• Title/Summary/Keyword: Organ Size

Search Result 258, Processing Time 0.032 seconds

Development of specific organ-targeting drug delivery system 1

  • Kim, Chong-Kook;Jeong, Eun-Ju;Yang, Ji-Sun;Kim, Seung-Hwan;Kim, Yang-Bae
    • Archives of Pharmacal Research
    • /
    • v.8 no.3
    • /
    • pp.159-168
    • /
    • 1985
  • In attempt to develop a drug delivery system using serum albumin microspheres, bovine serum albumin microspheres containing antitumor agent, cytarabine, were prepared. The shape, surface characteristics, size distribution, behavior of in vitro distribution, drug release behaior, and degradation of albumin microspheres in animal liver tissue homogenate and proteolytic enzyme were investigated. The shape of albumin microspheres was spherical and the surface was smooth and compact. The size distribution of the albumin microspheres was affected by dispersion forces during emulsification and albumin concentration. Distribution of albumin mirospheres after intravenous administration in rabbit was achieved immediately. In vitro, albumin microsphere matrix was so hard that it retained most of cytarabine except initial burst during the first 10 minutes, and the level of drug release during the initial burst was affected by heating temperature, drug/albumin concentration ratio and size distribution. After drug release test, the morphology of albumin micropheres was not changed. Albumin microsphere matrix was degraded by the rabbit liver tissue homogenate and proteolytic enzyme. The degree of degradation was affected by heating temperature.

  • PDF

Effect of Field Size on the Clinical Exposure Index for Lumbar Spine X-ray Examination (노출지수를 이용한 요추 X선 촬영의 조사야 유효성 평가)

  • Park, Hyemin;Yoon, Yongsu;Kim, Jungsu;Jeong, Hoiwoun
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.183-187
    • /
    • 2021
  • The field size of the lumbar spine X-ray examination, which belongs to the most frequent examination in general radiography, is 5 times wider than the width of the lumbar spine. Exposure index (EI) as per International Electrotechnical Commission has a proportional relationship with the dose incident on the image receptor for clinical protocols in addition to RQA5, which is a calibration beam quality. In this study, the effectiveness of the set field size was evaluated through the change of EI according to the size of field during lumbar spine X-ray examinations. Lumbar anterior-posterior and lateral examinations was performed using a whole-body phantom, and the national average exposure conditions of Korea investigated in 2017 were introduced for the X-ray exposure. As a result of comparing the EI displayed on the console of digital radiography system for the three field size in ① 18 × 36 cm2 ② 25 × 36 cm2 ③ 36 × 36 cm2, the EI values showed a tendency to increase as the field size increased. Since the patient dose, such as organ dose around the lumbar spine, increases as the field size becomes larger, thus, if the EI obtained from the field size at a level that does not interfere with diagnosis is set as a reference, the effectiveness of the field size can be evaluated through the EI displayed on the console when the lumbar spine X-ray examination is conducted.

Physics of Yin-Yang & Five Element and its General Application to Constitution & Psychology

  • Jang, Dong-Soon;Shin, Mi-Soo;Paeck, Young-Soo
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.342-351
    • /
    • 2000
  • The paper is concerned about the discovery of new physics of the old oriental philosophy of the yin-Yang '||'&'||' five elements. the physical properties of Five Elements are defined, similarly as in thermodynamics, as five different characteristic state in a cyclic system of nature or a human body. Wood is defined as "warm and soft", Fire as "hot and dispersive", Earth as "agglomerating and sticky", Metal as "tensile and crystallizing", and Water as "cool and slippery" state, respectively. Based on the physics of Five Elements and Qi channel theory, five different constitution classification s are made according to the shape of human face, such as long, inverse triangle, circle, square, and triangle geometry, respectively.Since the constitution implies the relative size or strength of 5 major organs, this theory can be applies successfully to the prediction of the susceptibility to specific diseases as well as the analyses of personal character such as emotion and sensibility. The specific character is analyzed with four different aspects; that is, the first and second are caused by the positive and negative side of the strongest organ, the third character by determined the weakest organ, and finally the fourth by the abnormal psychology due to serious illness.bnormal psychology due to serious illness.

  • PDF

Embryo and Fetal Developmental Toxicity Study on Gamma-Irradiated Korean Ginseng in Rats (방사선 조사 인삼이 랫드의 기형유발에 미치는 영향에 관한 연구)

  • 박귀례;신재호;김판기;이유미;장성재
    • Toxicological Research
    • /
    • v.17 no.1
    • /
    • pp.27-32
    • /
    • 2001
  • Korean ginseng products have been fumigated with ethylene oxide (EO) for sterilization and prolongation of storage periods. However, there had been controversies indicating that consumption of EO treated foods might cause harmful effects in human. In Korea, the use EO gas for food treatment was banned in 1991. Since then, irradiation technique has been developed as an alternative. This study was carried out to evaluate the safety of irradiated ginseng on embryo and fetal developmental toxicity effects in rats. Either EO gas fumigated or $\gamma$-irradiated ginseng was administered to pregnant Wistar rats by oral gavage from gestational day 7 to 17. The amount of irradiation used in this study was 5, 10 and 30 kGy, respectively. There were no treatment related changes of dams in deaths, clinical signs, food consumption and body/organ weight. No treatment related changes in implantation ratio, litter size, sex ratio and body/organ weight of fetuses were observed. Also, no F1fetuses with external, visceral, head and skeletal mal-formation were observed. The results of this study showed that $\gamma$-irradiated ginseng, up to 30 kGy, has no adverse effects on fetal development of rats.

  • PDF

A Review of Organ Dose Calculation Methods and Tools for Patients Undergoing Diagnostic Nuclear Medicine Procedures

  • Choonsik Lee
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.1-18
    • /
    • 2024
  • Exponential growth has been observed in nuclear medicine procedures worldwide in the past decades. The considerable increase is attributed to the advance of positron emission tomography and single photon emission computed tomography, as well as the introduction of new radiopharmaceuticals. Although nuclear medicine procedures provide undisputable diagnostic and therapeutic benefits to patients, the substantial increase in radiation exposure to nuclear medicine patients raises concerns about potential adverse health effects and calls for the urgent need to monitor exposure levels. In the current article, model-based internal dosimetry methods were reviewed, focusing on Medical Internal Radiation Dose (MIRD) formalism, biokinetic data, human anatomy models (stylized, voxel, and hybrid computational human phantoms), and energy spectrum data of radionuclides. Key results from many articles on nuclear medicine dosimetry and comparisons of dosimetry quantities based on different types of human anatomy models were summarized. Key characteristics of seven model-based dose calculation tools were tabulated and discussed, including dose quantities, computational human phantoms used for dose calculations, decay data for radionuclides, biokinetic data, and user interface. Lastly, future research needs in nuclear medicine dosimetry were discussed. Model-based internal dosimetry methods were reviewed focusing on MIRD formalism, biokinetic data, human anatomy models, and energy spectrum data of radionuclides. Future research should focus on updating biokinetic data, revising energy transfer quantities for alimentary and gastrointestinal tracts, accounting for body size in nuclear medicine dosimetry, and recalculating dose coefficients based on the latest biokinetic and energy transfer data.

Image-based Absorbed Dosimetry of Radioisotope (영상기반 방사성동위원소 흡수선량 평가)

  • Park, Yong Sung;Lee, Yong Jin;Kim, Wook;Ji, Young Hoon;Kim, Kum Bae;Kang, Joo Hyun;Lim, Sang Moo;Woo, Sang-Keun
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.86-92
    • /
    • 2016
  • An absorbed dose calculation method using a digital phantom is implemented in normal organs. This method cannot be employed for calculating the absorbed dose of tumor. In this study, we measure the S-value for calculating the absorbed dose of each organ and tumor. We inject a radioisotope into a torso phantom and perform Monte Carlo simulation based on the CT data. The torso phantom has lung, liver, spinal, cylinder, and tumor simulated using a spherical phantom. The radioactivity of the actual absorbed dose is measured using the injected dose of the radioisotope, which is Cu-64 73.85 MBq, and detected using a glass dosimeter in the torso phantom. To perform the Monte Carlo simulation, the information on each organ and tumor acquired using the PET/CT and CT data provides anatomical information. The anatomical information is offered above mean value and manually segmented for each organ and tumor. The residence time of the radioisotope in each organ and tumor is calculated using the time activity curve of Cu-64 radioactivity. The S-values of each organ and tumor are calculated based on the Monte Carlo simulation data using the spatial coordinate, voxel size, and density information. The absorbed dose is evaluated using that obtained through the Monte Carlo simulation and the S-value and the residence time in each organ and tumor. The absorbed dose in liver, tumor1, and tumor2 is 4.52E-02, 4.61E-02, and 5.98E-02 mGy/MBq, respectively. The difference in the absorbed dose measured using the glass dosimeter and that obtained through the Monte Carlo simulation data is within 12.3%. The result of this study is that the absorbed dose obtained using an image can evaluate each difference region and size of a region of interest.

Effect of Bisphenol A Administration on Reproductive Toxicant of Dam and Sex Ratio of Pups in Pregnant Mice (임신중인 생쥐에 Bisphenol A 투여가 모체의 생식독성과 태아의 성비에 미치는 영향)

  • Park Dong-Heon;Jang Hyun-Yong;Kim Choung-Ik;Cheong Hee-Tae;Park Coon-Keun;Yang Boo-Keun
    • Toxicological Research
    • /
    • v.21 no.2
    • /
    • pp.161-165
    • /
    • 2005
  • Bisphenol A (SPA), a environmental endocrine disruptor, is considered to bind to estrogen receptors and to regulate the expressions of estrogen responsive genes. This study was to evaluate the effect of SPA administration on body weight, sex ratio and litter size on 18 days in prenatal periods, the effect of reproductive organ weight and blood hematological values on 24 days postpartum in pregnant mice. The female mice was administrated to low doses of SPA (0, 0.05, 0.5 and 5.0 mg/kg B.W.) by intraperitoneal injection in gestation days $0\~15$ with 5 times at 3 days interval. The maternal body weight, litter size and sex ratios were similar to in all experimental groups, but body weights of male and female offspring was significantly lower in 5.0mg SPA group when compared to any other groups (P<0.05). No treatment-related effects on body weight, ovary weight and blood hematological values were observed in dams on 24 days after delivery. The uterine weight in 5.0mg SPA group was slightly higher than those of any other groups, but not significantly difference. The histological evaluation of ovary in dam mice on 24 days after dilivery was not difference in all experimental groups, but the endometriosis of uterus in dam mice were significantly increased in 0.5mg SPA group when compared to control group. These results indicates that low concentration of SPA should not be considered as a selective reproductive toxicant.

Evaluation of Normal Abdominal Organs by Diagnostic Imaging in the Premature Miniature Pig (미성숙 미니돼지에서 방사선과 초음파를 이용한 복부장기의 평가)

  • Chang, Jin-Hwa;Jung, Joo-Hyun;Oh, Sun-Kyoung;Choi, Min-Cheol
    • Journal of Life Science
    • /
    • v.19 no.3
    • /
    • pp.417-421
    • /
    • 2009
  • This report describes the normal radiographic and ultrasonographic morphological features of premature minipigs at 4, 8, 12 and 20 weeks of age. Radiographic examination is a simple diagnostic method used to identify the general morphologic state of major organs and their adjacent structures, and to assess the presence of abnormalities. The parameters for evaluation in plain abdominal radiographs are the degree of diffuse serosal margin details, extent of visualization of each organ, their size, shape, and contour, locations of main organs - such as the liver, stomach, spleen, kidneys, urinary bladder - the distribution of the intestines, and assessment of the retroperitoneal space and its contents. Ultrasonographic examinations are used to investigate their internal condition. The parameters for evaluation in abdominal ultrasonography are echogenicity, echotexture, and size and shape of the main organs such as the liver, spleen, kidney, urinary bladder and gastrointestinal tract. Minipigs had similar findings compared to dogs or cats.

Effect of Scatter ray in Outside Telecobalt-60 Field Size (코발트-60 조사야 밖의 장기에 미치는 2차선의 영향)

  • Kim, You-Hyun;Kim, Young-Whan
    • Journal of radiological science and technology
    • /
    • v.11 no.2
    • /
    • pp.65-71
    • /
    • 1988
  • Radiation dose outside the radiotherapy treatment field can be significant and therefore is of clinical interest estimating organ dose. We have made measurements of dose at distances up to 70 cm from the central axis of $5{\times}5$, $10{\times}10$, $15{\times}15$, and $25{\times}25$ cm radiation fields of Co-60 ${\gamma}-ray$, at 5 cm depth in water. Contributions to the total secondary radiation dose from water scatter, machine (collimator) scatter and leakage radiation have been seperated. We have found that the component of dose from water scatter can be described by simple exponential function of distance from the central axis of the radiation field for all field sizes. Machine scatter contributes 20 to 60% of the total secondary dose depending on field size and distance from the field. Leakage radiation contributes very little dose, but becomes the dominant componant at distance beyond 40 cm from the central axis. Then, wedges can cause a factor 2 to 3 increase in dose at any point outside the field compared with the dose when no wedge is used. Adding blocks to a treatment field can cause an increase in dose at points outside the field, but the effect is much smaller than the effect of a wedge. From the results of these measurements, doses to selected organs outside the field for specified treatment geometries were estimated, and the potential for reducing these organ doses by additional shielding was assessed.

  • PDF

The Rice FON1 Gene Controls Vegetative and Reproductive Development by Regulating Shoot Apical Meristem Size

  • Moon, Sunok;Jung, Ki-Hong;Lee, Do-Eun;Lee, Dong-Yeon;Lee, Jinwon;An, Kyungsook;Kang, Hong-Gyu;An, Gynheung
    • Molecules and Cells
    • /
    • v.21 no.1
    • /
    • pp.147-152
    • /
    • 2006
  • Most plant organs develop from meristems. Rice FON1, which is an ortholog of Clv1, regulates stem cell proliferation and organ initiation. The point mutations, fon1-1 and fon1-2, disrupt meristem balance, resulting in alteration of floral organ numbers and the architecture of primary rachis branches. In this study, we identified two knockout alleles, fon1-3 and fon1-4, generated by T-DNA and Tos17 insertion, respectively. Unlike the previously isolated point mutants, the null mutants have alterations not only of the reproductive organs but also of vegetative tissues, producing fewer tillers and secondary rachis branches. The mutant plants are semi-dwarfs due to delayed leaf emergence, and leaf senescence is delayed. SEM analysis showed that the shoot apical meristems of fon1-3 mutants are enlarged. These results indicate that FON1 controls vegetative as well as reproductive development by regulating meristem size.