• 제목/요약/키워드: Oral and maxillofacial reconstruction

Search Result 447, Processing Time 0.026 seconds

골유도 재생술과 임프란트 식립: 동시식립과 지연식립의 비교 (IMPLANT INSTALLATION AFTER GUIDED BONE REGENERATION: COMPARISON BETWEEN IMMEDIATE AND DELAYED GROUP)

  • 김영균;윤필영;임재형;황정원;이효정
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권4호
    • /
    • pp.333-339
    • /
    • 2007
  • Adequate bone quantity is one of the important factor to obtain osseointegration after implantation. Guided bone regeneration (GBR) has widely used in implantation for reconstruction of bony defects. Since introducing this procedure, there are many studies about survival rate of implants, changing in surrounding bone volume after function. The purpose of this study was to evaluate the amount of resorption according to placement timing and survival rate after function. The subjects were patients who had been operated with GBR from Jun 2003 to Jun 2004 in Seoul National University Bundang Hospital. They were divided into simultaneous and delayed placement group. The follow up had been performed at the time of just after GBR, 1, 3, 6, 12, 24-month later and standard periapical radiographs were taken to estimate the bone level at the time. The total average of bone level change in radiographs was 1.94mm(${\pm}0.25$), and 1.92mm(${\pm}0.72$) in simultaneous installation, 2.03mm(${\pm}0.25$) in delayed installation. In this report, the survival rates were 92.2% in simulataneous group and 92.3% in delayed group. Insufficient primary stability, early contamination of wound, overloading, poor oral hygiene, and infection were thought to be associated factors in the failed cases.

CT절편두께와 RP방식이 3차원 의학모델 정확도에 미치는 영향에 대한 연구 (Influence of slice thickness of computed tomography and type of rapid protyping on the accuracy of 3-dimensional medical model)

  • 엄기두;이병도
    • Imaging Science in Dentistry
    • /
    • 제34권1호
    • /
    • pp.13-18
    • /
    • 2004
  • Purpose : This study was to evaluate the influence of slice thickness of computed tomography (CT) and rapid protyping (RP) type on the accuracy of 3-dimensional medical model. Materials and Methods: Transaxial CT data of human dry skull were taken from multi-detector spiral CT. Slice thickness were 1, 2, 3 and 4 mm respectively. Three-dimensional image model reconstruction using 3-D visualization medical software (V-works /sup TM/ 3.0) and RP model fabrications were followed. 2-RP models were 3D printing (Z402, Z Corp., Burlington, USA) and Stereolithographic Apparatus model. Linear measurements of anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared according to slice thickness and RP model type. Results: There were relative error percentage in absolute value of 0.97, 1.98,3.83 between linear measurements of dry skull and image models of 1, 2, 3 mm slice thickness respectively. There was relative error percentage in absolute value of 0.79 between linear measurements of dry skull and SLA model. There was relative error difference in absolute value of 2.52 between linear measurements of dry skull and 3D printing model. Conclusion: These results indicated that 3-dimensional image model of thin slice thickness and stereolithographic RP model showed relative high accuracy.

  • PDF

Consequence of Synthetic Bone Substitute Used for Alveolar Cleft Graft Reconstruction (Preliminary Clinical Study)

  • Rawaa Y. Al-Rawee;Bashar Abdul-Ghani Tawfeeq;Ahmed Mothafar Hamodat;Zaid Salim Tawfek
    • Archives of Plastic Surgery
    • /
    • 제50권5호
    • /
    • pp.478-487
    • /
    • 2023
  • Background The outcome of alveolar grafting with synthetic bone substitute (Osteon III) in various bone defect volumes is highlighted. Methods A prospective study was accomplished on 55 patients (6-13 years of age) with unilateral alveolar bone cleft. Osteon III, consisting of hydroxyapatite and tricalcium phosphate, is used to reconstruct the defect. Alveolus defect diameter was calculated before surgery (V1), after 3 months (V2), and finally after 6 months (V3) postsurgery. In the t-test, a significant difference and correlation between V1, V2, and V3 are stated. A p-value of 0.01 is considered a significant difference between parameters. Results The degree of cleft is divided into three categories: small (9 cases), medium (20 patients), and large (26 cases).The bone volume of the clefted site is divided into three steps: volume 1: (mean 18.1091 mm3); step 2: after 3 months, volume 2 resembles the amount of unhealed defect (mean 0.5109 mm3); and the final bone volume assessment is made after 6 months (22.5455 mm3). Both show statistically significant differences in bone volume formation. Conclusion An alloplastic bone substitute can also be used as a graft material because of its unlimited bone retrieval. Osteon III can be used to reconstruct the alveolar cleft smoothly and effectively.

치과에서 디지털 x-선 영상의 이용 (Digital X-ray Imaging in Dentistry)

  • 김은경
    • 치과방사선
    • /
    • 제29권2호
    • /
    • pp.387-396
    • /
    • 1999
  • In dentistry. RadioVisioGraphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter. many types of direct digital radiographic system have been produced in the last decade. They are based either on charge-coupled device(CCD) or on storage phosphor technology. In addition. new types of digital radiographic system using amorphous selenium. image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose. image processing, computer storage. electronic transfer of images and so on. Image processing includes image enhancement. image reconstruction. digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system(IMACS) for dentomaxillofacial radiology was reported in 1992. IMACS in dental hospital has been increasing. Meanwhile. researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible. feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis. have been performed actively in the last decade. Further developments in digital radiographic imaging modalities. image transmission system. imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  • PDF

다양한 골증대술을 동반한 상악전치부 임플란트 식립 증례 (Maxillary Anterior Implant Placement with Various Bone Agumentation on Atrophic Thin Ridge : Case Reports)

  • 지영덕;조이수
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.145-155
    • /
    • 2007
  • The advent of osseointegration and advances in biomaterials and techniques have contributed to increased application of dental implants in the restoration of maxillary partial edentulous patients. Often, in these patients, soft and hard tissue defects result from a variety of causes, such as infection, trauma, and tooth loss. These create an anatomically less favorable foundation for ideal implant placement. Reconstruction of the atrophic maxillary alveolar bone through a variety of regenerative surgical procedures has become predictable; it may be necessary prior to implant placement or simultaneously at the time of implant surgery to provide a restoration with a good long-term prognosis. Regenerative procedures are used for horizontal and vertical ridge augmentation. Many different techniques exist for effective bone augmentation. The approach is largely dependent on the extent of the defect and specific procedures to be performed for the implant reconstruction. It is most appropriate to use an evidenced-based approach when a treatment plan is being developed for bone augmentation cases. The cases presented in this article clinically demonstrate the efficacy of using a autogenous block graft, guided bone regeneration, ridge split, immediated implant placement technique on the atrophic maxillary area.

전산화단층 촬영상의 임계치가 3차원 의학모델 정확도에 미치는 영향에 대한 연구 (Influence of threshold value of computed tomography on the accuracy of 3-dimensional medical model)

  • 이병도;이완
    • Imaging Science in Dentistry
    • /
    • 제32권1호
    • /
    • pp.27-33
    • /
    • 2002
  • Purpose: To evaluate the influence of threshold value of computed tomography on the accuracy of rapid prototyping (RP) medical model Material and Methods : CT datas of a human dry skull were transferred from CT scanner via compact disk to a personal computer (PC). 3-dimensional image reconstruction on PC by V-works/sup TM/ 3.0 (CyberMed. Inc.) software and RP models fabrication were followed. 2-RP models were produced by threshold value of 500 and 800 selected in surface rendering process. Linear measurements between arbitrary 12 anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared. Thus, the accuracy of 500 RP and 800RP models was respectively evaluated. Results: There was mean difference (% difference) in absolute value of 2.27 mm (2.73%) between linear measurements of dry skull and 500 RP model. There was mean difference (% difference) in absolute value of 1.94 mm (2.52%) between linear measurements of dry skull and 800 RP model. Conclusion: Slight difference of threshold value in rendering process of 3-D modelling made a influence on the accuracy of RP medical model.

  • PDF

구강악안면 영역에서 다양한 안면골 이식의 이용 (Use of a Variety of Facial Bone Grafts in Oral and Maxillofacial Surgery)

  • 김영균;김현태;여환호
    • 대한치과의사협회지
    • /
    • 제37권3호통권358호
    • /
    • pp.221-227
    • /
    • 1999
  • The aim of this study was to describe the clinical availability of a variety of facial bone grafts in oral and maxillofacial surgery. Thirty patients with oral and maxillofacial bone defects were treated with mandible, maxilla, and zygoma bone grafts. The ages of the patients ranged from 8 to 64 years, with a mean age of 28.6 years. The follow-up period ranged from 2 to 30 months, with a mean follow-up of 11.7 months. Although postoperative follow-up was of short duration, the recilient sites were favorable to healing and bone consolidation. Healing progressed normally without severe morbidity. The donor site did not present a management problem in any of the patients.Some minor complications developed in 8 patients, of which three were infections and another three were wound dehiscence. There complications were easily managed with incision and drainage, antibiotics and local wound care. We consider that a variety of facial bone grafts can be used for reconsider that a variety of facial bone grafts can be used for reconstruction of small or moderate large bony defects.

  • PDF

치과용 임프란트 매식을 위한 견갑골외연의 형태학적 연구 (MORPHOMETRIC STUDY OF SCAPULAR LATERAL BORDER FOR INSTALLATION OF DENTAL IMPLANT.)

  • 이종호;정숭룡
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제17권3호
    • /
    • pp.231-238
    • /
    • 1995
  • The scapular flap, described by dos Santos in 1986, has been used successfully for the reconstruction of a variety of defects of oro-mandible. Some have defined the gross and vascular anatomy of the lateral border of the scapula, yet useful anatomical information and a complete description of area and contour of each cut surface of lateral border of scapula, which is very important for esthetic and functional reconstruction using dental implants, are missing. These prompted us to clarify the cross-sectional area of lateral border of scapula. Twenty three scapulas of 15 fixed adult Caucasian cadavers were sectioned in every 1cm interval along the lateral border of scapular, and the metric relations and the shape of cut surface were assessed. The lateral border of the scapula, consisting of cortico-cancellous bone measuring $7.86{\pm}0.97mm$ in width, $19.6{\pm}2.86mm$ in height and $12{\pm}1.78cm$ in length, could be harvested as an osteocutaneous scapular flap or as a single vascularized bone flap. The mean thickness of cortical bone of lateral, medial, dorsal and costal surface was $0.46{\pm}1.48mm$, $1.78{\pm}1.34mm$, $1.54{\pm}1.11mm\;and\;1.35{\pm}0.87mm$, respectively. So we have thought that all scapular transplants could be supported osseointegrated implants for fixation of dental prosthesis.

  • PDF

하악골 신장술 후 하치조신경의 조직학적 변화와 신경성장인자의 발현에 대한 연구 (HISTOLOGICAL CHANGES AND EXPRESSION OF NERVE GROWTH FACTOR IN THE INFERIOR ALVEOLAR NERVE AFTER DISTRACTION OSTEOGENESIS)

  • 박봉욱;김종렬;변준호
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권5호
    • /
    • pp.415-423
    • /
    • 2005
  • Distraction osteogenesis (DO) is frequently used technique in reconstruction of bony defects resulted from tumor resection, congenital deformity, and trauma in the maxillofacial region. Although the histologic and ultrastructural changes associated with distraction osteogenesis have been extensively described, the exact changing of the surrounding tissues, such as nerve tissues, were still unclear. This study observed the histological changes and the expression of nerve growth factor (NGF) in the inferior alveolar nerve (IAN) after distraction osteogenesis. Unilateral mandibular distraction (0.5 mm twice per day for 10 days) was performed in eight mongrel dogs. Two animals were sacrificed at 7, 14, 28 and 56 days after completion of distraction, respectively. The distracted IAN and contralateral control nerve were harvested and processed for histological and innunohistochemical examinations. The signs of acute nerve injuries, such as demyelination and partial discontinuation of nerver fiber, were observed in the distracted IAN on 7 and 14 days after distraction. The initial remyelination and regeneration of distracted IAN were showed at 14 days after completion of distraction. At 56 days later, the histologic features of distracted IAN was similar to those of the normal control IAN. The expression of NGF was significantly increased in most distracted nerve tissues on 7, 14 and 28 days after distraction. On 56 days after distraction, the expression of NGF returned to the normal level. This study suggested that the acute IAN injury caused by mandibular distraction were mostly recovered during consolidation period. The NGF was seemed to be induced from Schwann cell and damaged nerve tissues, and it may have important roles in the initial healing of damaged nerves.

Accuracy of maxillofacial prototypes fabricated by different 3-dimensional printing technologies using multi-slice and cone-beam computed tomography

  • Yousefi, Faezeh;Shokri, Abbas;Farhadian, Maryam;Vafaei, Fariborz;Forutan, Fereshte
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.41-47
    • /
    • 2021
  • Purpose: This study aimed to compare the accuracy of 3-dimensional(3D) printed models derived from multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) systems with different fields of view (FOVs). Materials and Methods: Five human dry mandibles were used to assess the accuracy of reconstructions of anatomical landmarks, bone defects, and intra-socket dimensions by 3D printers. The measurements were made on dry mandibles using a digital caliper (gold standard). The mandibles then underwent MDCT imaging. In addition, CBCT images were obtained using Cranex 3D and NewTom 3G scanners with 2 different FOVs. The images were transferred to two 3D printers, and the digital light processing (DLP) and fused deposition modeling (FDM) techniques were used to fabricate the 3D models, respectively. The same measurements were also made on the fabricated prototypes. The values measured on the 3D models were compared with the actual values, and the differences were analyzed using the paired t-test. Results: The landmarks measured on prototypes fabricated using the FDM and DLP techniques based on all 4 imaging systems showed differences from the gold standard. No significant differences were noted between the FDM and DLP techniques. Conclusion: The 3D printers were reliable systems for maxillofacial reconstruction. In this study, scanners with smaller voxels had the highest precision, and the DLP printer showed higher accuracy in reconstructing the maxillofacial landmarks. It seemed that 3D reconstructions of the anterior region were overestimated, while the reconstructions of intra-socket dimensions and implant holes were slightly underestimated.