• Title/Summary/Keyword: Orthodontic archwire

Search Result 44, Processing Time 0.018 seconds

Orthodontic pain control following arch wire placement; a comparison between pre-emptive tenoxicam and chewing gum: a randomized clinical trial

  • Basam, Lakshman Chowdary;Singaraju, Gowri Sankar;Obili, Sobitha;Keerthipati, Thejasree;Basam, Ram Chowdary;Prasad, Mandava
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.2
    • /
    • pp.107-116
    • /
    • 2022
  • Background: Pain during fixed orthodontic treatment can have a detrimental effect on patient treatment compliance. To overcome this, there is a definite need to establish the best pain-relieving methods suitable for orthodontic patients in terms of efficacy and use. The objective of this study was to compare the effect of chewing gum and pre-emptive tenoxicam on pain after initial archwire placement and to evaluate the pain perceptions of orthodontic patients in the two groups while performing various functions at specific time intervals. Methods: Forty-two patients were selected and randomly divided into two groups: group A (chewing gum) and group B (pre-emptive tenoxicam). Pain perception was documented by patients immediately; at 4 h; at bedtime on the day of archwire placement; the next morning; at 24 h; and at bedtime on the 2nd, 3rd, and 7th day after the initial archwire placement. Pain scores were noted during fitting of the posterior teeth, biting, and chewing using a visual analog scale. The data obtained were subjected to statistical analysis. Results: Group A showed a significant increase in pain until the next morning while fitting the posterior teeth, biting, and chewing [36.2, 52.0, 33.4, respectively]], followed by a gradual decrease by the 7th day. Group B showed a significant increase in pain at bedtime on biting, with a peak value of 47.5. Pain on chewing, fitting posterior teeth, peaked the morning of the next day (100.0, 45.0). The Freidman test showed a statistically significant difference with a p-value of < 0.01. Higher pain scores were observed while chewing and biting compared with that while fitting the posterior teeth in both groups. The overall comparison of pain control between the two groups was not statistically significant [P > 0.05] between the two groups. Conclusions: Chewing gum was not inferior to pre-emptive tenoxicam. Thus, chewing gum is a non-pharmacological alternative to analgesics for orthodontic pain control that eliminates the chance of adverse reactions and can be used in the absence of adult observation.

COMPARISON OF THE FRICTIONAL RESISTANCE BETWEEN ORTHODONTIC BRACKET & ARCHWIRE (교정용 BRACKET과 ARCHWIRE 사이의 마찰저항에 대한 비교연구)

  • Sung, Hyun Mee;Park, Young Chel
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.543-560
    • /
    • 1991
  • Practitioners are aware of the presence of friction between bracket system and archwire during sliding movement of teeth. Clinically a mesiodistally applied force must exceed the frictional force to produce a tooth movement. The objective of this study were to determine, on a dry condition, changes in magnitude of friction with respect to load, 3rd order inclination (Torque), archwire materials and ligature type. Three wire alloys (Stainless Steel, TMA, NiTi) in two wire sizes (.016, .016x, .022 inch) were examined respect to two bracket system (Straight, Standard), and two ligature type (Metal, Plastic ligature) at three levels of load (100g, 150g, 200g). The results were as follows; 1. Frictional resistance was found to increase with increasing load for S.S., TMA, NiTi. 2. The straight bracket system was exhibited more frictional force than standard bracket system for .016x, .022 S.S. tightly ligated metal ligature. But, torque difference did not increase friction for loose metal ligature & plastic ligature. 3. Regardless of the ligature type, torque and load, stainless steel wire sliding against stainless steel exhibited the lowest friction, and TMA sliding against stainless steel exhibited the highest friction. 4. The loose stainless steel ligature generated lower frictional resistance than plastic ligature in all experimental groups. 5. The following factors affected friction in decreasing order; wire material ligature type, and load.

  • PDF

A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type

  • Lee, Souk Min;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.45 no.1
    • /
    • pp.13-19
    • /
    • 2015
  • Objective: This study aimed to compare the frictional force (FR) in self-ligating brackets among different bracket-archwire angles, bracket materials, and archwire types. Methods: Passive and active metal self-ligating brackets and active ceramic self-ligating brackets were included as experimental groups, while conventional twin metal brackets served as a control group. All brackets were maxillary premolar brackets with 0.022 inch [in] slots and a $-7^{\circ}$ torque. The orthodontic wires used included 0.018 round and $0.019{\times}0.025$ in rectangular stainless steel wires. The FR was measured at $0^{\circ}$, $5^{\circ}$, and $10^{\circ}$ angulations as the wire was drawn through the bracket slots after attaching brackets from each group to the universal testing machine. Static and kinetic FRs were also measured. Results: The passive self-ligating brackets generated a lower FR than all the other brackets. Static and kinetic FRs generally increased with an increase in the bracket-archwire angulation, and the rectangular wire caused significantly higher static and kinetic FRs than the round wire (p < 0.001). The metal passive self-ligating brackets exhibited the lowest static FR at the $0^{\circ}$ angulation and a lower increase in static and kinetic FRs with an increase in bracket-archwire angulation than the other brackets, while the conventional twin brackets showed a greater increase than all three experimental brackets. Conclusions: The passive self-ligating brackets showed the lowest FR in this study. Self-ligating brackets can generate varying FRs in vitro according to the wire size, surface characteristics, and bracket-archwire angulation.

Chewing gum as a non-pharmacological alternative for orthodontic pain relief: A randomized clinical trial using an intention-to-treat analysis

  • da Silva Santos, Diego Junior;Capelli, Jonas Jr.
    • The korean journal of orthodontics
    • /
    • v.51 no.5
    • /
    • pp.346-354
    • /
    • 2021
  • Objective: To compare the effectiveness of ibuprofen, acetaminophen, and chewing gum for orthodontic pain relief and to assess if chewing gum can be a non-pharmacological alternative for orthodontic pain relief. Methods: The study enrolled 106 patients of both sexes, aged ≥ 12 years, with body weight > 50 kg, and mild-to-moderate dental crowding in the upper arch. After randomization and allocation concealment, the intervention groups were either administered with ibuprofen (400 mg) or acetaminophen (500 mg) or chewed sugar-free chewing gum immediately after initial archwire placement and every 6 hours for 1 week if the pain persisted. The control group did not receive any pain relief. The pain was assessed on a 100-mm visual analog scale at rest and while biting down at T1 (2 hours), T2 (24 hours), T3 (2 days), T4 (3 days), T5 (7 days), and T6 (21 days). Statistical analyses were performed using the Kruskal-Wallis and post-hoc Mann-Whitney U tests (α = 0.05). Results: The chewing gum group experienced more pain relief than the ibuprofen group at while biting down at T3 (p = 0.04) and at rest at T4 (p < 0.001). The chewing gum group reported more pain relief than the acetaminophen and control groups while biting down at T3 (p = 0.03 and p = 0.0006, respectively) and T4 (both p < 0.001). Conclusions: Chewing gum can be a non-pharmacological alternative for orthodontic pain relief at 2 and 3 days after initial archwire placement.

Correction of Angle Class II division 1 malocclusion with a mandibular protraction appliances and multiloop edgewise archwire technique

  • Freitas, Benedito;Freitas, Heloiza;dos Santos, Pedro Cesar F.;Janson, Guilherme
    • The korean journal of orthodontics
    • /
    • v.44 no.5
    • /
    • pp.268-277
    • /
    • 2014
  • A Brazilian girl aged 14 years and 9 months presented with a chief complaint of protrusive teeth. She had a convex facial profile, extreme overjet, deep bite, lack of passive lip seal, acute nasolabial angle, and retrognathic mandible. Intraorally, she showed maxillary diastemas, slight mandibular incisor crowding, a small maxillary arch, 13-mm overjet, and 4-mm overbite. After the diagnosis of severe Angle Class II division 1 malocclusion, a mandibular protraction appliance was placed to correct the Class II relationships and multiloop edgewise archwires were used for finishing. Follow-up examinations revealed an improved facial profile, normal overjet and overbite, and good intercuspation. The patient was satisfied with her occlusion, smile, and facial appearance. The excellent results suggest that orthodontic camouflage by using a mandibular protraction appliance in combination with the multiloop edgewise archwire technique is an effective option for correcting Class II malocclusions in patients who refuse orthognathic surgery.

Variations in surface roughness of seven orthodontic archwires: an SEM-profilometry study

  • Amini, Fariborz;Rakhshan, Vahid;Pousti, Maryam;Rahimi, Hajir;Shariati, Mahsa;Aghamohamadi, Bahareh
    • The korean journal of orthodontics
    • /
    • v.42 no.3
    • /
    • pp.129-137
    • /
    • 2012
  • Objective: The purpose of this study was to evaluate the surface roughness (SR) of 2 types of orthodontic archwires made by 4 different manufacturers. Methods: This in vitro experimental study was conducted on 35 specimens of 7 different orthodontic archwires, namely, 1 nickel-titanium (NiTi) archwire each from the manufacturers American Orthodontics, OrthoTechnology, All-Star Orthodontics, and Smart Technology, and 1 stainless steel (SS) archwire each from the manufacturers American Orthodontics, OrthoTechnology, and All-Star Orthodontics. Aft er analyzing the composition of each wire by energy-dispersive X-ray analysis, the SR of each wire was determined by scanning electron microscopy (SEM) and surface profilometry. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests (${\alpha}$ < 0.05). Results: The average SR of NiTi wires manufactured by Smart Technology, American Orthodontics, OrthoTechnology, and All-Star Orthodontics were $1,289{\pm}915A^{\circ}$, $1,378{\pm}372A^{\circ}$, $2,444{\pm}369A^{\circ}$, and $5,242{\pm}2,832A^{\circ}$, respectively. The average SR of SS wires manufactured by All-Star Orthodontics, OrthoTechnology, and American Orthodontics were $710{\pm}210A^{\circ}$, $1,831{\pm}1,156A^{\circ}$, and $4,018{\pm}2,214A^{\circ}$, respectively. Similar to the results of profilometry, the SEM images showed more defects and cracks on the SS wire made by American Orthodontics and the NiTi wire made by All-Star Orthodontics than others. Conclusions: The NiTi wire manufactured by All-Star Orthodontics and the SS wire made by American Orthodontics were the roughest wires.

A CEPHALOMETRIC EVALAUATION OF ANTERIOR OPENBITE MALOCCLUSIONS TREATED BY MULTILOOP EDGEWISE ARCHWIRE TECHNIQUE (Multiloop edgewise Archwire 기법으로 치료된 전치 개교 증례의 두부방사선사진 계측학적 평가)

  • Moon, Seong-Cheol;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.23 no.4 s.43
    • /
    • pp.565-606
    • /
    • 1993
  • The purpose of this study was to evaluate the change of before and after treatment of anterior openbite malocclusions treated by Multiloop Edgewise Archwire technique. The openbite sample consisted of 4 male and 12 female adults, treated with nonextraction or third molar extraction. The normal sample consisted of 58 subjects, which have pleasing facial profile and normal occlusion and no experience of orthodontic or prosthodontic treatment. The 58 subjects of normal sample were subdivided by cephalemetric vertical relationship of face. The 40 subjects, cephalometric vertical relationship of face was in normal range, classified as Normal Sample group 1. The 18 subjects, increased cephalometric vertical relationship of face, classified as Normal Sample group 2. The computerized cephalometric analysis was accomplished with 50 reference points for 22 skeletal measurements, 46 dentoalveolar measurements, 8 soft tissue measurements. Statistical analysis of the data was carried out with paired t-test, Student's t-test, and DUNCAN test using SAS(PC version), The results were as follows : 1. There were no statistically significant differences in skeletal measurement between before and after treatment. The major changes were in dentoalveolar region. 2. After treatment, the long axis of maxillary and mandibular posterior teeth were distally tipped-back, and uprighted to bisected occlusal plane. The interincisal angle was increased. 3. There were no statistically significant increase in the upper posterior dental height and statistically significant decrease in the lower posterior dental height. The upper anterior dental height was increased, but there was no statistically significant increase in the absolute upper anterior dental hight. The lower anterior dental height was increased. 4. After treatment, the maxillary occlusal plane to palatal plane angle and the mandibular occlusal plane to mandibular plane angle were statistically significant increased. Then, there were no statistically significant difference between after treatment group and normal sample group 2. 5. After treatment, the percentage of upper lip length to upper anterior dental height was decreased. Then, There were no statistically significant difference between after treatment group and normal sample group 2.

  • PDF

FRICTIONAL FORCES IN THE FIXED ORTHODONTIC APPLIANCE DURING TOOTH MOVEMENT (고정성 교정장치를 이용한 치아이동시 발생되는 마찰력)

  • Cho, Myeong-Sook;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.20 no.2
    • /
    • pp.409-417
    • /
    • 1990
  • Tooth movement would be impeded by frictional force arised between archwire and tube, bracket or elastics in the fixed orthodontic appliances, which could be changed variably by such several factors as the contact area, normal (perpendicular) force and the condition of contact surface. There were many literatures about frictional force in the orthodontic region, but different results were obtained from little controlled research so that was very difficult in clinical application. Therefore we have reviewed comprehensively previous literatures about frictional force and thus several results were obtained as follows: 1. For use species of the orthodontic wire, frictional force was influenced mainly by surface roughness of wire in the absence of binding, while that was influenced mainly by normal force in high binding angulation. 2. For the cross-section and diameter of the wire, the contact area influenced mainly on frictional force in the absence of binding, while wire stiffness influenced mainly on frictional force in high binding angulation. 3. The greater the bracket width, the greater frictional force, and frictional force of the plastic bracket was larger than that of the metal bracket. 4. For ligation type, frictional force of the stainless steel ligation was larger than that of the elastic ligation, and frictional force was directly proportional to ligation force. 5. Variable frictional force were occured from the saliva combined with such another factors as normal force and mode of surface oxide et al.

  • PDF

Effects of self-ligating brackets and other factors influencing orthodontic treatment outcomes: A prospective cohort study

  • Jung, Min-Ho
    • The korean journal of orthodontics
    • /
    • v.51 no.6
    • /
    • pp.397-406
    • /
    • 2021
  • Objective: The purpose of this study was to evaluate the effects of self-ligating brackets (SBs) and other factors that influence orthodontic treatment outcomes. Methods: This two-armed cohort study included consecutively treated patients in a private practice. The patients were asked to choose between SBs and conventional brackets (CBs); if any patient did not have a preference, he or she was randomly allocated to the CB or SB group. All patients were treated using an identical archwire sequence. Evaluated parameters were as follows: treatment duration, number of bracket failures, poor oral hygiene, poor elastic wear, extraction, use of orthodontic mini-implants (OMI), OMI failure, American Board of Orthodontics (ABO) Discrepancy Index (DI), arch length discrepancy, and ABO Cast-Radiograph Evaluation (CRE) score. Stepwise regression analysis was performed to generate the equation for prediction of the CRE. Results: The final sample comprised 134 patients with an average age of 22.73 years. The average DI, CRE, and treatment duration were 21.81, 14.25, and 28.63 months, respectively. Analysis of covariance showed a significant difference in CRE between the CB and SB groups after adjusting for the effects of confounding variables. Stepwise regression analysis using four variables, namely extraction, SB use, poor elastic wear, and additional appliance use, could explain only 25.2% of the variance in the CRE. Conclusions: Although the CRE was significantly better for CBs than for SBs, the clinical significance of this result seems to be limited. Extraction, SB use, poor elastic wear, and additional appliance use may have significant effects on treatment outcomes.

A photoelastic study on the initial stress distribution of the upper anterior teeth retraction using combination loop archwire and sliding mechanics (Combination loon archwire와 활주역학을 이용한 상악전치의 후방 견인시 나타나는 초기 응력 분포에 관한 광탄성학적 연구)

  • Yim, Kang-Soon;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.303-312
    • /
    • 2004
  • An unfavorable tipping movement can occur during the retraction of anterior teeth because orthodontic force is loaded by brackets positioned far from the center of resistance. To avoid this unfavorable movement, a compensating curved wire or lingual root torque wire is used. The purpose of this study is to investigate, using photoelastic material, the distribution of initial stress associated with the retraction of the incisors according to the degree of the compensating curve, to model changes associated with tooth ud alveolar bone structure. The following results were obtained by analysis of the polarizing plate of the effects of initial stress resulting from retraction of the anterior teeth: 1. When the incisors were retracted using combination archwire or sliding mechanics, the maximal polarizing pattern of the apical area decreased as the degree of the compensating owe increased from 0 to 15 to 30. 2. When the incisors were retracted by the combination archwire or sliding mechanics, the maximal polarizing pattern of the canine and premolar area increased as the degree of the compensating curve increased from 0to 15to 30. 3. A lower degree of polarizing patterns were associated with the combination archwire technique than the sliding mechanics technique at a given force. The above results indicate that there is no significant difference between the combination loop archwire technique and sliding mechanics, for the retraction of maxillary anterior teeth with decreased lingual tipping tendency by a compensating curve on the arch wire. However, the use of sliding mechanics is more effective for the prevention of lingual inclination of the anterior teeth, because the hook used in sliding mechanics is closer to the center of resistance of the maxillary anterior teeth.