• Title/Summary/Keyword: Ormocer

Search Result 6, Processing Time 0.019 seconds

Shear bond strength and fracture patterns between Ormocer-based-resin and dentin (Ormocer-Based-Resin의 상아질에 대한 전단결합강도 및 파절 양상에 대한 연구)

  • Ahn, Shi-Hyun;Cho, In-Ho;Lim, Ju-Hwan;Lim, Heon-Song
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.4
    • /
    • pp.289-299
    • /
    • 2002
  • The bond strength is one of the most important factor in establishing long-term success of esthetic restorative dentistry. So, various restorative materials have been introduced to improve the esthetic and physical properties. Ormocer (organically modified ceramic) was developed as a result of such efforts. This study was performed to compare the shear bond strength of ormocer based adhesive with that of existing dentin adhesive. In this study $Admira^{(R)}$ and $Admira^{(R)}$ bond of the ormocer system are grouped together for ADM, Single $Bond^{(R)}$ which is an one-bottle adhesive and Z-250TM which is hybrid composite resin of BIS-GMA system for SIN, and $Definite^{(R)}$ of ormocer and Etch & $Prime^{(R)}$ 3.0 which is a self etching priming/ bonding agent for ETC. The results of this study were as follows. : (1) In the comparison of shear bond strength according to different adhesive system, shear bond strength was increased in the order of ETC group, SIN group, ADM group. There was no significant difference between ADM group and SIN group. However, there was a significant level of difference between ADM and ETC groups as well as SIN and ETC groups( p<0.05). (2) Examination by a scanning electron microscope showed a well established hybrid layer and resin tag in both ADM group and SIN group, while ETC group showed a minimal formation of the hybrid layer when compared with ADM and SIN groups. From the above results, it may be reasonable to start the clinical application of ormocer system, and it is recommended that ormocer system should be used along with an ormocer based adhesive because ormocer system showed the lower shear bond strength when it used with other existing self etching priming/bonding agent. The self etching priming/bonding agent showed relatively low shear bond strength, and it is considered that the further study should be needed.

Comparative study of surface roughness between several finishing and polishing procedures on ormocer-based composite resin and nanohybrid composite resin (복합 레진에서 마무리 방법에 따른 표면 거칠기 비교)

  • Jeong, Suk-In;Oh, Nam-Sik;Lee, Myung-Hyeon;Lee, En-Jung;Cho, Jung-Hyeon;Ji, Sung-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.105-115
    • /
    • 2008
  • Statement of problem: Proper finishing and polishing enhance both the esthetics and the longevity of restored teeth. Blade finishing technique would be suited for smoothing and finishing. Evaluation of this technique are necessary. Purpose: The purpose of this study was to evaluate the blade finishing and polishing procedures on the surface profile and roughness of ormocer-based composite resin and nanohybrid composite resin. Material and methods: The material included a ormocer-based composite resin ($Admira^{(R)}$ & $Admira^{(R)}$ Flow); a nanohybrid composite resin ($Grandio^{(R)}$ & $Grandio^{(R)}$ Flow). One hundred forty specimens of each group were prepared using a mylar strip and randomly divied into blade finishing and rubber polishing groups (n=10). The average surface roughness (Ra) in micrometers was measured and the surface profile was examined by scanning electron microscopy (SEM) (Magnification ${\times}$ 200). The data were analyzed by Mann-Whitney Test at 0.05 significance level. Conclusion: The results of this study indicated that the mylar strip produced the smoothest surface on all materials and among the finishing-polishing methods was not significanct difference (P>0.05). Ormocer-based flowable composite resin performedthe lowest variability in initial surface roughness among the tested materials.

SELECTED MECHANICAL PROPERTIES OF ORMOCER RESTORATIVE MATERIALS (Ormocer 계열 수복재의 물성에 관한 연구)

  • Lee, Dong-Soo;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.362-370
    • /
    • 2002
  • During the last two decades, many new filling materials and material groups have been developed. the number of available restoratives has increased dramatically, especially during the last 5 years. Ormocers are a new class of materials which are still under development with regard to dental applications. However, in the chemical literature these materials have been known for a long time and used for producing scratch resistant coatings on plastic spectacle lenses. It is a combination of inorganic and organic materials. 'Ormocer' is an abbreviation for 'Organically Modified Ceramics'. These compounds are also known in the literature as 'Ormosils' (organically modified silicates). Their chemistry is comparable to that of silicones and organic polymers. The purpose of this study was to determine of compressive strength and flexural strength of a ormocer (Admira) and to investigate the effects of water absorption in comparison with three composite resins(Z-100, Tetric Ceram, Surefil) and one compomer(Dyract AP). The following results were obtained ; 1. Admira had the lower compressive strength than Surefil, but no statistically difference with other materials at 1 day(p>0.05). 2. Admira had the lower flexural strength than all other materials at 1 day. From 2 days, Admits showed lower flexural strength than three composite resin(p<0.05). 3. There was not statistically significant difference of compressive and flexural strengths between hybrid composite resin group(Z-100, Tetric Ceram) and Packable resin group(Surefil) for experimental period(30 days)(p>0.05). 4. All five materials showed an increase in compressive and flexural strength till 2 days and showed a decrease from 7 days in water(p<0.05). 5. Each materials had the statistically similar behavior of compressive and flexural strengths over time(p>0.05).

  • PDF

A STUDY OF CONTRACTION SHRINKAGE OF COMPOSITE RESINS AND ORMOCERS WITH VARIOUS CURING TIMES (광조사 시간에 따른 복합레진과 Ormocer의 중합수축에 관한 연구)

  • Chung, Yeon-Chung;Min, Kyung-San;Lee, Hae-Hyoung;Cho, Kyung-Mo;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.326-333
    • /
    • 2003
  • Ormocer has organic-inorganic compound polymers. One of advantages of ormocer is reduced polymerization shrinkage. The purpose of this study was to compare the amount of contraction shrinkage of composite resins and ormocers. Additionally, the time of each material when there is no further change of contraction shrinkage was analysed. Four brands of composite resins (P-60. Surefil, Z-250 and Denfil) and two brands of ormocers (Definite and Admira) were used. 20 seconds, 40 seconds and 60 seconds of curing times were given. Contraction shrinkage of them were measured using a linometer for 80 seconds. The effect of material and curing time to contraction shrinkage at the time of 80 seconds was analysed by two-way ANOVA. The effect of time to contraction shrinkage was analysed by one-way ANOVA and the time when there was no further change of the contraction shrinkage was analysed. The results are as follows: 1. P-60, Definite, Z-250 and Denfil had no further change of contraction shrinkage from the time of 20 seconds, and Surefil and Admira had no further change of contraction shrinkage from the time of 10 seconds. 2. Statistical analysis revealed volumetric shrinkage varied among material (p<0,05). No significant difference of contraction shrinkage among different curing times was found, and there was no effect of interaction between materials and curing times to contraction shrinkage. 3. Definite and Admira showed the statistically same contraction shrinkage with those of Z-250 and P-60. which is higher than that of Surefil and lower than that of Denfil (p<0.05).

Low-Loss Multimode Waveguides Using Organic-Inorganic Hybrid Materials

  • Yoon, Keun-Byoung
    • Macromolecular Research
    • /
    • v.12 no.3
    • /
    • pp.290-292
    • /
    • 2004
  • Multimode channel waveguides were fabricated using a direct UV patterning technology from thick films deposited by the one-step dip-coating of an organic/inorganic hybrid material (ORMOCER(equation omitted). The core size of the covered ridge waveguide was 43${\times}$51 $\mu\textrm{m}$$^2$; the waveguides can be readily prepared for multimode applications by direct UV patterning. The waveguides exhibited smooth surface profiles and a low optical loss of 0.07 ㏈/cm at the most important wavelength (850nm) used for optical interconnects.

Temperature changes under demineralized dentin during polymerization of three resin-based restorative materials using QTH and LED units

  • Mousavinasab, Sayed-Mostafa;Khoroushi, Maryam;Moharreri, Mohammadreza;Atai, Mohammad
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.3
    • /
    • pp.155-163
    • /
    • 2014
  • Objectives: Light-curing of resin-based materials (RBMs) increases the pulp chamber temperature, with detrimental effects on the vital pulp. This in vitro study compared the temperature rise under demineralized human tooth dentin during light-curing and the degrees of conversion (DCs) of three different RBMs using quartz tungsten halogen (QTH) and light-emitting diode (LED) units (LCUs). Materials and Methods: Demineralized and non-demineralized dentin disks were prepared from 120 extracted human mandibular molars. The temperature rise under the dentin disks (n = 12) during the light-curing of three RBMs, i.e. an Ormocer-based composite resin (Ceram. X, Dentsply DeTrey), a low-shrinkage silorane-based composite (Filtek P90, 3M ESPE), and a giomer (Beautifil II, Shofu GmbH), was measured with a K-type thermocouple wire. The DCs of the materials were investigated using Fourier transform infrared spectroscopy. Results: The temperature rise under the demineralized dentin disks was higher than that under the non-demineralized dentin disks during the polymerization of all restorative materials (p < 0.05). Filtek P90 induced higher temperature rise during polymerization than Ceram.X and Beautifil II under demineralized dentin (p < 0.05). The temperature rise under demineralized dentin during Filtek P90 polymerization exceeded the threshold value ($5.5^{\circ}C$), with no significant differences between the DCs of the test materials (p > 0.05). Conclusions: Although there were no significant differences in the DCs, the temperature rise under demineralized dentin disks for the silorane-based composite was higher than that for dimethacrylate-based restorative materials, particularly with QTH LCU.