• 제목/요약/키워드: Organic membrane

검색결과 854건 처리시간 0.031초

연수화 전처리를 적용한 한외여과에서 입자상 물질 및 자연유기물 막오염 (Particle and NOM Fouling in Ultrafiltration with Softening Pretreatment)

  • 권지향;데스몬드 롤러
    • 상하수도학회지
    • /
    • 제17권4호
    • /
    • pp.534-541
    • /
    • 2003
  • Membrane processes are now frequently considered for application in drinking water treatment. The biggest impediment for applying membrane processes is fouling that comes from mass flux (such as particle and organic matter) to the membrane surface and its pores due to convection flow through the membrane. Natural organic matter (NOM) has been reported as the most detrimental foulant. Some research also indicated that particles were often the dominant cause of fouling. Therefore, both NOM and particle fouling need to be examined to better understand fouling in ultrafiltration. Two waters from natural sources, Lake Austin water and Missouri River water, were selected. Both waters are relatively hard waters but has significantly different particle concentrations, which will elucidate effects of particles on membrane fouling. Precipitative softening is traditionally designed to remove hardness ions in hard waters but it can also remove particles and organic matter. Therefore, the integrated water treatment with softening and ultrafiltration is proposed as a promising option for hard waters. The three levels of softening were used to represent different degrees of pretreatment to ultrafiltration in terms of organic matter (i.e., NOM fouling) and precipitates (i.e., particle fouling by further precipitation). Results showed that natural particles in Missouri River water was detrimental foulants of ultrafiltration. As the levels of softening were increased, NOM and particle removal was increased, and thus fouling was decreased. Direct images of the surface of the membranes by scanning electron microscopy allowed observation of the different properties of particles caught in fibril networks of natural organic matter.

Dye removal from water using emulsion liquid membrane: Effect of alkane solvents on efficiency

  • Ghaemi, Negin;Darabi, Farzaneh;Falsafi, Monireh
    • Membrane and Water Treatment
    • /
    • 제10권5호
    • /
    • pp.361-372
    • /
    • 2019
  • Effect of different alkane based solvents on the stability of emulsion liquid membrane was investigated using normal alkanes (n-hexane, n-heptane, n-octane and n-decane) under various operating parameters of surfactant concentration, emulsification time, internal phase concentration, volume ratio of internal phase to organic phase, volume ratio of emulsion phase to external phase and stirring speed. Results of stability revealed that emulsion liquid membrane containing n-octane as solvent and span-80 (5 % (w/w)) as emulsifying agent presented the highest amount of emulsion stability (the lowest breakage) compared with other solvents; however, operating parameters (surfactant concentration (5% (w/w)), emulsification time (6 min), internal phase concentration (0.05 M), volume ratio of internal phase to organic phase (1/1), volume ratio of emulsion phase to external phase (1/5) and stirring speed (300 rpm)) were also influential on improving the stability (about 0.2% breakage) and on achieving the most stable emulsion. The membrane with the highest stability was employed to extract acridine orange with various concentrations (10, 20 and 40 ppm) from water. The emulsion liquid membrane prepared with n-octane as the best solvent almost removed 99.5% of acridine orange from water. Also, the prepared liquid membrane eliminated completely (100%) other cationic dyes (methylene blue, methyl violet and crystal violet) from water demonstrating the efficacy of prepared emulsion liquid membrane in treatment of dye polluted waters.

DMFC용 무기-유기 복합 전해질 막의 합성 (Synthesis of Inorganic-Organic Composite Electrolyte Membranes for DMFCs)

  • 김은형;윤국호;박성범;오명훈;김성진;박용일
    • 한국세라믹학회지
    • /
    • 제45권2호
    • /
    • pp.119-125
    • /
    • 2008
  • The FAS(Fluoroalkylsilane)/Nafion inorganic-organic composite electrolyte membrane was successfully fabricated through sol-gel method. The FAS having hydrophobic functional group and silanol ligands is impregnated in $Nafion^{(R)}$ membrane to reduce methanol crossover. The prepared FAS/Nafion inorganic-organic composite electrolyte membrane consist of the hydrophobic FAS-derived silicate nano-particles and $Nafion^{(R)}$ matrix showed decrease of methanol crossover and reduction of humidity dependence without large sacrifice of proton conductivity. The microstructural analysis of the composite membranes was performed using FESEM and FTIR. And the effect of the incorporation of the hydrophobic FAS-derived silicate nano-particles into $Nafion^{(R)}$ membrane was investigated via solvent uptake, membrane expansion rate, humidity dependency of proton conductivity and contact angle measurement.

Effects of hypochlorite exposure on morphology and trace organic contaminant rejection by NF/RO membranes

  • Simon, Alexander;Nghiem, Long D.
    • Membrane and Water Treatment
    • /
    • 제5권4호
    • /
    • pp.235-250
    • /
    • 2014
  • The impacts of membrane degradation due to chlorine attack on the rejection of inorganic salts and trace organic contaminants by nanofiltration (NF) and reverse osmosis (RO) membranes were investigated in this study. The rejection of trace contaminants was examined at environmentally relevant concentrations. Changes in the membrane surface morphology were observed as a result of chlorine exposure. A small increase in rejection was consistently observed with all four membranes selected in this study after being exposed to a low concentration of hypochlorite (100 ppm). In contrast, a higher concentration of hypochlorite (i.e., 2000 ppm) could be detrimental to the membrane separation capacity. Membranes with severe chlorine impact showed a considerable decrease in rejection over filtration time, possibly due to rearrangement of the polyamide chains under the influence of chlorine degradation and filtration pressure. The reported results indicate that loose NF membranes are more sensitive to chlorine exposure than RO membranes. The impact of hypochlorite exposure (both positive and negative) on rejection is dependent on the strength of the hypochlorite solution and is more significant for the neutral carbamazepine compound than the negatively charged sulfamethoxazole.

응집·한외여과 공정에서 응집조건 결정에 관한 연구 (Effect of Coagulation Condition on Coagulation/Ultrafiltration Membrane Process)

  • 문성용;이상협;김승현;문병현
    • 한국물환경학회지
    • /
    • 제21권4호
    • /
    • pp.379-384
    • /
    • 2005
  • In this research, coagulation was employed as the pretreatment for membrane process. The effective coagulation conditions were decided after the discussion of different coagulant doses and mixing conditions, etc. Raw water was taken from Nakdong River. The best operation occurred when G value was $230s^{-1}$ and the slow mixing lasted around 5 minutes at G value was $23s^{-1}$. To investigate the optimum coagulant dosage, the optimum organics removal was target as organic removal reduces membrane fouling effectively than particle removal. This result indicated that organics are more important causes than turbidity for membrane fouling. However, turbidity becomes an important factor after certain amount of organic matters is removed.

Production of Water for Injection by Membrane Process

  • Murakami, Daikichiro
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1996년도 제4회 하계분리막 Workshop (초순수 제조와 막분리 공정)
    • /
    • pp.177-189
    • /
    • 1996
  • Raverase osmosis or ultrafiltration systems have generally been regarded as hard to validate about WFI production. Though the Japanese and US Pharmacopoeias have allowed distillation and RO to be applied to WFI production process, only water stills, especially multiple effects have practically been employed for parenteral water production. On the other hand, the latest analysis has shown that even distillate contains such volatile organic matters as trihalomethanes and traces of heavy metals at a little higher concentration than supposed. The JP requires TOC to be monitored in WFI process based on RO or UF systems to control the concentration below 300ppb, but very few monographs or papers have so far been published about the concentrations of organic volatile matters in distillate. (See table 1-1) Therefore, this paper proposes a new applicable WFI systems based on the result of purified water analysis with some membranes used in the process. A well combined membrane system with other units could be expected to provide less amount of impurities in membrane-treated water than in distillate.

  • PDF