• Title/Summary/Keyword: Orthopaedic Device

Search Result 44, Processing Time 0.029 seconds

Foreign Body Reaction after Implantation of a Device for Intervertebral Assisted Motion

  • Seo, Jun-Yeong;Ha, Kee-Yong;Kim, Young-Hoon;Ahn, Joo-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.6
    • /
    • pp.647-649
    • /
    • 2016
  • The device for intervertebral assisted motion (DIAM) is a dynamic implant that consists of a silicone bumper enveloped by a polyethylene terephthalate (PET) fiber sack. Silicone and PET were used because of their biological inertness, but repetitive motion of the spine can cause wear on the implant nonetheless. The purpose of this study is to report a case of foreign body reaction (FBR) against a DIAM. A 72-year-old female patient presented with lower back pain and both legs radiating pain. She had undergone DIAM implantation at L4-5 for spinal stenosis 5 years previously. The intervertebral disc space of L4-5, where the DIAM was inserted, had collapsed and degenerative scoliosis had developed due to left-side collapse. MRI showed L3-4 thecal sac compression and left L4-5 foraminal stenosis. The patient underwent removal of the DIAM and instrumented fusion from L3 to L5. During surgery, fluid and granulation tissue were evident around the DIAM. Histopathology showed scattered wear debris from the DIAM causing chronic inflammation due to the resulting FBR. A FBR due to wear debris of a DIAM can induce a hypersensitivity reaction and bone resorption around the implant, causing it to loosen.

Use of custom glenoid components for reverse total shoulder arthroplasty

  • Punyawat Apiwatanakul;Prashant Meshram;Andrew B. Harris;Joel Bervell;Piotr Lukasiewicz;Ridge Maxson;Matthew J. Best;Edward G. McFarland
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.343-350
    • /
    • 2023
  • Background: Our purpose was to evaluate a custom reverse total shoulder arthroplasty glenoid baseplate for severe glenoid deficiency, emphasizing the challenges with this approach, including short-term clinical and radiographic outcomes and complications. Methods: This was a single-institution, retrospective series of 29 patients between January 2017 and December 2022 for whom a custom glenoid component was created for extensive glenoid bone loss. Patients were evaluated preoperatively and at intervals for up to 5 years. All received preoperative physical examinations, plain radiographs, and computed tomography (CT). Intra- and postoperative complications are reported. Results: Of 29 patients, delays resulted in only undergoing surgery, and in three of those, the implant did not match the glenoid. For those three, the time from CT scan to implantation averaged 7.6 months (range, 6.1-10.7 months), compared with 5.5 months (range, 2-8.6 months) for those whose implants fit. In patients with at least 2-year follow-up (n=9), no failures occurred. Significant improvements were observed in all patient-reported outcome measures in those nine patients (American Shoulder and Elbow Score, P<0.01; Simple Shoulder Test, P=0.02; Single Assessment Numeric Evaluation, P<0.01; Western Ontario Osteoarthritis of the Shoulder Index, P<0.01). Range of motion improved for forward flexion and abduction (P=0.03 for both) and internal rotation up the back (P=0.02). Pain and satisfaction also improved (P<0.01 for both). Conclusions: Prolonged time (>6 months) from CT scan to device implantation resulted in bone loss that rendered the implants unusable. Satisfactory short-term radiographic and clinical follow-up can be achieved with a well-fitting device. Level of evidence: III.

Arthroscopic Stabilization for Displaced Lateral Clavicular Fractures: Can It Restore Anatomy?

  • Khan, Prince Shanavas;Yoo, Yon-Sik;Kim, Byung-Su;Lee, Seong-Jin;Ha, Jong Mun
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.143-148
    • /
    • 2016
  • Background: The purpose of our study was to evaluate the accuracy of reduction based on postoperative computed tomography (CT) images after arthroscopic stabilization using tightrope system for unstable distal clavicle fracture. Methods: Twelve patients with distal clavicle fracture combined with coracoclavicular (CC) ligament injury (type II, V) who received arthroscopically assisted fixation using a flip button device were evaluated for accuracy of reduction using 3-dimensional postoperative CT scan by measuring the degree of distal clavicular angulation and clavicular shortening. Results: Immediate postoperative plain radiograph confirmed restoration of the CC distance (CCD) in 10 patients. At final follow-up, the CCD remained reduced anatomically on plain radiographs in these patients. All patients showed excessive posterior angulation and shortening compared to the opposite side. The average Constant score recovered to 94.8 at final follow-up. Conclusions: Indirect reduction and arthroscopic subacromial approach with flip button fixation of unstable distal clavicle fractures demonstrated favorable clinical results despite unavoidable posterior angulation of distal clavicle and shortening the total length of clavicle.

Arthroscopic Meniscal Repair with Bioabsorbable Devices (생체 흡수성 기구를 이용한 반월상 연골 봉합술)

  • Kim Jong Soon;Shin Kyoo Seog;Lee Dong Hwa;Sok Jin Ho;Park Sang Hwan;Heo Jeong Kuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.150-155
    • /
    • 2002
  • Purpose : The purpose of this study was to evaluate the clinical results of meniscal repair using the bioabsorbable devices. Materials and Methods : From 1998, 21 meniscal repairs were underwent using the bioabsorbable devices and followed more than 1 year. The Meniscus $Arrow^{\circledR}$(Bionx) and the Meniscal $Fastener^{\circledR}$(Mitek) had been applied. The indication for meniscus refixation was an unstable longitudinal tear in the posterior horn of the medial or lateral meniscus. Concurrent ACL reconstruction with meniscal repair was performed on 9 knees. The clinical result was evaluated using Lysholm knee score. Result : The average Lysholm knee scores for all patients improved from 56 preoperatively, to 89 postoperatively. The type of the device were not significantly related to clinical outcome or Lysholm knee score. But the concurrent ACL reconstruction group and the patients treated within 8 weeks had better clinical result than the others. Conclusion : The all-inside meniscal repair technique using bioabsorbable devices can be considered to be an useful method in the well selected patients and concurrent ACL reconstruction surgery.

  • PDF

The Modified $Brostr{\ddot{o}}m$ Procedure for Chronic Lateral Ankle Instability (만성 족관절 외측 불안정성에 대한 $Brostr{\ddot{o}}m$ 변형 술식)

  • Song, Ha-Heon;Shim, Dae-Moo;Lee, Byoung-Chang;Kim, Dong-Churl;Cho, Yong-Woo;Yang, Jung-Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.1
    • /
    • pp.81-85
    • /
    • 2004
  • Purpose: The purpose of this study is to evaluate the surgical results of modified $Brostr{\ddot{o}}m$ procedure for chronic lateral ankle instability and to assess whether or not associated injuries may affect postoperative satisfaction. Materials and Methods: Twenty- four patients with chronic lateral ankle instability were evaluated retrospectively from August 1998 to March 2002. Average age was 29.3 years. All patients were performed pre & postoperative ankle anteroposterior and lateral view, stress anterior drawer and varus test using Telos device, MRI and intraoperative arthroscopic evaluations before ligament reconstruction. Results: Of the 24 cases, 23 cases was improved more than average 12 points on AOFAS scales. On modified scales of Hamilton, 3 excellent, 20 good, 1 fair results. On stress view, average 2.2 mm difference was improved on anterior drawer test and average 1.7 degree on varus test. Associated injuries were 8 osteochondral defects, 4 anterior impingements, 2 loose bodies, 2 os subfibulare, 2 os submalleolare and 2 partial ruptures of peroneus brevis. 8 cases with no associated injuries rated excellent or good. Conclusion: The modified $Brostr{\ddot{o}}m$ procedure is believed to be an effective and successful method for chronic lateral ankle instability that didn't respond to conservative treatment. Because associated injuries in chronic lateral ankle instability may affect postoperative satisfaction, appropriate detection and treatment may need for postoperative satisfaction.

  • PDF

Proximal Humaral Fractures (근위 상완골 골절)

  • Kim, Jeong-Woo
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2007.11a
    • /
    • pp.189-195
    • /
    • 2007
  • $\cdot$ Difficult & Challenging Fracture $\cdot$ Most Treated Nonoperative $\cdot$ ORIF in Young Patients with Unstable Fractures $\cdot$ Fixed Angles Device is Promising $\cdot$ Prosthetic Arthroplasty in Elderly $\cdot$ Loss of Motion Very Common

  • PDF

Reconstruction of Anterior Cruciate Ligament With Bone-Patellar tendon-Bone Allograft (동종 슬개건을 이용한 전방십자인대 재건술)

  • Chun, Churl Hong;Lee, Byoung Chang;Kim, Young Jin;Yang, Hwan Duk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.102-108
    • /
    • 1999
  • Purpose : The purpose of this study was to evaluate the clinical results of bone-patellar tendon-bone(B-PTB) allograft for ACL reconstruction without mechanical tensioning device. Material and Method : Forty-six knees in 43 patients were reviewed and evaluated with subjective evaluation, objective evaluation, Telos stress arthrometer and modified Feagin Scoring System. The average age at the time of operation was 27 years(range, 18-42) and the average follow up period was 41 months(range, 22-79). Authors reconstructed ACL using B-PTB allograft which was prepared by rehydration preoperatively without tensioning by mechanical tensioning device. The tension for allograft was obtained by full flexion and extension intraoperatively. All operation were performed arthroscopically by two-tunnel method to avoid the mismatching of allograft tendon length. Result : The modified Feagin Scoring System revealed 39 cases(84.7%) with excellent or good results and 7 cases(15.3%) with fair or poor results. The mean follow-up Lysholm Knee Score was 84. Telos arthrometer revealed 41 cases had an injured-to-uninjured difference of 5 mm or less(mean 2.3mm). The range of motion of knee was nearly normal and there was no extension lag in any cases at last follow up. Conclusion : Clinical results using B-PTB allograft showed less morbidity than B-PTB autograft. The intraoperative tensioning method by full flexion and extension without mechanical tensioning device was not bad. Therefore, B-PTB allograft is a good substitute material in reconstruction of the ACL.

  • PDF

Modified Essex-Lopresti Reduction for the Displaced Intra-articular Calcaneal Fractures (전위된 관절 내 종골 골절에 대한 Essex-Lopresti 변형 정복술)

  • Kwak, Kyoung-Duck;Cho, Hyoun-Oh;Lim, Dae-Hwan;Ahn, Sang-Min;Jang, Jae-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.1
    • /
    • pp.109-114
    • /
    • 2003
  • Purpose: The purpose of this study is to evaluate the effectiveness and indications of the modified Essex-Lopresti reduction in calcaneal fractures. Materials and Methods: We reviewed retrospectively 41 cases of displaced intraarticular calcaneal fractures. The fracture was reduced with Essex-Lopresti technique with modification in compression of the lateral wall with the specially designed compression device instead of the operator's hands. We evaluated the results of treatment by AOFAS scale and the radiographic parameters including the Bohler's angle, calcaneal width, calcaneofibular distance and the congruency of the posterior facet. Results: Boler's angle was restored from 11 to 29.6 degrees on average, heel width was reduced to 112% of contralateral value, the calcaneofibular gap was restored up to 87.9% of contralateral side, and the articular surface of the posterior facet was restored less than 2 mm of step off and less than 2 mm of gap. AOFAS scale averaged 87 points. The quality of reduction was best in Sander's type II fractures. Small sized fragments in type III fractures could not be reduced. The results were better when the reductions were performed within 24 hours of injury. Conclusion: The modified Essex-Lopresti reduction was less invasive, easy to perform, and the results of treatment were similar to those of open reduction; it seemed to be a reasonable alternative for the selected intraarticular calcaneal fractures.

  • PDF

A Novel Fluoroscopic View for Positioning the AO Clavicle Hook Plate Decreases Its Associated in situ Complications

  • Hyun, Yoon-Suk;Kim, Gab-Lae;Choi, Sang-Min;Shin, Woo-Jin;Seo, Dong-Yeon
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.25-32
    • /
    • 2016
  • Background: The goal of this study was to evaluate whether a modified fluoroscopic technique for positioning a hook plate affected the clinical results of treating Neer type II distal clavicle fractures and Rockwood type V acromioclavicular (AC) joint separations with this device. Methods: The study was a retrospective consecutive case series with data analysis. Sixty-four patients with a Neer type II distal clavicle fracture or a Rockwood type V AC joint injury treated between March 2009 and June 2013 were divided into 2 groups: traditional fluoroscopic technique (traditional view, 31 patients) or modified fluoroscopic technique ('hook' view, 33 patients). A visual analogue scale (VAS) score, the modified University of California-Los Angeles (UCLA) shoulder scale score, and radiographic osteolysis were the main outcome measures. Results: The traditional group included a significantly larger number of patients with acromial osteolysis than the hook view group: 23 patients (74.2%) vs. 11 patients (33.3%), respectively (p=0.01). Before plate removal, the hook group reported less pain and higher UCLA shoulder scale scores than the traditional group: average VAS score, 1.55 vs. 2.26, respectively; average UCLA score, 30.88 vs. 27.06, respectively. However, there was no significant difference after plate removal. Conclusions: The hook view allows more accurate bending of the hook plate around the contour of the acromion, resulting in decreased osteolysis, decreased pain, and better function with the plate in situ.

Radiographic Measurement of Ankle Lateral Stability in Normal Korean Adults (정상 한국 성인에서 발목관절 외측 안정성의 방사선학적 계측)

  • Shon, Hyun-Chul;Kim, Yong-Min;Kim, Dong-Soo;Choi, Eui-Sung;Park, Kyoung-Jin;Cho, Byung-Ki;Park, Ji-Kang;Hong, Kyung-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • Purpose: Anterior drawer and varus stress test are commonly used for radiologic evaluation of chronic lateral ankle instability. However, there are controversies regarding the method of measurement and the normal value. This study was performed to investigate radiologic normal values in normal Korean adults and to analyze differences by age and gender. Materials and Methods: Sixty Korean adults were recruited and divided in three groups (20 in their twenties, 20 in their thirties, 20 in their forties). There were 10 males and 10 females in each group. The selection criteria were no history of ankle injury and no evidence of instability on physical examination. Radiologic measurement of varus talar tilt and anterior talar translation were performed through anterior and varus stress radiographs using Telos device (150N force). The measurement was repeated twice by three researchers, and intraobserver reproducibility and interobserver reliability were analyzed. The average talar tilt and anterior talar translation were obtained. Results: Talar tilt and anterior talar translation on ankle stress radiographs had good intraobserver reproducibility and interobserver reliability. Talar tilt was average $3.7^{\circ}$ and $5.1^{\circ}$ in male and female of twenties of age, $3.9^{\circ}$ and $4.8^{\circ}$ in their thirties, $3.4^{\circ}$ and $4.5^{\circ}$ in their forties. Anterior talar translation was average 3.5 mm and 4.2 mm in their twenties, 4.1 mm and 3.8 mm in their thirties, 3.6 mm and 4.1 mm in their forties. There was no significant difference in talar tilt and anterior talar translation by age. However, there was significant difference in talar tilt by gender. Conclusion: Normal range of talar tilt angle in Korean adults was below $8.3^{\circ}$, and normal range of anterior talar translation was below 7.6 mm. It seems to be able to serve as a good reference for radiologic evaluation and for treatment of chronic lateral ankle instability.