• 제목/요약/키워드: Orthodontic Wire

Search Result 142, Processing Time 0.032 seconds

Digital Orthodontics using Customized Appliance System (개인 맞춤형 장치를 이용한 디지털 교정치료)

  • Kim, Yoon-Ji R.;Ha, Hye-Jung;Lee, Sung-Jong;Lee, Eon-Hwa;Ryu, Jae-Jun
    • The Journal of the Korean dental association
    • /
    • v.54 no.2
    • /
    • pp.134-141
    • /
    • 2016
  • Use of ready-made orthodontic appliance can lead to inefficiencies in the final stages of the orthodontic treatment. Because patients' teeth have anatomic variations, brackets that have been designed to fit on average tooth surface may result in positional discrepancies when leveling and alignment is completed. As a result, additional steps such as rebonding, wire bending and use of auxiliaries may be needed. Even in patients who have normal tooth anatomy and proper tooth size relationships, precise bracket placement is crucial in order to efficiently control the tooth positions. Digital models can provide advantages in clinical orthodontics as virtual tooth setup could be performed, and clinicians can easily visualize the predicted final occlusion. Through this setup model, customized brackets with individualized prescription and archwires that optimally fit with the patients' dental arches can be produced using CAD/CAM technology. Also, the brackets can be accurately placed with an aid of 3D-printed jigs. The purpose of this article is to introduce the commonly used labial and lingual customized orthodontic appliance systems using digital technology.

  • PDF

A New Orthodontic Appliance for Rapid Anterior Alignment in Adults; Mini-Tube Appliance (MTA) (성인 전치부 부분교정을 위한 새로운 교정장치 MTA의 이용)

  • Hwang, Hyeon-Shik;Jeon, Hyun-Ran;Kim, Seok-Pil;Kim, Wang-Sik;Lee, Gye-Hyeong
    • The Journal of the Korean dental association
    • /
    • v.49 no.7
    • /
    • pp.398-409
    • /
    • 2011
  • With an increase of public's perception on "minimally invasive dentistry", more patients are demanding orthodontic alignment of anterior teeth rather than restorative treatment which is more invasive. One draw back of orthodontic alignment has been that it takes long time. To overcome this limitation, a new orthodontic device named Mini-Tube Appliance (MTA), have been developed. With the combined use of light NiTi wire and inter-proximal stripping, rapid anterior alignment can be obtained efficiently. This article presents the use of MTA for rapid alignment of anterior teeth and its clinical guidelines with typical case samples.

A Study of shear bond strength of bonded retainer according to the bonding method and type of wires (접착방법 및 multistranded wire의 종류에 따른 접착식 보정장치의 전단접착강도에 관한 연구)

  • Lee, Hyoung-Cheol;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.143-153
    • /
    • 2002
  • The bonded orthodontic retainer constructed from composite and multistrand orthodontic wire provides an esthetic and efficient system for maintained retention. This study was designed to measure shear bond strength of bonded retainers and to suggest a optimal combination of a multistrand wire and bonding method used when bonded retainer was fabricated. 160 sound maxillary and mandibular premolars were used for 80 test samples. After Uniformizing bonding area, length of wire, and thickness of composite, multistrand wire was bonded to fabricated a bonded retainer by direct or indirect bonding method. Shear bond strength and extension length of each sample were measured by a universal testing machine. The results of this study were as follows : 1. In vitro shear bond testing found 6-stranded, 0.0155 inch wires to have the largest shear bond strength and 3-stranded, 0.0195 inch wires to have the least shear bond strength. But, These difference was not statistically significant(p<0.05). 2. In vitro extension testing found 3-stranded, 0.0155 inch wires to have the largest extension length and 3-stranded, 0.0195 inch wires to have the least extension length(p<0.05). The larger diameter wire was used, the larger extension length was shown. But, the strand of wire is not related to the extension length of wire. 3. In comparison with direct bonding method, larger shear bond strength and extension length was shown in indirect bonding method(p<0.05).

Electrochemical Characteristics of Tooth Colored NiTi Wire (치아색으로 코팅된 NiTi 와이어의 전기화학적 특성)

  • Kim, Won-Gi;Cho, Joo-Young;Choe, Han-Cheol;Lee, Ho-Jong
    • Corrosion Science and Technology
    • /
    • v.9 no.5
    • /
    • pp.223-232
    • /
    • 2010
  • NiTi alloy has been used for orthodontic wire due to good mechanical properties, such as elastic strength, friction resistance, and high corrosion resistance. Recently, these wire were coated by polymer and ceramic materials for aesthetics. The purpose of this study was to investigate electrochemical characteristics of tooth colored NiTi wire using various instruments. Wires (round type and rectangular type) were used, respectively, for experiment. Polymer coating was carried out for wire. Specimen was investigated with optical microscopy (OM), field emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy (EDS). The corrosion properties of the specimens were examined using potentiodynamic tests (potential range of -1500 ~ 2000 mV) and electrochemical impedance spectroscopy (frequency range of 100 kHz ~ 10 mHz) in a 0.9 % NaCl solution by potentiostat. From the results of polarization behavior, the passive region of non-coated NiTi wire showed largely, whereas, the passive region of curved NiTi wire showed shortly in anodic polarization curve. In the case of coated NiTi wire, pitting and crevice corrosion occurred severely at interface between non-coated and coated region. From the results of EIS, polarization resistance(Rp) value of non-coated round and rectangular NiTi wire at curved part showed $5.10{\times}10^5{\Omega}cm^2$ and $4.43{\times}10^5{\Omega}cm^2$. lower than that of coated NiTi wire. $R_p$ of coated round and rectangular NiTi wire at curved part showed $1.31{\times}10^6{\Omega}cm^2$ and $1.19{\times}10^6{\Omega}cm^2$.

Surface Characteristics of Polymer Coated NiTi Alloy Wire for Orthodontics (폴리머 코팅된 NiTi합금 교정선의 표면특성)

  • Cho, Joo-Young;Kim, Won-Gi;Choi, Hwan-Suk;Lee, Ho-Jong;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.3
    • /
    • pp.132-141
    • /
    • 2010
  • NiTi alloy has been used for orthodontic wire due to good mechanical properties, such as elastic strength and frictional resistance, combined with a high resistance to corrosion. Recently, these wire were coated by polymer and ceramic materials for aesthetics. The purpose of this study was to investigate surface characteristics of polymer coated NiTi alloy wire for orthodontics using various instruments. Wires (round type and rectangular type) were used, respectively, for experiment. Polymer coating was carried out for wire. Specimen was investigated with field emission scanning electron microscopy(FE-SEM), energy dispersive x-ray spectroscopy(EDS) and atomic force microscopy(AFM). The phase transformation of non-coated NiTi wire from martensite to austenite occurred at the range of $14{\sim}15^{\circ}C$, in the case of coated wire, it occurred at the range of $16{\sim}18^{\circ}C$. Polymer coating on NiTi wire surface decreased the surface defects such as scratch which was formed at severe machined surface. From the AFM results, the average surface roughness of non-coated and coated NiTi wire was 13.1 nm, and 224.5 nm, respectively. From convetional surface roughness test, the average surface roughness of non-coated and coated NiTi wire was $0.046{\mu}m$, and $0.718{\mu}m$, respectively.

A Study on Frictioal Resistance Force of Orthodontic Resin Bracket (교정용 Resin bracket의 마찰 저항력에 관한 연구)

  • Lee, Won-you;Lim, Kyung-Soo
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.107-112
    • /
    • 1999
  • As increasing number of adult patients, the esthetic orthodontic appliances are needed. They are tooth-colored or translucent ceramic and resin brackets. Although ceramic and resin bracket have good esthetics, there are some disadvantage such as frictions. Recently, metal-reinforced resin bracket(MRBB) were introduced. The purpose of this study is to find frictional force of MRRB, ceramic bracket and resin brackets. There is few study in frictional force about metal reinforced resin bracket(MRRB). This study used 4 orthodontic wire(.016 S-S, .0l6X.022 S-S, .016 $TMA^{\circledR}$, .0l7X.025 $TMA^{\circledR}$ and 5 brackets(one metal bracket, one ceramic bracket, one resin bracket, two MRRB). The following result is obtained using metal bracket(Ormco.Co., U.S.A), ceramic brackets($Crystalline^{\circledR}$), resin bracket( Clear Medium $Siamase^{\circledR}$). Following conclusions are obtained. 1. Ceramic and resin bracket have significantly more frictional forces than metal reinforced resin bracket and metal bracket. 2. There is no significant difference in frictional force according to the slot types of metal - reinforced resin brackets. 3. There is no significant difference in frictional force between metal reinforced resin bracket and metal bracket. 4.. Frictional force is decreased in S-S wire than TMA wire.

  • PDF

An experimental study on the cytotoxicity of orthodontic wires (교정용 호선의 세포독성에 관한 실험적 연구)

  • Lim, Yong-Kyu;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.591-599
    • /
    • 1996
  • This study was undertaken to investigate the cytotoxicity of orthodontic wires after doing various treatments to the wires. 018x025 inch Stainless steel(A) and Co-Cr(B) wires were used and each of them were divided into 4 groups. A-1 and B-1 groups were as received state, and A-2 and B-2 groups were heat treated. A-3 and B-3 groups were electropolished after heat treatment, and A-4 and B-4 groups were soldered with Ag-solder. Each group had 3 wires and these were sterilized with Ethylene Oxide gas. We used human gingival fibroblast cell culture and agar overlay technique to investigate the cytotoxicity of each group of wires. The cytotoxicity of wire was assessed using reaction index (zone index/lysis index). The findings of this study were as follows. 1. Both of the stainless steel wire and Co-Cr wire showed no cytotoxicity in as received state. 2. Heat treatment or electropolishing of the wires had no effect on the cytotoxicity of the wires 3. Soldered stainless steel wires showed a little wider zone of discoloration than soldered Co-Cr wires, but the zone index and cytotoxicity(reaction index) was not different. 4. Soldered wires showed moderate cytotoxicity in both of the wires.

  • PDF

A STUDY ON THE MECHANICAL PROPERTIES OF ORTHODONTIC OPEN COIL SPRINGS (교정용 open coil spring의 역학적 특성에 관한 연구)

  • Park, Kyu-Chan;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.22 no.1
    • /
    • pp.135-146
    • /
    • 1992
  • It was the purpose of this study to analyze and compare the mechanical properties of ortho dontic open coil springs. Four variable factors were presented - wire diameter (.008", .009", .010"), lumen size (.030", .032", .036"), arch wire size and shape (.016" round, $ .016^{{\prime}{\prime}}{\times}.022^{{\prime}{\prime}}$ rect.) and alloy type (HiT II, Elgiloy, Sentalloy). The total 104 specimens were divided into 13 groups, and compression test was performed on an Instron test machine. The load deflection curve of each open coil spring was obtained, from which, the load-deflection relations, stiffnesses, percent recoveries were computed statistically. The results were obtained as follows: 1. When the lumen size of the coil spring remained constant, stiffness and percent recovery increased as the wire diameter increased. 2. When the wire diameter of the coil spring remained constant, stiffness and percent recovery decreased as the lumen size increased. 3. The effect of size and shape of arch wire on the coil spring was not statistically significant. 4. In alloy types, stiffness was the greatest in HiT II (55.21), Elgiloy (42.61) and Sentalloy (7.74) in that order. Sentalloy exhibited superior percent recovery and long range of action.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON DURING DISTAL EN MASSE MOVEMENT OF THE MAXILLARY DENTITION (상악 치열의 치군 후방이동에 관한 3 차원 유한요소법적 연구)

  • Shin, Soo-Jung;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.28 no.4 s.69
    • /
    • pp.563-580
    • /
    • 1998
  • This study was designed to analysis the displacement and stress distribution of individual tooth by orthodontic force during distal on masse movement of the maxillary dentition. In this study, three dimensional finite element analysis was used. Author made the finite element model of maxillary teeth, periodontal ligament, alveolar bone and bracket with anatomic and physiologic characteristics on computer. Author analysed and evaluated the displacement and stress distribution of individual tooth when extraoral force, Class II intermaxillary elastics, ideal arch wire, MEAW and tip back bend were used for distal on masse movement of the maxillary dentition. These analyses were also applied in the case of the maxillary second molar were not extracted. Author compared the results of the cases which maxillary second molar were extracted or not. The results were expressed quantitatively and visually. Author obtained following results, 1. When anterior headgear was applied, the posterior translation, posterior tipping, and vertical displacement of teeth were produced more in the anterior segment of the dentition. 2. When Class II intermaxillary elastics were applied in the ideal arch wire, the teeth displacement were usually produced in the anterior segment. But when tip back bend were added in the ideal arch wire, the orthodontic force produced by elastics were transmitted to the posterior segment. As increasing the tip back bend, posterior translation and lingual tipping of anterior teeth were decreased, posterior translation and tipping displacement of posterior teeth were increased, and extrusion of anterior teeth by Class II elastics were decreased 3. When MDAW and Class II elastics were applied, the teeth movement were sir flu with the case of ideal arch wire and Class II elastics, but more small and uniform teeth displacement were produced Compared with the ideal arch wire, posterior tipping of the posterior segment were more produced than lingual tipping displacement of the anterior segment. 4. When the maxillary second molar without orthodontic appliance existed, the displacement of maxillary first molar were decreased.

  • PDF

Low-shrinking composites. Are they reliable for bonding orthodontic retainers?

  • Uysal, Tancan;Sakin, Caglar;AI-Qunaian, Talal
    • The korean journal of orthodontics
    • /
    • v.41 no.1
    • /
    • pp.51-58
    • /
    • 2011
  • Objective: To evaluate the shear bond strength (SBS), fracture mode, wire pull out (WPO) resistance and microleakage between low-shrinking and conventional composites used as a lingual retainer adhesive. Methods: A total of 120 human mandibular incisor teeth, extracted for periodontal reasons, were collected. Sixty of them were separated into two groups. To determine the SBS, either Transbond-LR (3M-Unitek) or Silorane (3M-Espe) was applied to the lingual surface of the teeth by packing the material into standard cylindrical plastic matrices (Ultradent) to simulate the lingual retainer bonding area. To test WPO resistance, 20 samples were prepared for each composite where the wire was embedded in the composite materialand cured. Then tensile stress was applied until failure of the composite occurred. The remaining 60 teeth were divided into two groups and multi-stranded 0.0215-inch diameter wire was bonded with the same composites. Microleakage was evaluated by the dye penetration method. Statistical analyses were performed by Wilcoxon, Pearson chi-square, and Mann-Whitney-U tests at p < 0.05 level. Results: The SBS and WPO results were not statistically significant between the two groups. Significant differences were found between the groups in terms of fracture mode (p < 0.001). Greater percentages of the fractures showed mix type failure (85%) for Silorane and adhesive (60%) for Transbond-LR. Microleakage values were lower in low-shrinking composite than the control and this difference was found to be statistically significant (p < 0.001). Conclusions: Low-shrinking composite produced sufficient SBS, WPO and microleakage values on the etched enamel surfaces, when used as a lingual retainer composite.