insulation system. Also the heat transfer rate of external insulation is steadier than internal insulation. About 13.6% of heating and cooling energy demand decreased when the outdoor wall was finished with external insulation compared to the demand with internal insulation.

Simulation Study on the Performance Characteristics of a $CO_2$ Cooling System with an Expander (팽창기를 적용한 이산화탄소 냉방시스템의 성능특성에 관한 해석적 연구)

  • Cho, Hong-Hyun;Baek, Chang-Hyun;Ryu, Chang-Gi;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.630-639
    • /
    • 2007
  • A $CO_2$ cycle shows large throttling loss during the expansion process. The application of an expander into the $CO_2$ cycle can reduce the throttling loss and then improve system performance. In this study, the performance of a transcritical $CO_2$ cycle with an expander was analytically investigated in order to improve the cooling performance of the system. The expander was applied to the single-stage and two-stage compression cycles. The performance was analyzed with the variations of compressor frequency, outdoor temperature, and expander efficiency. The single-stage and two-stage compression cycles with the expander showed COP improvement of 25% and 32%, respectively, over the single-stage cycle with an EEV.

Comparison of pollutant removal efficiency according to the locations of the supply and exhaust (격리병실내 급배기구 위치에 따른 오염물 제거효율 비교)

  • Won, An-Na
    • Journal of Urban Science
    • /
    • v.9 no.2
    • /
    • pp.13-20
    • /
    • 2020
  • The Recently, several countries have been affected by respiratory diseases, resulting in renewed research interest in their prevention and control. One such example was the 2015 outbreak of Middle East Respiratory Syndrome (MERS) in South Korea and COVID-19. In this study, we performed experiments and simulations based on concentration decay using CO2 as the tracer gas to elucidate the pollutant-removal efficiency for different inlet and exhaust locations and outdoor air-supply ratios. The wall inlet exhibited a higher pollutant-removal efficiency, owing to the upward movement of the air from the lower zone to the upper one. In conclusion, it is recommended that a total air-conditioning plan for isolation rooms be established as well as efficient system operation for pollutant removal and air-flow control to prevent the transmission of infections from the patients to others.