• 제목/요약/키워드: Orthodontic brackets

검색결과 150건 처리시간 0.033초

Correction of palatally displaced maxillary lateral incisors without brackets

  • Choi, Kyung-Hee;Lee, Yoonjung;Kim, Minji;Chun, Youn-Sic
    • 대한치과교정학회지
    • /
    • 제43권4호
    • /
    • pp.201-206
    • /
    • 2013
  • This article describes the orthodontic treatment of a 25-year-old Korean female patient with anterior crowding, including palatally displaced lateral incisors. Her facial profile was satisfactory, but 3.5 mm of maxillary anterior crowding was observed. To correct this crowding, we decided to minimize the use of the conventional fixed orthodontic appliances and employed a less bulky and more aesthetic appliance for applying light continuous force. We determined the final positions of the maxillary teeth via a working model for diagnostic set up and achieved space gaining and alignment with simple Ni-Ti spring and stainless steel round tubes. Tooth alignment was achieved efficiently and aesthetically without the conventional brackets.

치아교정용 호선의 굽힘 영향 예측 (Prediction of the Bending Effect of an Archwire for Orthodontics)

  • 이기준;조영수;김시범;이권희
    • 한국기계가공학회지
    • /
    • 제9권6호
    • /
    • pp.95-100
    • /
    • 2010
  • For orthodontic treatment, most commonly, an archwire is inserted into orthodontic brackets that can be made from stainless steel. Then, the archwires interact with the brackets to move teeth into the desired positions. However, the activation of an archwire may induce undesirable rotation of a tooth due to the moment application. An appropriate magnitude of the gable bends of an archwires prevents its rotation. However, it is not easy to predict the relationship between the rotation and the gable bend. This study presents the numerical approach to predict the rotation of a tooth with respect to the gable bend in the activation of an archwire. To predict the rotation of a tooth, the kriging interpolation method is introduced.

Time series analysis of patients seeking orthodontic treatment at Seoul National University Dental Hospital over the past decade

  • Lim, Hyun-Woo;Park, Ji-Hoon;Park, Hyun-Hee;Lee, Shin-Jae
    • 대한치과교정학회지
    • /
    • 제47권5호
    • /
    • pp.298-305
    • /
    • 2017
  • Objective: This paper describes changes in the characteristics of patients seeking orthodontic treatment over the past decade and the treatment they received, to identify any seasonal variations or trends. Methods: This single-center retrospective cohort study included all patients who presented to Seoul National University Dental Hospital for orthodontic diagnosis and treatment between January 1, 2005 and December 31, 2015. The study analyzed a set of heterogeneous variables grouped into the following categories: demographic (age, gender, and address), clinical (Angle Classification, anomaly, mode of orthodontic treatment, removable appliances for Phase 1 treatment, fixed appliances for Phase 2 treatment, orthognathic surgery, extraction, mini-plate, mini-implant, and patient transfer) and time-related variables (date of first visit and orthodontic treatment time). Time series analysis was applied to each variable. Results: The sample included 14,510 patients with a median age of 19.5 years. The number of patients and their ages demonstrated a clear seasonal variation, which peaked in the summer and winter. Increasing trends were observed for the proportion of male patients, use of non-extraction treatment modality, use of ceramic brackets, patients from provinces outside the Seoul region at large, patients transferred from private practitioners, and patients who underwent orthognathic surgery performed by university surgeons. Decreasing trends included the use of metal brackets and orthodontic treatment time. Conclusions: Time series analysis revealed a seasonal variation in some characteristics, and several variables showed changing trends over the past decade.

BRACKET과 호선의 금속유리 (METAL RELEASE FROM BRACKETS AND ARCHWIRES)

  • 박수병;이병태
    • 대한치과교정학회지
    • /
    • 제19권2호
    • /
    • pp.75-84
    • /
    • 1989
  • The purpose of this experiment was to measure the amounts of nickel and chromium released from a simulated orthodontic appliance in artificial saliva. Simulated mandibular half-arch orthodontic appliances were composed of American Iron and Steel Institute type 304 brackets, Permachrome, Elgiloy, Australian wire, T.M.A. and Nitinol. The amounts of nickel and chromium released from sample were measured with atomic absorption spectrophotometer after 3, 6, 9, 12, 15 days. The cumulative amounts of nickel released from Permachrome, Elgiloy, Australian wire and T.M.A. reached a plateau after 6 days. But the cumulative amounts of nickel released from Nitinol increased continuously. Significant amounts of both nickel and chromium were solubilized from the simulated orthodontic appliances into artificial saliva. After 15 days, total cumulative amounts of nickel were $152.15{\mu}g$, $150.27{\mu}g$, $134.74{\mu}g$, $114.67{\mu}g$ and $93.39{\mu}$ from the Elgiloy, Australian wire, Nitinol, Permachrome and T.M.A., respectively. Total cumulative amounts of chromium from Permachrome, Australian wire, Elgiloy, Nitinol and T.M.A. were $100.83{\mu}g$, $83.64{\mu}g$, $81.61{\mu}g$, $14.90{\mu}g$ and $12.43{\mu}g$, respectively. The result showed that nickel released from Elgiloy and chromium released from Permachrome were more than any others.

  • PDF

Effectiveness of medical coating materials in decreasing friction between orthodontic brackets and archwires

  • Arici, Nursel;Akdeniz, Berat S.;Oz, Abdullah A.;Gencer, Yucel;Tarakci, Mehmet;Arici, Selim
    • 대한치과교정학회지
    • /
    • 제51권4호
    • /
    • pp.270-281
    • /
    • 2021
  • Objective: The aim of this in vitro study was to evaluate the changes in friction between orthodontic brackets and archwires coated with aluminum oxide (Al2O3), titanium nitride (TiN), or chromium nitride (CrN). In addition, the resistance of the coatings to intraoral conditions was evaluated. Methods: Stainless steel canine brackets, 0.016-inch round nickel-titanium archwires, and 0.019 × 0.025-inch stainless steel archwires were coated with Al2O3, TiN, and CrN using radio frequency magnetron sputtering. The coated materials were examined using scanning electron microscopy, an X-ray diffractometer, atomic force microscopy, and surface profilometry. In addition, the samples were subjected to thermal cycling and in vitro brushing tests, and the effects of the simulated intraoral conditions on the coating structure were evaluated. Results: Coating of the metal bracket as well as nickel-titanium archwire with Al2O3 reduced the coefficients of friction (CoFs) for the bracket-archwire combination (p < 0.01). When the bracket and stainless steel archwire were coated with Al2O3 and TiN, the CoFs were significantly lower (0.207 and 0.372, respectively) than that recorded when this bracket-archwire combination was left uncoated (0.552; p < 0.01). The friction, thermal, and brushing tests did not deteriorate the overall quality of the Al2O3 coatings; however, some small areas of peeling were evident for the TiN coatings, whereas comparatively larger areas of peeling were observed for the CrN coatings. Conclusions: Our findings suggest that the CoFs for metal bracket-archwire combinations used in orthodontic treatment can be decreased by coating with Al2O3 and TiN thin films.

Reasons influencing the preferences of prospective patients and orthodontists for different orthodontic appliances

  • Maranon-Vasquez, Guido Artemio;Barreto, Luisa Schubach da Costa;Pithon, Matheus Melo;Nojima, Lincoln Issamu;Nojima, Matilde da Cunha Goncalves;Araujo, Monica Tirre de Souza;de Souza, Margareth Maria Gomes
    • 대한치과교정학회지
    • /
    • 제51권2호
    • /
    • pp.115-125
    • /
    • 2021
  • Objective: To evaluate the reasons influencing the preferences for a certain type of orthodontic appliance over another among prospective patients (PP) and orthodontists. Methods: A total of 49 PP and 51 orthodontists were asked about their preferences for the following appliances: clear aligners (CA), lingual metallic brackets (LMB), polycrystalline and monocrystalline ceramic brackets, and buccal metallic brackets (BMB). The participants rated the importance of 17 potential reasons that would explain their choices. The reasons that contributed most to these preferences were identified. Non-parametric tests (Fisher's exact, χ2 and Mann-Whitney tests) and multivariate analyses (regression and discriminant analysis) were used to assess the data (α = 0.05). Results: CA and BMB were the most chosen appliances by PP and orthodontists, respectively. LMB was the most rejected option among both groups of participants (p < 0.001). Rates of the importance of pain/discomfort, smile esthetics, finishing details, and feeding/speech impairment showed the highest differences between PP and orthodontists (p < 0.0005). Discriminant analyses showed that individuals who considered treatment time and smile esthetics as more important were more likely to prefer CA, while those who prioritized finishing details and cost were more likely to choose BMB (p < 0.05). Conclusions: Reasons related to comfort and quality of life during use were considered as more important by PP, while those related to the results and clinical performance of the appliances were considered as more relevant by orthodontists.

Variation in adhesion of Streptococcus mutans and Porphyromonas gingivalis in saliva-derived biofilms on raw materials of orthodontic brackets

  • Park, So-Hyun;Kim, Kyungsun;Cho, Soha;Chung, Dong-Hwa;Ahn, Sug-Joon
    • 대한치과교정학회지
    • /
    • 제52권4호
    • /
    • pp.278-286
    • /
    • 2022
  • Objective: To evaluate differences in the adhesion levels of the most common oral pathogens, Streptococcus mutans and Porphyromonas gingivalis, in human saliva-derived microcosm biofilms with respect to time and raw materials of orthodontic brackets. Methods: The samples were classified into three groups of bracket materials: 1) monocrystalline alumina ceramic (CR), 2) stainless steel metal (SS), and 3) polycarbonate plastic (PL), and a hydroxyapatite (HA) group was used to mimic the enamel surface. Saliva was collected from a healthy donor, and saliva-derived biofilms were grown on each sample. A real-time polymerase chain reaction was performed to quantitatively evaluate differences in the attachment levels of total bacteria, S. mutans and P. gingivalis at days 1 and 4. Results: Adhesion of S. mutans and P. gingivalis to CR and HA was higher than the other bracket materials (SS = PL < CR = HA). Total bacteria demonstrated higher adhesion to HA than to bracket materials, but no significant differences in adhesion were observed among the bracket materials (CR = SS = PL < HA). From days 1 to 4, the adhesion of P. gingivalis decreased, while that of S. mutans and total bacteria increased, regardless of material type. Conclusions: The higher adhesion of oral pathogens, such as S. mutans and P. gingivalis to CR suggests that the use of CR brackets possibly facilitates gingival inflammation and enamel decalcification during orthodontic treatment.

Comparative evaluation of shear bond strength of orthodontic brackets bonded to three-dimensionally-printed and milled materials after surface treatment and artificial aging

  • Ameer Biadsee;Ofir Rosner;Carol Khalil;Vanina Atanasova;Joel Blushtein;Shifra Levartovsky
    • 대한치과교정학회지
    • /
    • 제53권1호
    • /
    • pp.45-53
    • /
    • 2023
  • Objective: This study aimed to evaluate the shear bond strength (SBS) of orthodontic brackets bonded to three-dimensionally (3D)-printed materials after various surface treatments and artificial aging compared with that bonded to computer-aided design/computer-aided manufacturing (CAD-CAM) polymethyl methacrylate (PMMA)-milled materials. Methods: Eighty cylindrical specimens were 3D printed and divided into the following four subgroups (n = 20 each) according to the surface treatment and artificial aging procedure. Group A, sandblasted with 50 ㎛ aluminum oxide particles (SA) and aging; group B, sandblasted with 30 ㎛ silica-coated alumina particles (CO) and aging; group C, SA without aging; and group D, CO without aging. For the control group, 20 CAD-CAM PMMA-milled cylindrical specimens were sandblasted with SA and aged. The SBS was measured using a universal testing machine (0.25 mm/min), examined at ×2.5 magnification for failure mode classification, and statistically analyzed (p = 0.05). Results: The retention obtained with the 3D-printed materials (groups A-D) was higher than that obtained with the PMMA-milled materials (control group). However, no significant difference was found between the study and control groups, except for group C (SA without aging), which showed significantly higher retention than the control group (PMMA-SA and thermocycling) (p = 0.037). Study groups A-D predominantly exhibited a cohesive specimen mode, indicating specimen fracture. Conclusions: Orthodontic brackets bonded to 3D-printed materials exhibit acceptable bonding strengths. However, 3D-printed materials are prone to cohesive failure, which may result in crown fractures.

녹차 결명자 추출물의 교정용 브라켓과 치면 사이의 경계부에서 분리된 mutans streptococci에 대한 항균작용 (Effect of Leaf-Extract from Camellia sinensis and Seed-Extract from Casia tora on Viability of Mutans Streptococci isolated from the interface between orthodontic brackets and tooth surfaces)

  • 임성훈;서정순;윤영주;김광원;유소영;김화숙;국중기;이병래;차종희;박재윤
    • 대한치과교정학회지
    • /
    • 제33권5호
    • /
    • pp.381-389
    • /
    • 2003
  • 본 연구는 치아우식증에 관련된 Hutans streptococci 표준균주 및 임상분리 균주의 성장억제를 유도할 수 있는 천연생약추출물을 검색하기 위하여 실시되었다. 녹차추출물은 CHMC-2032를 사용하였으며, 결명자 추출물은 $50\%$ 에탄올을 이용하여얻었다. 이들 추출물의 Mutans streptococci표준균주 및 교정환자들에서 브라켓과 치면 사이의 경계부에서 분리된 각각 10 균주씩의 S. mutans 및 S. sobrinus에 대한 최소성장억제농도를 액체배지 희석법으로 구하였다. 그 결과 CHMC-2032의 S. mutans 및 S. sobrinus의 표준 균주, S. sobrinus의 대부분 임상분리 균주에 대한 최소성장 억제농도는 5mg/ml이었다 그러나 결명자 추출물에 의한 S. mutans 및 S. sobrinus에 대한 세균 성장억제 효과는 미미하였다. 본 연구 결과 치아우식증의 예방적 측면에서 결명자차보다는 녹차를 마시는 것이 유리하며, CHMC-2032를 이용하여 구강양치용액을 제조하여 사용할 경우 교정환자를 포함하여 대부분의 사람에게서 치아우식증 예방 효과가 있으리고 추정된다.

클로르헥시딘 바니쉬의 적용이 교정용 브라켓의 전단접착강도에 미치는 영향 (The effect of chlorhexidine varnish application on the shear bond strength of orthodontic brackets)

  • 임동혁;김태우;장영일;남동석;양원식;백승학
    • 대한치과교정학회지
    • /
    • 제30권2호
    • /
    • pp.215-222
    • /
    • 2000
  • 본 연구의 목적은 클로르헥시딘 처리가 교정용 브라켓의 전단접착강도와 탈락 양상에 미치는 영향을 비교하는 것이다. 실험군으로 4주간 4회의 클로르헥시딘 바니쉬를 도포한 22개의 사람 소구치를 선택하였고, 대조군으로 아무 처리도 하지 않은 22개의 사람 소구치를 선택하였다. 모든 치아는 $37\%$의 phosphoric acid gel로 부식시키고 교정용 브라켓을 같은 조건으로 부착시켰다. 전단접착강도의 측정을 위해 Instron universal testing machine(model 4466)을 이용하였고, 법랑질과 브라켓 표면은 SEM으로 관찰하였다. 결과의 분석은 t-test를 이용하였으며 결과는 다음과 같다. 1. 클로르헥시딘의 법랑질 처리는 전단접착강도에 영향을 미치지 않았다. 2. 클로르헥시딘으로 법랑질을 처리한 경우와 그렇지 않는 경우에 브라켓 탈락 양상에 차이가 없었다. 따라서, 클로르헥시딘으로 법랑질을 처리하여도 브라켓 접착에 유해한 작용이 없었고, 따라서 임상사용에 적합하다고 생각된다.

  • PDF