• Title/Summary/Keyword: Oral implant

Search Result 1,697, Processing Time 0.025 seconds

The Healing of Exposed Implant Surfaces in A Maxillary Sinus Cavity (상악동 내 노출된 임플란트의 치유양상)

  • Lee, Seoung-Ho;Choi, Byung-Ho;Zhu, Shi-Jiang;Jung, Jae-Hyung;You, Tae-Min;Lee, Hyeon-Jung;Li, Jingxu;Huh, Jin-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.1073-1079
    • /
    • 2005
  • 1. Objective. The aim of this study was to investigate whether dental implant exposure to the maxillary sinus cavity increases the risk of maxillary sinus complications. 2. Study design. An implant was placed bilaterally in the maxillary sinus of eight adult female mongrel dogs in a way that it penetrated the bone and mucous membrane of the maxillary sinus floor to the extent of 2 mm, 4 mm, or 8 mm. The implants were left in place for six months. 3. Results. Radiographic and histologic examinations did not show any signs of pathologic findings in the maxillary sinus of the eight dogs. 4. Conclusion. This study indicates that implant protrusion into the maxillary sinus cavity is not related to the development of sinus complications.

Predictability of simultaneous implant placement with sinus floor elevation in the severely atrophic posterior maxillae ; Comparison of lateral and trans-crestal approaches (지상보수교육강좌 1 - 상악동저 거상술을 동반한 임프란트 동시 식립의 예지성 평가; 측방접근술과 치조정접근술의 비교)

  • Kim, Yeong-Wook;Keum, Yoon-Seon;Son, Hyo-Jeong;Lee, Jang-Yeol;Kim, Hyoun-Chull;Lee, Sang-Chull
    • The Journal of the Korean dental association
    • /
    • v.48 no.3
    • /
    • pp.205-217
    • /
    • 2010
  • Purpose The aim of this study is to evaluate the survival rates and analyze the stability of lateral approach and trans-crestal approach for maxillary sinus floor elevation of simultaneous implant placement. Materials and method 407 patients who have been treated in LivingWell dental hospital between 2003 to 2009 were selected. Lateral window technique, osteotome technique and sinus drill technique were used for sinus floor elevation procedure. A total of 714 implants-MP-1 HA coated implant(Tapered Screw $Vent^{TM}$, $Spline^{TM}$, Zimmer, USA), FBR surfaced implant(Pitt-$Easy^{TM}$, Oraltronics, Germany)-were placed in grafted maxillary sinus simultaneously. The autogenous bone or a combination with the allograft or alloplast was grafted into sinus. Sinus floor elevation was combined with vertical/horizontal onlay bone grafts to reconstruct the defect of alveolar ridge. Results The average preoperative height of the maxillary alveolar bone was 5.78mm(range: 0.4mm~12.5mm). 14 implants failed during the healing period(lateral approach: 4, trans-crestal approach: 10) and 3 implant failed after prosthetic loading(lateral approach: 2, trans-crestal approach: 1). The cumulative survival rate of implants after 6 years was 97.6%. Trans-crestal approach(97.4%) and lateral approach(97.9%) had similar survival rates. Conclusion The results indicate that the trans-crestal approach and lateral approach for maxillary sinus elevation is a acceptable method at atrophic maxillary posterior area.

Prognosis in case of nerve disturbance after mandibular implant surgery in relation to computed tomography findings and symptoms

  • Na, Ji Yeon;Han, Sang-Sun;Jeon, KugJin;Choi, Yoon Joo;Choi, Seong Ho;Lee, Chena
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.2
    • /
    • pp.127-135
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the computed tomography (CT) imaging findings and clinical symptoms of patients who complained of neurosensory disturbances after mandibular implant surgery, and to investigate the relationships of these parameters with the prognosis for recovery. Methods: CT scans were reviewed in 56 patients with nerve disturbance after mandibular implant surgery. Two oral radiologists classified the imaging findings into intrusion, contact, close, and separate groups according to the distance from the inferior border of the implant to the roof of the mandibular canal (MC). The symptoms of 56 patients were classified into 8 groups and the frequency of each group was investigated. Patients were categorized according to symptom improvement into no recovery and recovery groups, and the relationships of recovery with the CT classification and specific symptom groups were analyzed. Results: Thirty-eight of the 56 nerve disturbance cases showed improvement. The close and separate groups in the CT classification had a strong tendency for recovery (90.9% and 81.8%, respectively) (P<0.05). Although the lowest recovery rate was found in the intrusion group, it was non-negligible, at 50%. The 6 patients with a worm crawling feeling all improved, while the 8 cases with a tightening sensation showed the lowest recovery rate, at 12.5%, and the symptom of a tightening sensation occurred only in the intrusion and contact groups. Conclusions: The closer the implant fixture was to the MC on CT images, the less likely the patient was to recover. Regarding paresthesia symptoms, while a worm crawling feeling is thought to be a predictor of recovery, a tightening sensation appeared to be associated with a lower recovery rate.

CLINICAL EVALUATION OF DELAYED VERSUS SIMULTANEOUS IMPLANTATION WITH SINUS LIFTING (상악동거상술시 임프란트의 지연식립과 즉시식립에 대한 임상적 연구)

  • Suh, Dong-Won;Lee, Dong-Keun;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.6
    • /
    • pp.442-450
    • /
    • 2009
  • Purpose: Simultaneous implantation has been traditionally limited to patients with at least 5 mm of residual bone to ensure that the implant is completely stabilized. This is considered to be one of the most critical factors for primary implant stability and parallelism and, subsequently osseointegration. Recently, improved initial implant stability is provided by advancement of surgical techniques, implant designs and surface treatments. This has led surgeons to extending simultaneous treatment option to patients with below 4 mm of residual bone height, despite the lack of much data. The purpose of this study was to retrospectively evaluate and compare the status of implants which are installed by delayed and simultaneous methods. Material and methods: The subjects were patients(121 patients, 278 implants) who had been operated with sinus lifting from 2003 to 2007 in Sun Dental Hospital. Lateral window approach with autograft and xenograft(1:1 ratio) were carried out for all sinus lifting. 4 types of implant were used. The mean follow up period was 26.3 months(19 - 58 months) in delayed group, and 22.8 months(18 - 43 months) in simultaneous group. Results: The survival rate of implant restoration of this study was 98.2% in delayed group and 91.7% in simultaneous group. In simultaneous group, wide-platform type implants showed 100% survival rate. The total average of marginal bone loss in radiographs was $0.96\;{\pm}\;0.29\;mm$ in delayed group and $1.02\;{\pm}\;0.31\;mm$ in simultaneous group. Conclusion: Simultaneous implantation with sinus lifting(below 4mm of residual bone height) could be predictable treatment.

EFFECTS OF OSSEOINTEGRATION ACCORDING TO IMPLANT PLACEMENT TIMING IN THE DISTRACTED ALVEOLAR BONE OF DOGS (치조골 신연 후 임프란트 매식 시기에 따른 골유착 효과)

  • Jung, Hyun;Oh, Hee-Kyun;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.3
    • /
    • pp.238-244
    • /
    • 2000
  • The present study was aimed to investigate the effect of osseointegration according to implant placement timing in the distracted alveolar bone using intraoral distraction device. Six adult mongrel dogs of either sex, weighing about 15kg, were used. The animals were divided into 4-week and 8-week groups according to the timing of implant installation. The left upper and lower premolars and first molars were extracted and an alveoloplasty was performed to simulate an atrophic ridge. After 12 weeks of healing, a segmental osteotomy was made and an intraoral distraction device which was designed for augmentation of vertical height of the edentulous ridge was applied. Latency period was allowed for 5 days and then distraction was made at a rate of 1.2mm/day for 8 days. Four or eight weeks after distraction, implants were installed. Twelve weeks after implant installation, the animals were sacrificed. Macroscopic, radiographic, and histologic examinations of distracted alveolar ridge were performed. No significant abnormalities such as infection and dehiscence of overlying soft tissue were observed. Radiographically, there was slight bone resorption around the medial and distal edges of the alveolar bone segment, and a new bone deposition was observed in the neighboring alveolar crest area in the both groups. The satisfactory osseointegration was achieved in the distracted gap of the both groups, but fibrous tissue appeared on the buccal side of implant in the distracted gap in 4-week group. These results suggest that proper timing of implant installation is 8 weeks rather than 4 weeks after distraction when dental implant is to be placed onto the distracted bone.

  • PDF

THE HISTOLOGIC STUDY OF THE GRAFTED hBMP-I FOR IMMEDIATE IMPLANT FIXATION (발치 후 즉시 임플란트 식립시 이식된 hBMP-I의 조직학적 고찰)

  • Lee, Eun-Young;Kim, Kyoung-Won;Choi, Hee-Won;Um, In-Woong;Chung, Ho-Yong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.316-322
    • /
    • 2004
  • A low molecular weight component named bone morphogenetic protein(BMP) chemically isolated from the organic matrix of bone, induce postfetal connective tissue cells surrounding small blood vessels to differentiate into cartilage and bone. The end product of BMP is a spherical ossicle of lamella bone filled with red bone marrow for the functional loading. This is a important point that the graft material is embedded the defect site during the implant surgery. Because present knowledge of the relationship between BMP and bone regeneration arises mainly from studies of induced bone formation in heterotopic sites, it would be helpful to determine whether BMP plays any part in the process of bone healing. The BMPs have been shown to play crucial roles in normal skeletal development as well as bone healing and are able to activate transcription of genes involved in cellular migration, proliferation, and differentiation. The delivery of BMP on matrices has been efficacious in the treatment of defect bone in implant surgery. The purpose of the histologic study was to evaluate the effect of DLB(demineralized lyophilized bone) coated with purified human BMP(hBMP-I) in immediate implant surgery with bony defect to obtain the functional structure of implant asap. The ability of a graft of hBMP-I to accelerate bony defect repair provides a rationale for its use in immediate implant surgery that have large bone defect in edentulous area.

Five-year retrospective radiographic follow-up study of dental implants with sandblasting with large grit, and acid etching-treated surfaces

  • Kim, Hak-Kyun;Lee, Eun-Young;Kim, Jae-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.6
    • /
    • pp.317-321
    • /
    • 2015
  • Objectives: The purpose of this study is to evaluate five-year radiographic follow-up results of the Korean sandblasting with large grit, and acid etching (SLA)-treated implant system. Materials and Methods: The subjects of the study are 54 patients who have been followed-up to date, of the patients who underwent implant surgery from May 1, 2009 to April 30, 2011. In all, 176 implant placements were performed. Radiographs were taken before the first surgery, immediately after the first and second surgeries, immediately and six months after the final prosthesis installation, and every year after that. Bone loss was evaluated by the method suggested by Romanos and Nentwig. Results: A total of 176 implant placements were performed - 122 in men and 54 in women. These patients have been followed-up for an average of 4.9 years. In terms of prosthetic appliances, there were 156 bridges and 20 single prostheses. Nine implants installed in the maxillary molar area, three in the mandibular molar area and two in the maxillary premolar area were included in group M, with bone loss less than 2 mm at the crestal aspect of the implant. Of these, eight implants were single prostheses. In all, six implants failed - four in the mandible and two in the maxilla. All of these failures occurred in single-implant cases. The implant survival rate was 98.1% on the maxilla and 94.3% on the mandible, with an overall survival of 96.6%. Conclusion: Within the limitations of this study, implants with the SLA surface have a very superior survival rate in relatively poor bone environments such as the maxilla.

The effects of tetracycline-HCI on SLA implant surface structure (염산 테트라싸이클린이 SLA 임플란트의 표면 구조에 미치는 영향)

  • Sea, Mi-Ran;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.251-263
    • /
    • 2007
  • The present study was performed to evaluate the effects of Tetracycline-HCI on the microstructure change of SLA implant surface according to application time. In the Tetracycline-HCI group, 6 implants were rubbed with sponges soaked $50mg/m{\ell}$ Tetracycline-HCI solution for O.5min., lmin., 1. 5min., 2min., 2.5min. and 3min. In the saline group. another 6 implants conditioned with sponges soaked saline using same methods. One implant wasn't conditioned anything. Then, the changes of surface roughness values were evaluated by optical interferometer & specimens were processed for scanning electron microscopic observation. The results of this study were as follows: 1. In both Tetracycline-HCI group & saline group, there are no significant differences between surface roughness values before & after surface detoxification. And in scanning electron microscopic observation. there are slightly changes of implant surface structures but this changes were not significant by comparison with no treatment implant surface. 2. In the changes of surface roughness values & the scanning electron microscopic observation, there were no significant differences between saline & Tetracycline-HCI groups. In conclusion, the detoxification with $50mg/m{\ell}$ Tetracycline-HCI within 3 minutes can be applied for treatment of peri-implantitis in SLA surface implants. without surface microstructure changes.

Long-term effect of implant-abutment connection type on marginal bone loss and survival of dental implants

  • Young-Min Kim;Jong-Bin Lee;Heung-Sik Um;Beom-Seok Chang;Jae-Kwan Lee
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.496-508
    • /
    • 2022
  • Purpose: This study aimed to compare the long-term survival rate and peri-implant marginal bone loss between different types of dental implant-abutment connections. Methods: Implants with external or internal abutment connections, which were fitted at Gangneung-Wonju National University Dental Hospital from November 2011 to December 2015 and followed up for >5 years, were retrospectively investigated. Cumulative survival rates were evaluated for >5 years, and peri-implant marginal bone loss was evaluated at 1- and 5-year follow-up examinations after functional loading. Results: The 8-year cumulative survival rates were 93.3% and 90.7% in the external and internal connection types, respectively (P=0.353). The mean values of marginal bone loss were 1.23 mm (external) and 0.72 mm (internal) (P<0.001) after 1 year of loading, and 1.20 mm and 1.00 mm for external and internal abutment connections, respectively (P=0.137) after 5 years. Implant length (longer, P=0.018), smoking status (heavy, P=0.001), and prosthetic type (bridge, P=0.004) were associated with significantly greater marginal bone loss, and the use of screw-cement-retained prosthesis was significantly associated (P=0.027) with less marginal bone loss. Conclusions: There was no significant difference in the cumulative survival rate between implants with external and internal abutment connections. After 1 year of loading, marginal bone loss was greater around the implants with an external abutment connection. However, no significant difference between the external and internal connection groups was found after 5 years. Both types of abutment connections are viable treatment options for the reconstruction of partially edentulous ridges.

Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis

  • Magat, Guldane;Oncu, Elif;Ozcan, Sevgi;Orhan, Kaan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.1
    • /
    • pp.41-49
    • /
    • 2022
  • Objectives: We compared changes in fractal dimension (FD) and grayscale value (GSV) of peri-implant alveolar bone on digital panoramic radiography (DPR) and cone-beam computed tomography (CBCT) immediately after implant surgery and 12 months postoperative. Materials and Methods: In this retrospective study, 16 patients who received posterior mandibular area dental implants with CBCT scans taken about 2 weeks after implantation and one year after implantation were analyzed. A region of interest was selected for each patient. FDs and GSVs were evaluated immediately after implant surgery and at 12-month follow-up to examine the functional loading of the implants. Results: There were no significant differences between DPR and CBCT measurements of FD values (P>0.05). No significant differences were observed between FD values and GSVs calculated after implant surgery and at the 12-month follow-up (P>0.05). GSVs were not correlated with FD values (P>0.05). Conclusion: The DPR and reconstructed panoramic CBCT images exhibit similar image quality for the assessment of FD. There were no changes in FD values or GSVs of the peri-implant trabecular bone structure at the 12-month postoperative evaluation of the functional loading of the implant in comparison to values immediately after implantation. GSVs representing bone mass do not align with FD values that predict bone microstructural parameters. Therefore, GSVs and FDs should be considered different parameters for assessing bone quality.