• 제목/요약/키워드: Oral implant

검색결과 1,697건 처리시간 0.025초

Bone cement grafting increases implant primary stability in circumferential cortical bone defects

  • Shin, Seung-Yun;Shin, Seung-Il;Kye, Seung-Beom;Chang, Seok-Woo;Hong, Jongrak;Paeng, Jun-Young;Yang, Seung-Min
    • Journal of Periodontal and Implant Science
    • /
    • 제45권1호
    • /
    • pp.30-35
    • /
    • 2015
  • Purpose: Implant beds with an insufficient amount of cortical bone or a loss of cortical bone can result in the initial instability of a dental implant. Thus, the objective of this study was to evaluate the effect of bone cement grafting on implant initial stability in areas with insufficient cortical bone. Methods: Two different circumferential defect depths (2.5 mm and 5 mm) and a control (no defect) were prepared in six bovine rib bones. Fourteen implants of the same type and size ($4mm{\pm}10mm$) were placed in each group. The thickness of the cortical bone was measured for each defect. After the implant stability quotient (ISQ) values were measured three times in four different directions, bone cement was grafted to increase the primary stability of the otherwise unstable implant. After grafting, the ISQ values were measured again. Results: As defect depth increased, the ISQ value decreased. In the controls, the ISQ value was $85.45{\pm}3.36$ ($mean{\pm}standard$ deviation). In circumferential 2.5-mm and 5-mm defect groups, the ISQ values were $69.42{\pm}7.06$ and $57.43{\pm}6.87$, respectively, before grafting. These three values were significantly different (P<0.001). After grafting the bone cement, the ISQ values significantly increased to $73.72{\pm}8.00$ and $67.88{\pm}10.09$ in the 2.5-mm and 5.0-mm defect groups, respectively (P<0.05 and P<0.001). The ISQ value increased to more than double that before grafting in the circumferential 5-mm defect group. The ISQ values did not significantly differ when measured in any of the four directions. Conclusions: The use of bone cement remarkably increased the stability of the implant that otherwise had an insufficient level of stability at placement, which was caused by insufficient cortical bone volume.

Aplastic anemia and dental implant rehabilitation: a clinical trial

  • Kim, Jun-Hwa;Shet, Uttom Kumar;Kim, Byeong-Guk;Kim, Myung-In;Kook, Min-Suk;Oh, Hee-Kyun;Ryu, Sun-Youl;Park, Hong-Ju;Jung, Seunggon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권5호
    • /
    • pp.265-269
    • /
    • 2015
  • The purpose of this study was to investigate implant-supported restoration as a technique for restoring missing teeth in patients with aplastic anemia. Recurrent bleeding from wound sites leads to persistent release of iron in the tissue. Excessive iron in tissue is related to clinical findings, including fibrosis, poor wound healing, and high level of angiogenesis, which are possible etiological factors of reduced osseointegration. A 44-year-old female patient with aplastic anemia was treated with multiple endosseous implants throughout the mandible and in the posterior region of the maxilla. After 14 implants were placed, radiological and clinical parameters were assessed during the follow-up period. Marginal bone did not change significantly during the follow-up period. The fine trabecular bone in intimate contact and enclosing the implant fixture was sufficient for successful osseointegration. None of the 14 implants were associated with compilations during the seven-year experimental period. This study suggests that dental implant procedures are a safe and reliable treatment option for restoration of missing dentition in patients with aplastic anemia.

Fractures of implant fixtures: a retrospective clinical study

  • Yu, Han-Chang;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.13.1-13.6
    • /
    • 2020
  • Background: The aim of this study was to evaluate the factors that may affect implant fixture fractures. Methods: Patients who experienced implant fixture removal at Seoul National University Bundang Hospital from 2007 to 2015 due to implant fixture fracture were included. Implant/crown ratio, time of implant fracture, clinical symptoms before implant fracture, treatment of fractured implants, and the success and survival rate of the replaced implants were evaluated retrospectively. Results: Thirteen implants were fractured in 12 patients. Patient mean age at the time of fracture was 59.3 years. Of the 13 implants, 7 implants were placed at our hospital, and 6 were placed at a local clinic. The mean crown/implant ratio was 0.83:1. The clinical symptoms before fracture were screw loosening in five implants, marginal bone loss in five implants, and the presence of peri-implant diseases in five implants. All the fractured implants were removed, and 12 out of the 13 sites were re-implanted. Parafunctions were observed in two patients: one with bruxism and one with attrition due to a strong chewing habit. Conclusions: Several clinical symptoms before the fracture of an implant can predict implant fixture failure. Therefore, if these clinical symptoms are observed, appropriate treatments can be taken before more serious complications result.

기능적 부하 후 "Short Implant" 주변의 골 흡수에 대한 방사선학적 연구 (Study on the radiographic evaluation of marginal bone loss around short-length implant after functional loading)

  • 박영주;남정훈;노경록;연병무;유우근;이정원;안장훈;강태인;박미희
    • 대한치과의사협회지
    • /
    • 제48권8호
    • /
    • pp.615-620
    • /
    • 2010
  • Purpose: The short dental implant is considered as possible solution in the alveolar bone height deficient cases. The aim of this study was to evaluate clinical availability of short implants by measuring the marginal bone loss of short length implants and comparing with that of conventional length implants. Materials and Methods: The groups were composed of patients who had received at least one implant. The samples of this study were selected from patients who with functional loading after prosthetic treatment for 1 year follow up period. The implants with a length of 5.7 mm and 6mm were considered short. (Bicon Dental implants, USA). The experiment group was composed of $4.5{\times}6mm$, $5{\times}6mm$, $6{\times}5.7mm$ implants (total 18 implants were placed in 14 patients, 8 on maxilla, 10 on mandible). The control group was composed of $4.5{\times}8mm$, $5{\times}8mm$, $4.5{\times}11mm$, $5{\times}11mm$. All implants were selected only by implants placed on molar area. We evaluated marginal bone loss in radiographic images at baseline (implant loading) and 3, 6, 12 months after loading. Additionally, crown-to-implant ratio was evaluated, and marginal bone loss according to crown-to-implant ratio after functional loading was analyzed. Results: The short implant group had a mean marginal bone level of $-0.52{\pm}0.69mm$; the 8mm group, $-0.22{\pm}0.82mm$; and the II mm group, $-0.10{\pm}1.09mm$ after I year of functional loading. But significant differences were not detected between three groups at every follow-up period. Crown-to-implant ratio in short implant group was $1.55{\pm}0.23$; 8mm group was $1.15{\pm}0.18$; and 11mm group was $0.92{\pm}0.15$. Additionally, significant differences between three groups were founded. (P<.0001) The greatest marginal bone loss after 1 year follow-up was founded at crown-to-implant ratio 1~1.49 range in short implant. Conclusion: The marginal bone loss of short implants was comparable to that of long implants. So, the short implants can be a clinically acceptable option.

Prognosis after treatment with multiple dental implants under general anesthesia and sedation in a cerebral palsy patient with mental retardation: A case report

  • Hong, Young-Joon;Dan, Jung-Bae;Kim, Myung-Jin;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제17권2호
    • /
    • pp.149-155
    • /
    • 2017
  • Cerebral palsy is a non-progressive disorder resulting from central nervous system damage caused by multiple factors. Almost all cerebral palsy patients have a movement disorder that makes dental treatment difficult. Oral hygiene management is difficult and the risks for periodontitis, dental caries and loss of multiple teeth are high. Placement of dental implants for multiple missing teeth in cerebral palsy patients needs multiple rounds of general anesthesia, and the prognosis is poor despite the expense. Therefore, making the decision to perform multiple dental implant treatments on cerebral palsy patients is difficult. A 33-year-old female patient with cerebral palsy and mental retardation was scheduled for multiple implant treatments. She underwent computed tomography (CT) under sedation and the operation of nine dental implants under general anesthesia. Implant-supported fixed prosthesis treatment was completed. During follow-up, she had the anterior incisors extracted and underwent the surgery of 3 additional dental implants, completing the prosthetic treatment. Although oral parafunctions existed due to cerebral palsy, no implant failure was observed 9 years after the first implant surgery.

인공치아 매식술 계획에 있어서 상이한 단층두께의 나선형 단층사진의 비교 (A Comparative Study of Spiral Tomograms with Different Slice Thicknesses in Dental Implant Planning)

  • 윤숙자
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.191-201
    • /
    • 1999
  • Purpose: To know whether there would be a difference among spiral tomograms of different slice thicknesses in the measurement of distances which are used for dental implant planning. Materials and Methods: 10 dry mandibules and 40 metal balls were used to take total 120 Scanorailll tomograms with the slice thickness of 2 mm, 4 mm and 8 mm. 3 oral radiologists interpreted each tomogram to measure the distances from the mandibular canal to the alveoalr crest and buccal. lingual and inferior borders of mandible. 3 observers recorded grades of 0, 1 or 2 to evaluate the perceptibility of alveolar crest and the superior border of mandibular canal. ANOVA with repeated measure. Chi-square tests and intrac!ass correlation coefficient(R₂, α) were used For statistical analysis. Results: There was not a statistically significant difference among spiral tomograms with different slice thicknesses in the measurement of the distances and in the perceptibility of alveolar crest and mandibular canal(p>0.05). All of them showed a good relationship in the reliability analysis. The perceptibility of alveolar crest and mandibular canal was almost similar and an excellent relationship was seen on all of them. Conclusions: There would be no significant difference. no matter which spiral tomogram of any slice thickness may be used in dental implant planning. considering the thickness of dental implant fixture.

  • PDF

Retrospective clinical study of an implant with a sandblasted, large-grit, acid-etched surface and internal connection: analysis of short-term success rate and marginal bone loss

  • Lee, Jae-Wang;An, Jun Hyeong;Park, Sang-Hoon;Chong, Jong-Hyon;Kim, Gwang-Seok;Han, JeongJoon;Jung, Seunggon;Kook, Min-suk;Oh, Hee-Kyun;Ryu, Sun-Youl;Park, Hong-Ju
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.42.1-42.7
    • /
    • 2016
  • Background: The purpose of this retrospective study was to evaluate the clinical utility of an implant with a sandblasted, large-grit, acid-etched (SLA) surface and internal connection. Methods: Six patients who received dental implants in the Department of Oral and Maxillofacial Surgery, Chonnam National University Dental Hospital, were analyzed by factors influencing the success rate and marginal bone loss. Factors included patient's age, sex, implant installation site, whether bone graft was done, type of bone graft materials, approaching method if sinus lift was done, and the size of the fixture. In addition, the marginal bone loss was analyzed by using a radiograph. Results: All implants were successful, and the cumulative survival rate was 100 %. Average marginal bone loss of 6 months after the installation was 0.52 mm and 20 months after the functional loading was 1.06 mm. Total marginal bone resorption was 1.58 mm on average. There was no statistically significant difference in mesial and distal marginal bone loss. Conclusions: The short-term clinical success rate of the implant with an SLA surface and internal connection was satisfactory. Moreover, the marginal bone loss was also consistent with the implant success criteria.

상악 전치부 잔존 유치와 매복 견치 발치 후 즉시 임플란트 식립: 증례 보고 (IMMEDIATE IMPLANT PLACEMENT AFTER EXTRACTION OF RETAINED DECIDUOUS TEETH AND IMPACTED CANINES: REPORT OF A CASE)

  • 유지연;김여갑;이백수;권용대;최병준;김영란;백진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권4호
    • /
    • pp.330-333
    • /
    • 2009
  • 저자들은 본 증례의 경우 치근이 흡수된 전치와 매복 견치의 발치 후 심한 치조골의 흡수와 연조직의 변화가 예상되는 것을 고려하여 발치 후 즉시 임플란트 수술을 결정하였다. 초기 안정성을 확보하기 위해 가능한 적은 골삭제, 보다 큰 직경과 치근형태의 임플란트를 선택하여 발치 후 즉시 임플란트를 식립하였고, 장골에서 채취한 망상골로 골결손부를 채우고 부가적으로 상순 지지를 위해 흡수성 차폐막과 순측 골면에 onlay형태의 골이식술을 시행하여 자연스럽고 심미적인 결과를 얻을 수 있었다.

골유도재생술 시 비탈회 동종골와 우심막유래 차단막의 임상적 활용 (Guided Bone Regeneration Using Mineralized Bone Allograft and Barrier Membrane Derived from Ox Pericardium)

  • 임형섭;김수관;문성용;오지수;정경인;박진주;정미애
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제33권4호
    • /
    • pp.359-362
    • /
    • 2011
  • Purpose: This study evaluated the clinical applications of implant placement and guided bone regeneration using a mineralized bone allograft and a barrier membrane derived from ox pericardium Methods: From January 2007 to June 2009, among the patients who received an implant at Chosun University Dental Hospital, patients were selected if they were treated with guided bone regeneration (GBR) with simultaneous implant placement or GBR prior to implant placement. The selected patients were sorted according to the materials and membranes used in GBR, and the implant survival rate was recorded by clinical examination and reviewing the medical records and the radiographs. Each study list was analyzed by SPSS (version 12.0, SPSS Inc., USA) software and the survival rate was verified by Chi-square tests. $P$ values less than 0.05% were deemed significant. Results: 278 implants were placed on a total of 101 patients and 8 implants resulted in failure. Three implants failed among 15 implants with only a mineralized bone allograft. No failure was shown among the 74 implants placed with mineralized bone allograft and a barrier membrane derived from ox pericardium. One group of 4 implant placements showed failure among the 102 implants placed with a mineralized bone allograft and another bone graft material. The group that had a barrier membrane derived from ox pericardium with a mineralized bone allograft or other bone materials showed no implant failure. Three failures were shown among the 21 implants placed with only bone graft and not using a membrane. The group with membranes other than a barrier membrane derived from ox pericardium showed 5 failures among 170 implants. Conclusion: The implant survival rate of the group with GBR using a mineralized bone allograft was 96.3%, which meant there was little difference compared to the groups of another bone graft materials (98.9%). The implant survival rate of the group without a membrane-was 85.7% and it showed a significant difference compared to the group using a barrier membrane derived from ox pericardium (100%) and the group using another membrane (97.1%).

상악 임플란트 피개의치에서 임플란트 보조 국소의치로의 전환: 증례보고 (Conversion of implant overdenture to an implant assisted removable partial denture in maxilla: case report)

  • 조성수;송민규;허윤혁;박찬진;조리라;고경호
    • 대한치과보철학회지
    • /
    • 제62권1호
    • /
    • pp.54-63
    • /
    • 2024
  • 장기간 사용된 임플란트 피개의치는 부착장치의 마모와 전치부 교합집중, 인공치 파절, 의치의 회전 등을 보일 수 있다. 이러한 문제점은 추가적인 임플란트 식립을 이용한 임플란트보조 국소의치(IARPD, implant assisted removable partial denture)로의 전환으로 개선할 수 있다. 본 증례는 임플란트 피개의치를 사용하는 3급 악간관계 환자에서 전치부에 집중된 교합을 분산하고 의치의 회전방지를 위해 서베이드 크라운을 이용한 IARPD으로 전환하였다. 여러 단계의 임시수복물을 통해 적절한 기능과 심미를 가진 최종보철물의 형태를 결정하였으며 최종 보철물의 적절한 구치부 교합과 임플란트 주위 변연골 유지를 보였기에 이를 보고하는 바이다.