• Title/Summary/Keyword: Osteoporotic compression fracture

Search Result 69, Processing Time 0.025 seconds

A Biomechanical Study on the Various Factors of Vertebroplasty Using Image Analysis and Finite Element Analysis (의료영상 분석과 유한요소법을 통한 추체 성형술의 다양한 인자들에 대한 생체 역학적 효과 분석)

  • 전봉재;권순영;이창섭;탁계래;이권용;이성재
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.171-182
    • /
    • 2004
  • This study investigates the biomechanical efficacies of vertebroplasty which is used to treat vertebral body fracture with bone cement augmentation for osteoporotic patients using image and finite element analysis. Simulated models were divided into two groups: (a) a vertebral body, (b) a functional spinal unit(FSU). For a vertebral body model, the maximum axial displacement was investigated under axial compression to evaluate the effect of structural integrity. The stiffness of each FE model simulated was normalized by the stiffness of intact model. In the case of FSU model, 3 types of compression fractures were formulated to assess the influence on spinal curvature changes. The FSU models were loaded under compressive pressure to calculate the change of spinal curvature. The results according to the various factors suggest that vertebroplasty has the biomechanical efficacy of the increment of structural reinforcement in a patient who has relatively high level of BMD and a patient with the amount of 15%, PMMA injection of the cancellous bone volume. The spinal curvatures after compression fracture simulation vary from 9$^{\circ}$ to 17$^{\circ}$ of kyphosis compared to that the spinal curvature of normal model was -2.8$^{\circ}$ of lordosis. These spinal curvature changes cause the severe spinal deformity under the same loading. As the degree of compressive fracture increases the spinal deformity also increases. The results indicate that vertebroplasty has the increasing effect of the structural integrity regardless of the amount of PMMA or BMD and the restoration of decreased vertebral body height may be an important factor when the compressive fracture caused the significant height loss of vertebral body.

The Effect of Postural Correction and Subsequent Balloon Inflation in Deformity Correction of Acute Osteoporotic Vertebral Fractures

  • Liu, Hai-Xiao;Xu, Cong;Shang, Ping;Shen, Yue;Xu, Hua-Zi
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.6
    • /
    • pp.337-342
    • /
    • 2014
  • Objective : To determine deformity correction by postural correction and subsequent balloon inflation in acute vertebral compression fractures (OVCFs) and to examine the effect of bone mineral density on deformity correction. Methods : A totol of 50 acute OVCFs received balloon kyphoplasty. Lateral radiographs were taken and analyzed at five different time points : 1) preoperative, 2) after placing the patient in prone hyperextended position, 3) after balloon inflation, 4) after deposition of the cement, and 5) postoperative. All fractures were analyzed for height restoration of anterior (Ha), middle (Hm) and posterior (Hp) vertebra as well as Cobb angle and Kyphotic angle. The bone mineral density (BMD) of lumbar spine was measured by dual-energy X-ray absorptiometry. According to the T-score, the patients were divided into two groups which were osteoporosis group and osteopenia group. Results : Postoperative measurements of Ha, Hm and the Cobb angle demonstrated significant reduction of 4.62 mm, 3.66 mm and $5.34^{\circ}$ compared with the preoperative measurements, respectively (each p<0.05). Postural correction significantly increased Ha by 5.51 mm, Hm by 4.35 mm and improved the Cobb angle by $8.32^{\circ}$ (each p<0.05). Balloon inflation did not demonstrate a significant improvement of Ha, Hm or the Cobb angle compared with baseline prone hyperextended. Postural correction led to greater improvements of Ha, Hm and Cobb angle in osteoporosis group than osteopenia group (each p<0.05). Conclusion : In acute OVCFs, the height restoration was mainly attributed to postural correction rather than deformity correction by balloon inflation. BMD affected deformity correction in the process of postural correction.

Numerous Bilateral Radiographically Dense Branching Opacities after Vertebroplasty with Polymethylmethacrylate (Polymethylmethacrylate를 이용한 경피적 척추성형술 후 흉부 X선에서 관찰된 다수의 양측성, 분지상 선상 음영)

  • Cho, Jun Hyun;Jung, Jong Pil;Eum, Jun-Bum;Seo, Kwang Won;Jegal, Yang Jin;Choi, Seong Hoon;Ahn, Jong Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.2
    • /
    • pp.184-188
    • /
    • 2006
  • Percutaneous vertebroplasty consists of the percutaneous injection of polymethylmethacrylate (PMMA) cement into a collapsed vertebral body in order to obtain pain relief and mechanically strengthen the vertebral body. This procedure is now extensively used in treating osteoporotic vertebral compression fracture. It is an efficient treatment, but it is not free of complications. Most complications after vertebroplasty are associated with PMMA leakage. Pulmonary embolism of PMMA is rare, but this can occur when there is a failure to recognize venous migration of cement early during the procedure. We encountered a case of a patient with asymptomatic pulmonary embolism because of PMMA after percutaneous vertebroplasty. Chest X-ray and CT scanning revealed numerous tubular branching opacities that corresponded to the pulmonary vessels at the segmental and subsegmental levels.

Design and Implementation of A Medical Image Guided System for Vertebroplasty (척추성형술을 위한 의료 영상 시스템의 설계 및 개발)

  • Tack, Gye-Rae;Lee, Sang-Bum;Lee, Sung-Jae
    • The KIPS Transactions:PartB
    • /
    • v.10B no.5
    • /
    • pp.503-508
    • /
    • 2003
  • Since surgical treatment of the spine should overcome neurological compromises, the operative procedures need to be carefully planned and carried out with high degree of precision. Percutaneous vertebroplasty is a surgical procedure that was introduced for the treatment of compression fracture of the vertebrae. This procedure includes puncturing vertebrae and filling with polymethylmethacrylate (PMMA). Recent studies have shown that the procedure could provide structural reinforcement for the osteoporotic vertebrae while being minimally invasive and safe with immediate relief of pain. However, failures of treatment due to excessive PMMA volume injection have been reported as one of complications in vertebroplasty. It is believed that the control of PMMA volume is one of the most critical factors that can reduce the incidence of complications. Therefore, clinical success of vertebroplasty can be dependent on the volume of PMMA injection for a given patient. In this study, the optimal volume of PMMA injection for vertebroplasty was predicted based on the image analysis of a given patient.

Surgical Treatment of Osteoporotic Vertebral Compression Fractures at Thoraco-Lumbar Levels: Only Pedicle Screw Constructs with Polymethylmethacrylate Augmentation (흉요추부 골다공증성 척추 압박 골절의 수술적 치료: 골시멘트 보강술을 이용한 척추경 나사 고정)

  • Jun, Deuk Soo;Baik, Jong-Min;Park, Ji Hyeon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.327-335
    • /
    • 2019
  • Purpose: To investigate the radiological efficacy of polymethylmethacrylate (PMMA) augmentation of pedicle screw operation in osteoporotic vertebral compression fractures (OVCF) patients. Materials and Methods: Twenty OVCF patients, who underwent only posterior fusion using pedicle screws with PMMA augmentation, were included in the study. The mean follow-up period was 15.6 months. The demographic data, bone mineral density (BMD), fusion segments, number of pedicle screws, and amount of PMMA were reviewed as medical records. To analyze the radiological outcomes, the radiologic parameters were measured as the time serial follow-up (preoperation, immediately postoperation, postoperation 6 weeks, 3, 6 months, and 1 year follow-up). Results: A total of 20 patients were examined (16 females [80.0%]; mean age, 69.1±8.9 years). The average BMD was -2.5±0.9 g/cm2. The average cement volume per vertebral body was 6.3 ml. The mean preoperative Cobb angle of focal kyphosis was 32.7°±7.0° and was improved significantly to 8.7°±6.9° postoperatively (p<0.001), with maintenance of the correction at the serial follow-up, postoperatively. The Cobb angle of instrumented kyphosis, wedge angle, and sagittal index showed similar patterns. In addition, the anterior part of fractured vertebral body height averaged 11.0±5.0 mm and was improved to 18.5±5.7 mm postoperatively (p=0.006), with maintenance of the improvement at the 3-month, 6-month, and 1-year follow-up. Conclusion: The reinforcement of pedicle screws using PMMA augmentation may be a feasible surgical technique for OVCF. Moreover, it appears to be appropriate for improving the focal thoracolumbar/lumbar kyphosis and is maintained well after surgery.

Bone Mineral Density of Normal Korean Adult Using QCT (적량적 전산화단층촬영을 이용한 한국인의 골밀도)

  • Lee Jong Deok
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.18 no.6
    • /
    • pp.1918-1926
    • /
    • 2004
  • Osteoporosis is defined as a progressive systemic skeletal disorder characterized by low bone mineral density, microarchitectual deteriorations of bone and susceptibility to fracture. numerous methods have been used for quantitative assessment of the skeleton in osteoporosis. QCT has been shown to measure changes in trabecular mineral content in the spine with great sensitivity and precision. To provide the normal reference values and changes of lumbar spinal bone mineral density in korean adult spinal bone mineral density was evaluated in 451 women (229 premenopausal and 222 postmenopausal women) and 206 men, aged 20 to 74 years old in Wonkwang hospital from 2000 to 2004, which was carried out by using QCT. women with oophorectomy, vertebral compression fracture, any history of endocrine disease and use of drugs that alter bone metabolism were excluded. According to the WHO definition, a patient is osteoporotic based on a bone mineral density(BMD) measurement that is 2.5 standard deviations (SDs) below typical peak bone mass of young healthy white women. This measurement of standard deviation from peak mass is called the T score. BMD values of normal women in their 20-24 years, 25-29 years, 30-34 years, 35-39 years, 40-44 years, 45-49 years, 50-54 years, 55-59 years, 60-64 years, 65-69 years, over 70 years were 168.95㎎/㏄ K₂PHO₄, 155.41㎎/㏄ K₂PHO₄, 166.87㎎/㏄ K₂PHO₄, 160.67㎎/㏄ K₂PHO₄, 154.06㎎/㏄ K₂PHO₄, 132.04㎎/㏄ K₂PHO₄, 114.05㎎/㏄ K₂PHO₄, 91.78㎎/㏄ K₂PHO₄, 78.61 ㎎/㏄ K₂PHO₄, 61.35㎎/㏄ K₂PHO₄, 50.53㎎/㏄ K₂PHO₄ Mean bone density of normal women was 115.77K₂PHO₄ K₂PHO₄. BMD values of normal men in their 20-24 years, 25-29 years, 30-34 years, 35-39 years, 40-44 years, 45-49 years, 50-54 years, 55-59 years, 60-64 years, 65-69 years, over 70 years were 171.46㎎/㏄ K₂PHO₄, 162.19㎎/㏄ K₂PHO₄, 155.62㎎/㏄ K₂PHO₄, 147.28㎎/㏄ K₂PHO₄, 137.56㎎/㏄ K₂PHO₄, 137.56㎎/㏄ K₂PHO₄, 101.25㎎/㏄ K₂PHO₄, 109.00㎎/㏄ K₂PHO₄, 103.32㎎/㏄ K₂PHO₄, 91.53㎎/㏄ K₂PHO₄, 88.35㎎/㏄ K₂PHO₄ Mean density of normal men was 115.77㎎/㏄ K₂PHO₄. Peak bone density of women and men was in the age group of 20-24 years and 168.95㎎/㏄ K₂PHO₄, 171.46㎎/㏄ K₂PHO₄, respectively. Bone loss was increased with aging and was accelerated in postmenopausal women than that of premenopausal women. The total loss of BMD for women and men was 70.09% and 48.47%, respectively. Postmenopausal women(mean BMD : 85.83㎎/㏄ K₂PHO₄) had significantly lower BMD than premenopausal women(meand BMD : 144.80㎎/㏄ K₂PHO₄)(p<0.001). The annual loss of BMD of women and men was 2.702㎎/㏄ K₂PHO₄ and 1.795㎎/㏄ K₂PHO₄, respectively. This study provided the BMD reference data for normal korean adult. further studies on BMD in healthy adult and comparison with published data are needed.

Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations (척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2014
  • Purpose: With the aging of the population, the attack rate of osteoporotic vertebral compression fracture is in the increasing trend, and percutaneous vertebroplasty (PVP) is the most commonly performed standardized treatment. Although there is a research report of the excellence of usefulness of the SPECT/CT examination in terns of the exact diagnosis before and after the procedure, the bone cement material used in the procedure influences the image quality by forming an artifact in the CT image. Therefore, the objective of the research lies on evaluating the effect the bone cement gives to a SPECT/CT image. Materials and Methods: The images were acquired by inserting a model cement to each cylinder, after setting the background (3.6 kBq/mL), hot cylinder (29.6 kBq/mL) and cold cylinder (water) to the NEMA-1994 phantom. It was reconstructed with Astonish (Iterative: 4 Subset: 16), and non attenuation correction (NAC), attenuation correction (AC+SC-) and attenuation and scatter correction (AC+SC+) were used for the CT correction method. The mean count by each correction method and the count change ratio by the existence of the cement material were compared and the contrast recovery coefficient (CRC) was obtained. Additionally, the bone/soft tissue ratio (B/S ratio) was obtained after measuring the mean count of the 4 places including the soft tissue(spine erector muscle) after dividing the vertebral body into fracture region, normal region and cement by selecting the 20 patients those have performed PVP from the 107 patients diagnosed of compression fracture. Results: The mean count by the existence of a cement material showed the rate of increase of 12.4%, 6.5%, 1.5% at the hot cylinder of the phantom by NAC, AC+SC- and AC+SC+ when cement existed, 75.2%, 85.4%, 102.9% at the cold cylinder, 13.6%, 18.2%, 9.1% at the background, 33.1%, 41.4%, 63.5% at the fracture region of the clinical image, 53.1%, 61.6%, 67.7% at the normal region and 10.0%, 4.7%, 3.6% at the soft tissue. Meanwhile, a relative count reduction could be verified at the cement adjacent part at the inside of the cylinder, and the phantom image on the lesion and the count increase ratio of the clinical image showed a contrary phase. CRC implying the contrast ratio and B/S ratio was improved in the order of NAC, AC+SC-, AC+SC+, and was constant without a big change in the cold cylinder of the phantom. AC+SC- for the quantitative count, and AC+SC+ for the contrast ratio was analyzed to be the highest. Conclusion: It is considered to be useful in a clinical diagnosis if the application of AC+SC+ that improves the contrast ratio is combined, as it increases the noise count of the soft tissue and the scatter region as well along with the effect of the bone cement in contrast to the fact that the use of AC+SC- in the spine SPECT/CT examination of a PVP performed patient drastically increases the image count and enables a high density of image of the lesion(fracture).

  • PDF

In Vivo and In Vitro Studies of the Steady State Free Precession-Diffusion-Weighted MR Imagings on Low b-value : Validation and Application to Bone Marrow Pathology

  • Byun, Woo-Mok
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.119-128
    • /
    • 2007
  • Purpose : The purpose of this study was a phantom study to measure the diffusion properties of water molecules by steady-state free precession diffusion-weighted imaging (SSFP- DWI) with a low b-value and to determine if this sequence might be useful for application to the evaluation of bone marrow pathology. Materials and methods : 1. The phantom study: A phantom study using two diffusion weighted sequences for the evaluation of the diffusion coefficient was performed. Three water-containing cylinders at different temperatures were designed: phantom A was $3^{\circ}C$, B was $23^{\circ}C$ and C was $63^{\circ}C$. Both SSFP and echo planar imaging (EPI) sequences (b-value: $1000s/mm^2$) were performed for comparison of the diffusion properties. The Signal to noise ratios (SNR) and apparent diffusion coefficient (ADC) values of the three phantoms using each diffusion-weighted sequence were assessed. 2. The Clinical study: SSFP-DWI was performed in 28 patients [sacral insufficiency fractures (10), osteoporotic lumbar compression fractures (10), malignant compression fractures (8)]. To measure the ADC maps, a diffusion-weighted single shot stimulated echo-acquisition mode sequence ($650s/mm^2$) was obtained using the same 1.5-T MR imager Results : For the phantom study, the signal intensity on the SSFP as well as the classic EPI-based DWI was decreased as the temperature increased in phantom A to C. The ADC values of the phantoms on EPI-DWI were $0.13{\times}10^{-3}mm^2/s$ in phantom A, $0.22{\times}10^{-3}mm^2/s$ in B and $0.37{\times}10^{-3}mm^2/s$. in C. The SSFP can be regarded as a DWI sequence in view of the series of signal decreases. Conclusion : Bone marrow pathologies with different diffusion coefficients were evaluated by SSFP-DWI. All benign fractures were hypointense compared to the adjacent normal bone marrow where as the malignant fractures were hyperintense compared to the adjacent normal bone marrow.

  • PDF

Characteristics of Blood Mixed Cement in Percutaneous Vertebroplasty (경피적 척추 성형술에서 혈액 혼합 시멘트의 특성)

  • Seo, Jin-Hyeok;Woo, Young-Ha;Jeong, Ju-Seon;Kim, Do-Hun;Kim, Ok-Gul;Lee, Sang-Wook;Park, Chan-Ho
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.435-439
    • /
    • 2019
  • Purpose: This study evaluated the efficacy of blood mixed cement for osteoporotic vertebral compression fractures in reducing the complications of percutaneous vertebroplasty using conventional cement. Materials and Methods: This study was performed retrospectively in 80 patients, from January 2016 to January 2017. Porous cement was formed by mixing 2, 4, and 6 ml of blood with 20 g of cement used previously. A tube with a diameter and length of 2.8 mm and 215 mm, respectively, was used and the polymerization temperature, setting time, and optimal passing-time were measured and compared with those using only conventional cement. Radiologically, the results were evaluated and compared. Results: The polymerization temperature was 70.3℃, 55.3℃, 52.7℃, and 45.5℃ in the conventional cement (R), 2 ml (B2), 4 ml (B4), and 6 ml (B6), respectively, and the corresponding setting time decreased from 960 seconds (R) to 558 seconds (B2), 533 seconds (B4), and 500 seconds (B6). The optimal passing-time was 45 seconds (B2), 60 seconds (B4), and 78 seconds (B6) at 73 seconds (R), respectively and as the amount of blood increased, it was similar to the cement passing-time. The radiological results showed that the height restoration rates and the vertebral subsidence rates similar among the groups. Two cases of adjacent vertebral compression fractures in the R group and one in the B2 and B4 groups were encountered, and the leakage rate of the cement was approximately two times higher than that in the conventional cement group. Conclusion: In conventional percutaneous vertebroplasty, the procedure of using autologous blood with cement decreased the polymerization temperature, reduced the setting time, and the incidence of cement leakage was low. These properties may contribute to more favorable mechanical properties that can reduce the complications compared to conventional cements alone.