• Title/Summary/Keyword: Outdoor Noise

Search Result 198, Processing Time 0.237 seconds

A study on the acoustic performance test method using speaker of a noise reduction device for noise reduction of the 400km/h class high-speed railroad (스피커를 이용한 400km/h급 고속철도 소음저감용 방음벽 상단장치의 음향성능 시험방법에 관한 연구)

  • Yoon, Je-Won;Kim, Young-Chan;Jang, Kang-Seok;Eum, Ki-Young;Jang, Seung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.625-629
    • /
    • 2014
  • For the purpose of the acoustic performance evaluation of noise reduction device(NRD) installed at the top of noise barrier for further decreasing of noise level of 400km/h class high-speed railroad(HEMU), the acoustic performance test method using speaker instead of really running railway vehicle was suggested in this paper. For this, noise source location and frequency spectrum of HEMU was analyzed through the field noise test. These data were used for the determination of speaker's installation positions and frequency correction values applied to the speaker noise source. And, 400 meters long NRD was installed at the site where HEMU will be running at a speed of 400km/h. Finally, the outdoor speaker test with and without NRD showed that this NRD could decrease noise level even more than 3dB(A). In the future, the acoustic performance results of NRD conducted with speaker test will be compared with that of field test for HEMU running at a speed of 400km/h.

  • PDF

The performance enhancement with multiple antenna algorithm between indoor and outdoor wireless communication (옥내와 옥외간 무선 통신에서 다중 안테나 알고리즘 적용을 통한 통신 성능 향상)

  • Lee Junho;Lee Yong Up;Seo Youngjun;Baang Sungkeun;Kim Jong Dae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.5C
    • /
    • pp.355-363
    • /
    • 2005
  • This paper is discussed about the technology of the performance enhancement in the wireless communication between indoor and outdoor environments. In the outdoor wireless communication, the signal has mainly a severe degradation by the fading effect of channel, but that problem may be overcome by using ordinary multiple antenna technology and array signal processing algorithm. Hence, since the channel has the characteristics of both fading and angle spread in the wireless communication between indoor and outdoor, the ordinary technology cannot solve the signal degradation due to the angle spread. In order to solve the problem, in this paper, the characteristic of the wireless channel between indoor and outdoor is first analyzed and considered the channel models fit to that case. We propose the new multiple antenna algorithm by use of mean steering vector concept, and obtained the results of the performance enhancement. With the results of the performance analyses through of the numerical study and computer simulation, we show that the proposed algorithm has more enhanced signal to noise ratio than the previous algorithm.

Characteristics of Interior Noise at University Reading Room and User's Consciousness on the Noise (대학 독서실에서 발생하는 소음의 특성과 사용자 의식 분석 - C 대학교의 독서실을 대상으로 -)

  • Park, Hyeon Ku;Jong, Hye-Ran;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.39-44
    • /
    • 2010
  • Reading room in the university is one of necessary facilities that university student must use. It is, therefore, very important to make reading room comfortable acoustically not only to minimize the annoyance to the users but also to provide efficiency in studying. Present study aims to investigate the current situation of reading room in terms of acoustics and moreover to find out the relationship between the indoor noise and users' satisfaction through questionnaire survey. As a result, the indoor noise level is quite higher than the 1st grade, 35 dB(A), that the Ministry of land, transport and maritime affairs suggests as certificate regulation for environment friendly building and there were lots of noise sources that can provoke users in studying or concentrating. Questionnaire survey illustrates that the sound when opening and closing door, and airborne sound from outdoor transmitted through window are most annoying, which affected users' dissatisfaction.

An Experimental Study on the Prediction of Indoor Sound Level Distribution in Apartment for Exterior Noise (외부소음에 대한 공동주택 실내 소음레벨분포에 관한 실험적 연구)

  • Park, Hyeon-Ku;Kim, Jong-Bin;Kang, Dong-Yong;Jang, Hyun-Choong;Song, Hyuk;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.259-264
    • /
    • 2001
  • It is necessary to predict the sound pressure level(SPL) in rooms before designing an apartment when exterior noises are produced. In order to predict SPL for an apartment that has some specific exterior noises, the following should be known: the characteristics of outdoor noise, sound insulation performance and sound level differences of each room. The purpose of this study is to find out the possibility of predicting sound pressure level of rooms in an apartment by analysing sound level differences among rooms. Sound sources used in this experiment are construction noise, aircraft noise, railroad noise, road traffic noise and white noise as a reference to compare with the previous four. These noises were recorded and reproduced by speaker. As a result, we found that within the sound reduction pattern, the sound difference level appeared uniform depending on the sound insulation characteristics of the windows installed when facing the noise source. When the windows having the same acoustic performance were installed, the SPL in each room resulted in nearly the same values.

  • PDF

Evaluation of Present Status for the Korean Noise Map Standardization (국내소음지도 표준화를 위한 현황 평가)

  • Park, In-Sun;Park, Sang-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.517-520
    • /
    • 2005
  • Noise mapping covers the whole mapping process from the collection of raw data, storage and retrieval of the data for computation/modeling, to the presentation of information related to outdoor sound levels, sound exposure, noise effects or numbers of affected person. This presentation can be in either a graphical or numerical form. In Europe, the Directive 2002/49/EC of the European Parliament and of the Council relating to the assessment and management of environmental noise is now being implemented in the EU Member States. Here, The first maps for major areas are required by mid 2007, and action plans required one year later. These activities are repeated at five yearly intervals and all defined areas are incorporated in the following round of deadlines starting in 2012. The above are minimum requirements and some countries are expected to go further and faster. In this study, present status of domestic and international noise maps has been introduced to implemente the Korean noise map standard. This will help to get more convenient and, more fair result, and produce correct map at domestic level.

  • PDF

A Study on the Tank Noise Reduction Techniques of Power Transformers (전력용 변압기 외함 소음저감에 관한 연구)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Kim, Jung-Chan;Kim, Yoo-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1759-1766
    • /
    • 2008
  • According to the increase of power demand and expansion of downtown, it is necessary to install transformers additionally in operating substations and construct substations in residential area. But the public complaint has been increased due to the transformer noise of the substation. KEPCO has used a vibration preventing pad, various soundproof walls and an encloser to transformers in outdoor substations, and a soundproof door, shutter and wind-path soundproof equipment in indoor substations to block the sound propagation from the transformers. But these noise reduction methods are not satisfied. It should be considered to reduce transformer noise itself. In this paper, we investigated tank noise reduction techniques to develope a low noise transformer. According to the mode analysis of transformer tank, we found out characteristics and locations of noise on the tank, and it's nature vibration was also analysed. On the basis of these analysis, reinforcement equipment was installed around transformer tank, and ellipse shape tank was changed to round shape tank. The effect of noise reduction was evaluated using noise generation source.

Noise Measurement Method Development and Correlation Analysis According to Measurement Location of Small Unmanned Robot (소형 무인 로봇의 소음 측정법 개발 및 측정 장소에 따른 상관성 분석)

  • Ok, Jinkyu;Park, Eunjoo;Park, Minsu;Lee, Myungchun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.633-638
    • /
    • 2017
  • The small unmanned robot developed in this paper can perform tasks such as surveillance and reconnaissance in the battle field. The noise generated during the operation of the robot may expose the operation area. Therefore, in this study, we developed a method to quantitatively measure the noise of the developed small unmanned ground robot. The criteria for noise measurement in indoor and outdoor are presented. It was used for statistical verification method to verify the reliability of the developed noise measurement method. The noise was measured at different places, and the correlation was analyzed. Thus, we proposed a method to predict the noise level in the operation area where the robot is operated by the noise test data measured during the development process.

Highspeed Train : Sound Power and Noise Propagation Characteristics (고속철도의 소음 특성과 전파현상)

  • 김정태;은희준
    • Journal of KSNVE
    • /
    • v.6 no.3
    • /
    • pp.349-355
    • /
    • 1996
  • For a rail traffic noise, a typical source has a length of 200m - 400m so that the noise pollution areas have been located in the transition regions where the sound level drops between 3dB/dd and 6dB/dd. Therefore, in this region, parameters such as a horizontal distance from the track, the geometry of the ground surface, the environmental effect, and the boundary impedance condition play import roles, especially in our nation's situation. In this study, modelling techniques for the finite length of noise source have been investigated in order to evaluate the rail traffic noise level. Then. noise correction value .${\Delta}$SPL for various location in the track region is represented by the non-dimensionalized horizontal and parallel distance from the track. As an application, a high speed train is examined. Beas on the noise data measured for a Eurostar in France, the sound power value per unit length $H_1$is calcuated. It turns out that$H_1$is 109 dB. Overall sound power from the highspeed train to be serviced in our country is expected to 135 dBA.

  • PDF

The Subjective Response for Impulsive Sound - Focusing on the Construction Noise - (충격성 소음에 대한 주관적 반응 - 건설공사장 소음을 중심으로 -)

  • Kim, Deuk-Sung;Chun, Hyung-Jun;Chang, Seo-Il
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.746-755
    • /
    • 2008
  • This research presents a laboratory study on subjective response of impulsive sound caused by construction site (breaker and blasting). The sources are sampled from outdoor noise and their levels range from 40 to 75 dBA at the interval of 5 dBA. The noise unit is based on A-weighted sound exposure level(ASEL; $L_{AE}$). To make equal ASEL of listening level, finite impulse response(FIR) filter is applied to the originally sampled source to include the effect of propagation attenuation. Sixty-three subjects, forty-two males and twenty-one female, between 18 and 29 years of age, participated in the experiment. The evaluation method of jury test adopted a semantic difference method(SDM). In the test results for impulsive noise, the subjective response of blasting noise was higher than that of breaker noise. The result of %HA that has been combined responses of the three methods except for pink-noise was executed by regression analysis and was shown as the following equation.: $%HA=746.53/(1+{\exp} (L_{AE}-93.3))+0.34$.

An Experimental Study on Evaluation of the Sound Insulation for Balcony Window in Apartment Houses (공동주택 발코니 창호의 차음성능 평가에 관한 실험적 연구)

  • 김하근
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1137-1146
    • /
    • 2004
  • In an apartment house In Korea, the balcony is one of the important spaces as a buffer zone for controlling the outdoor environments such as noise, heating & cooling load, humidity etc. Because most areas of building facade in apartment building occupy the area of balcony window the sound Insulation design of It Is very Important to provide the quiet indoor environment. The aim of this research is to evaluate the sound insulation of balcony windows in apartment building by new and revised Korean Industrial Standards. We measured and studied the sound insulations of 18 balcony windows by the type of measuring methods, noise sources, correction of reverberation time in balcony and so on. The results show that the single-number quantities for sound insulation of windows are ranged from 24 dB to 30 dB.