• Title/Summary/Keyword: Organs at risk

Search Result 141, Processing Time 0.025 seconds

Development of a Method for Improving the Electric Field Distribution in Patients Undergoing Tumor-Treating Fields Therapy

  • Sung, Jiwon;Seo, Jaehyeon;Jo, Yunhui;Yoon, Myonggeun;Hwang, Sang-Gu;Kim, Eun Ho
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1577-1583
    • /
    • 2018
  • Tumor-treating fields therapy involves placing pads onto the patient's skin to create a low- intensity (1 - 3 V/cm), intermediate frequency (100 - 300 kHz), alternating electric field to treat cancerous tumors. This new treatment modality has been approved by the Food and Drug Administration in the USA to treat patients with both newly diagnosed and recurrent glioblastoma. To deliver the prescribed electric field intensity to the tumor while minimizing exposure of organs at risk, we developed an optimization method for the electric field distribution in the body and compared the electric field distribution in the body before and after application of this optimization algorithm. To determine the electric field distribution in the body before optimization, we applied the same electric potential to all pairs of electric pads located on opposite sides of models. We subsequently adjusted the intensity of the electric field to each pair of pads to optimize the electric field distribution in the body, resulting in the prescribed electric field intensity to the tumor while minimizing electric fields at organs at risk. A comparison of the electric field distribution within the body before and after optimization showed that application of the optimization algorithm delivered a therapeutically effective electric field to the tumor while minimizing the average and the maximum field strength applied to organs at risk. Use of this optimization algorithm when planning tumor-treating fields therapy should maintain or increase the intensity of the electric field applied to the tumor while minimizing the intensity of the electric field applied to organs at risk. This would enhance the effectiveness of tumor-treating fields therapy while reducing dangerous side effects.

Dose Planning Study of Target Volume Coverage with Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma: Penang General Hospital Experience

  • Vincent Phua, Chee Ee;Tan, Boon Seang;Tan, Ai Lian;Eng, Kae Yann;Ng, Bong Seng;Ung, Ngie Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2243-2248
    • /
    • 2013
  • Background: To compare the dosimetric coverage of target volumes and organs at risk in the radical treatment of nasopharyngeal carcinoma (NPC) between intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3DCRT). Materials and Methods: Data from 10 consecutive patients treated with IMRT from June-October 2011 in Penang General Hospital were collected retrospectively for analysis. For each patient, dose volume histograms were generated for both the IMRT and 3DCRT plans using a total dose of 70Gy. Comparison of the plans was accomplished by comparing the target volume coverage (5 measures) and sparing of organs at risk (17 organs) for each patient using both IMRT and 3DCRT. The means of each comparison target volume coverage measures and organs at risk measures were obtained and tested for statistical significance using the paired Student t-test. Results: All 5 measures for target volume coverage showed marked dosimetric superiority of IMRT over 3DCRT. V70 and V66.5 for PTV70 showed an absolute improvement of 39.3% and 24.1% respectively. V59.4 and V56.4 for PTV59.4 showed advantages of 18.4% and 16.4%. Moreover, the mean PTV70 dose revealed a 5.1 Gy higher dose with IMRT. Only 4 out of 17 organs at risk showed statistically significant difference in their means which were clinically meaningful between the IMRT and 3DCRT techniques. IMRT was superior in sparing the spinal cord (less 5.8Gy), V30 of right parotid (less 14.3%) and V30 of the left parotid (less 13.1%). The V55 of the left cochlea was lower with 3DCRT (less 44.3%). Conclusions: IMRT is superior to 3DCRT due to its dosimetric advantage in target volume coverage while delivering acceptable doses to organs at risk. A total dose of 70Gy with IMRT should be considered as a standard of care for radical treatment of NPC.

Dosimetric comparison of axilla and groin radiotherapy techniques for high-risk and locally advanced skin cancer

  • Mattes, Malcolm D.;Zhou, Ying;Berry, Sean L.;Barker, Christopher A.
    • Radiation Oncology Journal
    • /
    • v.34 no.2
    • /
    • pp.145-155
    • /
    • 2016
  • Purpose: Radiation therapy targeting axilla and groin lymph nodes improves regional disease control in locally advanced and high-risk skin cancers. However, trials generally used conventional two-dimensional radiotherapy (2D-RT), contributing towards relatively high rates of side effects from treatment. The goal of this study is to determine if three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), or volumetric-modulated arc therapy (VMAT) may improve radiation delivery to the target while avoiding organs at risk in the clinical context of skin cancer regional nodal irradiation. Materials and Methods: Twenty patients with locally advanced/high-risk skin cancers underwent computed tomography simulation. The relevant axilla or groin planning target volumes and organs at risk were delineated using standard definitions. Paired t-tests were used to compare the mean values of several dose-volumetric parameters for each of the 4 techniques. Results: In the axilla, the largest improvement for 3D-CRT compared to 2D-RT was for homogeneity index (13.9 vs. 54.3), at the expense of higher lung $V_{20}$ (28.0% vs. 12.6%). In the groin, the largest improvements for 3D-CRT compared to 2D-RT were for anorectum $D_{max}$ (13.6 vs. 38.9 Gy), bowel $D_{200cc}$ (7.3 vs. 23.1 Gy), femur $D_{50}$ (34.6 vs. 57.2 Gy), and genitalia $D_{max}$ (37.6 vs. 51.1 Gy). IMRT had further improvements compared to 3D-CRT for humerus $D_{mean}$ (16.9 vs. 22.4 Gy), brachial plexus $D_5$ (57.4 vs. 61.3 Gy), bladder $D_5$ (26.8 vs. 36.5 Gy), and femur $D_{50}$ (18.7 vs. 34.6 Gy). Fewer differences were observed between IMRT and VMAT. Conclusion: Compared to 2D-RT and 3D-CRT, IMRT and VMAT had dosimetric advantages in the treatment of nodal regions of skin cancer patients.

Auto-segmentation of head and neck organs at risk in radiotherapy and its dependence on anatomic similarity

  • Ayyalusamy, Anantharaman;Vellaiyan, Subramani;Subramanian, Shanmuga;Ilamurugu, Arivarasan;Satpathy, Shyama;Nauman, Mohammed;Katta, Gowtham;Madineni, Aneesha
    • Radiation Oncology Journal
    • /
    • v.37 no.2
    • /
    • pp.134-142
    • /
    • 2019
  • Purpose: The aim is to study the dependence of deformable based auto-segmentation of head and neck organs-at-risks (OAR) on anatomy matching for a single atlas based system and generate an acceptable set of contours. Methods: A sample of ten patients in neutral neck position and three atlas sets consisting of ten patients each in different head and neck positions were utilized to generate three scenarios representing poor, average and perfect anatomy matching respectively and auto-segmentation was carried out for each scenario. Brainstem, larynx, mandible, cervical oesophagus, oral cavity, pharyngeal muscles, parotids, spinal cord, and trachea were the structures selected for the study. Automatic and oncologist reference contours were compared using the dice similarity index (DSI), Hausdroff distance and variation in the centre of mass (COM). Results: The mean DSI scores for brainstem was good irrespective of the anatomy matching scenarios. The scores for mandible, oral cavity, larynx, parotids, spinal cord, and trachea were unacceptable with poor matching but improved with enhanced bony matching whereas cervical oesophagus and pharyngeal muscles had less than acceptable scores for even perfect matching scenario. HD value and variation in COM decreased with better matching for all the structures. Conclusion: Improved anatomy matching resulted in better segmentation. At least a similar setup can help generate an acceptable set of automatic contours in systems employing single atlas method. Automatic contours from average matching scenario were acceptable for most structures. Importance should be given to head and neck position during atlas generation for a single atlas based system.

Multiple Primary Malignancies in Patients with Multiple Early Gastric Cancer

  • Kim, Dae Hoon;Kim, Su Mi;Choi, Min Gew;Sohn, Tae Sung;Bae, Jae Moon;Kim, Sung
    • Journal of Gastric Cancer
    • /
    • v.17 no.2
    • /
    • pp.154-161
    • /
    • 2017
  • Purpose: This study aimed to investigate the correlation between multiple early gastric cancer (MEGC) and multiple primary malignancies during the follow-up of patients with gastrectomy. Materials and Methods: The number of primary tumors detected in other organs after gastrectomy for early gastric cancer (EGC) has been increasing because of improved survival and surveillance programs. A total of 3,129 patients underwent radical gastrectomy for treatment of EGC at Samsung Medical Center from January 2000 to December 2005. Of these, 3,057 patients were selected and their medical records were retrospectively analyzed. Results: Among the 3,057 patients, 148 (4.8%) had MEGC, 84.5% were male, 57.4% were over 60 years old, 42.6% had a macroscopic type EGC IIb main lesion, and 68.9% had well-differentiated tumors with a significantly high incidence of MEGC. There were no differences between patients with solitary early gastric cancer (SEGC) and those with MEGC with regard to overall survival or recurrence-free survival, but MEGC was an independent risk factor for metachronous primary malignancies in other organs (P=0.004, hazard ratio [HR]=2.444). Conclusions: MEGC is not a risk factor for poor prognosis after curative gastrectomy, but it is a risk factor for metachronous primary malignancies in other organs during postoperative follow-up; therefore, careful surveillance is needed.

Evaluation of the Potential Human Health Risk Associated with the Microcystin Bioaccumulation in the Freshwater Fish from Lake Yeongcheon and Lake Daecheong (영천호와 대청호에서 담수어류의 microcystin 농축에 따른 인체 건강위해성 평가)

  • Lee, Kyung-Lak;Jheong, Weon-Hwa;Kang, Young-Hoon;Kim, Han-Soon
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.3
    • /
    • pp.331-339
    • /
    • 2009
  • This study evaluated the potential human health risk on the basis of the level of bioaccumulation and EDI (Estimated Daily Intake) of microcystin-LR, one of hepatotoxic, in organs, including liver, muscle, viscera and gill, of fish from Lake Yeongeheon and Lake Daecheong when the cyanobacterial water-blooms broke out. The result has confirmed that Carassius cuvieri from Lake Yeongcheon contains higher level of microcystin-LR in its organs including liver. In Lake Daecheong, omnivorous Hemibarbus labeo and phytoplanktivorous Carassius cuvieri have shown high microcystin-LR level on average, especially higher for viscera, and Carassius cuvieri has appeared to contain higher level of microcystin-LR in the liver and the gill compared with other species. As a result of comparison between EDI of microcystin-LR from each organs and TDI (Tolerable Daily Intake) of WHO (Chorus and Bartram, 1999) to evaluate human health risk, the EDI levels from Carassius cuvieri's organs except museles have exceeded TDI level at the both lakes. Consequently, the study has proved that microcystin was bioaccumulated in the various parts of fish, and it can be ingested by human resulting in risking human health. Continuous monitoring and reducing consumption of fish, especially Carassius cuvieri, during the cyanobacterial water-blooming period will be needed to protect human health.

Feasibility Assessment of Physical Factors of Rectal Cancer Short-Course Chemoradiotherapy with Delayed Surgery

  • Koo, Jihye;Chung, Mijoo;Chung, Weon Kuu;Jin, Sunsik;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.143-149
    • /
    • 2018
  • To verify the correlations between the clinical outcomes and physical factors of short-course chemoradiotherapy (SCRT) and long-course chemoradiotherapy (LCRT) with delayed surgery in patients with rectal cancer. Seventy-two patients with rectal cancer were enrolled in this study. Nineteen patients were treated with SCRT (25 Gy, 5 fractions) by intensity-modulated radiation therapy (IMRT), and 53 patients were treated with LCRT (50.4 Gy, 28 fractions) by three-dimensional conformal radiation therapy (3DCRT). Various physical factors for the target and organs at risk (OARs) were calculated to compare the clinical outcomes. The organ equivalent dose (OED) and lifetime attributable risk (LAR) of bowels and bladders were similar between the SCRT and LCRT groups, whereas the values of femurs were higher in the LCRT group. The equivalent uniform dose and normal tissue complication probability were higher in the LCRT than the SCRT group for most organs. Treatment complications, including anastomotic leakage, bowel adhesion, and hematologic toxicity, were not significantly different between SCRT and LCRT groups. CIs were $0.84{\pm}0.2$ and $0.61{\pm}0.1$ for SCRT and LCRT, respectively. The CVIs were $1.07{\pm}0.0$ and $1.10{\pm}0.1$, and the HIs were $0.09{\pm}0.0$ and $0.11{\pm}0.1$ for SCRT and LCRT, respectively. The sphincter-saving rates were 89.5% and 94.3% for SCRT and LCRT, respectively. The complete pathologic remission rates were 21.1% and 13.2%, and the down-staging rates were 47.4% and 26.4% for SCRT and LCRT, respectively. SCRT with IMRT is comparable to conventional LCRT in both physical indexes and clinical outcome. The preoperative SCRT, compensated by IMRT, is an effective and safe modality.

Successful Heart Transplantation Despite Rhesus Blood Type Mismatch: A Case Report

  • Ji Hong Kim;Yu-Rim Shin
    • Journal of Chest Surgery
    • /
    • v.57 no.2
    • /
    • pp.217-219
    • /
    • 2024
  • Matching for the rhesus (Rh) blood group is currently not taken into account in the organ allocation system. However, in Rh-mismatched transplantation, the primary concern is the potential for RhD-negative recipients to develop sensitization and produce anti-D antibodies if they receive a transfusion of RhD-positive blood. It is estimated that over 80% of RhD-negative recipients may experience Rh allosensitization when exposed to RhD-positive blood, although this occurrence is less common in recipients of solid organs. In theory, RhD-negative recipients who receive organs from RhD-positive donors are at risk of alloimmunization and the production of anti-D antibodies, which could complicate future blood product transfusions. However, our understanding of the impact of donor-recipient Rh mismatch on transplant outcomes, particularly in heart transplantation, is limited. We report a case of successful Rh-mismatched heart transplantation, which was effectively managed through the use of preoperative RhD immunoglobulin and plasmapheresis.

Classify the Acute Drug Intoxication Patients with Poisoning Severity Score(PSS) and Calculate the Optimal Cutoff Value of PSS, PSSsum to Predict Poor Prognosis (급성 약물 중독 환자에서 Poisoning Severity Score (PSS)를 이용한 중증도 분류와 중증도 분류에 있어 PSS 값과 PSSsum 값의 Optimal Cutoff Value)

  • Park, Hyun Woo;Park, Ha Young;Kim, Han Byeol;Park, Keon Woo;Lee, Sang Hun;Lee, Hyun Wook;Lee, Je Won;Hwang, Tae Sik
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.16 no.2
    • /
    • pp.75-85
    • /
    • 2018
  • Purpose: This study examined the Poisoning Severity Score (PSS) from acute poisoning patients, to determine the relationships among the PSS, PSSsum, the primary outcome (prolonged stay at the ER over 24 hours, general ward and ICU admission and the application of intubation and mechanical ventilator, and the administration of inotropes). Methods: A retrospective study was conducted through the EMR for 15 months. The PSS grade was classified according to the evidence of symptoms and signs. The differences in the primary outcomes between the PSS of when a single organ was damaged, and the PSS, PSSsum combined with the grade of when multiple organs were damaged, were studied. The cutoff value was calculated using the receiving operating characteristics (ROC) curve. Results: Of the 284 patients; 85 (29.9%) were men with a mean age of 48.8 years, and their average arrival time to the ER was $4.4{\pm}6.7\;hours$. The most frequently used drug was hypnotics. The number of patients with PSS grade 0, 1, 2, 3, and 4 was 17, 129, 122, 24, and one, respectively. No ICU admissions, application of intubation and mechanical ventilators, administration of inotropes were observed among the patients with PSS grades 0 and 1 but only on patients with PSS grades 2 to 4. At PSS, when separating the patients according to the number of damaged organs, 17 had no symptoms, 133 had one organ damaged, 75 had two organs damaged, 36 had three organs damaged, and 23 had four organs damaged. Significant differences were observed between increasing number of damaged organs and the primary outcome. Conclusion: Among the acute poisoning patients, the PSS was higher in severity when the grade was higher. The number of damaged organs and the primary outcome showed meaningful statistical differences. This study confirmed that when the patients' PSS>2 and PSSsum>5, the frequency of ICU admission was higher, and they were considered to be severe with an increased prescription risk of application of intubation and mechanical ventilator, and the administration of inotropes.

Adverse Effects of Air Pollution on Pulmonary Diseases

  • Ko, Ui Won;Kyung, Sun Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.85 no.4
    • /
    • pp.313-319
    • /
    • 2022
  • Environmental exposure to air pollution is known to have adverse effects on various organs. Air pollution has greater effects on the pulmonary system as the lungs are directly exposed to contaminants in the air. Here, we review the associations of air pollution with the development, morbidity, and mortality of pulmonary diseases. Short-and long-term exposure to air pollution have been shown to increase mortality risk even at concentrations below the current national guidelines. Ambient air pollution has been shown to be associated with lung cancer. Particularly long-term exposure to particulate matter with a diameter <2.5 ㎛ (PM2.5) has been reported to be associated with lung cancer even at low concentrations. In addition, exposure to air pollution has been shown to increase the incidence risk of chronic obstructive pulmonary disease (COPD) and has been correlated with exacerbation and mortality of COPD. Air pollution has also been linked to exacerbation, mortality, and development of asthma. Exposure to nitrogen dioxide (NO2) has been demonstrated to be related to increased mortality in patients with idiopathic pulmonary fibrosis. Additionally, air pollution increases the incidence of infectious diseases, such as pneumonia, bronchitis, and tuberculosis. Furthermore, emerging evidence supports a link between air pollution and coronavirus disease 2019 transmission, susceptibility, severity and mortality. In conclusion, the stringency of air quality guidelines should be increased and further therapeutic trials are required in patients at high risk of adverse health effects of air pollution.