Browse > Article
http://dx.doi.org/10.6110/KJACR.2014.26.4.181

Simulation Study on the Performance Evaluation of Light-shelf According to Geometric Shape of Ceiling  

Lee, Henagwoo (The Graduate School of Techno Design, Kookmin University)
Kim, Yongseong (The Graduate School of Techno Design, Kookmin University)
Seo, Janghoo (The Graduate School of Techno Design, Kookmin University)
Kim, Duk-Su (Department of Construction Engineering, Hanbat University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.26, no.4, 2014 , pp. 181-192 More about this Journal
Abstract
Light-shelf is one of the most efficient natural lighting systems due to the improved function of the inflow level of the outdoor natural light. However, the existing research on the light shelf limits to the rectangular parallelepiped space, so do not provide sufficient data for various shapes of spaces. Thus, this study aims at deriving proper plan and relationship of the light shelf through its performance assessment depending on the indoor space shapes and utilizing them as basic data of light shelf design. The conclusions are as follows : 1) for 6m space depth, standard intensity of illumination satisfaction depth has shown 8.3%~26.3% improvement through the adjustment of the angle and width when installing light shelf compared to no light shelf installation; 2) $-30^{\circ}$, $-20^{\circ}$ and $-10^{\circ}$ light shelves set by this study play only as a blind regardless of the shape of ceiling on the summer solstice, and it is unsuitable; and 3) this study has derived proper plan of light shelf upon space shapes based on energy reduction and indoor evenness. The study results provide expanded data of the performance assessment of the light shelves according to the different space shapes and light shelf factors, which serves as a basis of the light shelves designing.
Keywords
Spatial; Physical forme; Light-shelf; Performance evaluation;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Cho, Y. S., 2003, Analysis on Indoor Daylight Performance having Light-shelf system, A Doctoral Dissertation, Graduate School Chungnam National University, Daejeon Korea.
2 Back, S. K. and Le, S. H., 2008, A Study on Lighting Design and Illumination and Luminance of in Advanced type Control Room by the Standard of Ergonomics, Journal of the ergonomics society of Korea, Vol. 27, No. 2, pp. 73-82.   과학기술학회마을   DOI   ScienceOn
3 Chung, Y. G., 2007, Daylighting Performance Evaluation of window Integrated Light Shelf System, Journal of the Korean Institute of Educational Architecture and Environment, Vol. 7, No. 5, pp. 41-46.   과학기술학회마을
4 Cko, S., 2009, The Technical Development Status of Energy Convergence Building, Journal of the Architectural Institute of Korea Planning and Design, Vol. 55, No. 2.
5 Choi, T. J., Lee, S. J., Kim, Y. G., and Kim, H. S., 2001, A Study on the Prediction of Energy Conservation in Apartment Building Utilization by lightself. Proceeding of the SAREK 2011 Summer Annual Conference(II), pp. 971-974.
6 Han, S. P., 2010, A Study on Lighting Control Method for Harmonization of Daylighting and Artificial Lighting, Journal of the Architectural Institute of Korea Planning and Design, Vol. 26, No. 8, pp. 317-324.   과학기술학회마을
7 Kim, D. W. and Park, C. S., 2009, Performance Assessment of Building EnvelopesII:LightShlef, Retro Lux. Proceeding of the KSES 2009 Spring Annual Conference, pp. 83-90.
8 Kim, B. K. and Kim, J. T., 2005, Scale Model Experiment for Daylighting Performance by Lightshelf Types. Journal of the Korean Institute of Educational Architecture and Environment, Vol. 9, pp. 43-50.
9 Shin, H. G., 2003, Daylighting Performance Evaluation of Light Shelf Master's Degree, Graduate School KyungHee University, Seoul, Korea.
10 Lee, H. W. and Lee, S. N., 2011, The Improvement of Uniformity Ratio for Luminous Environment Using Horizontal Lightshelf in an Office Building. J. Korean Soc. lIVING eNVIRON. Sys, Vol. 18, No. 1, pp. 145-152.
11 Lee, H. W., Kim, D. S., and Kim, Y. S., 2013, Simulation Study on the Performance Evaluation of Light-shelf focused on the Depth of Space and the Dimensions and Angles of Light-shelf, Journal of the Architectural Institute of Korea Planning and Design, Vol. 29, No. 3, pp. 335-344.
12 Park, B. C. Kim, Y. S., Jeong, K. Y., Choi, A. S., and Lee, J. H., 2007, An Fundamental Study on the Interactive System for Daylight Response Dimming System and Indoor Shading Systems. Proceeding of Annual Conference of the Architectural Institute of Korea Planning and Design, Vol. 27, No. 1, pp. 989-902.
13 3M, Construction Markets, Product Information.