• Title/Summary/Keyword: Orthodontic wire

Search Result 143, Processing Time 0.031 seconds

Evaluation of friction of ceramic brackets in various bracket-wire combinations (브라켓 각도 변화에 따른 세라믹 브라켓의 마찰력 측정)

  • Cha, Jung-Yul;Kim, Kyung-Suk;Kim, Dong-Choon;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.125-135
    • /
    • 2006
  • The purpose of this study was to measure and compare the level of frictional resistance generated from three currently used ceramic brackets; 1, Crystaline $V^{(R)}$, Tomy International Inc., Tokyo, Japan; 2, $Clarity^{(R)}$, 3M Unitek, Monrovia, CA, USA; 3, $Inspire^{(R)}$, Ormco, Orange, CA, USA; with composite resin brackets, Spirit, Ormco, Orange, CA, USA; and conventional stainless steel brackets, Kosaka, Tomy International Inc., Tokyo, Japan used as controls. In this experiment, the resistance to sliding was studied as a function of four angulations $(0^{\circ},\;5^{\circ},\;10^{\circ}\;and\;15^{\circ})$ using 2 different orthodontic wire alloys: stainless steel (stainless steel, SDS Ormco, Orange, CA, USA), and beta-titanium (TMA, SDS Ormco, Orange, CA, USA). After mounting the 22 mil brackets to the fixture and $.019{\times}.025$ wires ligated with elastic ligatures, the arch wires were slid through the brackets at 5mm/min in the dry state at $34^{\circ}C$. Silica-insert ceramic brackets generated a significantly lower frictional force than did other ceramic brackets, similar to that of stainless steel brackets. Beta-titanium archwires had higher frictional resistance than did stainless steel, and all the brackets showed higher static and kinetic frictional force as the angulation increased. When the angulation exceeded $5^{\circ}$, the active configuration emerged and frictional force quickly increased by 2.5 to 4.5-fold. The order of frictional force of the different wire-bracket couples transposed as the angle increased. The silica-insert ceramic bracket is a valuable alternative to conventional stainless steel brackets for patients with esthetic demands.

TENSILE STRENGTHS OF PRE-LIGATURED BUTTON WITH SEVERAL TYPES OF CONTAMINATION IN DIRECT BONDING PROCEDURE WHICH CAN HAPPEN DURING THE SURGICAL EXPOSURE OF UNERUPTED TEETH (치아의 견인을 위한 버튼 접착시 오염이 인장강동에 미치는 영향)

  • Kim, Seong-Oh;Choi, Byung-Jai;Lee, Jae-Ho;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.400-420
    • /
    • 1998
  • We already know that it is very difficult to obtain an "isolated field" for direct bonding during the surgical exposure of unerupted teeth. The aim of this in-vitro study is to simulate the clinical situation of forced eruption and to evaluate the tensile strengths of preligatured button with several types of contamination which can happen during the surgical exposure of unerupted teeth. Four orthodontic direct bonding systems were used. ($Ortho-One^{TM}$, $Rely-a-Bond^{(R)}$, $Ortho-Two^{TM}$, Phase $II^{(R)}$) Each material was divided into four groups(n=20) : Group 1. (Control, no contamination), Group 2. (Rinse etching agent with saline instead of water), Group 3. (Blood contamination of etched surface for 30 seconds), Group 4. (Blood contamination of primed surface for 30 seconds) 320 bovine anterior permanent teeth were divided into the above mentioned 16 groups. Enamel surface was flattened and ground under water coolant. Pre-ligatured buttons were prepared to the same form. (Cut 0.25 ligature wire 10 cm in length. Twist the ligature wire 30 times clockwise. Mark the wire 15mm and 35mm points from button. Make a loop sticking two points together and twist the loop 6 times counterclockwise.) The bonded specimens were stored at $37^{\circ}C$ saline solution for 3 days. Then the tensile strength of each sample was measured with Instron universal testing machine, crosshead speed of 0.5mm/min. The following results were obtained: 1. As compared to control groups (Group 1) of each material, Rely-a-Bond had a significantly lower mean tensile strengths than other material. (p<0.01) 2. In Group 2. of Ortho-One and Rely-a-Bond, the mean tensile strengths decreased about 7.7% and 11.1%, respectively with statistical significances. (p<0.05) 3. In Group 2. of Ortho-Two and Phase II, the mean tensile strengths did not decrease. 4. In Group 3. of Ortho-One, Rely-a-Bond, Ortho-Two, and Phase II, the mean tensile strengths decreased about 60.8%, 56.1%, 60.2%, and 46.0%, respectively with statistical significances. (p<0.01) 5. In Group 4. of Ortho-One and Rely-a-Bond, the mean tensile strengths did not decrease. 6. In Group 4. of Ortho-Two and Phase II, the mean tensile strengths were decreased about 20.95% and 22.28%, respectively with statistical significances. (p<0.01) There were formations of a hump shaped mass from bonding resin under blood contamination which disturbed direct bonding procedure. According to Reynolds, the proper bond strength for clinical manipulation should be at least 45N or about 4.5Kg.F. According to these results, it can be concluded that Ortho-One could be used during surgical exposure of unerupted teeth. In any case, blood contamination of the etched surface should be avoided, but the blood contamination of primed surface of Ortho-One may not decrease bond strength. Just 'blowing-out' is enough to remove blood from primed surface of Ortho-One. You can verify the clean surface of the primer of Ortho-One after blowing out the blood contamination.

  • PDF

Identification of bacteria from the peri-implant sulcus of orthodontic mini-implants using 16S rDNA clone library (16S rDNA 클론 library 제작 및 핵산염기서열 결정을 통한 교정용 미니임플랜트 주위 열구의 세균 동정)

  • Lim, Sung-Hoon;Kim, Kwang-Won;Yoo, So-Young;Kook, Joong-Ki;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.251-262
    • /
    • 2006
  • Objective: The purpose of this study was to compare the bacterial flora at the peri-implant sulcus of the orthodontic mini-implant placed in the alveolar mucosa with the bacterial flora at the adjacent healthy gingival sulcus. Methods: Two plaque samples from 7 patients were collected by inserting paper points into the sulcus between the mini-implant and ligature wire connected to the mini-implant head and inflamed alveolar mucosa, and from the gingival sulcus of a healthy tooth adjacent to the mini-implant. Results: Using 16S rDNA clone library, the 24 kinds of bacteria including Haemophilus aphrophilus, Sphingomonas species, Capnocytophaga species, Prevotella melaninogenica, Lachnospiraceae species, Porphyromonas species, Neisseria flava were identified only from the sulcus around the mini-implant. These bacteria constituted only 9.2% of total clones, and the bacteria identified from both the sulcus around mini-implants and the gingival sulcus constituted 80.4% of total clones. Of these bacteria, clones of Prevotella species, Atopobium rimae, Veillonella species, Streptococcus intermedius/constellatus, Streptococcus salivarius were more frequently isolated from the peri-implant sulcus. Conclusion: This study suggests that a broad epidemiological study is needed to find causative bacteria which induce inflammation from the peri-implant sulcus.

A STUDY ON THE EXPRESSION OF VASCULAR ENDOTHELIAL GROWTH FACTOR IN TENS10N SIDE OF RAT MOLAR PERIODONTAL LIGAMENT FOLLOWING EXPERIMENTAL TOOTH MOVEMENT (백서 구치의 실험적 치아이동시 견인측 치근막에서 혈관성장인자의 발현에 관한 연구)

  • Lim, Yong-Kyu;Shin, Choon-Shik;Lee, Dong-Ryul
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.121-136
    • /
    • 2001
  • This study was performed to analyse the expression of VEGF and it's receptor(VEGFR) in the tension side of the periodontal ligament following orthodontic tooth movement. Upper first molars of Sprague-Dawley rats were moved medially using closed coil spring for 1, 2, 24 hours and 3, 7, 14 days. H&E staining, immunohistochemical staining and in situ hybridization methods were used to analyse the change of the expression of VEGF and VEGFR. The results from this study were as follows : 1. Following tensional force, periodontal ligament showed elongation of fibers, compression and congestion of vessels and regional hemorrhage. These tissue changes were recovered within 3 days of force application. New bone formation was seen after 3 days of force application and continued for the remaining experimental periods. 2. Following tensional force, VEGF and VEGF mRNA expression was increased in the periodontal ligament cells, osteoblasts and cementoblasts. This change was followed by increased vasculature in the periodontal ligament. 3. After 3 days of tensional force, VEGF and VEGF mRNA expression was confined mainly to the osteopaths and the periodontal ligament cells adjacent to the alveolar bone. After 2 weeks of force application, VEGF and VEGF mRNA expression was reduced to the level of control sample. 4. VEGFRs(Flt-1, Flk-1) showed similar expression pattern and it's expression was mainly seen in the endothelial cells and osteoblasts. Following tensional force VEGFR expression was increased in the endothelial cells and osteoblasts. In conclusion, in the tension side of the penodontal ligament, ligament cells, osteoblast and cementoblast showed increased expression of VEGF & VEGF mRNA. It preceded the increase of vasculature and new bone formation. The increased expression of VEGF mRNA in cementoblast may induce periodontal vessels, which distribute mainly the bone side half of periodontal ligament, grow in the direction of tensional force. Increased expression of VEGFR & VEGFR mRNA not only in endothelial cell but in osteoblast, osteocyte and periodontal cells showed VEGF acts not only in paracrine manner but in autocrine one.

  • PDF

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

Comparison of biofilm on titanium and zirconia surfaces: in vivo study (생체 내 티타늄과 지르코니아 표면에서 형성시킨 치면세균막의 비교)

  • Lim, Kyu-Taek;Lee, Ji-Hyun;Lim, Il-Gu;Park, So-Hyun;Lim, Hyun-Phil;Kim, Ok-Su
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.245-251
    • /
    • 2013
  • Purpose: This study was conducted to compare in vivo biofilm formation on titanium surface and zirconia surface. Materials and methods: For biofilm formation on titanium and zirconia in oral cavity, after producing oral appliances using acrylic resin and orthodontic wire tailored to 9 subjects, we made titanium and zirconia specimens ($6mm{\times}6mm{\times}2mm$), fixed them on oral appliances and maintained them in oral cavity of test subjects for 24 and 72 hours. Test subjects who have equipped two pairs of specimens maintained oral hygiene not by using toothpaste but only by tooth brushing. After 24 and 72 hours, we removed and observed specimens through scanning electron microscopy (SEM). Results: Biofilm formation showed large deviation depending on individuals. For formation comparison between titanium and zirconia for 24 hours, zirconia showed less biofilm formation than titanium. Biofilm formation showed large deviation depending on individuals. As for formation comparison between zirconia and titanium, the degree of biofilm formation in zirconia was less than it was in titanium after a lapse of 24 hours. The result of biofilm formation in 72 hours trial show that zirconia has an inclination to formate less biofilm than it was in titanium. Conclusion: Based on the above results, we can conclude that early biofilm formation in oral cavity was influenced by difference of abutment materials.

RELATIONSHIP OF THE BACTERIA INHIBITING PLAQUE FORMATION AND THE NUMBER OF ORAL BACTERIA (치태형성 억제세균과 구강내 세균수와의 관계)

  • Yang, Kyu-Ho;Chung, Hyun-Ju;Oh, Jong-Suk
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.459-465
    • /
    • 1999
  • The inhibition degree of the isolated bacteria on plaque formation of Streptococcus mutans, and the effect of these bacterial genus on the concentration of total bacteria in saliva were assessed with the following. The effectiveness of the isolated bacteria on the inhibition of plaque formation was assessed culturing Streptococcus mutans in the beaker with orthodontic wires. The mean weight of plaque produced on a wire was 152mg in the culture of Streptococcus mutans only, whereas being reduced to 4mg, 78mg, or 72mg in the combined culture of Streptococcus mutans and Enterococcus durans, Lactobacillus acidophilus, or Streptococcus oralis. The colony forming units (CFU) of Streptococcus mutans were $3.6{\times}10^8$ per ml in the culture of Streptococcus mutans, only, wheras being $1.4{\times}10^6,\;5.6{\times}10^6,\;or\;3.8{\times}10^6$ per ml in the combined culture of Streptococcus mutans and Enterococcus durans, Lactobacillus acidophilus, or Streptococcus oralis. When saliva from children was inoculated on brain heart infusion agar, the colony forming units of bacteria were $4.8{\times}10^6\;to\;1.3{\times}10^9$ per ml of saliva. The concentration of Enterococcus, Lactobacillus, or Streptococcus inhibiting Streptococcus mutans in saliva was not proportioned to that of total bacteria replicated on brain heart infusion agar. These results indicate that the isolated bacteria inhibited the replication of Streptococcus mutans, resulting into inhibiting the formation of plaque, but the concentration of Enterococcus, Lactobacillus, or Streptococcus inhibiting Streptococcus mutans, in saliva might not affect the total bacterial concentration of saliva.

  • PDF

TREATMENT OF MAXILLARY FIRST MOLARS WITH ERUPTION FAILURES (맹출장애를 가진 상악 제1대구치의 치료)

  • Kwon, Soon-Yeon;Kim, Hyun-Jung;Kim, Yeung-Jin;Nam, Sun-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.2
    • /
    • pp.281-287
    • /
    • 2009
  • An eruption failure can be observed for child and adolescent periods when the primary dentition is changed to the permanent dentition through the mixed dentition frequently. The eruption failure can lead to miss erupting times of the tooth, then it will cause a lot of problems including root resorption, esthetic problem, transposition of adjacent tooth, malocclusoin and etc. Especially, the maxillary first molar is importantly concerned with occlusion and growth and is an essential tooth for development and maintenance of occlusion. So, it is a momentous part of more proper occlusal management to find these abnormal cases at the early stage and solve the problems. The sorts of eruption failures of the maxillary first molars can be divided into delayed eruption, impaction and the primary retention and the secondary retention. When physical obstacles cause impaction, first of all they must be removed then we can treat the impaction with observation after removal, surgical exposure or orthodontic traction. If the source of impaction is an ectopic eruption, the treatment can be a brasswire, a pendulum appliance, a space maintainer or space regainer after the extraction of the second deciduous tooth and etc. These cases are made a diagnosis of eruption failures of the maxillary first molars in mixed dentition period and have good prognosises after my treatments. So I reported them.

  • PDF

A FRONTAL CEPHALOMETRIC STUDY ON THE REFERENCE LINES TO ASSESS THE CRANIOMAXILLOFACIAL ASYMMETRY (안면 비대칭의 평가를 위한 기준에 관한 정모 두부 방사선 계측학적 연구)

  • Paek, Sun-Ho;Ahn, Byoung-Keun;Kim, Sun-Hae;Sohn, Hong Bum;Han, Ho Jin;Kang, Soo-Man
    • The korean journal of orthodontics
    • /
    • v.23 no.1 s.40
    • /
    • pp.1-15
    • /
    • 1993
  • This study was undertaken to investigate the midline having the least difference between the right and left structures among the lines that had been used in the study of the craniomaxillofacial asymmetry. The sample of this study consisted of twenty six Korean girls(average 18.9 years old) having normal facial appearance and occlusion. On the frontal cephalometric films of the sample, we divided the whole craniomaxillofacial area into four portions, i.e., cranial, upper facial, lower facial, and dental portion. So, we have found the midlines having the least difference in the whole craniomaxillofacial area itself, and in the each divided four portions, furtherly in the other portions from aimed portion. The findings were as follow: 1. In the whole craniomaxillofacial area, the connecting line between crista galli and anterior nasal spine and the perpendicular bisecting line between right and left foramen rotundums were suitable for the midline. 2. In the cranial portion, established all six lines were suitable for midlines. In the other portions, the perpendicular bisection line between both condylion, the line passing the contact point between right and left mandibular central insisiors among the perpendicular lines between right and left mandibular central incisial tips were suitable midlines fer evaluating the asymmetry of cranial portion. 3. In the upper facial portion, the perpendicular bisecting line between right and left zygions was the most suitable midline. In the other portions, the line between the crista galli and the most superior point of the odontoid process, the perpendicular bisecting line between right and left gonions, the perpendicular bisecting line between right and left condylions, and perpendicular bisecting line between right and left foramens rotundum were suitable midlines for evaluating the asymmetry of the upper facial portion 4. In the dental portion, the perpendicular bisecting lines between right and left buccal cusps of both maxillary first molars and between right and left mandibular first molars were suitable midlines. In the other portions, the perpendicular bisecting line between right and left landmarks crossing the lesser wing of the sphenoid bone and orbit, the perpendicular bisecting line between right and left mental foramens, and the connecting line between crista galli and prosthion were suitable midlines for evaluating the asymmetry of dental portion. 5. In the lower facial portion, the perpendicular bisecting lines between right and left condylions and between right and left gonions were suitable midlines. In the other portions, the line between the crista galli and anterior nasal spine, the perpendicular bisecting line between right and left foramen rotundums, and the perpendicular bisecting lines between right and left buccal cusps of both mandibular first molars and between right and left maxillary first molars were suitable midlines for evaluating the asymmetry of the lower facial portion.

  • PDF

Effect of Presurgical Nasoalveolar Molding in Unilateral Cleft Lip and Palate Infants (편측성 구순구개열 신생아에 대한 술전비치조정형장치의 효과)

  • Kim, Jin-Sun;Kim, Young-Jin;Nam, Soon-Hyeun;Kim, Hyun-Jung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.3
    • /
    • pp.209-215
    • /
    • 2013
  • Cleft lip and palate, the most common craniofacial anomalies, are severe congenital defects that have an incidence of 0.28 to 3.74 per 1000 live births. Although there has been great improvement in the field of cleft surgery, surgical approach cannot be the single solution to resolve the various problems encountered in patients with cleft lip and palate. The concept of presurgical infant orthopedics (PSIO) for gradual closure of the cleft gap and simplified surgical performance was first introduced by McNeil in 1950. Recently, there are many attempts not only to approximate the alveolar segments but also to reshape the nasal cartilage. Three infants with unilateral cleft lip and palate were referred from the department of Plastic Surgery for presurgical nasoalveolar molding (PNAM). Maxillary appliances using resin with orthodontic wire were fabricated. Then these appliance was applied until patients underwent lip surgery. In all cases, the patients could wear the appliance all day since they were able to eat even with the appliance on, This resulted in significant improvements in the nasal symmetry were found. Our appliance, namely K-NAM, extends the wearing time within the limited period and as a result it is expected to maximize the treatment effects. Used properly, this appliance would play a major role in enhancing nasal symmetry with satisfactory results.