• 제목/요약/키워드: Oscillating pressure

검색결과 165건 처리시간 0.023초

주기적인 유동과 압력의 변화를 수반하는 맥동관의 열전달계수와 전단계수 (Heat Transfer Coefficient and Shear Factor Subjected to Both Oscillating Flow and Oscillating Pressure in Pulse Tubes)

  • 정은수
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.220-227
    • /
    • 2007
  • Heat transfer and momentum transfer under conditions of both oscillating flow and oscillating pressure within pulse tubes show very different behavior from those for steady state conditions. The analytic solutions of axial velocity and temperature of the gas within pulse tubes were obtained by assuming that the variations in pressure and temperature were purely sinusoidal and small. The shear stress and the heat flux at the tube wall obtained from the solutions are expressed in terms of the cross-sectional averaged velocity, the difference between mean temperature and instantaneous cross-sectional averaged temperature and the difference between mean pressure and instantaneous pressure. It is shown that the complex shear factor, which has been applied to momentum transfer of incompressible oscillating flow, and the complex Nusselt number, which has been applied to either heat transfer with oscillating pressure only or heat transfer of incompressible oscillating flow, could also be used for momentum transfer and heat transfer subjected to both oscillating flow and oscillating pressure, respectively.

맥동압력조건에서 재생기를 통한 왕복유동의 압력강하 특성에 대한 연구 (Investigation on the pressure drop characteristics of oscillating flow through regenerators under pulsating pressure conditions)

  • 최성열;남관우;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.51-57
    • /
    • 2003
  • This paper proposes a new oscillating flow model of the pressure drop through the regenerator under pulsating pressure. In this oscillating flow model. pressure drop is expressed by the amplitude and the phase angle with respect to the inlet mass flow rate. In order to generalize the oscillating flow model. non-dimensional parameters, which are Reynolds number, Valensi number, gas domain length ratio, oscillating flow friction factor and phase angle of pressure drop, are derived from the capillary tube model of the regenerator. Correlations for the oscillating flow friction factor and the phase angle are obtained from the experiments for the twill-square screen regenerators under various operating frequencies and inlet mass flow rates. The oscillating friction factor is a function of the Reynolds number alone and the phase angle of pressure drop is a function of the Valensi number and the gas domain length ratio. Experiment is also performed to examine the effect of the weave style of screen. Experimental data demonstrate the superiority of the oscillating flow model over the previous steady flow model.

맥동압력조건에서 재생기를 통한 왕복유동의 압력강하 특성에 대한 연구 (Investigation on the pressure drop characteristics of oscillating flow through regenerator under pulsating pressure conditions)

  • 최성열;남관우;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.21-27
    • /
    • 2003
  • This paper proposes a new model of the pressure drop for more accurate description of oscillating flow through regenerator under pulsating pressure conditions in contrast to an existing model based on steady flow. For the universal uses of the oscillating flow model, non-dimensional parameters, which consist of Reynolds number, Valensi number gas domain length ratio, oscillating flow friction factor and phase angle of pressure drop, are derived from the capillary tube model of the regenerator. Two correlation equations of the model are obtained from the experiments for the twill square screen regenerators under various operating frequencies and inlet mass flow rates. The oscillating friction factor is a function of only the Reynolds number and the phase angle of pressure drop is a function of the Valensi number and the gas domain length ratio. Experiment is also performed to examine the effects of the shape of screens.

  • PDF

PORE WATER PRESSURE IN SAND BED UNDER OSCILLATING WATER PRESSURE

  • HoWoongShon
    • 지구물리
    • /
    • 제6권2호
    • /
    • pp.57-69
    • /
    • 2003
  • In this paper the theoretical method to analyse the pore water pressures in the bed under the oscillating water pressure is developed. In the former researches the validity of the theoretical treatment for the one-dimensional problem has been verified. However, the one-dimensional treatment is not sufficient to obtain the precise information concerning the many practical problems. From this point of view, in this study, we derive the fundamental equations for the general three-dimensional sand layer under the oscillating water pressure. The validity of this theoretical method is verified by experiments for the two-dimensional problems.

  • PDF

Dynamic Behavior of Sand Bed under Oscillating Water Pressure

  • HoWoongShon
    • 지구물리
    • /
    • 제6권2호
    • /
    • pp.49-56
    • /
    • 2003
  • Under the attack of storm waves, there are many destructions of coastal structures in the forms of sinking and sliding. There types of destructions will be in close relation to the dynamic behavior of sand bed around the structures. Form this point of view, in this pear, we investigate the characteristics of the pore water pressure and effective stresses in the highly saturated sand bed under oscillating water pressure theoretically. The results indicate that the oscillating water pressure induce the notable drop of strength of and bed around the structure under certain condition.

  • PDF

The Study on Pressure Oscillation and Heat Transfer Characteristics of Oscillating Capillary Tube Heat Pipe

  • Kim, Jong-Soo;Bui, Ngoc-Hung;Jung, Hyun-Seok;Lee, Wook-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제17권10호
    • /
    • pp.1533-1542
    • /
    • 2003
  • In the present study, the characteristics of pressure oscillation and heat transfer performance in an oscillating capillary tube heat pipe were experimentally investigated with respect to the heat flux, the charging ratio of working fluid, and the inclination angle to the horizontal orientation. The experimental results showed that the frequency of pressure oscillation was between 0.1 Hz and 1.5 Hz at the charging ratio of 40 vol.%. The saturation pressure of working fluid in the oscillating capillary tube heat pipe increased as the heat flux was increased. Also, as the charging ratio of working fluid was increased, the amplitude of pressure oscillation increased. When the pressure waves were symmetric sinusoidal waves at the charging ratios of 40 vol.% and 60 vol.%, the heat transfer performance was improved. At the charging ratios of 20 vol.% and 80 vol.%, the waveforms of pressure oscillation were more complicated, and the heat transfer performance reduced. At the charging ratio of 40. vol.%, the heat transfer performance of the OCHP was at the best when the inclination angle was 90$^{\circ}$ the pressure wave was a sinusoidal waveform, the pressure difference was at the least, the oscillation amplitude was at the least, and the frequency of pressure oscillation was the highest.

맥동관 내부의 열전달에 관한 실험적 연구 (Experimental study on the transfer in pulse tube)

  • 김민규;남관우;정상권;장호일;정은수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권1호
    • /
    • pp.45-50
    • /
    • 2000
  • The present study has been conducted to observe the heat transfer under pulsating pressure and oscillating flow. The experimental apparatus was fabricated to measure the gas temperature, the wall temperature. the pressure and the instantaneous heat flux inside the pulse tube. The measured gas temperature and heat flux must be calibarated to compensate their finite time constant in the oscillating flow conditious. The experiment was performed from 1 Hz to 5 Hz. The phase difference between the instantaneous heat flux and the gas-wall temperature difference was clearly observed. The experimental heat fluxes were compared to the theroretical correlations such as Complex Nusselt Number Model(CNNM) and Variable Coefficient Model(CVM). The heat flux predisted by CNNM was always greater than that of VCM. The experiment confirmed the valisity of the VCM for the instantaneous heat flux under the pulsating pressure and oscillating flow in the warm end of the pulse tube.

  • PDF

진동하는 고 받음각 날개주위의 비정상 아음속 유동해석 (Analysis of Unsteady Subsonic Flow Around a High Angle of Attack of the Oscillating Airfoil)

  • 문지수;김재수
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.434-440
    • /
    • 2011
  • Oscillating airfoil haw been challenged for the dynamic stalls of airfoil am wind turbines at high angle of attach. Especially, the pressure oscillation has a huge effect on noise generation, structure damage, aerodynamic performance am safety, because the flow has strong unsteadiness at high angle of attack. In this paper, the unsteady aerodynamics coefficients were analyzed for the oscillating airfoil at high angle of attack around two dimensional NACA0012 airfoil. The two dimensional unsteady compressible Navier-Stokes equation with a LES turbulent model was calculated by OHOC (Optimized High-Order Compact) scheme. The flow conditions are Mach number of 0.2 and Reynolds number of $1.2{\times}10^4$. The lift, drag, pressure distribution, etc. are analyzed according to the pitching oscillation. Unsteady velocity field, periodic vortex shedding, the unsteady pressure distribution, and the acoustic fields are analyzed. The effects of these unsteady characteristics in the aerodynamic coefficients are analyzed.

  • PDF

회전 진동하는 원형실린더 주위 유동의 폐쇄효과 연구 (BLOCKAGE EFFECT ON FLOWS AROUND A ROTATIONALLY OSCILLATING CIRCULAR CYLINDER)

  • 강승희;권오준
    • 한국전산유체공학회지
    • /
    • 제13권4호
    • /
    • pp.33-38
    • /
    • 2008
  • For study on the unsteady blockage effect, flows around a rotationally oscillating circular cylinder with relatively low forcing frequency in closed test-section wind tunnels have been numerically investigated by solving compressible Navier-Stokes equations. The numerical scheme is based on a node-based finite-volume method with the Roe's flux-difference splitting and an implicit time-integration method coupled with dual time-step sub-iteration. The computed results of the oscillating cylinder in the test section showed that the fluctuations of lift and drag are augmented by the blockage effects. The drag further increases because of low base pressure. The pressure on the test section wall shows the harmonics having the oscillating and the shedding frequencies contained in the blockage effect.

원통형 진동수주 파력발전장치에 의한 파 에너지 흡수 (Wave Energy Absorption by a Circular Cylinder Oscillating Water Column Device)

  • 조일형
    • 한국해안해양공학회지
    • /
    • 제14권1호
    • /
    • pp.8-18
    • /
    • 2002
  • 본 논문에서는 밑이 뚫린 원통형 진동수주 파력발전장치에 의한 파 에너지 흡수효율을 살펴보았다. 경계치 문제는 공기실내의 변동압력이 없을 때 입사파에 의한 산란문제와 공기실 내부의 변동압력에 의한 방사문제로 나누어진다. 공기실 내에서 공기 흐름에 대한 연속방정식을 적용하여 변동압력을 구하였다. 이로부터 진동수주 파력발전장치가 흡수한 시간평균 마력과 에너지 취득 폭을 구하였다. 수치계산에서는 원통형 공기실의 반지름과 잠긴 깊이 그리고 입사파의 주파수를 바꿔가면서 공기실 내부의 유량 변화와 에너지 취득 폭을 살펴보았다. 수학적으로 구한 최적의 터빈 상수를 대입하며 구한 에너지 취득 폭의 최대값은 원통형 공기실의 공진 모드 중에서 첫 번째 공진 모드인 Helmholtz모드에서 나타난다. 따라서 효율적인 파력발전장치를 제작하기 위해서는 설치될 해역의 파의 주파수와 공기실의 고유주파수가 일치되도록 공기실의 형상을 설계하여야 한다.