• Title/Summary/Keyword: Organ motion

Search Result 86, Processing Time 0.02 seconds

Analysis of changes in dose distribution due to respiration during IMRT

  • Shin, Jung-Suk;Shin, Eun-Hyuk;Han, Young-Yih;Ju, Sang-Gyu;Kim, Jin-Sung;Ahn, Sung-Hwan;Kim, Tae-Gyu;Jeong, Bae-Kwon;Park, Hee-Chul;Ahn, Young-Chan;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.29 no.3
    • /
    • pp.206-213
    • /
    • 2011
  • Purpose: Intensity modulated radiation therapy (IMRT) is a high precision therapy technique that can achieve a conformal dose distribution on a given target. However, organ motion induced by respiration can result in significant dosimetric error. Therefore, this study explores the dosimetric error that result from various patterns of respiration. Materials and Methods: Experiments were designed to deliver a treatment plan made for a real patient to an in-house developed motion phantom. The motion pattern; the amplitude and period as well as inhale-exhale period, could be controlled by in-house developed software. Dose distribution was measured using EDR2 film and analysis was performed by RIT113 software. Three respiratory patterns were generated for the purpose of this study; first the 'even inhale-exhale pattern', second the slightly long exhale pattern (0.35 seconds longer than inhale period) named 'general signal pattern', and third a 'long exhale pattern' (0.7 seconds longer than inhale period). One dimensional dose profile comparisons and gamma index analysis on 2 dimensions were performed. Results: In one-dimensional dose profile comparisons, 5% in the target and 30% dose difference at the boundary were observed in the long exhale pattern. The center of high dose region in the profile was shifted 1 mm to inhale (caudal) direction for the 'even inhale-exhale pattern', 2 mm and 5 mm shifts to exhale (cranial) direction were observed for 'slightly long exhale pattern' and 'long exhale pattern', respectively. The areas of gamma index >1 were 11.88 %, 15.11%, and 24.33% for 'even inhale-exhale pattern', 'general pattern', and 'long exhale pattern', respectively. The long exhale pattern showed largest errors. Conclusion: To reduce the dosimetric error due to respiratory motions, controlling patient's breathing to be closer to even inhaleexhale period is helpful with minimizing the motion amplitude.

Implementation of Externally Controllable Miniaturized Capsule for the Stimulation of Intestine (체외 제어 가능한 소화관 자극용 초소형 캡슐 구현)

  • Park, J.C.;Park, H.J.;Lee, J.W.;Song, B.S.;Lee, S.H.;Cho, J.H.
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.176-184
    • /
    • 2003
  • In this paper, a swallowable miniaturized capsule, which applicable for electrical stimulation of digestive organ to improve the motion of intestine in research purpose, is proposed and implemented. The developed capsule can be controlled for the behavior of the power on/off, amplitude and pulse rate for the patient stimulus, by internally equipped with miniaturized RF receiver that linked by the command of external transmitter. The experimental result of the implemented miniaturized capsule in the animal intestine show the ability of effective control for the stimulus parameters.

Performance Improvement of EMG-Pattern Recognition Using MFCC-HMM-GMM (MFCC-HMM-GMM을 이용한 근전도(EMG)신호 패턴인식의 성능 개선)

  • Choi, Heung-Ho;Kim, Jung-Ho;Kwon, Jang-Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.237-244
    • /
    • 2006
  • This study proposes an approach to the performance improvement of EMG(Electromyogram) pattern recognition. MFCC(Mel-Frequency Cepstral Coefficients)'s approach is molded after the characteristics of the human hearing organ. While it supplies the most typical feature in frequency domain, it should be reorganized to detect the features in EMG signal. And the dynamic aspects of EMG are important for a task, such as a continuous prosthetic control or various time length EMG signal recognition, which have not been successfully mastered by the most approaches. Thus, this paper proposes reorganized MFCC and HMM-GMM, which is adaptable for the dynamic features of the signal. Moreover, it requires an analysis on the most suitable system setting fur EMG pattern recognition. To meet the requirement, this study balanced the recognition-rate against the error-rates produced by the various settings when loaming based on the EMG data for each motion.

Vibration Measurements in the Mining Industry Applying the Software Install Application to the Kosovo Energy Corporation

  • Luzha, Ibush;Baftiu, Naim;Maloku, Betim;Qarkaxhija, Jusuf
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.8
    • /
    • pp.362-370
    • /
    • 2022
  • The assessment of specific impacts on the environment is a preventive measure for environmental protection which is based on the definition and proposal of measures that can prevent harmful effects, reduce or eliminate them. In the physical sense, vibration is the oscillating motion of an object with the effect of internal or external forces applied to it. People who touch a vibrating surface or object will feel these vibrations. In general, there are two types of vibration exposure. The first are the vibrations of the hands and arms transmitted by the held parts of tools or machinery. The second are whole-body vibrations transmitted from a seat or surface to a motorized car. The risk of injury to workers exposed to vibration varies depending on the size, frequency, type, duration of exposure, and organ affected. The purpose of this paper is to review the measurements of vibrations in the Kosovo Energy Corporation in the mine Sibovc Southwest, where coal with a rotary excavator is exploited and the evaluation of vibrations for working conditions for workers working in that environment and improving working conditions for the measurement of vibrations we have used the device Minimate DS 078, the purpose of such environmental impact assessment is to collect data and predict the harmful impacts on the environment, namely the impact on water, air, soil, life and health of as well as identify and propose measures that could prevent, reduce or eliminate altogether.

Effects of Gastrocnemius Stretching on α-Motor Neuron Excitability and Ankle Joint Active Dorsiflexion Range of Motion (비복근 스트레칭이 α-운동 신경원 흥분도와 족관절 능동 배측굴곡 가동범위에 미치는 영향)

  • Kim, Jong-Soon
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.9
    • /
    • pp.278-286
    • /
    • 2009
  • The aims of this study were to determined whether excitability of the $\alpha$-motor neuron is modulated by stretching and this changes were associated with flexibility of the muscle. In this study, $\alpha$-motor neuron excitability was measured by using the Hmax/Mmax ratio of the gastrocnemius H-reflex, and muscle flexibility was measured with the range of motion of the ankle dorsiflexion. The gastrocnemii of 10 healthy volunteers were stretched for 4 minutes(2 minutes stretching, 1 minute rest, and 2 minutes stretching) in each session by manual force. The Hmax/Mmax ratio of the H-reflex, as well as the range of motion of the ankle dosiflexion was measured through four different conditions: before stretching, as soon as after $1^{st}$ stretching, as soon as after $2^{nd}$ stretching and at 48 hours after $2^{nd}$ stretching. Excitability of the $\alpha$-motor neuron was decreased significantly after $1^{st}$ and $2^{nd}$ stretching(p<0.05). Furthermore, the range of the dorsiflexion was increased significantly after $1^{st}$ and $2^{nd}$ stretching(p<0.05). However, the excitability of the $\alpha$-motor neuron and range of the dorsiflexion at 48 hours after $2^{nd}$ stretching were not different from those of before stretching. These results suggest that reduced $\alpha$-motor neuron excitability of the gastrocnemius and increased flexibility of the ankle dorsiflexion would be followed by activation of the type III mechanoreceptor which around the ankle joint and the Golgi tendon organ in the gastrocnemius.

Dose Comparison Using Deformed Image Registration Method on Breast Cancer Radiotherapy (유방암 방사선치료에서 변형영상정합기법을 이용한 선량비교)

  • Won, Young Jin;Kim, Jong Won;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.57-62
    • /
    • 2017
  • The purpose of this study is to reconstruct the treatment plan by applying CBCT and DIR to dose changes according to the change of the patient's motion and breast shape in the large breast cancer patients and to compare the doses using TWF, FIF and IMRT. CT and CBCT were performed with MIM6 to create DIRCT and each treatment plan was made. The patient underwent computed tomography simulation in both prone and supine position. The homogeneity index (HI), conformity index (CI), coverage index (CVI) to the left breast as planning target volume (PTV) were determined and the doses to the lung, heart, and right breast as organ at risk (OAR) were compared by using dose-volume histogram and the unique property of each organ. The value of HI of the PTV breast increased in all treatment planning methods using DIRCT, and CVI and CI were decreased in the treatment planning methods using DIRCT.

An analysis on the Deconstructed Visage in Fashion Illustration - Based on the Deconstructed Visage of Francis Bacon's Painting - (패션 일러스트레이션에 나타난 얼굴해체 - 프란시스 베이컨 회화의 얼굴해체를 바탕으로 -)

  • Choi, Jung-Hwa;Choi, Yoo-Jin
    • Fashion & Textile Research Journal
    • /
    • v.15 no.6
    • /
    • pp.874-885
    • /
    • 2013
  • This study analyzes the visage in fashion illustration based on the deconstructed visage of Francis Bacon's paintings as well as analyzes fashion illustration works since 2000. The deconstructed visages in Francis Bacon's paintings are classified as blurring, elimination, distortion and division. The expressive methods and meanings in fashion illustration (according to categorization) are as follow. Blurring shows an ambiguous visage organ by the sweeping of the brush, removal of a boundary among the visage, body and clothes, gradation of organic line like visage shapes, stretching of the a plat combined to visage and fragmentation of visage. It represents an uncertainty of the fashion theme and image interpretation, impossibility of figure by ambiguity, fantastic effect and the induction of the uncanny. Elimination shows the background color's painting of a photo-montage, overlap of a cutting of visage's part and background of a plat, elimination of the visage and the elimination of eyes, nose or lips. It represents a weakened identity, the reinforcement of anonymity, creation of a violent image, and uncanny unfamiliarity. Distortion shows a distorted visage by free drawing, and unconscious drawing line, fluid digital body, combination of an unconscious curve, and an eccentric combination of the accidental. It represents the relief of specialty about realistic existence, hypothetical immateriality and fantasy. Division shows overlapped visages with different angles, the weird combination of a plural visage and different species and a plural breakaway of direction, and the position of several organs. It represents motion by power's trace, non-territory of species, ambiguity and uncertainty and the uncanny.

Dosimetric Effects of Air Pocket during Magnetic Resonance-Guided Adaptive Radiation Therapy for Pancreatic Cancer

  • Jin, Hyeongmin;Kim, Dong-Yun;Park, Jong Min;Kang, Hyun-Cheol;Chie, Eui Kyu;An, Hyun Joon
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.104-111
    • /
    • 2019
  • Purpose: Online magnetic resonance-guided adaptive radiotherapy (MRgART), an emerging technique, is used to address the change in anatomical structures, such as treatment target region, during the treatment period. However, the electron density map used for dose calculation differs from that for daily treatment, owing to the variation in organ location and, notably, air pockets. In this study, we evaluate the dosimetric effect of electron density override on air pockets during online ART for pancreatic cancer cases. Methods: Five pancreatic cancer patients, who were treated with MRgART at the Seoul National University Hospital, were enrolled in the study. Intensity modulated radiation therapy plans were generated for each patient with 60Co beams on a ViewrayTM system, with a 45 Gy prescription dose for stereotactic body radiation therapy. During the treatment, the electron density map was modified based on the daily MR image. We recalculated the dose distribution on the plan, and the dosimetric parameters were obtained from the dose volume histograms of the planning target volume (PTV) and organs at risk. Results: The average dose difference in the PTV was 0.86Gy, and the observed difference at the maximum dose was up to 2.07 Gy. The variation in air pockets during treatment resulted in an under- or overdose in the PTV. Conclusions: We recommend the re-contouring of the air pockets to deliver an accurate radiation dose to the target in MRgART, even though it is a time-consuming method.

A Parametric Image Enhancement Technique for Contrast-Enhanced Ultrasonography (조영증강 의료 초음파 진단에서 파라미터 영상의 개선 기법)

  • Kim, Ho Joon;Gwak, Seong Hoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.6
    • /
    • pp.231-236
    • /
    • 2014
  • The transit time of contrast agents and the parameters of time-intensity curves in ultrasonography are important factors to diagnose various diseases of a digestive organ. We have implemented an automatic parametric imaging method to overcome the difficulty of the diagnosis by naked eyes. However, the micro-bubble noise and the respiratory motions may degrade the reliability of the parameter images. In this paper, we introduce an optimization technique based on MRF(Markov Random Field) model to enhance the quality of the parameter images, and present an image tracking algorithm to compensate the image distortion by respiratory motions. A method to extract the respiration periods from the ultrasound image sequence has been developed. We have implemented the ROI(Region of Interest) tracking algorithm using the dynamic weights and a momentum factor based on these periods. An energy function is defined for the Gibbs sampler of the image enhancement method. Through the experiments using the data to diagnose liver lesions, we have shown that the proposed method improves the quality of the parametric images.

The role of surgical clips in the evaluation of interfractional uncertainty for treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy

  • Bae, Jin Suk;Kim, Dong Hyun;Kim, Won Taek;Kim, Yong Ho;Park, Dahl;Ki, Yong Kan
    • Radiation Oncology Journal
    • /
    • v.35 no.1
    • /
    • pp.65-70
    • /
    • 2017
  • Purpose: To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). Methods and Materials: Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip_p, ${\leq}2cm$) and 3 distal clips (clip_d, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions. Results: The translocation of clip was well correlated with diaphragm movement in 90.4% (190/210) of all images. The clip position errors greater than 5 mm were observed in 26.0% in SI, 1.8% in AP, and 5.4% in RL directions, respectively. Moreover, the clip position errors greater than 10 mm were observed in 1.9% in SI, 0.2% in AP, and 0.2% in RL directions, despite respiratory control. Conclusion: Quantitative analysis of surgical clip displacement reflect respiratory motion, setup errors and postoperative change of intraabdominal organ position. Furthermore, position of clips is distinguished easily in verification images. The identification of the surgical clip position may lead to a significant improvement in the accuracy of upper abdominal radiation therapy.