• Title/Summary/Keyword: Organizing

Search Result 1,981, Processing Time 0.025 seconds

Design and Application of Gradient-descent-based Self-organizing Fuzzy Logic Controller (그래디언트 감소를 기반으로하는 자기구성 퍼지 제어기의 설계 및 응용)

  • 소상호;박동조
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.10a
    • /
    • pp.191-196
    • /
    • 1998
  • A new Fuzzy Logic Controller(FLC) called a Gradient-Descent Based Self-Organizing Controller is presented. The Self-Organizing Controller(SOC) has two inputs such as error and change of error, and updates control rules with monitoring a performance measure. There are many works in the SOC which concentrate on the self-organizing ability in control rule base, but have a few research on the performance measure which is akin to sliding mode control. With this procedure, we can get a robust performance measure on the SOC. To verify the perfomance of proposed controller, we have performed for the cart-pole system which is one of the well-known benchmark problem in the control literature.

  • PDF

A Self Creating and Organizing Neural Network (자기 분열 및 구조화 신경회로망)

  • 최두일;박상희
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.5
    • /
    • pp.533-540
    • /
    • 1992
  • The Self Creating and Organizing (SCO) is a new architecture and one of the unsupervized learning algorithm for the artificial neural network. SCO begins with only one output node which has a sufficiently wide response range, and the response ranges of all the nodes decrease automatically whether adapting the weights of existing node or creating a new node. It is compared to the Kohonen's Self Organizing Feature Map (SOFM). The results show that SCONN has lots of advantages over other competitive learning architecture.

  • PDF

A study on design of Self-Organizing Fuzzy Logic Controller (자기 조정 퍼지 로직 제어기 설계에 관한 연구)

  • Hur, Kwan;Lee, Sang-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.342-344
    • /
    • 1994
  • This paper presents a design technique of SOFLC(Self -Organizing Fuzzy Logic Controller). It is composed of three parts: FLC(Fuzzy Logic Controller) part, RPO (Repeat Parameter Organizing) part, and RTPO (Real Time Parameter Organizing) part. The FLC part is controlled by initial parameters ($a_1$, $a_2$, $a_3$, $b_1$, $b_2$, $b_3$) the RPO part improves parameters by evaluating the performance of control responses controlled by FLC, and the RTPO organizes the parameters for real time in order to have the same value of the control response($y_k$) and the target response($y_k\;^*$).

  • PDF

A Case of Secondary Organizing Pneumonia Associated with Endobronchial Actinomycosis (기관지 방선균증과 동반된 이차성 기질화 폐렴 1예)

  • Lee, Byoung Hoon;Lee, Ki-Deok;Kim, Sang Hoon;Woo, Jeong Joo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.3
    • /
    • pp.227-231
    • /
    • 2007
  • Several types of infection can cause organizing pneumonia when the inflammatory process remains active with the further organization of the intra-alveolar fibrinous exudates, despite the control of the infectious organism by antibiotics. We report a case of 37-year-old male with secondary organizing pneumonia associated with an endobronchial actinomycosis. The patient presented with a subacute cough, sputum and fever. Bronchial biopsy revealed sulfur granule to be consistent with the actinomycosis, and percutaneous needle biopsy revealed typical pattern of organizing pneumonia. The patient was treated with the appropriate antibiotics and corticosteroid. There was rapid improvement in the symptoms and radiological findings, and after six months of treatment, the corticosteroid dose was tapered off without a recurrence of the organizing pneumonia.

A Case of Bronchiolitis Obliterans Organizing Pneumonia After Thoracotomy (개흉술후 발생한 Bronchiolitis Obliterans Organizing Pneumonia 체험 1례)

  • 원경준;박종호;백희종;이향림;조재일
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.1040-1043
    • /
    • 1997
  • We report a patient who suffered from bronchiolitis obliterans organizing pneumonia(BOOP) after Ivor Lewis operation for esophageal cancer. The patient presented low grade fever, dry cough and mild dyspnea at day after operation. Chest roentgenograms and chest CT revealed bilateral patchy and infiltrative shadows. The respiratory symptoms worsened and respiratory failure developed with mild elevation of WBC count despite of conservative treatment. An open lung biopsy was done and the biopsy specimen showed bronchiolitis obliterans organizing pneumonia(BOOP). After several weeks of steroid therapy, there were marked clinical, physiological and roentgenographic improvements. Our experience suggests that BOOP may be one of the underlying pathology in a number of patients presenting with ARDS after thoracotomy. Since steroid therapy may improve survival in these patients, thoracic surgeons should heighten their index of suspicion for this entity. Early histologic diagnosis should be considered in patients with treatment-resistant ARDS after thoracotomy.

  • PDF

Adaptive Control of Super Peer Ration using Particle Swarm Optimization in Self-Organizing Super Peer Ring Search Scheme (자기 조직적 우수 피어 링 검색기법에서 입자 군집 최적화(PSO)를 이용한 적응적 우수 피어 비율 조절 기법)

  • Jang, Hyung-Gun;Han, Sae-Young;Park, Sung-Yong
    • The KIPS Transactions:PartA
    • /
    • v.13A no.6 s.103
    • /
    • pp.501-510
    • /
    • 2006
  • The self-organizing super peer ring P2P search scheme improves search performance of the existing unstructured peer-to-peer systems, in which super peers with high capacity constitute a ring structure and all peer in the system utilize the ring for publishing or querying their keys. In this paper, we further improves the performance of the self-organizing ring by adaptively changing its super peer ratio according to the status of the entire system. By using PSO, the optimized super peer ratio can be maintained within the system. Through simulations, we show that our self-organizing super peer ring optimized by PSO outperforms not only the fixed super peer ring but also the self-organizing super ring with fixed ratio in the aspect of query success rate.

Adaptation of the parameters of the physical layer of data transmission in self-organizing networks based on unmanned aerial vehicles

  • Surzhik, Dmitry I.;Kuzichkin, Oleg R.;Vasilyev, Gleb S.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.6
    • /
    • pp.23-28
    • /
    • 2021
  • The article discusses the features of adaptation of the parameters of the physical layer of data transmission in self-organizing networks based on unmanned aerial vehicles operating in the conditions of "smart cities". The concept of cities of this type is defined, the historical path of formation, the current state and prospects for further development in the aspect of transition to "smart cities" of the third generation are shown. Cities of this type are aimed at providing more comfortable and safe living conditions for citizens and autonomous automated work of all components of the urban economy. The perspective of the development of urban mobile automated technical means of infocommunications is shown, one of the leading directions of which is the creation and active use of wireless self-organizing networks based on unmanned aerial vehicles. The advantages of using small-sized unmanned aerial vehicles for organizing networks of this type are considered, as well as the range of tasks to be solved in the conditions of modern "smart cities". It is shown that for the transition to self-organizing networks in the conditions of "smart cities" of the third generation, it is necessary to ensure the adaptation of various levels of OSI network models to dynamically changing operating conditions, which is especially important for the physical layer. To maintain an acceptable level of the value of the bit error probability when transmitting command and telemetry data, it is proposed to adaptively change the coding rate depending on the signal-to-noise ratio at the receiver input (or on the number of channel decoder errors), and when transmitting payload data, it is also proposed to adaptively change the coding rate together with the choice of modulation methods that differ in energy and spectral efficiency. As options for the practical implementation of these solutions, it is proposed to use an approach based on the principles of neuro-fuzzy control, for which examples of determining the boundaries of theoretically achievable efficiency are given.

Symptom Questionnaire and Laboratory Findings in Subjects with Airflow Limitation: a Nation-wide Survey (기류 폐쇄(Airflow Limitation)의 유무와 호흡기 증상 및 검사실 성적에 관한 연구: 국가 단위 실태 조사)

  • Hwang, Yong Il;Kim, Young Chul;Lee, Jae Ho;Kang, Min Jong;Kim, Dong Gyu;Kim, Soo Ock;Jang, Tae Won;Lee, Min Ki;Ahn, Youngsoo;Yoo, Jee Hong;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.6
    • /
    • pp.480-485
    • /
    • 2007
  • Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation that is not fully reversible. COPD has systemic effects, such as skeletal muscle dysfunction and abnormal weight loss. It also has been suggested that COPD is related to other chronic disease, such as cardiovascular disease, osteoporosis, and anemia. The aim of this study was to evaluate a symptom questionnaire and laboratory findings in subjects with air flow limitation. Methods: We evaluated a symptom questionnaire and laboratory findings in subjects with airflow limitation detected by spirometry in conjunction with the Second Korean National Health and Nutrition Examination Survey. A total of 9,243 adults over the age of 18 were recruited. Among the adults, we finally analyzed 2,217 subjects who met the acceptability and repeatability criteria of spirometry, showed normal findings on chest radiography, and were older than 40 years of age. Results: There were 288 subjects with airflow limitation as determined by spirometry. The frequency of respiratory symptoms such as cough, sputum and wheezing were significantly higher in subjects with airflow limitation (p <0.01). Hemoglobin and hematocrit levels were higher in subjects with airflow limitation (hemoglobin level 13.98 mg/dL vs. 13.62 mg/dL, hematocrit 42.10% vs. 40.89%; p<0.01). The HDL cholesterol level was lower in subjects with airflow limitation (44.95 mg/dL vs. 45.60 mg/dL; p<0.01). There was no significant difference in the total cholesterol, triglyceride, blood urea nitrogen, creatinine, and fasting glucose levels. Conclusion: In subjects with airflow limitation, prevalence of respiratory symptoms was higher than in normal spirometry subjects and the levels of hemoglobin and the hematocrit were higher. The HDL cholesterol level was lower in subjects with airflow limitation.

Organizing Computer Files for the Library Collection (컴퓨터 파일 자료의 조직)

  • 조명희
    • Proceedings of the Korean Society for Information Management Conference
    • /
    • 1994.12a
    • /
    • pp.151-154
    • /
    • 1994
  • Historical background of computer files is briefly outlined. Descriptive examples of phisical area of computer files revealed in existing cataloging rules and manuals are examined and analyzed in terms of consistency identification and term standardization. An analysis of examples may provide the basis for enhancing organizing computer file.

  • PDF