• 제목/요약/키워드: Ormocer

검색결과 6건 처리시간 0.029초

Ormocer-Based-Resin의 상아질에 대한 전단결합강도 및 파절 양상에 대한 연구 (Shear bond strength and fracture patterns between Ormocer-based-resin and dentin)

  • 안시현;조인호;임주환;임헌송
    • 구강회복응용과학지
    • /
    • 제18권4호
    • /
    • pp.289-299
    • /
    • 2002
  • The bond strength is one of the most important factor in establishing long-term success of esthetic restorative dentistry. So, various restorative materials have been introduced to improve the esthetic and physical properties. Ormocer (organically modified ceramic) was developed as a result of such efforts. This study was performed to compare the shear bond strength of ormocer based adhesive with that of existing dentin adhesive. In this study $Admira^{(R)}$ and $Admira^{(R)}$ bond of the ormocer system are grouped together for ADM, Single $Bond^{(R)}$ which is an one-bottle adhesive and Z-250TM which is hybrid composite resin of BIS-GMA system for SIN, and $Definite^{(R)}$ of ormocer and Etch & $Prime^{(R)}$ 3.0 which is a self etching priming/ bonding agent for ETC. The results of this study were as follows. : (1) In the comparison of shear bond strength according to different adhesive system, shear bond strength was increased in the order of ETC group, SIN group, ADM group. There was no significant difference between ADM group and SIN group. However, there was a significant level of difference between ADM and ETC groups as well as SIN and ETC groups( p<0.05). (2) Examination by a scanning electron microscope showed a well established hybrid layer and resin tag in both ADM group and SIN group, while ETC group showed a minimal formation of the hybrid layer when compared with ADM and SIN groups. From the above results, it may be reasonable to start the clinical application of ormocer system, and it is recommended that ormocer system should be used along with an ormocer based adhesive because ormocer system showed the lower shear bond strength when it used with other existing self etching priming/bonding agent. The self etching priming/bonding agent showed relatively low shear bond strength, and it is considered that the further study should be needed.

복합 레진에서 마무리 방법에 따른 표면 거칠기 비교 (Comparative study of surface roughness between several finishing and polishing procedures on ormocer-based composite resin and nanohybrid composite resin)

  • 정숙인;오남식;이명현;이은정;조정현;지성원
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.105-115
    • /
    • 2008
  • 전치부 영역에서의 복합 레진을 이용한 수복물의 표면은 착색과 치태 침착이 적어야 하며 치은 조직에 좋은 내성을 갖도록 평활해야 한다. 레진 수복 후 여러 마무리 방법중 blade를 이용한 방법은 치은과 접해있는 변연 부위의 불필요한 레진을 제거하고 마무리하는데 있어 치은 손상을 최소화하면서 간편하게 이용할 수 있는 방법이다. 본 연구의 목적은 현재 많이 사용되고 있는 nano-hybrid composite resin과 ormocer-based compostie resin 간의 여러 가지 마무리 방법에 있어 blade를 이용한 방법과 polishing을 시행한 경우의 표면 거칠기 및 nano계열과 ormocer 계열 복합 레진의 표면 특징을 비교하는 것으로 실험을 위해 가로 6mm, 세로 3mm, 높이 2mm의 금속 주형을 이용하여 레진 블록을 형성하고 대조군은 상면에 mylar strip을 위치시켜 광중합 하였으며, Ormocer - based composite resin ($Admira^{(R)}$)과 nanohybrid composite resin ($Grandio^{(R)}$)에서는 blade를 이용한 경우와 rubber polishing을 이용한 경우를 실험군으로 하였고, ormocer-based flowable composite resin ($Admira^{(R)}$ Flow)과 nanohybrid flowable composite resin ($Grandio^{(R)}$ Flow)에서는 blade를 이용한 경우, rubber polishing을 이용한 경우와 추가적으로 아무것도 시행하지 않은 경우를 실험군으로 하였다. 레진 블록의 표면은 profilometer 및 SEM을 이용하여 거칠기 및 조도를 비교하였으며 통계분석 하였다. 실험 결과 mylar stirp을 적용한 경우 Ra (${\mu}m$) 평균 값은 ormocer-base composite resin이 $0.25{\mu}m$, ormocer-based flowable resin $0.17{\mu}m$, nanohybrid composite resin $0.24{\mu}m$, nanohybrid flowable resin $0.18{\mu}m$ 였으며 blade를 적용한 경우 평균 값은 각각 $0.43{\mu}m$, $0.37{\mu}m$, $0.48{\mu}m$, $0.41{\mu}m$ 였다. 가장 낮은 Ra (${\mu}m$)은 mylar stirp을 적용한 시편에서 얻어졌으며, blade를 이용한 마무리 방법과 rubber polishing을 시행한 경우와 표면 거칠기 비교시 Ra (${\mu}m$)값에서 통계적으로 유의한 차이를 보이지 않았다 (P>0.05). Nanohybrid composite resin이 blade로 마무리하거나 rubber polishing후 ormocer-based composite resin보다 표면 거칠기 증가율이 좀 더 큰 것을 알 수 있었다. 이상의 결과는 blade를 이용한 마무리 방법이 다른 마무리 방법을 대체할 수 있을 것이라는 것을 보여주며, 이에 따라 본 실험 결과에 한정지어 볼 때 복합레진 수복후 마무리 방법으로 blade를 이용하여 시행하는 것이 적용가능 할 것이라 생각된다.

Ormocer 계열 수복재의 물성에 관한 연구 (SELECTED MECHANICAL PROPERTIES OF ORMOCER RESTORATIVE MATERIALS)

  • 이동수;정태성;김신
    • 대한소아치과학회지
    • /
    • 제29권3호
    • /
    • pp.362-370
    • /
    • 2002
  • 최근 20년간 다양한 종류의 심미 수복재가 개발되었고, 특히 지난 5년 동안에는 그 수에 있어서 극적인 증가추세를 보였다. 최근 들어, ormocer라는 새로운 종류의 광중합형 수복재료가 소개되었는데, 화학 분야에서는 이미 오래 전부터 알려져 있던 성분으로, 광학렌즈 등의 표면경화제로 이용되어 오다가 최근 치과용 수복재에 도입되었다. 'Ormocer' 란 'Organically Modified Ceramics'의 약자로 'Ormosils' (Organically Modified Silicates)로도 알려져 있다. 그러나, 이 새로운 수복재에 대한 연구는 아직 미흡한 실정이다. 본 연구에서는 서로 다른 계통의 광중합형 수복재들(Z-100, Surefil, Tetric Ceram, Dyract AP)과 ormocer(Admira)를 압축강도와 굴곡강도 측면에서 비교 평가하고, 구강내 환경과 유사한 조건에서 수분흡수가 그 물성에 미치는 영향을 평가할 목적으로 시도되어 다음과 같은 결과를 얻었다. 1. 1일 후에 측정한 Admira의 압축강도는 Surefil보다는 낮았으나, 다른 재료들과는 유의한 차이를 나타내지 않았다(p>0.05). 2. 1일 후에 측정한 Admira의 굴곡강도는 다른 4종의 재료에 비해서 낮았다(p<0.05). 2일부터는 3종의 복합레진에 비해서 낮았다(p<0.05). 3. 실험기간(30일) 중 hybrid composite resin군(Z-100, Tetric Ceram)과 packable resin(Surefil)군 간에는 압축강도와 굴곡강도에서 유의한 차이가 없었다(p>0.05). 4. 실험에 사용된 5종의 수복재 모두 압축강도와 굴곡강도가 2일까지 증가하다가 7일부터 감소하였다(p<0.05). 5. 각 재료의 시간에 따른 압축강도와 굴곡강도의 변화양상은 통계적으로 유사하였다(p>0.05).

  • PDF

광조사 시간에 따른 복합레진과 Ormocer의 중합수축에 관한 연구 (A STUDY OF CONTRACTION SHRINKAGE OF COMPOSITE RESINS AND ORMOCERS WITH VARIOUS CURING TIMES)

  • 정연정;민경산;이해형;조경모;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제28권4호
    • /
    • pp.326-333
    • /
    • 2003
  • Ormocer has organic-inorganic compound polymers. One of advantages of ormocer is reduced polymerization shrinkage. The purpose of this study was to compare the amount of contraction shrinkage of composite resins and ormocers. Additionally, the time of each material when there is no further change of contraction shrinkage was analysed. Four brands of composite resins (P-60. Surefil, Z-250 and Denfil) and two brands of ormocers (Definite and Admira) were used. 20 seconds, 40 seconds and 60 seconds of curing times were given. Contraction shrinkage of them were measured using a linometer for 80 seconds. The effect of material and curing time to contraction shrinkage at the time of 80 seconds was analysed by two-way ANOVA. The effect of time to contraction shrinkage was analysed by one-way ANOVA and the time when there was no further change of the contraction shrinkage was analysed. The results are as follows: 1. P-60, Definite, Z-250 and Denfil had no further change of contraction shrinkage from the time of 20 seconds, and Surefil and Admira had no further change of contraction shrinkage from the time of 10 seconds. 2. Statistical analysis revealed volumetric shrinkage varied among material (p<0,05). No significant difference of contraction shrinkage among different curing times was found, and there was no effect of interaction between materials and curing times to contraction shrinkage. 3. Definite and Admira showed the statistically same contraction shrinkage with those of Z-250 and P-60. which is higher than that of Surefil and lower than that of Denfil (p<0.05).

Low-Loss Multimode Waveguides Using Organic-Inorganic Hybrid Materials

  • Yoon, Keun-Byoung
    • Macromolecular Research
    • /
    • 제12권3호
    • /
    • pp.290-292
    • /
    • 2004
  • Multimode channel waveguides were fabricated using a direct UV patterning technology from thick films deposited by the one-step dip-coating of an organic/inorganic hybrid material (ORMOCER(equation omitted). The core size of the covered ridge waveguide was 43${\times}$51 $\mu\textrm{m}$$^2$; the waveguides can be readily prepared for multimode applications by direct UV patterning. The waveguides exhibited smooth surface profiles and a low optical loss of 0.07 ㏈/cm at the most important wavelength (850nm) used for optical interconnects.

Temperature changes under demineralized dentin during polymerization of three resin-based restorative materials using QTH and LED units

  • Mousavinasab, Sayed-Mostafa;Khoroushi, Maryam;Moharreri, Mohammadreza;Atai, Mohammad
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.155-163
    • /
    • 2014
  • Objectives: Light-curing of resin-based materials (RBMs) increases the pulp chamber temperature, with detrimental effects on the vital pulp. This in vitro study compared the temperature rise under demineralized human tooth dentin during light-curing and the degrees of conversion (DCs) of three different RBMs using quartz tungsten halogen (QTH) and light-emitting diode (LED) units (LCUs). Materials and Methods: Demineralized and non-demineralized dentin disks were prepared from 120 extracted human mandibular molars. The temperature rise under the dentin disks (n = 12) during the light-curing of three RBMs, i.e. an Ormocer-based composite resin (Ceram. X, Dentsply DeTrey), a low-shrinkage silorane-based composite (Filtek P90, 3M ESPE), and a giomer (Beautifil II, Shofu GmbH), was measured with a K-type thermocouple wire. The DCs of the materials were investigated using Fourier transform infrared spectroscopy. Results: The temperature rise under the demineralized dentin disks was higher than that under the non-demineralized dentin disks during the polymerization of all restorative materials (p < 0.05). Filtek P90 induced higher temperature rise during polymerization than Ceram.X and Beautifil II under demineralized dentin (p < 0.05). The temperature rise under demineralized dentin during Filtek P90 polymerization exceeded the threshold value ($5.5^{\circ}C$), with no significant differences between the DCs of the test materials (p > 0.05). Conclusions: Although there were no significant differences in the DCs, the temperature rise under demineralized dentin disks for the silorane-based composite was higher than that for dimethacrylate-based restorative materials, particularly with QTH LCU.