• Title/Summary/Keyword: Outdoor Air Conditioning Energy

Search Result 146, Processing Time 0.026 seconds

Simulation Study on the Performance Evaluation of Light-shelf According to Geometric Shape of Ceiling (천장의 기하학적 형태에 따른 광선반 성능평가 시뮬레이션 연구)

  • Lee, Henagwoo;Kim, Yongseong;Seo, Janghoo;Kim, Duk-Su
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.4
    • /
    • pp.181-192
    • /
    • 2014
  • Light-shelf is one of the most efficient natural lighting systems due to the improved function of the inflow level of the outdoor natural light. However, the existing research on the light shelf limits to the rectangular parallelepiped space, so do not provide sufficient data for various shapes of spaces. Thus, this study aims at deriving proper plan and relationship of the light shelf through its performance assessment depending on the indoor space shapes and utilizing them as basic data of light shelf design. The conclusions are as follows : 1) for 6m space depth, standard intensity of illumination satisfaction depth has shown 8.3%~26.3% improvement through the adjustment of the angle and width when installing light shelf compared to no light shelf installation; 2) $-30^{\circ}$, $-20^{\circ}$ and $-10^{\circ}$ light shelves set by this study play only as a blind regardless of the shape of ceiling on the summer solstice, and it is unsuitable; and 3) this study has derived proper plan of light shelf upon space shapes based on energy reduction and indoor evenness. The study results provide expanded data of the performance assessment of the light shelves according to the different space shapes and light shelf factors, which serves as a basis of the light shelves designing.

A Study on Cooling Performance and Exergy Analysis of Desiccant Cooling System in Various Regeneration Temperature and Outdoor Air Conditions (재생온도와 외기조건 변화에 따른 제습 냉방시스템의 냉방 성능 및 엑서지 해석에 관한 연구)

  • Lee, Jang Il;Hong, Seok Min;Byun, Jae Ki;Choi, Young Don;Lee, Dae Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.5
    • /
    • pp.413-421
    • /
    • 2014
  • Desiccant cooling system is an air conditioning system that uses evaporative cooler to cool air and it can perform cooling by using heat energy only without electrically charged cooler. Thus, it can solve many problems of present cooling system including the destruction of ozone layer due to the use of CFC[chloro fluoro carbon] affiliated refrigerants and increase of peak power during summer season. In this study, cooling performance and exergy analysis was conducted in order to increase efficiency of desiccant cooling system. Especially, using exergy analysis based on the second law of thermodynamics can resolve the issue related to system efficiency in a more fundamental way by analyzing the cause of exergy destruction both in whole system and each component. The purpose of this study is to evaluate COP[coefficient of performance], cooling capacity and exergy performance of desiccant cooling system incorporating a regenerative evaporative cooler in various regeneration temperature and outdoor air conditions.

The Experimental Performance Comparison of a Water Type Glazed and Unglazed PV-Thermal Combined Modules (액체식 PVT 복합모듈의 유형별 성능 비교 분석)

  • Kim, Jin-Hee;Kang, Jun-Gu;Kim, Jun-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.792-797
    • /
    • 2009
  • The excess heat that is generated from PV modules can be removed and converted into useful thermal energy. A photovoltaic-thermal(PVT) module is a combination of photovoltaic module with a solar thermal collector, forming one device that receives solar radiation and produces electricity and heat simultaneously. In general, two types of PVT can be classified: glass-covered PVT module, which produces high-temperature heat but has a slightly lower electrical yield, and uncovered PVT module, which produces relatively lower temperature heat but has a somewhat higher electrical performance. In this paper, the experimental performance of two types of the PVT combined module(water type), glazed(glass-covered) and unglazed, was analyzed. The electrical and thermal performance of the PVT combined modules were measured in outdoor conditions, and the results were compared.

  • PDF

Soft ice-cream maker operating with mixed refrigerant R290/R32 (혼합냉매 (R290/R32) 적용 소프트 아이스크림 제조기 (drop-in 시험))

  • Park, Tae-Gyun;Han, Seong-Pil;Lee, Eung-Ryeol;Kim, Nae-Hyeon;Park, Hyeong-Chae
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.410-413
    • /
    • 2005
  • Drop-in tests were conducted using R290/R32 (31:69) mixture in an ice-cream maker for possible replacement of R-502 and R-404A. Optimum refrigerant charge and TEV opening were obtained through a series of experiments. At the standard outdoor condition ($35^{\circ}C$ DT, $24^{\circ}C$ WT), the time required for initial ice-cream making was 6'22", which was approximately the same as that of R-404A. The electric energy consumed was 660 kJ, which was about 10% higher than that of R-404A. The compressor outlet temperature ($8^{\circ}C$) and pressure (2.52 MPa) were higher than those ($60^{\circ}C$ and 1.48 MPa) of R-404A. The reason could be the usage of the same R-404A compressor although the specific volume of R290/R32 is much larger.

  • PDF

Correlation Analysis for deriving Control Parameters in Vertical Shafts by Design of Experiments (실험계획법에 의한 수직샤프트 제어인자 도출을 위한 상관관계 분석)

  • Han, Hwa-Taik;Shin, Chul-Yong;Baek, Chang-In
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.895-900
    • /
    • 2008
  • It is the objective of the present study to conduct correlation analysis for deriving control parameters in vertical shafts using the results obtain by the design of experiments in the preceding research. The control parameters are categorized into objective parameters, derived parameters, condition parameters, operation parameters, and sensing parameters. The maximum pressure in the shaft should be sufficiently small in order to maintain exhaust hood performance. The pressure variations between floors should also be minimized in order to maintain uniform exhaust performance between floors and to save energy for excessive pressure drop in the shaft. The standard deviation based on -4Pa is proposed as an objective parameter to control pressure in shafts. The correlation equation has been obtained between the standard deviation and the sensing parameters of outdoor temperature and the pressure at the top of the shaft.

  • PDF

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.