• Title/Summary/Keyword: Out-of-Phase

Search Result 4,383, Processing Time 0.035 seconds

THE SCIENTIFIC BASIS OF THE PROCESS OF VEGETABLE JUICE SQUEEZINDG OUT OF LEAFSTALK BIOMASS

  • Proydak, N.I.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.953-956
    • /
    • 1996
  • The main regularities of the process of strain of the leafstalk boimass of the annual and parennial sown grasses (hard phase) with the simulataneous filtration of the vegetable juice (liquid phase) in the working members of the uninterrupted action(screw press) and the periodic action (Briqueting stamp press) were established . The engineering methods of calculation of the basic constructive -technological parameter of the pres equipment of the given types were worked out.

  • PDF

Current-Programmed Control of Three Phase PWM AC-AC Boost Converter

  • Choi, Nam-Sup;Li, Yulong
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.414-416
    • /
    • 2005
  • In this paper, a new scheme of current programmed control for three phase PWM AC-AC converter is presented. By considering only the magnitude components, a similar scheme in the DC-DC converter can be extended to the three phase PWM AC-AC converter. The proposed current programmed control will be well adopted into various converter topologies though three phase PWM AC-AC boost converter is treated as an example. The converter analysis is carried out by applying the vector DQ transformation to obtain physical insight into the converter operation. Finally, the experiment result shows the validity of the proposed scheme.

  • PDF

Improvement of Synchronous Motor Transient Stability by Phase Slipping (상변위에 의한 동기전동기의 과도안정도 개선)

  • Song Yop Hahn
    • 전기의세계
    • /
    • v.21 no.2
    • /
    • pp.20-24
    • /
    • 1972
  • The transient stability of the synchronous motor is generally improved by damper winding or flywheel. However the synchronous motor at full load will be pulled out from normal operation state when the period of power failure exceeds approximately ten cycle per second. This paper studies the method of improving the stability of synchronous motor by equipping the phase slipping switch between the motor and power source. This paper shows the motor does not pull out, which results from the decrease of power angle to about 30 electrical degrees by means of the switch even when the relatively long period of power failure brings the power angle to some 150 electrical degrees.

  • PDF

New Peak-to-Average Power Ratio Reduction Scheme for an OFKM-CDMA System (OFDM-CDMA 시스템에서 새로운 PAPR 감쇄기법)

  • 주양익;이연우;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.7B
    • /
    • pp.1320-1325
    • /
    • 2000
  • A very simple and effective peak power reduction scheme for a downlink OFDM-CDMA system is proposed using the relationship between peak-to-average power ratio (PAPR) and out-of-phase autocorrelation. Since power spectrum and autocorrelation function are Fourier transform pair, the PAPR property of the sequences can be estimated by the out-of-phase autocorrelation function of the spreading sequences. Thus, by scrambling the spread data in the frequency domain, we can reduce the sidelobe energy of autocorrelation, and at last, suppress PAPR in the proposed OFDM-CDMA system.

  • PDF

Application of Phase-Shifting Method in Speckle Interferomtery to Measurement of Micro-Scale Displacement

  • Baek, Tae-Hyun;Kim, Myung-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.3
    • /
    • pp.162-168
    • /
    • 2006
  • Speckle interferometry with phase-shifting method has been applied to measurement of micro-scale displacement through optical signal processing. Four-step phase-shifting method by PZT is used to measure out-of-plane displacement in spot-welded cantilever and results of optical experiments are comparable to those of FEM. Phase-shifting method using Fourier transform by PZT is applied to measurement of in-plane displacement on rectangular steel plate with a circular hole. The results of optical experiment agree well with theoretical calculation. New phase-shifting method in speckle interferometry has been implemented with a quarter wave plate. In-plane displacement of specimen is measured by the new phase-shifting method. Results of optical experiment show that the quarter wave plate can be used for phase-shifting method that is cheap and easy to use in speckle interferometry.

Establishment on Management Plan of Environmental Noise with Noise Map (소음지도를 활용한 환경소음 관리계획 수립)

  • Sun, Hyosung
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.2
    • /
    • pp.123-131
    • /
    • 2011
  • The objective of this study is to prepare the effective management plan of environmental noise with a noise map, and the guideline on the management plan of environmental noise was suggested through the review of existing application examples. The management plan of environmental noise with a noise map includes the practical contents in the stages of subdivision of management areas, establishment of reduction measures, opinion collection, post investigation, and reformulation of management plan. First, the classification of management regions is performed considering the excess degree of noise standard and the facility type in the phase of subdivision of management areas. Second, the optimal management plan is established through the investigation of regional characteristics and various noise reduction measures in the phase of establishment of reduction measures, which includes the examination of noise reduction effects with a noise map and the budget planning with the costing of noise reduction measures. Third, the opinion survey with a local resident and a expert is carried out in order to prove the validity of the management plan in the phase of opinion collection, and the management plan is modified with gathered opinions. Fourth, the post examination plan with noise measurement is performed in order to verify the real effect of noise reduction measures according to the management plan in the phase of post investigation. Finally, the amendment of the management plan as well as the improvement of a noise map is carried out at a regular cycle in the phase of reformulation of management plan.

Design and Implement of the Frequency-Shifting Module for the Improvement of Phase Noise Performance (위상잡음 특성을 개선한 주파수 변환 모듈의 설계 및 제작)

  • 변종대;하태웅;김진수;박준석;임재봉
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.273-278
    • /
    • 2004
  • This paper analyzed the phase noise characteristics of frequency-shifting module by figuring out the relationship between the phase noise components of 1st and 2nd local oscillator composing the frequency-shifting module and those of RF output signals shifted in frequency. Also, frequency-shifting module with the improvement of the phase noise performance was designed and implemented by means that the phase noise components of 1st local oscillator were cancelled in the output signal. Output signal has been affected by only phase noise of 2nd local oscillator, which had excellent phase noise performance than that of the 1st local oscillator.

A New Control Method for a Single-Phase Hybrid Active Power Filter based on a Rotating Reference Frame

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.718-725
    • /
    • 2009
  • To get instantaneous reference data in a single power system with vector space phasors, the instantaneous load current is adopted as a phase and another new signal, which is delayed through filtering by the phase-delay property of a low-pass filter, is used as the secondary phase. Because the two-phases have a different phase, the instantaneous value of the harmonic current can be obtained without a time-delay in calculation. The reference voltage is created by multiplying the coefficient k by the compensation current using the rotating reference frame synchronized with the source-frequency. To verify the validity of the proposed control method, experiments are carried out on a prototype of the single-phase hybrid active power filter system.

Fault Phase Selection Algorithm using Unit Vector of Sequence Voltages for Transmission Line Protection (대칭분 전압 단위 벡터를 이용한 송전선로 보호용 고장상 선택 알고리즘)

  • Lee, Myeong-Su;Lee, Jae-Gyu;Kim, Su-Nam;Yu, Seok-Gu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.9
    • /
    • pp.460-466
    • /
    • 2002
  • A reliable fault phase selection algorithm plays a very important role in transmission line protection, Particularly in Extra High Voltage (EHV) networks. The conventional fault phase selection algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to pick out only fault current since we can not know when a fault occurs and select the fault phase in weak-infeed conditions that dominate zero-sequence current in phase current. The proposed algorithm can select the accurately fault phase using the sum of unit vectors which are calculated by positive-sequence voltage and negative-sequence voltage.

A Study on the Heat Transport Limitations of a PFC(FC-72) Two-Phase Closed Thermosyphon for Cooling Power Semiconductors (전력변환 반도체 냉각용 PFC(FC-72) 밀폐형 2상 열사이폰의 열전달 한계에 관한 연구)

  • 박용주;홍성은;김철주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.9
    • /
    • pp.725-733
    • /
    • 2002
  • In this study, the heat transport limitations of a two-phase closed thermosyphon were investigated. For the test, a two-phase closed thermosyphon ($L_t/: 600 mm,\;L_e:105mm,\;L_a:75mm,\;L_c:420mm,\;D_o:22.2mm,$ container: copper (inner grooved surface), working fluid: PFC ($C_6F_14$) was fabricated with a reservoir that can change the fill charge ratio. The following was imposed as the factors on the heat transport limitations of a two-phase closed thermosyphon. 1) Fill charge ratio of the working fluid. 2) Tilt angle of the longitudinal axis. From tile experimental data, some results were obtained as follows. When the fill charge ratio was relatively small ($\psi$20%), the heat transport limitation occurred about 100W by dry-out limitation. However over 40%, it shelved nearly constant value (500 W) by flooding limitation. The heat transport limitation according to the tilt angle increased smoothly until the tilt angle was $60^{\circ}$,/TEX>, after then decreased slowly.