4도체 가공선로에서 복도체 스페이서를 이용한 진동저감 대책 연구 (A Study on Measures Against Subspan Oscillation using Twin Spacers in 4 Bundle Overhead Lines)

  • 이형권;한형주
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.323-327
    • /
    • 2009
  • The oscillation is very dangerous in bundled transmission lines, besides 4 bundle transmission lines are very weak for subspan oscillations. In some cases, subspan oscillations are continuously occurred in the same subspan. In order to develop the control method of the above subspan oscillation, this paper suggests a method of applying twin spacers to the subspans. We have carried out some tests to analyze the oscillation phenomena after installing twin spacers on 4 bundle overhead lines, and we got a good effect for controling subspan oscillations by installing twin spacers.

345kV 가공선로에서 진동발생 다발 소경간에 대한 진동저감 대책(II) (A study on measures against subspan oscillation by twin spacers in 345kV overhead transmission lines(II))

  • 이형권;한형주;박창기;최웅규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.200-202
    • /
    • 2008
  • The oscillation is very dangerous in bundled transmission lines, especially 345kV 4 bundle transmission lines are very weak for subspan oscillations. In some cases, subspan oscillations are continuously occurred in the same subspan. In order to develop the control method of the above subspan oscillation, this paper suggests a method of applying twin spacers to the subspans. We have carried out some tests to analyze the oscillation phenomena after installing twin spacers on 34sky real lines, and we got a good effect for controling subspan oscillations.

  • PDF

단면 변화가 있는 기주의 열음향진동에 관한 연구 (A Study on the Thermoacoustic Oscillation of an Air Column with Variable Cross Section Area)

  • 권영필;홍하표
    • 대한설비공학회지:설비저널
    • /
    • 제17권2호
    • /
    • pp.131-139
    • /
    • 1988
  • The thermoacoustic oscillation induced in an air column with variable cross section area is investigated theoretically and experimentally. The onset condition of the oscillation is derived by equating the acoustic power production to the power dissipation. The power production at the heater is predicted by using the efficiency factor obtained by heat transfer analysis for a single wire in a uniform cross flow and considering the interference between heater wires. The power dissipation is estimated by measuring the attenuating coefficient from the pressure decay curve. The theoretical prediction to the onset condition of the oscillation is confirmed experimentally. The effect of the variation of the column cross section area on the onset condition is presented.

  • PDF

진동하는 평판에서 발생하는 비정상 후류형상연구 (Study on Unsteady Wake Behavior Behind Oscillating Flat Plates)

  • 안준성;한철희;조진수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.950-955
    • /
    • 2003
  • The fluid propulsion mechanism of two oscillating flat plates is studied numerically using a discrete vortex method. Presently, the flat plates are assumed to be rigid. To analyze the closely coupled aerodynamic interference between the flat plates, a core addition scheme and a vortex core model are combined together. A calculated wake pattern for a flat plate in heaving oscillation motion is compared with the flow visualization. The effect of wake shapes on the aerodynamic characteristics of the flat plate in pitching oscillation is investigated. The velocity profiles behind the flat plates in pitching oscillations are plotted to investigate the possible thrust generation mechanism.

  • PDF

Numerical investigations on the effect of mean incident wind on flutter onset of bridge deck sections

  • Keerthana, M.;Harikrishna, P.
    • Structural Engineering and Mechanics
    • /
    • 제82권4호
    • /
    • pp.517-542
    • /
    • 2022
  • The effect of mean angle of wind attack on the flutter critical wind speed of two generic bridge deck cross-sections, viz, one closed box type streamlined section (deck-1) and closed box trapezoidal bluff type section with extended flanges/overhangs (deck-2) type of section have been studied using Computational Fluid Dynamics (CFD) based forced vibration simulation method. Owing to the importance of the effect of the amplitude of forcing oscillation on the flutter onset, its effect on the flutter derivatives and flutter onset have been studied, especially at non-zero mean angles of wind attack. The flutter derivatives obtained have been used to evaluate flutter critical wind speeds and flutter index of the deck sections at non-zero mean angles of wind attack studied and the same have been validated with those based on experimental results reported in literature. The value of amplitude of forcing oscillation in torsional degree of freedom for CFD based simulations is suggested to be in the range of 0.5° to 2°, especially for bluff bridge deck sections. Early onset of flutter from numerical simulations, thereby conservative estimate of occurrence of instability has been observed from numerical simulations in case of bluff bridge deck section. The study aids in gaining confidence and the extent of applicability of CFD during early stages of bridge design, especially towards carrying out studies on mean incident wind effects.

A New DPWM Method to Suppress the Low Frequency Oscillation of the Neutral-Point Voltage for NPC Three-Level Inverters

  • Lyu, Jianguo;Hu, Wenbin;Wu, Fuyun;Yao, Kai;Wu, Junji
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1207-1216
    • /
    • 2015
  • In order to suppress the low frequency oscillation of the neutral-point voltage for three-level inverters, this paper proposes a new discontinuous pulse width modulation (DPWM) control method. The conventional sinusoidal pulse width modulation (SPWM) control has no effect on balancing the neutral-point voltage. Based on the basic control principle of DPWM, the relationship between the reference space voltage vector and the neutral-point current is analyzed. The proposed method suppresses the low frequency oscillation of the neutral-point voltage by keeping the switches of a certain phase no switching in one carrier cycle. So the operating time of the positive and negative small vectors is equal. Comparing with the conventional SPWM control method, the proposed DPWM control method suppresses the low frequency oscillation of the neutral-point voltage, decreases the output waveform harmonics, and increases both the output waveform quality and the system efficiency. An experiment has been realized by a neutral-point clamped (NPC) three-level inverter prototype based on STM32F407-CPLD. The experimental results verify the correctness of the theoretical analysis and the effectiveness of the proposed DPWM method.

VCO의 MSL길이가 발진특성에 미치는 영향 (Effects of the length the MSL on the oscillation characteristic of the VCO)

  • 이동희;정진휘
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.721-724
    • /
    • 2001
  • In this paper, we present the effect the length the MSL(Microstrip Line) on the oscillation characteristic of the fabricated VCOs(Voltage Controlled Oscillator) designed and analyzed by RF circuit simulator Serenade(ANSOFT Co.) and fabricated by screen printing method on the alumina substrate. We have fabricated VCOs with 3 different MSL length and each MSL length of the VCO is 140mi1, 280mil and 560mi1. The oscillation frequency of each sample(VCO) was tuned to UHF band(750MHz∼900MHz) varying the capacitance. The experimental result shows the phase noise -82∼-97[dBc/Hz] at a 50 [kHz] offset frequency, the pushing figure 94∼318[kHz] at 3${\pm}$0.15[V] and the harmonics 13∼21 [dBc] between MSL length 140mi1s and 560mi1. The frequency and output variation width are 779∼898[MHz], -36∼-33[dBm] at MSL length 140mi1; 818∼836[MHz], -27.19∼-27.06[dBm] at 280mi1;751.54∼751.198[MHz],-33.44∼ -33.31[dBm] at 560mi1. we examined 3 VCOs oscillation characteristic difference through comparison with phase noise, oscillation power and frequency by control voltage change, harmonics and pushing figure for each sample.

  • PDF

상대속도를 고려한 CMP 공정에서의 연마제거율 모델 (MRR model for the CMP Process Considering Relative Velocity)

  • 김기현;오수익;전병희
    • 소성∙가공
    • /
    • 제13권3호
    • /
    • pp.225-229
    • /
    • 2004
  • Chemical Mechanical Polishing(CMP) process becomes one of the most important semiconductor processes. But the basic mechanism of CMP still does not established. Slurry fluid dynamics that there is a slurry film between a wafer and a pad and contact mechanics that a wafer and a pad contact directly are the two main studies for CMP. This paper based on the latter one, especially on the abrasion wear model. Material Removal Rate(MRR) is calculated using the trajectory length of every point on a wafer during the process time. Both the rotational velocity of a wafer and a pad and the wafer oscillation velocity which has omitted in other studies are considered. For the purpose of the verification of our simulation, we used the experimental results of S.H.Li et al. The simulation results show that the tendency of the calculated MRR using the relative velocity is very similar to the experimental results and that the oscillation effect on MRR at a real CMP condition is lower than 1.5%, which is higher than the relative velocity effect of wafer, and that the velocity factor. not the velocity itself, should be taken into consideration in the CMP wear model.

다기계통에서의 SVC와 TCSC특성 해석 (SVC & TCSC Effects Power System in Multi-Machine)

  • 설용태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.658-660
    • /
    • 1996
  • This paper prescribe the effects of SVC & TCSC in multi-machine power system. EMTP models of two FACTS controllers are proposed to analysis the basic characteristics of SVC & TCSC and the control signal of TCR is determined by rms value which was measured in system. The oscillation model of generator is proposed to analysis the damping effect and the most effective location of TCSC in multi-machine power system is identified by the residues associated with the natural oscillation modes. The 3 generator-9 bus model system is used to demonstrate the applicability of the proposed model.

  • PDF

Stochastic Analysis of Self-sustained Oscillation Loop for a Resonant Accelerometer

  • Hyun, Chul;Lee, Jang-Gyu;Kang, Tae-Sam;Sung, Sang-Kyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.574-578
    • /
    • 2004
  • In this paper, a nonlinear feedback system is analyzed for a surface micromachined resonant accelerometer. For this, a brief illustration of the plant dynamics is given. In the analysis, the periodic signal in the nonlinear feedback loop is obtained by the limit cycle point, which is best approximated via the describing function method. Considering the characteristic feature of plant dynamics, a simple phase shifted relay with finite slope is designed for the nonlinearity implementation. With a describing function for random plus sinusoidal input, we analyzed the effect of a white Gaussian noise on oscillation frequency. Finally, simulation and experimental result is given.