• 제목/요약/키워드: Outage cost

검색결과 102건 처리시간 0.031초

MIXTURE OF CUMULANTS APPROXIMATION 법에 의한 발전시뮬레이션에 관한 연구 (A STUDY ON THE PROBABILISTIC PRODUCTION COST SIMULATION BY THE MIXTURE OF CUMULANTS APPROXIMATION)

  • 송길영;김용하;차준민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.154-157
    • /
    • 1990
  • This paper describes a new method of calculating expected energy generation and loss of load probability (L.O.L.P) for electric power system operation and expansion planning. The method represents an equivalent load duration curve (E.L.D.C) as a mixture of cumulants approximation (M.O.C.A), which is the general case of mixture of normals approximation (M.O.N.A). By regarding a load distribution as many normal distributions-rather than one normal distribution-and representing each of them in terms of Gram-Charller expansion, we could improve the accuracy of results. We developed an algorithm which automatically determines the number of distribution and demarcation points. In modelling of a supply system, we made subsets of generators according to the number of generator outage: since the calculation of each subset's moment needs to be processed rapidly, we futher developed specific recursive formulae. The method is applied to the test systems and the results are compared with those of cumulant, M.O.N.A and Booth-Baleriaux method. It is verified that the M.O.C.A method is faster and more accurate than any other methods.

  • PDF

A Study on the Fuzzy ELDC of Composite Power System Based on Probabilistic and Fuzzy Set Theories

  • Park, Jaeseok;Kim, Hongsik;Seungpil Moon;Junmin Cha;Park, Daeseok;Roy Billinton
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권3호
    • /
    • pp.95-101
    • /
    • 2002
  • This paper illustrates a new fuzzy effective load model for probabilistic and fuzzy production cost simulation of the load point of the composite power system. A model for reliability evaluation of a transmission system using the fuzzy set theory is proposed for considering the flexibility or ambiguity of capacity limitation and overload of transmission lines, which are subjective matter characteristics. A conventional probabilistic approach was also used to model the uncertainties related to the objective matters for forced outage rates of generators and transmission lines in the new model. The methodology is formulated in order to consider the flexibility or ambiguity of load forecasting as well as capacity limitation and overload of transmission lines. It is expected that the Fuzzy CMELDC (CoMposite power system Effective Load Duration Curve) proposed in this study will provide some solutions to many problems based on nodal and decentralized operation and control of an electric power systems in a competitive environment in the future. The characteristics of this new model are illustrated by some case studies of a very simple test system.

An SCR Thyristor Based Three-Phase Voltage Disturbance Generator

  • Han, Heung-Soo;Jung, Jae-Hun;Nho, Eui-Cheol;Kim, In-Dong;Kim, Heung-Geun;Chun, Tae-Won
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.372-378
    • /
    • 2012
  • This paper deals with a 3-phase voltage disturbance generator for a performance test of custom power devices such as dynamic voltage restorers (DVR), dynamic uninterruptable power supplies (UPS), etc. The operating principle of the proposed circuit is described in each mode of voltage sag, swell, outage, and unbalance. The main components of the proposed disturbance generator are silicone controlled rectifier (SCR) thyristors, variable autotransformers, and transformers. Therefore, the disturbance generator can be implemented with a considerably low cost compared to the conventional pulse width modified (PWM) inverter and converter type generators. Furthermore, it has good features of high reliability with simple structure, high efficiency caused by no PWM switching of the SCR thyristors, and easy control with a wide variation range. To verify the validity of the proposed scheme, simulations and experiments are carried out.

A Techno-Economic Feasibility Analysis on LVDC Distribution System for Rural Electrification in South Korea

  • Afamefuna, David;Chung, Il-Yop;Hur, Don;Kim, Ju-Yong;Cho, Jintae
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1501-1510
    • /
    • 2014
  • Low voltage direct current (LVDC) distribution system is a suitable techno-economic candidate which can create an innovative solution for distribution network development with respect to rural electrification. This research focuses on the use of LVDC distribution system to replace some of KEPCO's existing traditional medium voltage alternating current (MVAC) distribution network for rural electrification in South Korea. Considering the technical and economic risks and benefits involved in such project, a comparative techno-economic analysis on the LVDC and the MVAC distribution networks is conducted using economic assessment method such as the net present value (NPV) on a discounted cash flow (DCF) basis as well as the sensitivity analysis technique. Each would play a role in an economic performance indicator and a measure of uncertainty and risk involved in the project. In this work, a simulation model and a computational tool are concurrently developed and employed to aid the techno-economic analysis, evaluation, and estimation of the various systems efficiency and/or performance.

ARIMA Based Wind Speed Modeling for Wind Farm Reliability Analysis and Cost Estimation

  • Rajeevan, A.K.;Shouri, P.V;Nair, Usha
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권4호
    • /
    • pp.869-877
    • /
    • 2016
  • Necessity has compelled man to improve upon the art of tapping wind energy for power generation; an apt reliever of strain exerted on the non-renewable fossil fuel. The power generation in a Wind Farm (WF) depends on site and wind velocity which varies with time and season which in turn determine wind power modeling. It implies, the development of an accurate wind speed model to predict wind power fluctuations at a particular site is significant. In this paper, Box-Jenkins ARIMA (Auto Regressive Integrated Moving Average) time series model for wind speed is developed for a 99MW wind farm in the southern region of India. Because of the uncertainty in wind power developed, the economic viability and reliability of power generation is significant. Life Cycle Costing (LCC) method is used to determine the economic viability of WF generated power. Reliability models of WF are developed with the help of load curve of the utility grid and Capacity Outage Probability Table (COPT). ARIMA wind speed model is used for developing COPT. The values of annual reliability indices and variations of risk index of the WF with system peak load are calculated. Such reliability models of large WF can be used in generation system planning.

LTE 기반 펨토셀 네트워크에서 간섭 완화를 위한 적응적 전력 제어 기법 (Adaptive Power Control Schemes for Interference Mitigation in LTE Femtocell Networks)

  • 이상준;김승연;이형우;류승완;조충호
    • 한국통신학회논문지
    • /
    • 제37권8A호
    • /
    • pp.648-660
    • /
    • 2012
  • 가중되는 기지국의 트래픽 부하를 줄이면서 실내 음영 지역 문제를 해결하기 위해 저비용, 고성능의 펨토셀(femtocell)에 대한 연구가 활발히 진행되고 있다. 그러나 사무실 빌딩 환경 등 다수의 펨토셀이 설치되는 밀집된 펨토셀 환경에서는 동일 주파수간 간섭 현상으로 인해 전송률이 저하되고 전송품질이 저하되는 등 많은 문제가 발생하게 된다. 본 논문에서는 3GPP LTE 기반 밀집된 펨토셀 환경에서 간섭 완화를 위한 전력 제어 기법을 제안한다. 특히, 기존 매크로셀(eNB)로 부터 서비스 받는 mUE(macro User Equipment)가 펨토셀 주변에 매우 가까이 존재할 경우, 밀집된 펨토셀로부터 mUE에게 영향을 주는 펨토셀의 간섭을 최소화하고 전송 성능을 향상시킬 수 있는 최적의 전력제어 기법을 제안한다. 제안하는 전력 제어 기법은 펨토셀의 밀도와 펨토셀의 전송 성능을 보장하면서 mUE의 성능을 향상시킬 수 있도록 설계하였다. 단말의 Outage Probability와 매크로셀과 펨토셀의 신호대 잡음비(SINR)를 주요 성능 지표로 분석한 결과 본 논문에서 제안하는 전력제어 기법은 간섭 제어를 통해 펨토셀의 성능을 유지하면서 mUE의 성능을 30% 이상 개선할 수 있는 것으로 나타났다.

이중 잡음모델을 채용한 통합 GPS/DR 시스템의 측위성능개선 (Position-Fix Improvement of Integrated GPS and DR System Using Two-Level Noise Model)

  • 남찬웅;임상석
    • 한국항행학회논문지
    • /
    • 제2권2호
    • /
    • pp.75-83
    • /
    • 1998
  • 본 논문에서는 저가이면서 높은 정확도를 갖는 GPS와 DR의 통합시스템 및 이 시스템의 위치 결정에 수반되는 오차문제를 고려한다. 이 통합 GPS/DR 시스템은 실시간 또는 비 실시간으로 고정밀도의 위치 정보를 제공하는 성능을 갖는다. DR 측정치에 영향을 주는 주요 오차 요인을 분석하여 이를 8개의 상태 변수의 모델로 표현하였다. 이들 변수의 상태 방정식을 사용하여 DR신호가 제공되는 매 순간에서 상태 변수값을 추산하기 위한 통합시스템용 비선형 필터를 개발한다, 1Hz의 DR 측정치와 3Hz로 제공되는 GPS 위치 정보를 위치 추산치에 대해 이 통합시스템의 정확도를 평가한다. 시뮬레이션을 통해 GPS신호가 정전되는 기간동안 통합 시스템의 성능을 두 가지 서로 다른 잡음모델에 대해 비교 검토한다. 두 잡음모델 중 하나는 단일잡용을 사용하는 반면에 또 다른 모델은 이중 잡음 모델을 채용한다. 시뮬레이션 결과로부터 이중 잡음 모델을 채용하는 GPS/DR 통합시스템은 단일 잡음 모델을 이용하는 경우에 비하여 측위성능이 우수함을 확인하였다.

  • PDF

저비용 선박간 통신을 위한 전송률 인지 양방향 릴레이 기법 (Rate-Aware Two-Way Relaying for Low-Cost Ship-to-Ship Communications)

  • 왕진수;김선용;정민아;이성로;김윤희
    • 한국통신학회논문지
    • /
    • 제39C권8호
    • /
    • pp.651-659
    • /
    • 2014
  • 본 논문은 선단 내 해상 통신에서 두 통신 선박이 다중 안테나 릴레이 선박의 도움으로 데이터를 교환하는 양방향 릴레이 네트워크를 고려한다. 상기 네트워크에서 두 통신 선박의 정보 전송률이 다를 때 정보 전송 신뢰도를 높이는 전송률 인지 세 단계 아날로그 네트워크 부호화 기법을 제안한다. 제안 기법은 릴레이에서 직교하게 수신된 각 통신 선박의 신호로부터 향상된 품질의 아날로그 네트워크 부호화 신호를 안테나 수신 전력만을 이용하여 생성함으로써 릴레이를 채널 추정 기능 없이 낮은 복잡도로 구현할 수 있도록 한다. 또한, 제안 기법은 두 통신 선박의 서로 다른 전송률을 고려한 전송률-인지 릴레이 전력 할당 방법을 적용하여 비대칭 전송률을 갖는 데이터 교환의 아웃티지 확률을 크게 줄일 수 있음을 모의실험으로 보였다.

확률론적 방법론을 이용한 마이크로그리드(MG)의 에너지 저장장치(ESS) 최소 필요용량 및 투자시점 결정방법 (A Study on the Method to Evaluate Minimum Capacity of Energy Storage System(ESS) for Micro Grid(MG) Design)

  • 이재걸;신정훈;남수철;백승묵
    • 조명전기설비학회논문지
    • /
    • 제24권8호
    • /
    • pp.40-47
    • /
    • 2010
  • Micro Grid(MG)는 새로운 개념의 전력시스템으로 Smart Grid 기술의 일환으로 관심을 받고 있다. 기본적인 MG의 개념은 신/재생에너지를 포함한 분산전원의 도입 및 효율적인 계통운영이지만 여기에는 전력공급의 신뢰성과 경제성이 배제될 수 없는 요소임은 확실하다. MG라는 새로운 계통의 개념을 도입하는데 있어서 기존 전력계통(Utility Grid)과의 간섭, 신뢰도 및 전력품질의 문제들이 해결해야 하는 숙제로 떠오르고 있는데 이에 대한 대안 중 하나가 에너지저장기술이다. 그러나 본 기술은 아직까지는 초기투자비 및 운영유지비가 매우 높은 수준이기 때문에 MG의 설계에 있어서 신뢰도와 경제성을 함께 고려한 Energy Storage System(ESS)의 설치방법이 필요로 된다. 이에 본 논문에서는 공급신뢰도기준을 충족할 수 있는 ESS의 최소필요용량 및 적정투자시점을 결정하는 확률론적 방법을 제안하고 이에 대한 사례연구를 수행하였다.

RF 중계기의 다중 궤환 간섭 신호 제거를 위한 채널 추정 방식 (A Channel Estimation Method for Multipath Feedback Interference Signal Cancellation of RF Repeaters)

  • 이상대;박진;성원진
    • 한국통신학회논문지
    • /
    • 제33권2A호
    • /
    • pp.98-106
    • /
    • 2008
  • 셀룰러 시스템에서의 음영지역 해소 및 전송 용량 증대를 위해 중계기의 역할은 계속적으로 증가하고 있다. 별도의 유선 연결이 요구되는 광 중계기와는 달리, RF 중계기는 설치가 용이하고 위치 제약이 적으며, 비용 측면에서도 광선로 유지 비용 등의 운영 비용이 절감되는 장점을 가지고 있다. 반면 RF 중계기는 송수신 안테나 간 궤환 신호에 의한 간섭이 발생하며, 차폐막으로 감소시키는 간섭 신호 크기가 충분하지 않을 경우 별도의 간섭 제거 방안이 필요하다. 본 논문에서는 두 개의 궤환 경로가 존재하는 경우, 기저대역 신호처리를 활용하는 ICS (Interference Cancellation System) 중계기에서 궤환 간섭 신호 제거를 위한 궤환 채널 추정 방식을 제시하고 그 성능을 평가한다. 제시한 방식은 경로별 채널 추정을 수행하는 기존 방식과 비교하여 MSE (Mean-Squared-Error) 측면에서 10dB 이상의 성능 이득을 갖는다.