• Title/Summary/Keyword: Optometry

Search Result 579, Processing Time 0.028 seconds

Comparison between division of health science and dental hygiene in Korea (국내 의료보건계열 신설동향과 치위생(학)과 추이에 관한 연구)

  • Yang, Song-Yi;Kim, Sook-Hyang;Oh, Sang-Hwan
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.419-430
    • /
    • 2012
  • Objectives : This review suggests prospect of educational institutions through research on the establishment trend of Korean dental hygiene programs by comparison with health science programs, analysis based on location and year. Methods : For the research, 78 dental hygiene programs, 11 dental colleges, 144 nursing programs, 41 medicine programs, 38 radiology programs, 49 optometry programs, 39 biomedical laboratory science programs, 65 physical therapy programs, 48 occupational therapy programs were analyzed using SPSS 12.0v. The result is as follows. Results : Establishment trend of dentistry-related programs and dental hygiene programs is twice as high as nursing programs and medicine-related programs. Number of 3-years dental hygiene programs is twice as high as 4-years dental hygiene programs. Entrance quota of 3-years dental hygiene programs is four time higher than 4-years programs. On regional basis, number of dental hygiene programs is the highest in Gyeonggi-do by 9 while it is the lowest in Incheon-si and Jeju-do by 1. Number of students in dental hygiene programs is the highest in Gyeonggi-do by 2,514. Establishment of dental hygiene programs showed the biggest increasing trend in Gyeonggi-do and Jeju-do from 1995 to 1999; and in Gangwon-do, Chungcheongbuk-do, Chungcheongnam-do, Gyeongsangbuk-do, Gyeongsangnam-do, Jeollabuk-do, Jeollanam-do from 2005 to 2010. Conclusions : Assurance of legal rights in the workplace and improvement of educational environment should take prudence over establishment of dental hygiene programs in order to develop professionalism among students in dental hygiene.

Change of Contrast Sensitivity Induced by Tinted Spectacle Lens (칼라필터 렌즈에 따른 대비감도의 변화)

  • Seo, Jae-Myoung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.47-51
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the change of contrast sensitivity by prescribing tinted lenses and to provide the clinical manual. Methods: Contrast sensitivity was measured for twenty adults with normal vision while they wore yellow, orange and green tinted lenses. To measure contrast sensitivity, the 5 spatial frequencies (2, 4, 6, 8 and 10 cpd) were used for 33 ms and 233 ms, respectively. Results: The contrast sensitivity was overall higher with 233 ms than 33 ms (p<0.05). The peaks of contrast sensitivity with 33 ms and 233 ms were 1.75 log unit with the yellow lens and 1. 85 log unit without the color respectively. However, there was no significance between the yellow and orange tinted lens (p>0.64) Conclusions: Yellowish tinted lens that reduces chromatic aberration and the scattering is prescribed for the various purposes to improve visual functions. Before prescribing tinted lens, identifying characteristic of user and tinted lens for cut off wavelengths is recommended.

Development of a Calculating Program for the Prism Power Influencing to Binocular Vision according to Shift of Binocular Visual Points in the Distance Vision Spectacles (원용안경의 양안 주시점 이동에 따른 양안시에 미치는 프리즘 굴절력 산출 프로그램 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.257-262
    • /
    • 2010
  • Purpose: Developing a calculating program for the prism power which influenced the binocular vision according to shifts of binocular visual points in the distance vision spectacles. Methods: By using the Delphi 6.0 programming language, we developed a calculating program of the relative binocular prism power according to the movements of binocular visual points in the distance vision spectacles, which was calculated by dragging the mouse along the traces of binocular visual points on the computer window. Results: We developed a calculating program for the relative binocular prism power according to the movements of binocular visual points in the distance vision spectacles. The user of the program could confirm the trace of visual points by allowing them to display the trace of binocular visual points on the computer screen with a mouse button. An application on confirming the variation of prism power by graphs in the program also allowed the user to use the program more conveniently. Conclusions: By using the developed program, the user could easily calculate the relative binocular prism power according to shifts of binocular visual points in the distance vision spectacles. We also found that the developed program helped the user to receive a lot of assistance in analyzing the asthenopia.

Design of an Optical System for Iris Photographing (홍채 촬영용 광학계 설계)

  • Park, Seung-Hwan;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.39-44
    • /
    • 2009
  • Purpose: To design a mini optical system photographing the iris, which is used in the iridology. Methods: We designed a mini optical system photographing the iris by using the Sigma 2000 design program. Results: We designed a mini optical system photographing the iris, which is suitable in the CCD using a micro actuator for auto-focusing, of which characteristics have the TCL of 30 mm, a magnification of -0.65, about 8.0 mm distance from the 1st lens to the last lens, the max barrel diameter of 11 mm, and about 1 mm of the effective stop diameter. Also the resolution line width of this system is characterised by 92 lps/mm at the 30% MTF value criterion. Conclusions: By designing an optical system of which characteristics have the TCL of 30 mm, about 8.0 mm distance from the 1st lens to the last lens, the max barrel diameter of 11 mm, and the resolution line width of $5.4{\mu}m$ at the 30% MTF value criterion, we could miniaturize the iris photographing optical system.

  • PDF

A Study on Plasma Electrolytic Oxidation Surface Treatments for Magnesium Alloy Eyeglass Frames (마그네슘 합금 안경테의 Plasma Electrolytic Oxidation 표면처리 효과 연구)

  • Kim, Ki-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.313-317
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the surface characteristics of plasma electrolytic oxidation (PEO) surface treatment on AZ31 magnesium alloy eyeglass frames. Methods: The plasma electrolytic oxidation (PEO) surface was created by varying the DC voltage. The oxidation layer of coating was measured using phase analysis by X-ray diffraction. The microstructural morphology was observed using a scanning electron microscopy. Coating layer and the concentration of elements were investigated using the energy dispersive X-ray spectra. Results: The MgO XRD peak was increased as the voltage increased, and the density of the surface oxide film was also increased. The changes in the composition of the EDS also showed a good agreement. Conclusions: The compound oxide crystallization of PEO oxide film layer was done by increasing formation of MgO as the voltage increased. The treatment at 65V and 60 sec showed the best results at surface state, contact angles and salt spray test.

Distribution of Glutamate Receptors in the Retina of the Greater Horseshoe Bat (Rhinolophus ferrumequinum) (한국관박쥐 망막에서 글루타메이트 수용체의 분포 양상)

  • Kwon, Oh-Ju;Jeon, Chang-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.413-418
    • /
    • 2014
  • Purpose: The objective of this study was analyzing the distribution of the excitatory neurotransmitter glutamate receptor to investigate the function in the retina of the greater horseshoe bat. Methods: After retinal tissues of adult greater horseshoe bat were cut into $40{\mu}m$ vertical sections, standard immuno-cytochemical techniques was applied for analysis. Immunofluorescence images were obtained using the Bio-Rad MRC 1024 laser scanning confocal microscope. Results: AMPA (GluR1-4), Kainate (GluR5-7, KA1-2) and NMDA (1, 2A, 2B) mainly distributed in the inner plexiform layer and outer plexiform layer. KA1 receptors have existed not only plexiform layer but also ganglion cell layer. Conclusions: The greater horseshoe bat has same neuron and neurotransmitter to mammalian retina. These findings suggest that bat has a functional retina for visual analysis.

A Study of Correlation Among Binocular Dysfunctions and Academic Achievement (초등학생들의 양안시이상과 학업성취도와의 상관성 연구)

  • Lee, Sun Haeng;Cho, Hyun Gug;Park, Chun Man
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.481-487
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the correlation between non-strabismic binocular dysfunctions and academic achievement for primary school children. Methods: A total of 1,123 parents and their children aged 8-13 years responded to the College of Optometrists in Vision Development Quality of Life (COVD-QOL) questionnaire. Among the all participants, 123 children who have ${\geq}20$ of visual symptom scores, no amblyopia, no strabismus, no any ocular and systemic pathology, and no contact lenses wearing were chosen for this study finally. Binocular functions were evaluated for final subjects. Results: Of 123 primary school children who have criteria-eligible symptoms 93 had non-strabismic binocular dysfunctions. Accommodative dysfunction was significantly correlated to subjects of science and English, and vergence dysfunction was also significantly correlated to Korean, mathematics, social science, science and English in the final subjects. Conclusions: Correlations between academic achievement and accommodative/vergence dysfunctions were statistically significant. Therefore, accommodative/vergence dysfunctions may be factors to affect academic achievement.

Development of the Dot Sight Device by Using the Doublet Reflector (Doublet 반사경을 이용한 도트 사이트 장치의 개발)

  • Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.65-69
    • /
    • 2008
  • Purpose: To develop a dot sight device for a sighting shot using the doublet reflector. Methods: We designed the singlet reflector and the doublet reflector by Sigma 2000 program and compared the one to the other. Results: In analysis of finite ray aberration, we could confirm that it has the effective field of view with the free-parallax which is 3.3 times wider than the existing dot sight device using the singlet reflector. If you use the doublet reflector, the central thickness of optical system become more than two times bigger than the existing one. As a result, when the image of a target object is made on the observer's retina, if you make the first side's radius of curvature equal with the second one as the case of the singlet reflector, changes in magnification are appeared. To conquer this problem, we had to make be satisfied with the afocal condition in the case of doublet reflector. Conclusions: we could develop the dot sight device for a sighting shot using the doublet reflector which has the effective field of view with the free-parallax which is 3.3 times wider than the existing dot sight device using the singlet reflector.

  • PDF

Effect of Distance Phoria on Stereoacuity (원거리 사위도가 입체시에 미치는 영향)

  • Chun, Young-Yun;Joo, Seok-Hee;Park, Seong-Jong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.101-105
    • /
    • 2008
  • Purpose: In this study we measured the mean value of the distance stereoacutiy for adult subjects and evaluated the variation of the distance stereoacuity according to correction of phoria using the Pola Test E-II of Carl Zeiss. Methods: We investigated the distance stereoacuity for 50 adults (male: 29, female: 21) ranging in age from 19 to 46 years using D6 Circle chart and D8 Line chart in the Pola Test E-II. Results: The mean values of the distance stereoacuity measured on the D6 Circle test and D8 Line test were 159.6 and 149.4 seconds of arc respectively. The mean variations of the distance stereoacuity according to correction of phoria in D6 Circle test were increased 43.2 seconds of arc in exophoria and 51 seconds of arc in esophoria, and those in D8 Line test were increased 42 seconds of arc in exophoria and 70.2 seconds of arc in esophoria. Conclusions: We knew from these results that the distance stereoacuity after prescription of phoria improved more esophoria than exophoria.

  • PDF

Reconstruction Method of Spatially Filtered 3D images in Integral Imaging based on Parallel Lens Array (병렬렌즈배열 기반의 집적영상에서 공간필터링된 3차원 영상 복원)

  • Jang, Jae-Young;Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.3
    • /
    • pp.659-666
    • /
    • 2015
  • In this paper, we propose a novel reconstruction method of spatially filtered 3D images in integral imaging based on parallel lens array. The parallel lens array is composed of two lens arrays, which are positioned side by side through longitudinal direction. Conventional spatial filtering method by using convolution property between periodic functions has drawback that is the limitation of the position of target object. this caused the result that the target object should be located on the low depth resolution region. The available spatial filtering region of the spatial filtering method is depending on the focal length and the number of elemental lens in the integral imaging pickup system. In this regard, we propose the parallel lens array system to enhance the available spatial filtering region and depth resolution. The experiment result indicate that the proposed method outperforms the conventional method.